Friedrich PROH50 T2 FD310BM Water Heater Specifications (3.5 UEF)
The Friedrich PROH50 T2 FD310BM (Hybrid/Electric Heat Pump, Electric) achieves a certified 3.5 UEF rating across its 45-gallon nominal tank, 67 gal First Hour Rating, ranking #481 of 706 among 706 ENERGY STAR Hybrid/Electric Heat Pump models (PD 3845920). Under the May 6, 2029 DOE 10 CFR 430.32(d)(2) standard, compliance status is Pass: +1.20 / +52.2%. Rated annual electricity draw of 915 kWh/yr equates to roughly $166/yr ($1,662 over 10 years) at 18.16 cents/kWh. Closest certified alternative is Rheem CPROPH50 T2 RH350BM (3.5 UEF).
- Uniform Energy Factor
- 3.5 UEF
- Cohort UEF Rank
- #481 of 706
- First Hour Rating
- 67 gal
- Storage Volume
- 45 gal
- Fuel / Type
- Electric / Hybrid/Electric Heat Pump
- DOE 2029 Rule Status
- Pass: +1.20 / +52.2%

Friedrich PROH50 T2 FD310BM (3.5 UEF) ranks #481 of 706 Hybrid/Electric Heat Pump models — 64-way tie; more efficient than 22.9% of Hybrid/Electric Heat Pump models, -0.20 UEF below the 3.70 UEF median.
Federal 2029 margin for Friedrich PROH50 T2 FD310BM: +1.20 UEF (+52.2%) vs. 10 CFR 430.32(d)(2) Electric >35 to <=55 gal (2.30 UEF). At EIA August 2026 national rates (18.16 cents/kWh), 915 kWh/yr for Friedrich PROH50 T2 FD310BM runs ~$166/yr vs. ~$632/yr for a 0.92 UEF electric tank.
State electric sensitivity for Friedrich PROH50 T2 FD310BM: 10-year operating spend spans $1,339 in Washington (Lowest Hydro Tier) (14.63 cents/kWh) to $4,317 in Hawaii (Highest EIA State) (47.18 cents/kWh).
Peer comparison: Friedrich PROH50 T2 FD310BM (3.5 UEF) compares closely with Rheem CPROPH50 T2 RH350BM (3.5 UEF, at parity) and Ruud PRO H50 T2 RU310BM (3.5 UEF, at parity).
How Do Friedrich PROH50 T2 FD310BM Specs Compare to Hybrid/Electric Heat Pump Medians?
Friedrich PROH50 T2 FD310BM places #481 of 706 across 706 certified Hybrid/Electric Heat Pump configurations, with physical dimensions, draw profile, and thermal metrics benchmarked below.
| Specification Attribute | Certified Value | Cohort Benchmark / Delta | Provenance |
|---|---|---|---|
| Manufacturer / Brand | Friedrich | 61 certified listings | ENERGY STAR PD 3845920 |
| Model Number | PROH50 T2 FD310BM | Draw pattern: Medium-Usage | PROH50 T2 FD310BM |
| Uniform Energy Factor (UEF) | 3.5 | -0.20 UEF vs. 3.70 UEF median | 10 CFR 430 Test Method |
| First Hour Rating (FHR) | 67 gal | -5 gal vs. 72 gal median | 10 CFR 430 Recovery Test |
| Rated Annual Electricity Use | 915 kWh/yr | -157 kWh/yr vs. 1,072 kWh/yr median | Est. $166/yr @ $0.1816/kWh (EIA US Avg) |
| Thermal Recovery Efficiency | 400% | -29.0 pts vs. 429.0% median | ENERGY STAR Dataset |
| Physical Envelope (H x Dia) | 61.8" H x 22.3" D | Fits standard 72 in. basement/garage clearance; clears 28 in. utility doorway (22.3" D) | Doorway & ceiling check |
| Electrical Circuit Requirements | 240 V / 21 A max | Requires 240V dedicated branch circuit; check panel capacity | NEC / Branch circuit check |
| Heat Pump Refrigerant & GWP | R-134a (GWP:1430) | Check regional AIM Act phase-down transition | EPA AIM Act Compliance |
| Certification Date | 2026-10-15 | Certified 2026-10-15 | Markets: United States |
What Does PROH50 T2 FD310BM Cost to Operate Across State Electricity Rates?
At 915 kWh/yr, Friedrich PROH50 T2 FD310BM runs roughly $166/yr on the EIA national average tier under August 2026 Table 5.6.A rates.
| Jurisdiction (EIA Aug 2026) | Residential Rate | Annual Cost | 10-Yr Operating Spend | 10-Yr Savings vs. 0.92 UEF |
|---|---|---|---|---|
| United States Average | 18.16 ¢/kWh ($0.1816) | $166/yr | $1,662 | $4,660 |
| Hawaii (Highest EIA State) | 47.18 ¢/kWh ($0.4718) | $432/yr | $4,317 | $12,106 |
| California | 29.75 ¢/kWh ($0.2975) | $272/yr | $2,722 | $7,634 |
| Texas | 15.91 ¢/kWh ($0.1591) | $146/yr | $1,456 | $4,083 |
| Washington (Lowest Hydro Tier) | 14.63 ¢/kWh ($0.1463) | $134/yr | $1,339 | $3,754 |
Are There Active CPSC Safety Recalls for Friedrich Water Heaters?
Zero active CPSC recalls matched Friedrich in our 2026-11-23 SaferProducts sweep; verify your individual tank date code via our lookup tool. See Serial Number Lookup.
Which Certified Water Heaters Match PROH50 T2 FD310BM Most Closely?
These 5 competing Hybrid/Electric Heat Pump units sit nearest to Friedrich PROH50 T2 FD310BM by storage capacity and 3.5 UEF rating.
| Brand & Model | Type | Vol | FHR | UEF (Δ) | kWh/yr |
|---|---|---|---|---|---|
| Rheem CPROPH50 T2 RH350BM | Hybrid/Electric Heat Pump | 45 gal | 67 gal | 3.5 (at parity) | 915 |
| Ruud PRO H50 T2 RU310BM | Hybrid/Electric Heat Pump | 45 gal | 67 gal | 3.5 (at parity) | 915 |
| A. O. Smith HPACO-45 1**+AXST-50T 1** | Hybrid/Electric Heat Pump | 45 gal | 67 gal | 3.52 (+0.02) | 923 |
| American MHPCO-45 1**+MXST-50T 1** | Hybrid/Electric Heat Pump | 45 gal | 67 gal | 3.52 (+0.02) | 923 |
| Rheem ECE H50 T2 RH310BM | Hybrid/Electric Heat Pump | 45 gal | 67 gal | 3.5 (at parity) | 915 |
When Should Homeowners Skip Friedrich PROH50 T2 FD310BM (Hybrid/Electric Heat Pump)?
Check Friedrich PROH50 T2 FD310BM's mechanical constraints—including utility space, Electric capacity, and Pass: +1.20 / +52.2% status—against typical residential installations.
Key Limitations & Exclusions
- Friedrich PROH50 T2 FD310BM needs >=450 cu ft room air volume or ducting so compressor cooling does not stall recovery.
- Compressor runs near 49 dBA; avoid mounting Friedrich PROH50 T2 FD310BM directly beside quiet bedrooms.
- Requires condensate drain routing and 240V electrical capacity; verify state DOE HEAR status.
Which Option Fits Your Situation?
What Are the Key Questions About Friedrich PROH50 T2 FD310BM?
Direct answers to common technical, regulatory, and sizing questions sourced from primary U.S. government and OEM documentation.
Will Friedrich PROH50 T2 FD310BM stay compliant after the May 6, 2029 DOE standard takes effect?
Tested at 3.5 UEF, Friedrich PROH50 T2 FD310BM shows Pass: +1.20 / +52.2% relative to May 6, 2029 federal DOE limits while placing #481 of 706 among 706 Hybrid/Electric Heat Pump peers like Rheem CPROPH50 T2 RH350BM.
Will Friedrich PROH50 T2 FD310BM fit through a standard utility door and 72-inch basement ceiling?
Measuring 61.8 in. tall by 22.3 in. diameter, Friedrich PROH50 T2 FD310BM notes: fits standard 72 in. basement/garage clearance; clears 28 in. utility doorway (22.3" d). Reserve space above the jacket for T&P piping and anode removal.
Do existing utility hookups support Friedrich PROH50 T2 FD310BM during replacement?
Electrical specs for Friedrich PROH50 T2 FD310BM call for 240V at 21A max (Requires 240V dedicated branch circuit; check panel capacity). Have a licensed electrician inspect panel load and wire gauge.
What is the estimated 10-year operating spend for Friedrich PROH50 T2 FD310BM?
At 18.16 cents/kWh national residential pricing, Friedrich PROH50 T2 FD310BM's 915 kWh/yr draw equals roughly $166 annually or $1,660 across a 10-year horizon (ranging from $134/yr in Washington hydro tiers up to $432/yr in Hawaii).
When is Friedrich PROH50 T2 FD310BM a poor fit for a residential replacement?
Avoid placing Friedrich PROH50 T2 FD310BM directly next to bedrooms or inside tight <300 cu ft closets without ducting, due to 49 dBA sound and cool exhaust airflow.
What First Hour Rating or flow capacity does Friedrich PROH50 T2 FD310BM deliver?
With 67 gal FHR (-5 gal vs. 72 gal median), Friedrich PROH50 T2 FD310BM fits larger 3–5 person homes cleanly.
How do you verify manufacturing age and recall status on Friedrich PROH50 T2 FD310BM?
Our 2026-11-23 CPSC SaferProducts feed lists zero recalls for Friedrich; verify exact manufacturing week for Friedrich PROH50 T2 FD310BM using the Serial Number Lookup tool.
Does Friedrich PROH50 T2 FD310BM qualify for DOE HEAR incentives after 25C expired?
After 25C sunset on Dec 31, 2025 under OBBBA, check state DOE HEAR (up to $1,750 income-qualified) and utility rebates for Friedrich PROH50 T2 FD310BM. Closest peer in Hybrid/Electric Heat Pump is Rheem CPROPH50 T2 RH350BM (3.5 UEF).
Sources
- ENERGY STAR Certified Water Heaters Dataset (Socrata pbpq-swnu) — U.S. EPA & DOE ENERGY STAR, 2026 Live Certified Registry (retrieved 2026-11-23)
- 10 CFR 430.32 — Energy and Water Conservation Standards (Water Heaters & Plumbing Fixtures) — U.S. Department of Energy / eCFR, 2026 eCFR (incl. May 6, 2029 Rule) (retrieved 2026-11-23)
- CPSC SaferProducts.gov Product Recalls REST API — U.S. Consumer Product Safety Commission, 2026 Live Recalls Feed (retrieved 2026-11-23)
- EIA Electric Power Monthly Table 5.6.A — Average Residential Electricity Price by State — U.S. Energy Information Administration (EIA), August 2026 Monthly Release (retrieved 2026-11-23)