JETGLAS RE2H50S*-***** Water Heater Specifications (3.44 UEF)

In the 706-unit Hybrid/Electric Heat Pump class, JETGLAS RE2H50S*-***** (Electric) achieves a certified 3.44 UEF rating across its 45-gallon nominal tank, 65 gal First Hour Rating (rank #622 of 706, PD 2408604) and verifies as Pass: +1.14 / +49.6% for 2029 DOE floors. Rated annual electricity draw of 944 kWh/yr equates to roughly $171/yr ($1,714 over 10 years) at 18.16 cents/kWh. Closest certified alternative is Bradford White RE2H50S*-***** (3.44 UEF).

Uniform Energy Factor
3.44 UEF
Cohort UEF Rank
#622 of 706
First Hour Rating
65 gal
Storage Volume
45 gal
Fuel / Type
Electric / Hybrid/Electric Heat Pump
DOE 2029 Rule Status
Pass: +1.14 / +49.6%
Hybrid heat pump water heater upper shroud with brass relief valve and insulated copper risers
Hybrid heat pump water heater upper shroud with brass relief valve and insulated copper risers
Hybrid/Electric Heat Pump UEF Efficiency Distribution (706 Certified Units)Distribution of certified UEF ratings across 706 units in Hybrid/Electric Heat Pump, marking JETGLAS RE2H50S*-***** at 3.44 UEF.21130201631342031241542.52 UEF4.50 UEFMedian 3.702029 min 2.30JETGLAS RE2H50S*-*****: 3.44
Hybrid/Electric Heat Pump UEF Efficiency Distribution (706 Certified Units). Highlighted pin shows JETGLAS RE2H50S*-***** relative to the cohort median.
Efficiency comparison & rule summary

JETGLAS RE2H50S*-***** records 3.44 UEF efficiency, putting it #622 of 706 among 706 Hybrid/Electric Heat Pump peers.

10 CFR 430.32(d)(2) compliance: JETGLAS RE2H50S*-***** exceeds 10 CFR 430.32(d)(2) Electric >35 to <=55 gal (2.30 UEF) by +1.14 UEF (+49.6%). At EIA August 2026 national rates (18.16 cents/kWh), 944 kWh/yr for JETGLAS RE2H50S*-***** runs ~$171/yr vs. ~$641/yr for a 0.92 UEF electric tank.

State electric sensitivity for JETGLAS RE2H50S*-*****: 10-year operating spend spans $1,381 in Washington (Lowest Hydro Tier) (14.63 cents/kWh) to $4,454 in Hawaii (Highest EIA State) (47.18 cents/kWh).

Competing options beside JETGLAS RE2H50S*-***** (3.44 UEF) are Bradford White RE2H50S*-***** (3.44 UEF, at parity) and Friedrich PROH50 T2 FD310BM (3.5 UEF, delta +0.06).

Which Specs Set JETGLAS RE2H50S*-***** Apart From Cohort Averages?

Ranked #622 of 706 inside the 706-model Hybrid/Electric Heat Pump cohort, JETGLAS RE2H50S*-***** is evaluated row by row below against category medians.

Certified model attributes compared against 706 ENERGY STAR Hybrid/Electric Heat Pump peers
Specification AttributeCertified ValueCohort Benchmark / DeltaProvenance
Manufacturer / BrandJETGLAS6 certified listingsENERGY STAR PD 2408604
Model NumberRE2H50S*-*****Draw pattern: Medium-UsageRE2H50S*-*****
Uniform Energy Factor (UEF)3.44-0.26 UEF vs. 3.70 UEF median10 CFR 430 Test Method
First Hour Rating (FHR)65 gal-7 gal vs. 72 gal median10 CFR 430 Recovery Test
Rated Annual Electricity Use944 kWh/yr-128 kWh/yr vs. 1,072 kWh/yr medianEst. $171/yr @ $0.1816/kWh (EIA US Avg)
Thermal Recovery Efficiency406%-23.0 pts vs. 429.0% medianENERGY STAR Dataset
Physical Envelope (H x Dia)45.3" H x 18" DFits standard 72 in. basement/garage clearance; clears 28 in. utility doorway (18" D)Doorway & ceiling check
Electrical Circuit Requirements240 V / 19 A maxRequires 240V dedicated branch circuit; check panel capacityNEC / Branch circuit check
Heat Pump Refrigerant & GWPR-134a (GWP:1430)Check regional AIM Act phase-down transitionEPA AIM Act Compliance
Certification Date2023-02-23Certified 2023-02-23Markets: United States

How Do Regional kWh Prices Impact RE2H50S*-***** Over 10 Years?

Using EIA Table 5.6.A benchmarks, JETGLAS RE2H50S*-*****'s 944 kWh/yr draw translates to roughly $171/yr on typical US residential bills.

Estimated Annual Electricity Cost by State Rate (944 kWh/yr)Projected annual electricity spend across five benchmark EIA August 2026 residential electric tiers.United States Average$171.00/yrHawaii$445.00/yrCalifornia$281.00/yrTexas$150.00/yrWashington$138.00/yr
Projected annual electricity spend across five benchmark EIA August 2026 residential electric tiers.
Estimated electricity cost and 10-year spend across benchmark states
Jurisdiction (EIA Aug 2026)Residential RateAnnual Cost10-Yr Operating Spend10-Yr Savings vs. 0.92 UEF
United States Average 18.16 ¢/kWh ($0.1816) $171/yr $1,714 $4,696
Hawaii (Highest EIA State) 47.18 ¢/kWh ($0.4718) $445/yr $4,454 $12,201
California 29.75 ¢/kWh ($0.2975) $281/yr $2,808 $7,693
Texas 15.91 ¢/kWh ($0.1591) $150/yr $1,502 $4,114
Washington (Lowest Hydro Tier) 14.63 ¢/kWh ($0.1463) $138/yr $1,381 $3,783
Estimated electricity spend (944 kWh/yr)

Condensing Gas Tankless vs. Storage Tank Flow Path & Gas Supply Engineering schematic contrasting 199,000 BTU/h condensing tankless piping (3/4 in. gas supply, Category IV PVC vent, condensate drain) against a 40,000 BTU/h atmospheric tank. Condensing Gas Tankless (0.91–0.96 UEF) Secondary HX Cat IV PVC Vent Cold In Hot Out 3/4"–1" Gas 199K BTU/h Condensate Atmospheric Storage Tank (0.58–0.65 UEF) Type B Flue Anode Rod 40K BTU/h 1/2" Gas Up to 100 ft T&P 150 psi 50–85 gal FHR Reserve | 8–12 yr life
Technical comparison: condensing gas tankless units require 3/4 in.–1 in. IFGC Table 402.4 gas supply and Category IV condensate drainage, while atmospheric tanks run on 1/2 in. lines.

What Should JETGLAS Owners Check in CPSC Recall Logs?

The 2026-11-23 CPSC recall sweep recorded zero brand matches for JETGLAS; run a quick serial-number check to verify age before replacing wear parts. See Serial Number Lookup.

How Do Five Nearby Hybrid/Electric Heat Pump Models Stack Up?

Five alternative Hybrid/Electric Heat Pump units with nearly identical gallon storage and UEF scores are listed below alongside exact efficiency spreads.

5 closest certified peers matched by equipment class, storage volume, and efficiency rating
Brand & ModelTypeVolFHRUEF (Δ)kWh/yr
Bradford White RE2H50S*-***** Hybrid/Electric Heat Pump 45 gal 65 gal 3.44 (at parity) 944
Friedrich PROH50 T2 FD310BM Hybrid/Electric Heat Pump 45 gal 67 gal 3.5 (+0.06) 915
Rheem CPROPH50 T2 RH350BM Hybrid/Electric Heat Pump 45 gal 67 gal 3.5 (+0.06) 915
Ruud PRO H50 T2 RU310BM Hybrid/Electric Heat Pump 45 gal 67 gal 3.5 (+0.06) 915
Friedrich PROH50 T2 FD310UM Hybrid/Electric Heat Pump 45 gal 67 gal 3.5 (+0.06) 915

What Installation Caveats Apply Before Buying JETGLAS RE2H50S*-*****?

Even high-UEF units like JETGLAS RE2H50S*-***** (3.44 UEF) carry physical space, condensate, and fuel-line prerequisites noted below.

Key Limitations & Exclusions

  • JETGLAS RE2H50S*-***** needs >=450 cu ft room air volume or ducting so compressor cooling does not stall recovery.
  • Compressor runs near 49 dBA; avoid mounting JETGLAS RE2H50S*-***** directly beside quiet bedrooms.
  • Requires condensate drain routing and 240V electrical capacity; verify state DOE HEAR status.

Which Option Fits Your Situation?

High Electric Rate States Choosing JETGLAS RE2H50S*-***** Strong Fit — 3.44 UEF trims electric use ~75% vs 0.92 UEF tanks.
Open Basement or Garage (>=450 cu ft) Strong Fit — Ample ambient air sustains heat-pump-only efficiency.
Small Interior Closet (<300 cu ft) Caution — Add duct kit or compare Bradford White RE2H50S*-***** footprint.

Frequently Asked Technical Questions: JETGLAS RE2H50S*-*****

Direct answers to common technical, regulatory, and sizing questions sourced from primary U.S. government and OEM documentation.

Is JETGLAS RE2H50S*-***** eligible for continued manufacture past May 6, 2029?

At 3.44 UEF, JETGLAS RE2H50S*-***** achieves Pass: +1.14 / +49.6% for the 2029 DOE standard and stands #622 of 706 against Bradford White RE2H50S*-***** and Friedrich PROH50 T2 FD310BM.

How tall and wide is JETGLAS RE2H50S*-*****, and what service clearance is needed?

Physical dimensions for JETGLAS RE2H50S*-***** are 45.3 in. height and 18 in. diameter (fits standard 72 in. basement/garage clearance; clears 28 in. utility doorway (18" d)); verify stair turns and drain pan width before delivery.

Will JETGLAS RE2H50S*-***** require upgrading household electrical panels or gas piping?

JETGLAS RE2H50S*-***** draws 240V at 19A max (Requires 240V dedicated branch circuit; check panel capacity); check whether existing 10/2 AWG 30A copper wiring aligns with nameplate amps.

Is JETGLAS RE2H50S*-***** economical to operate at 18.16 cents/kWh US electric rates?

Expect roughly $171/yr ($1,710 over 10 years) to power JETGLAS RE2H50S*-***** at 944 kWh/yr under the 18.16 cents/kWh US average (ranging from $138/yr in Washington hydro tiers up to $445/yr in Hawaii).

Which installation bottlenecks limit JETGLAS RE2H50S*-*****?

If ambient room air stays below 40 °F year-round or closet volume falls under 450 cu ft, JETGLAS RE2H50S*-***** drops into resistance mode more often.

How does JETGLAS RE2H50S*-***** handle simultaneous showers and laundry?

Delivering 65 gal in the first hour (-7 gal vs. 72 gal median), JETGLAS RE2H50S*-***** combines 45 gal tank storage with rapid burner/element recovery.

How long is the warranty on JETGLAS RE2H50S*-***** and how do you decode its serial?

CPSC records show 0 active plumbing recalls for JETGLAS as of 2026-11-23. Confirm install proof and serial manufacture year on JETGLAS RE2H50S*-***** before calling service.

How do 2026 post-OBBBA rebates affect buying JETGLAS RE2H50S*-*****?

Check state energy office HEAR portals and utility rebates in 2026 since federal 25C ended Dec 31, 2025. Closest peer in Hybrid/Electric Heat Pump is Bradford White RE2H50S*-***** (3.44 UEF).

Sources

  1. ENERGY STAR Certified Water Heaters Dataset (Socrata pbpq-swnu) — U.S. EPA & DOE ENERGY STAR, 2026 Live Certified Registry (retrieved 2026-11-23)
  2. 10 CFR 430.32 — Energy and Water Conservation Standards (Water Heaters & Plumbing Fixtures) — U.S. Department of Energy / eCFR, 2026 eCFR (incl. May 6, 2029 Rule) (retrieved 2026-11-23)
  3. CPSC SaferProducts.gov Product Recalls REST API — U.S. Consumer Product Safety Commission, 2026 Live Recalls Feed (retrieved 2026-11-23)
  4. EIA Electric Power Monthly Table 5.6.A — Average Residential Electricity Price by State — U.S. Energy Information Administration (EIA), August 2026 Monthly Release (retrieved 2026-11-23)

Related U.S. Metro Plumbing Benchmarks