Eco-Logical ECO-50HPM1A Water Heater Specifications (3.75 UEF)
Engineered as a Electric Hybrid/Electric Heat Pump unit, Eco-Logical ECO-50HPM1A achieves a certified 3.75 UEF rating across its 47-gallon nominal tank, 69 gal First Hour Rating and ranks #297 of 706 in its 706-model cohort (PD 3891797), recording Pass: +1.45 / +63.0% under 2029 DOE rules. Rated annual electricity draw of 855 kWh/yr equates to roughly $155/yr ($1,553 over 10 years) at 18.16 cents/kWh. Closest certified alternative is 1HVAC ACIQ-50G-HP-WH (3.75 UEF).
- Uniform Energy Factor
- 3.75 UEF
- Cohort UEF Rank
- #297 of 706
- First Hour Rating
- 69 gal
- Storage Volume
- 47 gal
- Fuel / Type
- Electric / Hybrid/Electric Heat Pump
- DOE 2029 Rule Status
- Pass: +1.45 / +63.0%

Within the 706-unit Hybrid/Electric Heat Pump cohort, Eco-Logical ECO-50HPM1A logs 3.75 UEF and ranks #297 of 706.
Against 10 CFR 430.32(d)(2) Electric >35 to <=55 gal (2.30 UEF), Eco-Logical ECO-50HPM1A holds a +1.45 UEF (+63.0%) compliance cushion. At EIA August 2026 national rates (18.16 cents/kWh), 855 kWh/yr for Eco-Logical ECO-50HPM1A runs ~$155/yr vs. ~$633/yr for a 0.92 UEF electric tank. Acoustic output is 49 dBA (quieter than 12.8% of Hybrid/Electric Heat Pump models).
State electric sensitivity for Eco-Logical ECO-50HPM1A: 10-year operating spend spans $1,251 in Washington (Lowest Hydro Tier) (14.63 cents/kWh) to $4,034 in Hawaii (Highest EIA State) (47.18 cents/kWh).
Cross-shopping Eco-Logical ECO-50HPM1A (3.75 UEF)? Check 1HVAC ACIQ-50G-HP-WH (3.75 UEF, at parity) and ACIQ ACIQ-50G-HP-WH (3.75 UEF, at parity).
How Do Eco-Logical ECO-50HPM1A Specs Compare to Hybrid/Electric Heat Pump Medians?
Eco-Logical ECO-50HPM1A places #297 of 706 across 706 certified Hybrid/Electric Heat Pump configurations, with physical dimensions, draw profile, and thermal metrics benchmarked below.
| Specification Attribute | Certified Value | Cohort Benchmark / Delta | Provenance |
|---|---|---|---|
| Manufacturer / Brand | Eco-Logical | 6 certified listings | ENERGY STAR PD 3891797 |
| Model Number | ECO-50HPM1A | Draw pattern: Medium-Usage | ECO-50HPM1A |
| Uniform Energy Factor (UEF) | 3.75 | +0.05 UEF vs. 3.70 UEF median | 10 CFR 430 Test Method |
| First Hour Rating (FHR) | 69 gal | -3 gal vs. 72 gal median | 10 CFR 430 Recovery Test |
| Rated Annual Electricity Use | 855 kWh/yr | -217 kWh/yr vs. 1,072 kWh/yr median | Est. $155/yr @ $0.1816/kWh (EIA US Avg) |
| Thermal Recovery Efficiency | 430% | +1.0 pts vs. 429.0% median | ENERGY STAR Dataset |
| Physical Envelope (H x Dia) | 47.9" H x 18.3" D | Fits standard 72 in. basement/garage clearance; clears 28 in. utility doorway (18.3" D) | Doorway & ceiling check |
| Electrical Circuit Requirements | 240 V / 24 A max | Requires 240V dedicated branch circuit; check panel capacity | NEC / Branch circuit check |
| Heat Pump Refrigerant & GWP | R-134a (GWP:1430) | Check regional AIM Act phase-down transition | EPA AIM Act Compliance |
| Sound Pressure Level | 49 dBA | quieter than 12.8% of Hybrid/Electric Heat Pump models · At 49 dBA median | Indoor placement check |
| Certification Date | 2024-12-19 | Certified 2024-12-19 | Markets: United States, Canada |
What Does ECO-50HPM1A Cost to Operate Across State Electricity Rates?
At 855 kWh/yr, Eco-Logical ECO-50HPM1A runs roughly $155/yr on the EIA national average tier under August 2026 Table 5.6.A rates.
| Jurisdiction (EIA Aug 2026) | Residential Rate | Annual Cost | 10-Yr Operating Spend | 10-Yr Savings vs. 0.92 UEF |
|---|---|---|---|---|
| United States Average | 18.16 ¢/kWh ($0.1816) | $155/yr | $1,553 | $4,776 |
| Hawaii (Highest EIA State) | 47.18 ¢/kWh ($0.4718) | $403/yr | $4,034 | $12,408 |
| California | 29.75 ¢/kWh ($0.2975) | $254/yr | $2,544 | $7,824 |
| Texas | 15.91 ¢/kWh ($0.1591) | $136/yr | $1,360 | $4,184 |
| Washington (Lowest Hydro Tier) | 14.63 ¢/kWh ($0.1463) | $125/yr | $1,251 | $3,848 |
Are There Active CPSC Safety Recalls for Eco-Logical Water Heaters?
Zero active CPSC recalls matched Eco-Logical in our 2026-11-23 SaferProducts sweep; verify your individual tank date code via our lookup tool. See Serial Number Lookup.
Which Certified Water Heaters Match ECO-50HPM1A Most Closely?
These 5 competing Hybrid/Electric Heat Pump units sit nearest to Eco-Logical ECO-50HPM1A by storage capacity and 3.75 UEF rating.
| Brand & Model | Type | Vol | FHR | UEF (Δ) | kWh/yr |
|---|---|---|---|---|---|
| 1HVAC ACIQ-50G-HP-WH | Hybrid/Electric Heat Pump | 47 gal | 69 gal | 3.75 (at parity) | 855 |
| ACIQ ACIQ-50G-HP-WH | Hybrid/Electric Heat Pump | 47 gal | 69 gal | 3.75 (at parity) | 855 |
| Bosch TR7000T - 50CA | Hybrid/Electric Heat Pump | 47 gal | 69 gal | 3.75 (at parity) | 855 |
| Custom Comfort CCOHPWH50A | Hybrid/Electric Heat Pump | 47 gal | 69 gal | 3.75 (at parity) | 855 |
| Bosch TR7000T - 50US | Hybrid/Electric Heat Pump | 47 gal | 69 gal | 3.75 (at parity) | 855 |
Who Is Eco-Logical ECO-50HPM1A Best For — and When Should You Pick 1HVAC ACIQ-50G-HP-WH?
Evaluate whether Eco-Logical ECO-50HPM1A's Hybrid/Electric Heat Pump architecture matches your existing mechanical room and local utility tariffs before purchasing.
Key Limitations & Exclusions
- Eco-Logical ECO-50HPM1A needs >=450 cu ft room air volume or ducting so compressor cooling does not stall recovery.
- Compressor runs near 49 dBA; avoid mounting Eco-Logical ECO-50HPM1A directly beside quiet bedrooms.
- Requires condensate drain routing and 240V electrical capacity; verify state DOE HEAR status.
Which Option Fits Your Situation?
What Are the Key Questions About Eco-Logical ECO-50HPM1A?
Direct answers to common technical, regulatory, and sizing questions sourced from primary U.S. government and OEM documentation.
How does Eco-Logical ECO-50HPM1A (3.75 UEF) compare to 2029 federal DOE floors?
Evaluated against May 6, 2029 10 CFR 430.32 thresholds, Eco-Logical ECO-50HPM1A records 3.75 UEF (Pass: +1.45 / +63.0%), placing #297 of 706 out of 706 certified Hybrid/Electric Heat Pump configurations.
Does Eco-Logical ECO-50HPM1A fit inside a tight hallway closet or low-headroom utility room?
Eco-Logical ECO-50HPM1A requires room for its 47.9 in. vertical shell and 18.3 in. diameter (fits standard 72 in. basement/garage clearance; clears 28 in. utility doorway (18.3" d)), plus service access for annual sediment draining.
What power supply or fuel line specs govern Eco-Logical ECO-50HPM1A?
For Eco-Logical ECO-50HPM1A, plan a 240V circuit at 24A max (Requires 240V dedicated branch circuit; check panel capacity) and keep a dedicated shutoff disconnect within sight of the unit.
What annual utility bill should homeowners budget for Eco-Logical ECO-50HPM1A?
Using 855 kWh/yr, Eco-Logical ECO-50HPM1A generates an estimated $155/yr electric bill at 18.16 cents/kWh (ranging from $125/yr in Washington hydro tiers up to $403/yr in Hawaii)—use the custom rate slider above for your utility tariff.
What are the main drawbacks of Eco-Logical ECO-50HPM1A (3.75 UEF)?
Eco-Logical ECO-50HPM1A requires >=450 cu ft air space, 240V electrical supply, and drain access; tight interior alcoves favor ducted adapters or 1HVAC ACIQ-50G-HP-WH.
What hot-water delivery rating governs Eco-Logical ECO-50HPM1A?
Rated for 69 gal FHR (-3 gal vs. 72 gal median), Eco-Logical ECO-50HPM1A prevents mid-morning cold drops when matched to 55–70+ gal multi-bath household loads.
Where do homeowners screen Eco-Logical ECO-50HPM1A for recalls and tank age?
Verified clean against 2026-11-23 CPSC recall feeds for Eco-Logical; use our browser-only serial decoder to inspect Eco-Logical ECO-50HPM1A's age and warranty window.
What alternative models sit closest to Eco-Logical ECO-50HPM1A in the Hybrid/Electric Heat Pump class?
Closest peer in Hybrid/Electric Heat Pump is 1HVAC ACIQ-50G-HP-WH (3.75 UEF). For 2026 incentives, look to state DOE HEAR grants ($1,750 max on qualifying HPWHs) and local municipal utility credits.
Sources
- ENERGY STAR Certified Water Heaters Dataset (Socrata pbpq-swnu) — U.S. EPA & DOE ENERGY STAR, 2026 Live Certified Registry (retrieved 2026-11-23)
- 10 CFR 430.32 — Energy and Water Conservation Standards (Water Heaters & Plumbing Fixtures) — U.S. Department of Energy / eCFR, 2026 eCFR (incl. May 6, 2029 Rule) (retrieved 2026-11-23)
- CPSC SaferProducts.gov Product Recalls REST API — U.S. Consumer Product Safety Commission, 2026 Live Recalls Feed (retrieved 2026-11-23)
- EIA Electric Power Monthly Table 5.6.A — Average Residential Electricity Price by State — U.S. Energy Information Administration (EIA), August 2026 Monthly Release (retrieved 2026-11-23)