Skip to main content
ENERGY STAR water heater model · PD 3845907

Friedrich PROH50 T0 FD120-M Water Heater Specifications (3 UEF)

Engineered as a Electric Hybrid/Electric Heat Pump unit, Friedrich PROH50 T0 FD120-M achieves a certified 3.0 UEF rating across its 46-gallon nominal tank, 55 gal First Hour Rating and ranks #666 of 706 in its 706-model cohort (PD 3845907), recording Pass: +0.70 / +30.4% under 2029 DOE rules. Rated annual electricity draw of 1,072 kWh/yr equates to roughly $195/yr ($1,947 over 10 years) at 18.16 cents/kWh. Closest certified alternative is Rheem PROPH50 T0 RH120-M (3.0 UEF).

Uniform Energy Factor
3.0 UEF
Cohort UEF Rank
#666 of 706
First Hour Rating
55 gal
Storage Volume
46 gal
Fuel / Type
Electric / Hybrid/Electric Heat Pump
DOE 2029 Rule Status
Pass: +0.70 / +30.4%
Hybrid heat pump water heater upper shroud with brass relief valve and insulated copper risers
Hybrid heat pump water heater upper shroud with brass relief valve and insulated copper risers
Hybrid/Electric Heat Pump UEF Efficiency Distribution (706 Certified Units)Distribution of certified UEF ratings across 706 units in Hybrid/Electric Heat Pump, marking Friedrich PROH50 T0 FD120-M at 3.0 UEF.21130201631342031241542.52 UEF4.50 UEFMedian 3.702029 min 2.30Friedrich PROH50 T0 FD120-M: 3.00
Hybrid/Electric Heat Pump UEF Efficiency Distribution (706 Certified Units). Highlighted pin shows Friedrich PROH50 T0 FD120-M relative to the cohort median.
Efficiency comparison & rule summary

Within the 706-unit Hybrid/Electric Heat Pump cohort, Friedrich PROH50 T0 FD120-M logs 3.0 UEF and ranks #666 of 706.

Against 10 CFR 430.32(d)(2) Electric >35 to <=55 gal (2.30 UEF), Friedrich PROH50 T0 FD120-M holds a +0.70 UEF (+30.4%) compliance cushion. At EIA August 2026 national rates (18.16 cents/kWh), 1,072 kWh/yr for Friedrich PROH50 T0 FD120-M runs ~$195/yr vs. ~$635/yr for a 0.92 UEF electric tank.

State electric sensitivity for Friedrich PROH50 T0 FD120-M: 10-year operating spend spans $1,568 in Washington (Lowest Hydro Tier) (14.63 cents/kWh) to $5,058 in Hawaii (Highest EIA State) (47.18 cents/kWh).

Cross-shopping Friedrich PROH50 T0 FD120-M (3.0 UEF)? Check Rheem PROPH50 T0 RH120-M (3.0 UEF, at parity) and Richmond 10E50-HP120M (3.0 UEF, at parity).

Which Specs Set Friedrich PROH50 T0 FD120-M Apart From Cohort Averages?

Ranked #666 of 706 inside the 706-model Hybrid/Electric Heat Pump cohort, Friedrich PROH50 T0 FD120-M is evaluated row by row below against category medians.

Certified model attributes compared against 706 ENERGY STAR Hybrid/Electric Heat Pump peers
Specification AttributeCertified ValueCohort Benchmark / DeltaProvenance
Manufacturer / BrandFriedrich61 certified listingsENERGY STAR PD 3845907
Model NumberPROH50 T0 FD120-MDraw pattern: Medium-UsagePROH50 T0 FD120-M
Uniform Energy Factor (UEF)3.0-0.70 UEF vs. 3.70 UEF median10 CFR 430 Test Method
First Hour Rating (FHR)55 gal-17 gal vs. 72 gal median10 CFR 430 Recovery Test
Rated Annual Electricity Use1,072 kWh/yrAt 1,072 kWh/yr medianEst. $195/yr @ $0.1816/kWh (EIA US Avg)
Thermal Recovery Efficiency367%-62.0 pts vs. 429.0% medianENERGY STAR Dataset
Physical Envelope (H x Dia)45.3" H x 18" DFits standard 72 in. basement/garage clearance; clears 28 in. utility doorway (18" D)Doorway & ceiling check
Electrical Circuit Requirements120 V / 4.5 A max120V plug-in retrofit circuit; slower heat-pump-only recoveryNEC / Branch circuit check
Heat Pump Refrigerant & GWPR-134a (GWP:1430)Check regional AIM Act phase-down transitionEPA AIM Act Compliance
Certification Date2026-10-16Certified 2026-10-16Markets: United States

How Do Regional kWh Prices Impact PROH50 T0 FD120-M Over 10 Years?

Using EIA Table 5.6.A benchmarks, Friedrich PROH50 T0 FD120-M's 1,072 kWh/yr draw translates to roughly $195/yr on typical US residential bills.

Estimated Annual Electricity Cost by State Rate (1,072 kWh/yr)Projected annual electricity spend across five benchmark EIA August 2026 residential electric tiers.United States Average$195.00/yrHawaii$506.00/yrCalifornia$319.00/yrTexas$171.00/yrWashington$157.00/yr
Projected annual electricity spend across five benchmark EIA August 2026 residential electric tiers.
Estimated electricity cost and 10-year spend across benchmark states
Jurisdiction (EIA Aug 2026)Residential RateAnnual Cost10-Yr Operating Spend10-Yr Savings vs. 0.92 UEF
United States Average 18.16 ¢/kWh ($0.1816) $195/yr $1,947 $4,402
Hawaii (Highest EIA State) 47.18 ¢/kWh ($0.4718) $506/yr $5,058 $11,436
California 29.75 ¢/kWh ($0.2975) $319/yr $3,189 $7,211
Texas 15.91 ¢/kWh ($0.1591) $171/yr $1,706 $3,857
Washington (Lowest Hydro Tier) 14.63 ¢/kWh ($0.1463) $157/yr $1,568 $3,546
Estimated electricity spend (1,072 kWh/yr)

Condensing Gas Tankless vs. Storage Tank Flow Path & Gas Supply Engineering schematic contrasting 199,000 BTU/h condensing tankless piping (3/4 in. gas supply, Category IV PVC vent, condensate drain) against a 40,000 BTU/h atmospheric tank. Condensing Gas Tankless (0.91–0.96 UEF) Secondary HX Cat IV PVC Vent Cold In Hot Out 3/4"–1" Gas 199K BTU/h Condensate Atmospheric Storage Tank (0.58–0.65 UEF) Type B Flue Anode Rod 40K BTU/h 1/2" Gas Up to 100 ft T&P 150 psi 50–85 gal FHR Reserve | 8–12 yr life
Technical comparison: condensing gas tankless units require 3/4 in.–1 in. IFGC Table 402.4 gas supply and Category IV condensate drainage, while atmospheric tanks run on 1/2 in. lines.

What Should Friedrich Owners Check in CPSC Recall Logs?

The 2026-11-23 CPSC recall sweep recorded zero brand matches for Friedrich; run a quick serial-number check to verify age before replacing wear parts. See Serial Number Lookup.

How Do Five Nearby Hybrid/Electric Heat Pump Models Stack Up?

Five alternative Hybrid/Electric Heat Pump units with nearly identical gallon storage and UEF scores are listed below alongside exact efficiency spreads.

5 closest certified peers matched by equipment class, storage volume, and efficiency rating
Brand & ModelTypeVolFHRUEF (Δ)kWh/yr
Rheem PROPH50 T0 RH120-M Hybrid/Electric Heat Pump 46 gal 55 gal 3.0 (at parity) 1,072
Richmond 10E50-HP120M Hybrid/Electric Heat Pump 46 gal 55 gal 3.0 (at parity) 1,072
Ruud PROUH50 T0 RU120-M Hybrid/Electric Heat Pump 46 gal 55 gal 3.0 (at parity) 1,072
A. O. Smith HPTV-50 2** Hybrid/Electric Heat Pump 46 gal 52 gal 3.0 (at parity) 1,550
Rheem PROPH50 T0 RH120-MSO Hybrid/Electric Heat Pump 46 gal 55 gal 3.0 (at parity) 1,072

When Should Homeowners Skip Friedrich PROH50 T0 FD120-M (Hybrid/Electric Heat Pump)?

Check Friedrich PROH50 T0 FD120-M's mechanical constraints—including utility space, Electric capacity, and Pass: +0.70 / +30.4% status—against typical residential installations.

Key Limitations & Exclusions

  • Friedrich PROH50 T0 FD120-M needs >=450 cu ft room air volume or ducting so compressor cooling does not stall recovery.
  • Compressor runs near 49 dBA; avoid mounting Friedrich PROH50 T0 FD120-M directly beside quiet bedrooms.
  • Requires condensate drain routing and 120V electrical capacity; verify state DOE HEAR status.

Which Option Fits Your Situation?

High Electric Rate States Choosing Friedrich PROH50 T0 FD120-M Strong Fit — 3.0 UEF trims electric use ~75% vs 0.92 UEF tanks.
Open Basement or Garage (>=450 cu ft) Strong Fit — Ample ambient air sustains heat-pump-only efficiency.
Small Interior Closet (<300 cu ft) Caution — Add duct kit or compare Rheem PROPH50 T0 RH120-M footprint.

Frequently Asked Technical Questions: Friedrich PROH50 T0 FD120-M

Direct answers to common technical, regulatory, and sizing questions sourced from primary U.S. government and OEM documentation.

Will Friedrich PROH50 T0 FD120-M stay compliant after the May 6, 2029 DOE standard takes effect?

Tested at 3.0 UEF, Friedrich PROH50 T0 FD120-M shows Pass: +0.70 / +30.4% relative to May 6, 2029 federal DOE limits while placing #666 of 706 among 706 Hybrid/Electric Heat Pump peers like Rheem PROPH50 T0 RH120-M.

Will Friedrich PROH50 T0 FD120-M fit through a standard utility door and 72-inch basement ceiling?

Measuring 45.3 in. tall by 18 in. diameter, Friedrich PROH50 T0 FD120-M notes: fits standard 72 in. basement/garage clearance; clears 28 in. utility doorway (18" d). Reserve space above the jacket for T&P piping and anode removal.

Do existing utility hookups support Friedrich PROH50 T0 FD120-M during replacement?

Electrical specs for Friedrich PROH50 T0 FD120-M call for 120V at 4.5A max (120V plug-in retrofit circuit; slower heat-pump-only recovery). Have a licensed electrician inspect panel load and wire gauge.

What is the estimated 10-year operating spend for Friedrich PROH50 T0 FD120-M?

At 18.16 cents/kWh national residential pricing, Friedrich PROH50 T0 FD120-M's 1,072 kWh/yr draw equals roughly $195 annually or $1,950 across a 10-year horizon (ranging from $157/yr in Washington hydro tiers up to $506/yr in Hawaii).

When is Friedrich PROH50 T0 FD120-M a poor fit for a residential replacement?

Avoid placing Friedrich PROH50 T0 FD120-M directly next to bedrooms or inside tight <300 cu ft closets without ducting, due to 49 dBA sound and cool exhaust airflow.

What First Hour Rating or flow capacity does Friedrich PROH50 T0 FD120-M deliver?

With 55 gal FHR (-17 gal vs. 72 gal median), Friedrich PROH50 T0 FD120-M fits 1–3 person or moderate-draw homes cleanly.

How do you verify manufacturing age and recall status on Friedrich PROH50 T0 FD120-M?

Our 2026-11-23 CPSC SaferProducts feed lists zero recalls for Friedrich; verify exact manufacturing week for Friedrich PROH50 T0 FD120-M using the Serial Number Lookup tool.

Does Friedrich PROH50 T0 FD120-M qualify for DOE HEAR incentives after 25C expired?

After 25C sunset on Dec 31, 2025 under OBBBA, check state DOE HEAR (up to $1,750 income-qualified) and utility rebates for Friedrich PROH50 T0 FD120-M. Closest peer in Hybrid/Electric Heat Pump is Rheem PROPH50 T0 RH120-M (3.0 UEF).

Sources

  1. ENERGY STAR Certified Water Heaters Dataset (Socrata pbpq-swnu) — U.S. EPA & DOE ENERGY STAR, 2026 Live Certified Registry (retrieved 2026-11-23)
  2. 10 CFR 430.32 — Energy and Water Conservation Standards (Water Heaters & Plumbing Fixtures) — U.S. Department of Energy / eCFR, 2026 eCFR (incl. May 6, 2029 Rule) (retrieved 2026-11-23)
  3. CPSC SaferProducts.gov Product Recalls REST API — U.S. Consumer Product Safety Commission, 2026 Live Recalls Feed (retrieved 2026-11-23)
  4. EIA Electric Power Monthly Table 5.6.A — Average Residential Electricity Price by State — U.S. Energy Information Administration (EIA), August 2026 Monthly Release (retrieved 2026-11-23)

Related U.S. Metro Plumbing Benchmarks