Skip to main content
ENERGY STAR water heater model · PD 3555176

Richmond 10E50-HP120M Water Heater Specifications (3 UEF)

Certified at 3.0 UEF across its 46-gallon nominal tank, 55 gal First Hour Rating, Richmond 10E50-HP120M (Hybrid/Electric Heat Pump, Electric) places #666 of 706 out of 706 ENERGY STAR models (PD 3555176). Its May 6, 2029 10 CFR 430.32 status reads Pass: +0.70 / +30.4%. Rated annual electricity draw of 1,072 kWh/yr equates to roughly $195/yr ($1,947 over 10 years) at 18.16 cents/kWh. Closest certified alternative is Friedrich PROH50 T0 FD120-M (3.0 UEF).

Uniform Energy Factor
3.0 UEF
Cohort UEF Rank
#666 of 706
First Hour Rating
55 gal
Storage Volume
46 gal
Fuel / Type
Electric / Hybrid/Electric Heat Pump
DOE 2029 Rule Status
Pass: +0.70 / +30.4%
Hybrid heat pump water heater upper shroud with brass relief valve and insulated copper risers
Hybrid heat pump water heater upper shroud with brass relief valve and insulated copper risers
Hybrid/Electric Heat Pump UEF Efficiency Distribution (706 Certified Units)Distribution of certified UEF ratings across 706 units in Hybrid/Electric Heat Pump, marking Richmond 10E50-HP120M at 3.0 UEF.21130201631342031241542.52 UEF4.50 UEFMedian 3.702029 min 2.30Richmond 10E50-HP120M: 3.00
Hybrid/Electric Heat Pump UEF Efficiency Distribution (706 Certified Units). Highlighted pin shows Richmond 10E50-HP120M relative to the cohort median.
Efficiency comparison & rule summary

Tested at 3.0 UEF, Richmond 10E50-HP120M places #666 of 706 across 706 certified Hybrid/Electric Heat Pump configurations (-0.70 UEF vs. 3.70 UEF median).

Richmond 10E50-HP120M clears 10 CFR 430.32(d)(2) Electric >35 to <=55 gal (2.30 UEF) by +0.70 UEF (+30.4% headroom). At EIA August 2026 national rates (18.16 cents/kWh), 1,072 kWh/yr for Richmond 10E50-HP120M runs ~$195/yr vs. ~$635/yr for a 0.92 UEF electric tank.

State electric sensitivity for Richmond 10E50-HP120M: 10-year operating spend spans $1,568 in Washington (Lowest Hydro Tier) (14.63 cents/kWh) to $5,058 in Hawaii (Highest EIA State) (47.18 cents/kWh).

Closest alternatives to Richmond 10E50-HP120M include Friedrich PROH50 T0 FD120-M (3.0 UEF, at parity) alongside Rheem PROPH50 T0 RH120-M (3.0 UEF, at parity).

What Physical and Thermal Ratings Define Richmond 10E50-HP120M?

Positioning at #666 of 706 out of 706 Hybrid/Electric Heat Pump peers, Richmond 10E50-HP120M pairs measured UEF performance with specific clearance and wiring rules.

Certified model attributes compared against 706 ENERGY STAR Hybrid/Electric Heat Pump peers
Specification AttributeCertified ValueCohort Benchmark / DeltaProvenance
Manufacturer / BrandRichmond80 certified listingsENERGY STAR PD 3555176
Model Number10E50-HP120MDraw pattern: Medium-Usage10E50-HP120M
Uniform Energy Factor (UEF)3.0-0.70 UEF vs. 3.70 UEF median10 CFR 430 Test Method
First Hour Rating (FHR)55 gal-17 gal vs. 72 gal median10 CFR 430 Recovery Test
Rated Annual Electricity Use1,072 kWh/yrAt 1,072 kWh/yr medianEst. $195/yr @ $0.1816/kWh (EIA US Avg)
Thermal Recovery Efficiency367%-62.0 pts vs. 429.0% medianENERGY STAR Dataset
Physical Envelope (H x Dia)61.8" H x 22.3" DFits standard 72 in. basement/garage clearance; clears 28 in. utility doorway (22.3" D)Doorway & ceiling check
Electrical Circuit Requirements120 V / 4.5 A max120V plug-in retrofit circuit; slower heat-pump-only recoveryNEC / Branch circuit check
Heat Pump Refrigerant & GWPR-134a (GWP:1430)Check regional AIM Act phase-down transitionEPA AIM Act Compliance
Certification Date2026-10-16Certified 2026-10-16Markets: United States

Why Do State Utility Rates Shift 10E50-HP120M Running Costs?

Consuming 1,072 kWh annually puts Richmond 10E50-HP120M near $195/yr at US baseline tariffs, with multi-state EIA comparisons charted below.

Estimated Annual Electricity Cost by State Rate (1,072 kWh/yr)Projected annual electricity spend across five benchmark EIA August 2026 residential electric tiers.United States Average$195.00/yrHawaii$506.00/yrCalifornia$319.00/yrTexas$171.00/yrWashington$157.00/yr
Projected annual electricity spend across five benchmark EIA August 2026 residential electric tiers.
Estimated electricity cost and 10-year spend across benchmark states
Jurisdiction (EIA Aug 2026)Residential RateAnnual Cost10-Yr Operating Spend10-Yr Savings vs. 0.92 UEF
United States Average 18.16 ¢/kWh ($0.1816) $195/yr $1,947 $4,402
Hawaii (Highest EIA State) 47.18 ¢/kWh ($0.4718) $506/yr $5,058 $11,436
California 29.75 ¢/kWh ($0.2975) $319/yr $3,189 $7,211
Texas 15.91 ¢/kWh ($0.1591) $171/yr $1,706 $3,857
Washington (Lowest Hydro Tier) 14.63 ¢/kWh ($0.1463) $157/yr $1,568 $3,546
Estimated electricity spend (1,072 kWh/yr)

Condensing Gas Tankless vs. Storage Tank Flow Path & Gas Supply Engineering schematic contrasting 199,000 BTU/h condensing tankless piping (3/4 in. gas supply, Category IV PVC vent, condensate drain) against a 40,000 BTU/h atmospheric tank. Condensing Gas Tankless (0.91–0.96 UEF) Secondary HX Cat IV PVC Vent Cold In Hot Out 3/4"–1" Gas 199K BTU/h Condensate Atmospheric Storage Tank (0.58–0.65 UEF) Type B Flue Anode Rod 40K BTU/h 1/2" Gas Up to 100 ft T&P 150 psi 50–85 gal FHR Reserve | 8–12 yr life
Technical comparison: condensing gas tankless units require 3/4 in.–1 in. IFGC Table 402.4 gas supply and Category IV condensate drainage, while atmospheric tanks run on 1/2 in. lines.

Have Any Richmond Series Triggered CPSC Recalls?

SaferProducts screening on 2026-11-23 returned zero recall matches for Richmond; confirm tank age separately using the rating-plate serial pattern. See Serial Number Lookup.

What Are 5 Direct Alternatives to Richmond 10E50-HP120M?

Homeowners cross-shopping Richmond 10E50-HP120M frequently review these five Hybrid/Electric Heat Pump models ranked closest on capacity and UEF output.

5 closest certified peers matched by equipment class, storage volume, and efficiency rating
Brand & ModelTypeVolFHRUEF (Δ)kWh/yr
Friedrich PROH50 T0 FD120-M Hybrid/Electric Heat Pump 46 gal 55 gal 3.0 (at parity) 1,072
Rheem PROPH50 T0 RH120-M Hybrid/Electric Heat Pump 46 gal 55 gal 3.0 (at parity) 1,072
Ruud PROUH50 T0 RU120-M Hybrid/Electric Heat Pump 46 gal 55 gal 3.0 (at parity) 1,072
A. O. Smith HPTV-50 2** Hybrid/Electric Heat Pump 46 gal 52 gal 3.0 (at parity) 1,550
Friedrich PROH50 T0 FD120-MSO Hybrid/Electric Heat Pump 46 gal 55 gal 3.0 (at parity) 1,072

When Should Homeowners Skip Richmond 10E50-HP120M (Hybrid/Electric Heat Pump)?

Check Richmond 10E50-HP120M's mechanical constraints—including utility space, Electric capacity, and Pass: +0.70 / +30.4% status—against typical residential installations.

Key Limitations & Exclusions

  • Richmond 10E50-HP120M needs >=450 cu ft room air volume or ducting so compressor cooling does not stall recovery.
  • Compressor runs near 49 dBA; avoid mounting Richmond 10E50-HP120M directly beside quiet bedrooms.
  • Requires condensate drain routing and 120V electrical capacity; verify state DOE HEAR status.

Which Option Fits Your Situation?

High Electric Rate States Choosing Richmond 10E50-HP120M Strong Fit — 3.0 UEF trims electric use ~75% vs 0.92 UEF tanks.
Open Basement or Garage (>=450 cu ft) Strong Fit — Ample ambient air sustains heat-pump-only efficiency.
Small Interior Closet (<300 cu ft) Caution — Add duct kit or compare Friedrich PROH50 T0 FD120-M footprint.

Sizing, Efficiency & Recall Answers for Richmond 10E50-HP120M

Direct answers to common technical, regulatory, and sizing questions sourced from primary U.S. government and OEM documentation.

Will Richmond 10E50-HP120M stay compliant after the May 6, 2029 DOE standard takes effect?

Tested at 3.0 UEF, Richmond 10E50-HP120M shows Pass: +0.70 / +30.4% relative to May 6, 2029 federal DOE limits while placing #666 of 706 among 706 Hybrid/Electric Heat Pump peers like Friedrich PROH50 T0 FD120-M.

Will Richmond 10E50-HP120M fit through a standard utility door and 72-inch basement ceiling?

Measuring 61.8 in. tall by 22.3 in. diameter, Richmond 10E50-HP120M notes: fits standard 72 in. basement/garage clearance; clears 28 in. utility doorway (22.3" d). Reserve space above the jacket for T&P piping and anode removal.

Do existing utility hookups support Richmond 10E50-HP120M during replacement?

Electrical specs for Richmond 10E50-HP120M call for 120V at 4.5A max (120V plug-in retrofit circuit; slower heat-pump-only recovery). Have a licensed electrician inspect panel load and wire gauge.

What is the estimated 10-year operating spend for Richmond 10E50-HP120M?

At 18.16 cents/kWh national residential pricing, Richmond 10E50-HP120M's 1,072 kWh/yr draw equals roughly $195 annually or $1,950 across a 10-year horizon (ranging from $157/yr in Washington hydro tiers up to $506/yr in Hawaii).

When is Richmond 10E50-HP120M a poor fit for a residential replacement?

Avoid placing Richmond 10E50-HP120M directly next to bedrooms or inside tight <300 cu ft closets without ducting, due to 49 dBA sound and cool exhaust airflow.

What First Hour Rating or flow capacity does Richmond 10E50-HP120M deliver?

With 55 gal FHR (-17 gal vs. 72 gal median), Richmond 10E50-HP120M fits 1–3 person or moderate-draw homes cleanly.

How do you verify manufacturing age and recall status on Richmond 10E50-HP120M?

Our 2026-11-23 CPSC SaferProducts feed lists zero recalls for Richmond; verify exact manufacturing week for Richmond 10E50-HP120M using the Serial Number Lookup tool.

Does Richmond 10E50-HP120M qualify for DOE HEAR incentives after 25C expired?

After 25C sunset on Dec 31, 2025 under OBBBA, check state DOE HEAR (up to $1,750 income-qualified) and utility rebates for Richmond 10E50-HP120M. Closest peer in Hybrid/Electric Heat Pump is Friedrich PROH50 T0 FD120-M (3.0 UEF).

Sources

  1. ENERGY STAR Certified Water Heaters Dataset (Socrata pbpq-swnu) — U.S. EPA & DOE ENERGY STAR, 2026 Live Certified Registry (retrieved 2026-11-23)
  2. 10 CFR 430.32 — Energy and Water Conservation Standards (Water Heaters & Plumbing Fixtures) — U.S. Department of Energy / eCFR, 2026 eCFR (incl. May 6, 2029 Rule) (retrieved 2026-11-23)
  3. CPSC SaferProducts.gov Product Recalls REST API — U.S. Consumer Product Safety Commission, 2026 Live Recalls Feed (retrieved 2026-11-23)
  4. EIA Electric Power Monthly Table 5.6.A — Average Residential Electricity Price by State — U.S. Energy Information Administration (EIA), August 2026 Monthly Release (retrieved 2026-11-23)

Related U.S. Metro Plumbing Benchmarks