Skip to main content
ENERGY STAR water heater model · PD 3555170

Rheem PROPH50 T0 RH120-M Water Heater Specifications (3 UEF)

The Rheem PROPH50 T0 RH120-M (Hybrid/Electric Heat Pump, Electric) achieves a certified 3.0 UEF rating across its 46-gallon nominal tank, 55 gal First Hour Rating, ranking #666 of 706 among 706 ENERGY STAR Hybrid/Electric Heat Pump models (PD 3555170). Under the May 6, 2029 DOE 10 CFR 430.32(d)(2) standard, compliance status is Pass: +0.70 / +30.4%. Rated annual electricity draw of 1,072 kWh/yr equates to roughly $195/yr ($1,947 over 10 years) at 18.16 cents/kWh. Closest certified alternative is Friedrich PROH50 T0 FD120-M (3.0 UEF).

Uniform Energy Factor
3.0 UEF
Cohort UEF Rank
#666 of 706
First Hour Rating
55 gal
Storage Volume
46 gal
Fuel / Type
Electric / Hybrid/Electric Heat Pump
DOE 2029 Rule Status
Pass: +0.70 / +30.4%
Hybrid heat pump water heater upper shroud with brass relief valve and insulated copper risers
Hybrid heat pump water heater upper shroud with brass relief valve and insulated copper risers
Hybrid/Electric Heat Pump UEF Efficiency Distribution (706 Certified Units)Distribution of certified UEF ratings across 706 units in Hybrid/Electric Heat Pump, marking Rheem PROPH50 T0 RH120-M at 3.0 UEF.21130201631342031241542.52 UEF4.50 UEFMedian 3.702029 min 2.30Rheem PROPH50 T0 RH120-M: 3.00
Hybrid/Electric Heat Pump UEF Efficiency Distribution (706 Certified Units). Highlighted pin shows Rheem PROPH50 T0 RH120-M relative to the cohort median.
Efficiency comparison & rule summary

Rheem PROPH50 T0 RH120-M (3.0 UEF) ranks #666 of 706 Hybrid/Electric Heat Pump models — 28-way tie; more efficient than 1.8% of Hybrid/Electric Heat Pump models, -0.70 UEF below the 3.70 UEF median.

Federal 2029 margin for Rheem PROPH50 T0 RH120-M: +0.70 UEF (+30.4%) vs. 10 CFR 430.32(d)(2) Electric >35 to <=55 gal (2.30 UEF). At EIA August 2026 national rates (18.16 cents/kWh), 1,072 kWh/yr for Rheem PROPH50 T0 RH120-M runs ~$195/yr vs. ~$635/yr for a 0.92 UEF electric tank.

State electric sensitivity for Rheem PROPH50 T0 RH120-M: 10-year operating spend spans $1,568 in Washington (Lowest Hydro Tier) (14.63 cents/kWh) to $5,058 in Hawaii (Highest EIA State) (47.18 cents/kWh).

Peer comparison: Rheem PROPH50 T0 RH120-M (3.0 UEF) compares closely with Friedrich PROH50 T0 FD120-M (3.0 UEF, at parity) and Richmond 10E50-HP120M (3.0 UEF, at parity).

Where Does Rheem PROPH50 T0 RH120-M Rank Against Peer Hybrid/Electric Heat Pump Units?

Audited against 706 ENERGY STAR Hybrid/Electric Heat Pump listings, Rheem PROPH50 T0 RH120-M holds #666 of 706; inspect footprint, circuit load, and efficiency deltas here.

Certified model attributes compared against 706 ENERGY STAR Hybrid/Electric Heat Pump peers
Specification AttributeCertified ValueCohort Benchmark / DeltaProvenance
Manufacturer / BrandRheem236 certified listingsENERGY STAR PD 3555170
Model NumberPROPH50 T0 RH120-MDraw pattern: Medium-UsagePROPH50 T0 RH120-M
Uniform Energy Factor (UEF)3.0-0.70 UEF vs. 3.70 UEF median10 CFR 430 Test Method
First Hour Rating (FHR)55 gal-17 gal vs. 72 gal median10 CFR 430 Recovery Test
Rated Annual Electricity Use1,072 kWh/yrAt 1,072 kWh/yr medianEst. $195/yr @ $0.1816/kWh (EIA US Avg)
Thermal Recovery Efficiency367%-62.0 pts vs. 429.0% medianENERGY STAR Dataset
Physical Envelope (H x Dia)61.8" H x 22.3" DFits standard 72 in. basement/garage clearance; clears 28 in. utility doorway (22.3" D)Doorway & ceiling check
Electrical Circuit Requirements120 V / 4.5 A max120V plug-in retrofit circuit; slower heat-pump-only recoveryNEC / Branch circuit check
Heat Pump Refrigerant & GWPR-134a (GWP:1430)Check regional AIM Act phase-down transitionEPA AIM Act Compliance
Certification Date2026-10-16Certified 2026-10-16Markets: United States

How Much Electricity Does PROPH50 T0 RH120-M Use in Different States?

Estimated at $195/yr nationally (1,072 kWh/yr), 10-year utility spending for Rheem PROPH50 T0 RH120-M shifts sharply between low-rate hydro and coastal grids.

Estimated Annual Electricity Cost by State Rate (1,072 kWh/yr)Projected annual electricity spend across five benchmark EIA August 2026 residential electric tiers.United States Average$195.00/yrHawaii$506.00/yrCalifornia$319.00/yrTexas$171.00/yrWashington$157.00/yr
Projected annual electricity spend across five benchmark EIA August 2026 residential electric tiers.
Estimated electricity cost and 10-year spend across benchmark states
Jurisdiction (EIA Aug 2026)Residential RateAnnual Cost10-Yr Operating Spend10-Yr Savings vs. 0.92 UEF
United States Average 18.16 ¢/kWh ($0.1816) $195/yr $1,947 $4,402
Hawaii (Highest EIA State) 47.18 ¢/kWh ($0.4718) $506/yr $5,058 $11,436
California 29.75 ¢/kWh ($0.2975) $319/yr $3,189 $7,211
Texas 15.91 ¢/kWh ($0.1591) $171/yr $1,706 $3,857
Washington (Lowest Hydro Tier) 14.63 ¢/kWh ($0.1463) $157/yr $1,568 $3,546
Estimated electricity spend (1,072 kWh/yr)

Condensing Gas Tankless vs. Storage Tank Flow Path & Gas Supply Engineering schematic contrasting 199,000 BTU/h condensing tankless piping (3/4 in. gas supply, Category IV PVC vent, condensate drain) against a 40,000 BTU/h atmospheric tank. Condensing Gas Tankless (0.91–0.96 UEF) Secondary HX Cat IV PVC Vent Cold In Hot Out 3/4"–1" Gas 199K BTU/h Condensate Atmospheric Storage Tank (0.58–0.65 UEF) Type B Flue Anode Rod 40K BTU/h 1/2" Gas Up to 100 ft T&P 150 psi 50–85 gal FHR Reserve | 8–12 yr life
Technical comparison: condensing gas tankless units require 3/4 in.–1 in. IFGC Table 402.4 gas supply and Category IV condensate drainage, while atmospheric tanks run on 1/2 in. lines.

Does CPSC Flag Any Safety Notices on Rheem Units?

Checking 2026-11-23 SaferProducts data shows 4 notices mentioning Rheem; always cross-reference affected serial prefixes before ordering components. See Serial Number Lookup.

4 Brand Recall Notices Found in CPSC Feed — Verify Serial & Model Range
  • Recall #16177 (2016-05-26): Rheem Recalls to Repair Water Heaters Due to Fire and Burn Hazards; Sold Exclusively at Home Depot (CPSC Notice)
  • Recall #07108 (2007-02-21): Tankless Water Heaters Recalled for Repair Due to Carbon Monoxide Poisoning Hazard (CPSC Notice)
  • Recall #05274 (2005-09-16): CPSC, Robertshaw Controls Co. Announce Recall of Gas Control Valves on Water Heaters (CPSC Notice)
  • Recall #80042 (1980-12-04): LP Gas Water Heaters Repaired by White-Rodgers (CPSC Notice)

Which Competing Hybrid/Electric Heat Pump Models Compare Closest to PROPH50 T0 RH120-M?

Compare five nearby ENERGY STAR Hybrid/Electric Heat Pump options matched closely to Rheem PROPH50 T0 RH120-M's gallon capacity and 3.0 UEF efficiency.

5 closest certified peers matched by equipment class, storage volume, and efficiency rating
Brand & ModelTypeVolFHRUEF (Δ)kWh/yr
Friedrich PROH50 T0 FD120-M Hybrid/Electric Heat Pump 46 gal 55 gal 3.0 (at parity) 1,072
Richmond 10E50-HP120M Hybrid/Electric Heat Pump 46 gal 55 gal 3.0 (at parity) 1,072
Ruud PROUH50 T0 RU120-M Hybrid/Electric Heat Pump 46 gal 55 gal 3.0 (at parity) 1,072
A. O. Smith HPTV-50 2** Hybrid/Electric Heat Pump 46 gal 52 gal 3.0 (at parity) 1,550
Friedrich PROH50 T0 FD120-MSO Hybrid/Electric Heat Pump 46 gal 55 gal 3.0 (at parity) 1,072

What Are the Limitations of Rheem PROPH50 T0 RH120-M and Who Should Not Install It?

Before ordering Rheem PROPH50 T0 RH120-M (Hybrid/Electric Heat Pump, 3.0 UEF), weigh space clearances, fuel piping, noise (standard dBA), and 2029 rule readiness across three scenarios.

Key Limitations & Exclusions

  • Rheem PROPH50 T0 RH120-M needs >=450 cu ft room air volume or ducting so compressor cooling does not stall recovery.
  • Compressor runs near 49 dBA; avoid mounting Rheem PROPH50 T0 RH120-M directly beside quiet bedrooms.
  • Requires condensate drain routing and 120V electrical capacity; verify state DOE HEAR status.

Which Option Fits Your Situation?

High Electric Rate States Choosing Rheem PROPH50 T0 RH120-M Strong Fit — 3.0 UEF trims electric use ~75% vs 0.92 UEF tanks.
Open Basement or Garage (>=450 cu ft) Strong Fit — Ample ambient air sustains heat-pump-only efficiency.
Small Interior Closet (<300 cu ft) Caution — Add duct kit or compare Friedrich PROH50 T0 FD120-M footprint.

Common Homeowner Questions for Rheem PROPH50 T0 RH120-M

Direct answers to common technical, regulatory, and sizing questions sourced from primary U.S. government and OEM documentation.

Does Rheem PROPH50 T0 RH120-M pass the May 6, 2029 federal DOE efficiency rule?

Rheem PROPH50 T0 RH120-M carries a verified 3.0 UEF rating (Pass: +0.70 / +30.4%), ranking #666 of 706 across 706 ENERGY STAR Hybrid/Electric Heat Pump models under 10 CFR 430.32.

What doorway width and ceiling height does Rheem PROPH50 T0 RH120-M need?

Rheem PROPH50 T0 RH120-M stands 61.8 in. high with a 22.3 in. diameter; fits standard 72 in. basement/garage clearance; clears 28 in. utility doorway (22.3" d). Leave overhead clearance for dielectric nipples, ball shutoff valves, and top air filters.

What gas pipe size or electrical breaker does Rheem PROPH50 T0 RH120-M require?

Rheem PROPH50 T0 RH120-M uses a 120V branch circuit at 4.5A max (120V plug-in retrofit circuit; slower heat-pump-only recovery). Verify main breaker space before replacing a gas tank with an electric hybrid unit.

How much electricity or energy does Rheem PROPH50 T0 RH120-M cost per year to run?

Rated at 1,072 kWh/yr, Rheem PROPH50 T0 RH120-M costs about $195/yr ($1,950 over 10 years) at the August 2026 EIA US average of 18.16 cents/kWh (ranging from $157/yr in Washington hydro tiers up to $506/yr in Hawaii).

Who should NOT install Rheem PROPH50 T0 RH120-M, and what are its limits?

Rheem PROPH50 T0 RH120-M (3.0 UEF) is a poor fit for unvented closets under 450 cu ft because compressor intake chills enclosed rooms and runs at 49 dBA.

How many bathrooms or people can Rheem PROPH50 T0 RH120-M serve at peak demand?

Rheem PROPH50 T0 RH120-M achieves a 55 gal First Hour Rating (-17 gal vs. 72 gal median). Two back-to-back showers plus a dishwasher run typically call for 55–70 gal FHR.

Are there CPSC safety recalls or serial checks for Rheem PROPH50 T0 RH120-M?

CPSC SaferProducts records show 4 brand-level recall notices mentioning Rheem as of 2026-11-23, including #16177 (2016-05-26). Enter the rating-plate serial into TapAndPipe's Serial Lookup tool to verify production week.

What 2026 rebates apply to Rheem PROPH50 T0 RH120-M, and what peer compares closest?

Federal Section 25C expired Dec 31, 2025 (P.L. 119-21); qualifying HPWHs remain eligible for state DOE HEAR rebates up to $1,750 (<=150% AMI). Closest peer in Hybrid/Electric Heat Pump is Friedrich PROH50 T0 FD120-M (3.0 UEF).

Sources

  1. ENERGY STAR Certified Water Heaters Dataset (Socrata pbpq-swnu) — U.S. EPA & DOE ENERGY STAR, 2026 Live Certified Registry (retrieved 2026-11-23)
  2. 10 CFR 430.32 — Energy and Water Conservation Standards (Water Heaters & Plumbing Fixtures) — U.S. Department of Energy / eCFR, 2026 eCFR (incl. May 6, 2029 Rule) (retrieved 2026-11-23)
  3. CPSC SaferProducts.gov Product Recalls REST API — U.S. Consumer Product Safety Commission, 2026 Live Recalls Feed (retrieved 2026-11-23)
  4. EIA Electric Power Monthly Table 5.6.A — Average Residential Electricity Price by State — U.S. Energy Information Administration (EIA), August 2026 Monthly Release (retrieved 2026-11-23)

Related U.S. Metro Plumbing Benchmarks