ENERGY STAR water heater model · PD 3845913

Friedrich PROH65 T0 FD120-M Water Heater Specifications (3.12 UEF)

With PD 3845913 certification, Friedrich PROH65 T0 FD120-M (Hybrid/Electric Heat Pump, Electric) achieves a certified 3.12 UEF rating across its 59-gallon nominal tank, 63 gal First Hour Rating, standing #654 of 706 across 706 peers with Pass: +0.62 / +24.8% for May 6, 2029. Rated annual electricity draw of 971 kWh/yr equates to roughly $176/yr ($1,763 over 10 years) at 18.16 cents/kWh. Closest certified alternative is Rheem PROPH65 T0 RH120-M (3.12 UEF).

Uniform Energy Factor
3.12 UEF
Cohort UEF Rank
#654 of 706
First Hour Rating
63 gal
Storage Volume
59 gal
Fuel / Type
Electric / Hybrid/Electric Heat Pump
DOE 2029 Rule Status
Pass: +0.62 / +24.8%
Hybrid heat pump water heater upper shroud with brass relief valve and insulated copper risers
Hybrid heat pump water heater upper shroud with brass relief valve and insulated copper risers
Hybrid/Electric Heat Pump UEF Efficiency Distribution (706 Certified Units)Distribution of certified UEF ratings across 706 units in Hybrid/Electric Heat Pump, marking Friedrich PROH65 T0 FD120-M at 3.12 UEF.21130201631342031241542.52 UEF4.50 UEFMedian 3.702029 min 2.50Friedrich PROH65 T0 FD120-M: 3.12
Hybrid/Electric Heat Pump UEF Efficiency Distribution (706 Certified Units). Highlighted pin shows Friedrich PROH65 T0 FD120-M relative to the cohort median.
Efficiency comparison & rule summary

ENERGY STAR certification places Friedrich PROH65 T0 FD120-M at 3.12 UEF (#654 of 706; -0.58 UEF vs. 3.70 UEF median) in Hybrid/Electric Heat Pump.

May 6, 2029 readiness: Friedrich PROH65 T0 FD120-M stands +0.62 UEF (+24.8%) relative to 10 CFR 430.32(d)(2) Electric >55 to <=120 gal (2.50 UEF). At EIA August 2026 national rates (18.16 cents/kWh), 971 kWh/yr for Friedrich PROH65 T0 FD120-M runs ~$176/yr vs. ~$598/yr for a 0.92 UEF electric tank.

State electric sensitivity for Friedrich PROH65 T0 FD120-M: 10-year operating spend spans $1,421 in Washington (Lowest Hydro Tier) (14.63 cents/kWh) to $4,581 in Hawaii (Highest EIA State) (47.18 cents/kWh).

In the Hybrid/Electric Heat Pump tier, Rheem PROPH65 T0 RH120-M (3.12 UEF, at parity) and Richmond 10E65-HP120M (3.12 UEF, at parity) bracket Friedrich PROH65 T0 FD120-M.

Which Specs Set Friedrich PROH65 T0 FD120-M Apart From Cohort Averages?

Ranked #654 of 706 inside the 706-model Hybrid/Electric Heat Pump cohort, Friedrich PROH65 T0 FD120-M is evaluated row by row below against category medians.

Certified model attributes compared against 706 ENERGY STAR Hybrid/Electric Heat Pump peers
Specification AttributeCertified ValueCohort Benchmark / DeltaProvenance
Manufacturer / BrandFriedrich61 certified listingsENERGY STAR PD 3845913
Model NumberPROH65 T0 FD120-MDraw pattern: Medium-UsagePROH65 T0 FD120-M
Uniform Energy Factor (UEF)3.12-0.58 UEF vs. 3.70 UEF median10 CFR 430 Test Method
First Hour Rating (FHR)63 gal-9 gal vs. 72 gal median10 CFR 430 Recovery Test
Rated Annual Electricity Use971 kWh/yr-101 kWh/yr vs. 1,072 kWh/yr medianEst. $176/yr @ $0.1816/kWh (EIA US Avg)
Thermal Recovery Efficiency398%-31.0 pts vs. 429.0% medianENERGY STAR Dataset
Physical Envelope (H x Dia)47.8" H x 20" DFits standard 72 in. basement/garage clearance; clears 28 in. utility doorway (20" D)Doorway & ceiling check
Electrical Circuit Requirements120 V / 12 A max120V plug-in retrofit circuit; slower heat-pump-only recoveryNEC / Branch circuit check
Heat Pump Refrigerant & GWPR-134a (GWP:1430)Check regional AIM Act phase-down transitionEPA AIM Act Compliance
Certification Date2026-10-15Certified 2026-10-15Markets: United States, Canada

How Do Regional kWh Prices Impact PROH65 T0 FD120-M Over 10 Years?

Using EIA Table 5.6.A benchmarks, Friedrich PROH65 T0 FD120-M's 971 kWh/yr draw translates to roughly $176/yr on typical US residential bills.

Estimated Annual Electricity Cost by State Rate (971 kWh/yr)Projected annual electricity spend across five benchmark EIA August 2026 residential electric tiers.United States Average$176.00/yrHawaii$458.00/yrCalifornia$289.00/yrTexas$154.00/yrWashington$142.00/yr
Projected annual electricity spend across five benchmark EIA August 2026 residential electric tiers.
Estimated electricity cost and 10-year spend across benchmark states
Jurisdiction (EIA Aug 2026)Residential RateAnnual Cost10-Yr Operating Spend10-Yr Savings vs. 0.92 UEF
United States Average 18.16 ¢/kWh ($0.1816) $176/yr $1,763 $4,217
Hawaii (Highest EIA State) 47.18 ¢/kWh ($0.4718) $458/yr $4,581 $10,955
California 29.75 ¢/kWh ($0.2975) $289/yr $2,889 $6,908
Texas 15.91 ¢/kWh ($0.1591) $154/yr $1,545 $3,694
Washington (Lowest Hydro Tier) 14.63 ¢/kWh ($0.1463) $142/yr $1,421 $3,397
Estimated electricity spend (971 kWh/yr)

Condensing Gas Tankless vs. Storage Tank Flow Path & Gas Supply Engineering schematic contrasting 199,000 BTU/h condensing tankless piping (3/4 in. gas supply, Category IV PVC vent, condensate drain) against a 40,000 BTU/h atmospheric tank. Condensing Gas Tankless (0.91–0.96 UEF) Secondary HX Cat IV PVC Vent Cold In Hot Out 3/4"–1" Gas 199K BTU/h Condensate Atmospheric Storage Tank (0.58–0.65 UEF) Type B Flue Anode Rod 40K BTU/h 1/2" Gas Up to 100 ft T&P 150 psi 50–85 gal FHR Reserve | 8–12 yr life
Technical comparison: condensing gas tankless units require 3/4 in.–1 in. IFGC Table 402.4 gas supply and Category IV condensate drainage, while atmospheric tanks run on 1/2 in. lines.

What Should Friedrich Owners Check in CPSC Recall Logs?

The 2026-11-23 CPSC recall sweep recorded zero brand matches for Friedrich; run a quick serial-number check to verify age before replacing wear parts. See Serial Number Lookup.

How Do Five Nearby Hybrid/Electric Heat Pump Models Stack Up?

Five alternative Hybrid/Electric Heat Pump units with nearly identical gallon storage and UEF scores are listed below alongside exact efficiency spreads.

5 closest certified peers matched by equipment class, storage volume, and efficiency rating
Brand & ModelTypeVolFHRUEF (Δ)kWh/yr
Rheem PROPH65 T0 RH120-M Hybrid/Electric Heat Pump 59 gal 63 gal 3.12 (at parity) 971
Richmond 10E65-HP120M Hybrid/Electric Heat Pump 59 gal 63 gal 3.12 (at parity) 971
Ruud PROUH65 T0 RU120-M Hybrid/Electric Heat Pump 59 gal 63 gal 3.12 (at parity) 971
A. O. Smith HPACO-45 1**+AXST-66 1** Hybrid/Electric Heat Pump 60 gal 82 gal 3.7 (+0.58) 1,341
Rheem PROPH65 T0 RH120-MSO Hybrid/Electric Heat Pump 59 gal 63 gal 3.12 (at parity) 971

When Should Homeowners Skip Friedrich PROH65 T0 FD120-M (Hybrid/Electric Heat Pump)?

Check Friedrich PROH65 T0 FD120-M's mechanical constraints—including utility space, Electric capacity, and Pass: +0.62 / +24.8% status—against typical residential installations.

Key Limitations & Exclusions

  • Friedrich PROH65 T0 FD120-M needs >=450 cu ft room air volume or ducting so compressor cooling does not stall recovery.
  • Compressor runs near 49 dBA; avoid mounting Friedrich PROH65 T0 FD120-M directly beside quiet bedrooms.
  • Requires condensate drain routing and 120V electrical capacity; verify state DOE HEAR status.

Which Option Fits Your Situation?

High Electric Rate States Choosing Friedrich PROH65 T0 FD120-M Strong Fit — 3.12 UEF trims electric use ~75% vs 0.92 UEF tanks.
Open Basement or Garage (>=450 cu ft) Strong Fit — Ample ambient air sustains heat-pump-only efficiency.
Small Interior Closet (<300 cu ft) Caution — Add duct kit or compare Rheem PROPH65 T0 RH120-M footprint.

Frequently Asked Technical Questions: Friedrich PROH65 T0 FD120-M

Direct answers to common technical, regulatory, and sizing questions sourced from primary U.S. government and OEM documentation.

Will Friedrich PROH65 T0 FD120-M stay compliant after the May 6, 2029 DOE standard takes effect?

Tested at 3.12 UEF, Friedrich PROH65 T0 FD120-M shows Pass: +0.62 / +24.8% relative to May 6, 2029 federal DOE limits while placing #654 of 706 among 706 Hybrid/Electric Heat Pump peers like Rheem PROPH65 T0 RH120-M.

Will Friedrich PROH65 T0 FD120-M fit through a standard utility door and 72-inch basement ceiling?

Measuring 47.8 in. tall by 20 in. diameter, Friedrich PROH65 T0 FD120-M notes: fits standard 72 in. basement/garage clearance; clears 28 in. utility doorway (20" d). Reserve space above the jacket for T&P piping and anode removal.

Do existing utility hookups support Friedrich PROH65 T0 FD120-M during replacement?

Electrical specs for Friedrich PROH65 T0 FD120-M call for 120V at 12A max (120V plug-in retrofit circuit; slower heat-pump-only recovery). Have a licensed electrician inspect panel load and wire gauge.

What is the estimated 10-year operating spend for Friedrich PROH65 T0 FD120-M?

At 18.16 cents/kWh national residential pricing, Friedrich PROH65 T0 FD120-M's 971 kWh/yr draw equals roughly $176 annually or $1,760 across a 10-year horizon (ranging from $142/yr in Washington hydro tiers up to $458/yr in Hawaii).

When is Friedrich PROH65 T0 FD120-M a poor fit for a residential replacement?

Avoid placing Friedrich PROH65 T0 FD120-M directly next to bedrooms or inside tight <300 cu ft closets without ducting, due to 49 dBA sound and cool exhaust airflow.

What First Hour Rating or flow capacity does Friedrich PROH65 T0 FD120-M deliver?

With 63 gal FHR (-9 gal vs. 72 gal median), Friedrich PROH65 T0 FD120-M fits 1–3 person or moderate-draw homes cleanly.

How do you verify manufacturing age and recall status on Friedrich PROH65 T0 FD120-M?

Our 2026-11-23 CPSC SaferProducts feed lists zero recalls for Friedrich; verify exact manufacturing week for Friedrich PROH65 T0 FD120-M using the Serial Number Lookup tool.

Does Friedrich PROH65 T0 FD120-M qualify for DOE HEAR incentives after 25C expired?

After 25C sunset on Dec 31, 2025 under OBBBA, check state DOE HEAR (up to $1,750 income-qualified) and utility rebates for Friedrich PROH65 T0 FD120-M. Closest peer in Hybrid/Electric Heat Pump is Rheem PROPH65 T0 RH120-M (3.12 UEF).

Sources

  1. ENERGY STAR Certified Water Heaters Dataset (Socrata pbpq-swnu) — U.S. EPA & DOE ENERGY STAR, 2026 Live Certified Registry (retrieved 2026-11-23)
  2. 10 CFR 430.32 — Energy and Water Conservation Standards (Water Heaters & Plumbing Fixtures) — U.S. Department of Energy / eCFR, 2026 eCFR (incl. May 6, 2029 Rule) (retrieved 2026-11-23)
  3. CPSC SaferProducts.gov Product Recalls REST API — U.S. Consumer Product Safety Commission, 2026 Live Recalls Feed (retrieved 2026-11-23)
  4. EIA Electric Power Monthly Table 5.6.A — Average Residential Electricity Price by State — U.S. Energy Information Administration (EIA), August 2026 Monthly Release (retrieved 2026-11-23)