Skip to main content
ENERGY STAR water heater model · PD 3555349

Richmond 10E65-HP120M Water Heater Specifications (3.12 UEF)

In the 706-unit Hybrid/Electric Heat Pump class, Richmond 10E65-HP120M (Electric) achieves a certified 3.12 UEF rating across its 59-gallon nominal tank, 63 gal First Hour Rating (rank #654 of 706, PD 3555349) and verifies as Pass: +0.62 / +24.8% for 2029 DOE floors. Rated annual electricity draw of 971 kWh/yr equates to roughly $176/yr ($1,763 over 10 years) at 18.16 cents/kWh. Closest certified alternative is Friedrich PROH65 T0 FD120-M (3.12 UEF).

Uniform Energy Factor
3.12 UEF
Cohort UEF Rank
#654 of 706
First Hour Rating
63 gal
Storage Volume
59 gal
Fuel / Type
Electric / Hybrid/Electric Heat Pump
DOE 2029 Rule Status
Pass: +0.62 / +24.8%
Hybrid heat pump water heater upper shroud with brass relief valve and insulated copper risers
Hybrid heat pump water heater upper shroud with brass relief valve and insulated copper risers
Hybrid/Electric Heat Pump UEF Efficiency Distribution (706 Certified Units)Distribution of certified UEF ratings across 706 units in Hybrid/Electric Heat Pump, marking Richmond 10E65-HP120M at 3.12 UEF.21130201631342031241542.52 UEF4.50 UEFMedian 3.702029 min 2.50Richmond 10E65-HP120M: 3.12
Hybrid/Electric Heat Pump UEF Efficiency Distribution (706 Certified Units). Highlighted pin shows Richmond 10E65-HP120M relative to the cohort median.
Efficiency comparison & rule summary

Richmond 10E65-HP120M records 3.12 UEF efficiency, putting it #654 of 706 among 706 Hybrid/Electric Heat Pump peers.

10 CFR 430.32(d)(2) compliance: Richmond 10E65-HP120M exceeds 10 CFR 430.32(d)(2) Electric >55 to <=120 gal (2.50 UEF) by +0.62 UEF (+24.8%). At EIA August 2026 national rates (18.16 cents/kWh), 971 kWh/yr for Richmond 10E65-HP120M runs ~$176/yr vs. ~$598/yr for a 0.92 UEF electric tank.

State electric sensitivity for Richmond 10E65-HP120M: 10-year operating spend spans $1,421 in Washington (Lowest Hydro Tier) (14.63 cents/kWh) to $4,581 in Hawaii (Highest EIA State) (47.18 cents/kWh).

Competing options beside Richmond 10E65-HP120M (3.12 UEF) are Friedrich PROH65 T0 FD120-M (3.12 UEF, at parity) and Rheem PROPH65 T0 RH120-M (3.12 UEF, at parity).

How Do Richmond 10E65-HP120M Specs Compare to Hybrid/Electric Heat Pump Medians?

Richmond 10E65-HP120M places #654 of 706 across 706 certified Hybrid/Electric Heat Pump configurations, with physical dimensions, draw profile, and thermal metrics benchmarked below.

Certified model attributes compared against 706 ENERGY STAR Hybrid/Electric Heat Pump peers
Specification AttributeCertified ValueCohort Benchmark / DeltaProvenance
Manufacturer / BrandRichmond80 certified listingsENERGY STAR PD 3555349
Model Number10E65-HP120MDraw pattern: Medium-Usage10E65-HP120M
Uniform Energy Factor (UEF)3.12-0.58 UEF vs. 3.70 UEF median10 CFR 430 Test Method
First Hour Rating (FHR)63 gal-9 gal vs. 72 gal median10 CFR 430 Recovery Test
Rated Annual Electricity Use971 kWh/yr-101 kWh/yr vs. 1,072 kWh/yr medianEst. $176/yr @ $0.1816/kWh (EIA US Avg)
Thermal Recovery Efficiency398%-31.0 pts vs. 429.0% medianENERGY STAR Dataset
Physical Envelope (H x Dia)64.2" H x 24.3" DVerify 72 in. vertical headroom; clears 28 in. utility doorway (24.3" D)Doorway & ceiling check
Electrical Circuit Requirements120 V / 12 A max120V plug-in retrofit circuit; slower heat-pump-only recoveryNEC / Branch circuit check
Heat Pump Refrigerant & GWPR-134a (GWP:1430)Check regional AIM Act phase-down transitionEPA AIM Act Compliance
Certification Date2026-10-15Certified 2026-10-15Markets: United States, Canada

What Does 10E65-HP120M Cost to Operate Across State Electricity Rates?

At 971 kWh/yr, Richmond 10E65-HP120M runs roughly $176/yr on the EIA national average tier under August 2026 Table 5.6.A rates.

Estimated Annual Electricity Cost by State Rate (971 kWh/yr)Projected annual electricity spend across five benchmark EIA August 2026 residential electric tiers.United States Average$176.00/yrHawaii$458.00/yrCalifornia$289.00/yrTexas$154.00/yrWashington$142.00/yr
Projected annual electricity spend across five benchmark EIA August 2026 residential electric tiers.
Estimated electricity cost and 10-year spend across benchmark states
Jurisdiction (EIA Aug 2026)Residential RateAnnual Cost10-Yr Operating Spend10-Yr Savings vs. 0.92 UEF
United States Average 18.16 ¢/kWh ($0.1816) $176/yr $1,763 $4,217
Hawaii (Highest EIA State) 47.18 ¢/kWh ($0.4718) $458/yr $4,581 $10,955
California 29.75 ¢/kWh ($0.2975) $289/yr $2,889 $6,908
Texas 15.91 ¢/kWh ($0.1591) $154/yr $1,545 $3,694
Washington (Lowest Hydro Tier) 14.63 ¢/kWh ($0.1463) $142/yr $1,421 $3,397
Estimated electricity spend (971 kWh/yr)

Condensing Gas Tankless vs. Storage Tank Flow Path & Gas Supply Engineering schematic contrasting 199,000 BTU/h condensing tankless piping (3/4 in. gas supply, Category IV PVC vent, condensate drain) against a 40,000 BTU/h atmospheric tank. Condensing Gas Tankless (0.91–0.96 UEF) Secondary HX Cat IV PVC Vent Cold In Hot Out 3/4"–1" Gas 199K BTU/h Condensate Atmospheric Storage Tank (0.58–0.65 UEF) Type B Flue Anode Rod 40K BTU/h 1/2" Gas Up to 100 ft T&P 150 psi 50–85 gal FHR Reserve | 8–12 yr life
Technical comparison: condensing gas tankless units require 3/4 in.–1 in. IFGC Table 402.4 gas supply and Category IV condensate drainage, while atmospheric tanks run on 1/2 in. lines.

Are There Active CPSC Safety Recalls for Richmond Water Heaters?

Zero active CPSC recalls matched Richmond in our 2026-11-23 SaferProducts sweep; verify your individual tank date code via our lookup tool. See Serial Number Lookup.

Which Certified Water Heaters Match 10E65-HP120M Most Closely?

These 5 competing Hybrid/Electric Heat Pump units sit nearest to Richmond 10E65-HP120M by storage capacity and 3.12 UEF rating.

5 closest certified peers matched by equipment class, storage volume, and efficiency rating
Brand & ModelTypeVolFHRUEF (Δ)kWh/yr
Friedrich PROH65 T0 FD120-M Hybrid/Electric Heat Pump 59 gal 63 gal 3.12 (at parity) 971
Rheem PROPH65 T0 RH120-M Hybrid/Electric Heat Pump 59 gal 63 gal 3.12 (at parity) 971
Ruud PROUH65 T0 RU120-M Hybrid/Electric Heat Pump 59 gal 63 gal 3.12 (at parity) 971
A. O. Smith HPACO-45 1**+AXST-66 1** Hybrid/Electric Heat Pump 60 gal 82 gal 3.7 (+0.58) 1,341
Friedrich PROH65 T0 FD120-MSO Hybrid/Electric Heat Pump 59 gal 63 gal 3.12 (at parity) 971

Which Home Setups Are NOT a Fit for Richmond 10E65-HP120M?

Comparing Richmond 10E65-HP120M against Friedrich PROH65 T0 FD120-M requires checking closet airflow, IFGC gas or 240V electrical sizing, and May 6, 2029 compliance.

Key Limitations & Exclusions

  • Richmond 10E65-HP120M needs >=450 cu ft room air volume or ducting so compressor cooling does not stall recovery.
  • Compressor runs near 49 dBA; avoid mounting Richmond 10E65-HP120M directly beside quiet bedrooms.
  • Requires condensate drain routing and 120V electrical capacity; verify state DOE HEAR status.

Which Option Fits Your Situation?

High Electric Rate States Choosing Richmond 10E65-HP120M Strong Fit — 3.12 UEF trims electric use ~75% vs 0.92 UEF tanks.
Open Basement or Garage (>=450 cu ft) Strong Fit — Ample ambient air sustains heat-pump-only efficiency.
Small Interior Closet (<300 cu ft) Caution — Add duct kit or compare Friedrich PROH65 T0 FD120-M footprint.

What Are the Key Questions About Richmond 10E65-HP120M?

Direct answers to common technical, regulatory, and sizing questions sourced from primary U.S. government and OEM documentation.

How does Richmond 10E65-HP120M score under 10 CFR 430.32 May 2029 water heater minimums?

Federal 10 CFR 430.32 rules set the May 6, 2029 manufacturing baseline; Richmond 10E65-HP120M logs 3.12 UEF (Pass: +0.62 / +24.8%) within the 706-unit Hybrid/Electric Heat Pump group.

What physical clearance dimensions apply when installing Richmond 10E65-HP120M?

With a 64.2 in. height and 24.3 in. diameter, Richmond 10E65-HP120M fits spaces matching: verify 72 in. vertical headroom; clears 28 in. utility doorway (24.3" d), plus 6–12 in. above for plumbing shutoffs.

What 240V circuit or IFGC fuel line capacity fits Richmond 10E65-HP120M?

Powered via 120V at 12A max, Richmond 10E65-HP120M requires: 120V plug-in retrofit circuit; slower heat-pump-only recovery. Confirm double-pole breaker sizing and condensate pump outlet proximity.

How do state electricity prices change annual costs for Richmond 10E65-HP120M?

Annual electric spend for Richmond 10E65-HP120M (971 kWh/yr) averages $176/yr nationwide (ranging from $142/yr in Washington hydro tiers up to $458/yr in Hawaii), calculated directly from August 2026 EIA Table 5.6.A tariffs.

What homeowner setups should avoid choosing Richmond 10E65-HP120M?

Homes lacking a condensate drain or 120V branch circuit—or unconditioned sub-zero spaces—should verify hybrid backup mode limits on Richmond 10E65-HP120M.

Is Richmond 10E65-HP120M sized adequately for a 2-to-4-person household?

ENERGY STAR certifies Richmond 10E65-HP120M at 63 gal First Hour Rating (-9 gal vs. 72 gal median); match that hourly reserve against simultaneous 2.0 GPM showerheads.

Does Richmond have active CPSC SaferProducts notices affecting 10E65-HP120M?

Zero CPSC recall alerts matched Richmond (2026-11-23 check). Keep your Richmond 10E65-HP120M serial code handy to track standard 6-to-12-year OEM warranty coverage.

Which competing water heater matches Richmond 10E65-HP120M (3.12 UEF) most closely?

State-run DOE HEAR programs (<=150% AMI, up to $1,750 for HPWH) and electric utilities lead 2026 incentives for Richmond 10E65-HP120M. Closest peer in Hybrid/Electric Heat Pump is Friedrich PROH65 T0 FD120-M (3.12 UEF).

Sources

  1. ENERGY STAR Certified Water Heaters Dataset (Socrata pbpq-swnu) — U.S. EPA & DOE ENERGY STAR, 2026 Live Certified Registry (retrieved 2026-11-23)
  2. 10 CFR 430.32 — Energy and Water Conservation Standards (Water Heaters & Plumbing Fixtures) — U.S. Department of Energy / eCFR, 2026 eCFR (incl. May 6, 2029 Rule) (retrieved 2026-11-23)
  3. CPSC SaferProducts.gov Product Recalls REST API — U.S. Consumer Product Safety Commission, 2026 Live Recalls Feed (retrieved 2026-11-23)
  4. EIA Electric Power Monthly Table 5.6.A — Average Residential Electricity Price by State — U.S. Energy Information Administration (EIA), August 2026 Monthly Release (retrieved 2026-11-23)

Related U.S. Metro Plumbing Benchmarks