Hubbell ME65HPT Water Heater Specifications (3.34 UEF)
The Hubbell ME65HPT (Hybrid/Electric Heat Pump, Electric) achieves a certified 3.34 UEF rating across its 57-gallon nominal tank, 70 gal First Hour Rating, ranking #640 of 706 among 706 ENERGY STAR Hybrid/Electric Heat Pump models (PD 2853430). Under the May 6, 2029 DOE 10 CFR 430.32(d)(2) standard, compliance status is Pass: +0.84 / +33.6%. Rated annual electricity draw of 974 kWh/yr equates to roughly $177/yr ($1,769 over 10 years) at 18.16 cents/kWh. Closest certified alternative is Noritz NHP65 (3.34 UEF).
- Uniform Energy Factor
- 3.34 UEF
- Cohort UEF Rank
- #640 of 706
- First Hour Rating
- 70 gal
- Storage Volume
- 57 gal
- Fuel / Type
- Electric / Hybrid/Electric Heat Pump
- DOE 2029 Rule Status
- Pass: +0.84 / +33.6%

Hubbell ME65HPT (3.34 UEF) ranks #640 of 706 Hybrid/Electric Heat Pump models — 4-way tie; more efficient than 8.9% of Hybrid/Electric Heat Pump models, -0.36 UEF below the 3.70 UEF median.
Federal 2029 margin for Hubbell ME65HPT: +0.84 UEF (+33.6%) vs. 10 CFR 430.32(d)(2) Electric >55 to <=120 gal (2.50 UEF). At EIA August 2026 national rates (18.16 cents/kWh), 974 kWh/yr for Hubbell ME65HPT runs ~$177/yr vs. ~$642/yr for a 0.92 UEF electric tank.
State electric sensitivity for Hubbell ME65HPT: 10-year operating spend spans $1,425 in Washington (Lowest Hydro Tier) (14.63 cents/kWh) to $4,595 in Hawaii (Highest EIA State) (47.18 cents/kWh).
Peer comparison: Hubbell ME65HPT (3.34 UEF) compares closely with Noritz NHP65 (3.34 UEF, at parity) and VAUGHN THERMAL ME65HPT (3.34 UEF, at parity).
Where Does Hubbell ME65HPT Rank Against Peer Hybrid/Electric Heat Pump Units?
Audited against 706 ENERGY STAR Hybrid/Electric Heat Pump listings, Hubbell ME65HPT holds #640 of 706; inspect footprint, circuit load, and efficiency deltas here.
| Specification Attribute | Certified Value | Cohort Benchmark / Delta | Provenance |
|---|---|---|---|
| Manufacturer / Brand | Hubbell | 4 certified listings | ENERGY STAR PD 2853430 |
| Model Number | ME65HPT | Draw pattern: Medium-Usage | ME65HPT |
| Uniform Energy Factor (UEF) | 3.34 | -0.36 UEF vs. 3.70 UEF median | 10 CFR 430 Test Method |
| First Hour Rating (FHR) | 70 gal | -2 gal vs. 72 gal median | 10 CFR 430 Recovery Test |
| Rated Annual Electricity Use | 974 kWh/yr | -98 kWh/yr vs. 1,072 kWh/yr median | Est. $177/yr @ $0.1816/kWh (EIA US Avg) |
| Thermal Recovery Efficiency | 368% | -61.0 pts vs. 429.0% median | ENERGY STAR Dataset |
| Physical Envelope (H x Dia) | 63.8" H x 28" D | Fits standard 72 in. basement/garage clearance; tight at 28 in. door (28" D) | Doorway & ceiling check |
| Electrical Circuit Requirements | 240 V / 23 A max | Requires 240V dedicated branch circuit; check panel capacity | NEC / Branch circuit check |
| Heat Pump Refrigerant & GWP | R-134a (GWP:1430) | Check regional AIM Act phase-down transition | EPA AIM Act Compliance |
| Sound Pressure Level | 54 dBA | +5 dBA vs. 49 dBA median | Indoor placement check |
| Certification Date | 2023-12-13 | Certified 2023-12-13 | Markets: United States, Canada |
How Much Electricity Does ME65HPT Use in Different States?
Estimated at $177/yr nationally (974 kWh/yr), 10-year utility spending for Hubbell ME65HPT shifts sharply between low-rate hydro and coastal grids.
| Jurisdiction (EIA Aug 2026) | Residential Rate | Annual Cost | 10-Yr Operating Spend | 10-Yr Savings vs. 0.92 UEF |
|---|---|---|---|---|
| United States Average | 18.16 ¢/kWh ($0.1816) | $177/yr | $1,769 | $4,653 |
| Hawaii (Highest EIA State) | 47.18 ¢/kWh ($0.4718) | $460/yr | $4,595 | $12,088 |
| California | 29.75 ¢/kWh ($0.2975) | $290/yr | $2,898 | $7,622 |
| Texas | 15.91 ¢/kWh ($0.1591) | $155/yr | $1,550 | $4,076 |
| Washington (Lowest Hydro Tier) | 14.63 ¢/kWh ($0.1463) | $142/yr | $1,425 | $3,748 |
Does CPSC Flag Any Safety Notices on Hubbell Units?
No open CPSC recall alerts appeared for Hubbell as of 2026-11-23; you can still decode exact manufacture month and warranty window below. See Serial Number Lookup.
Which Competing Hybrid/Electric Heat Pump Models Compare Closest to ME65HPT?
Compare five nearby ENERGY STAR Hybrid/Electric Heat Pump options matched closely to Hubbell ME65HPT's gallon capacity and 3.34 UEF efficiency.
| Brand & Model | Type | Vol | FHR | UEF (Δ) | kWh/yr |
|---|---|---|---|---|---|
| Noritz NHP65 | Hybrid/Electric Heat Pump | 57 gal | 70 gal | 3.34 (at parity) | 974 |
| VAUGHN THERMAL ME65HPT | Hybrid/Electric Heat Pump | 57 gal | 70 gal | 3.34 (at parity) | 974 |
| Friedrich PROH65 T2 FD310BM | Hybrid/Electric Heat Pump | 59 gal | 75 gal | 3.5 (+0.16) | 900 |
| Rheem CPRO H65 T2 RH310BM | Hybrid/Electric Heat Pump | 59 gal | 75 gal | 3.5 (+0.16) | 900 |
| VAUGHN THERMAL ME65HPT-CN | Hybrid/Electric Heat Pump | 57 gal | 70 gal | 3.34 (at parity) | 974 |
What Installation Caveats Apply Before Buying Hubbell ME65HPT?
Even high-UEF units like Hubbell ME65HPT (3.34 UEF) carry physical space, condensate, and fuel-line prerequisites noted below.
Key Limitations & Exclusions
- Hubbell ME65HPT needs >=450 cu ft room air volume or ducting so compressor cooling does not stall recovery.
- Compressor runs near 54 dBA; avoid mounting Hubbell ME65HPT directly beside quiet bedrooms.
- Requires condensate drain routing and 240V electrical capacity; verify state DOE HEAR status.
Which Option Fits Your Situation?
Common Homeowner Questions for Hubbell ME65HPT
Direct answers to common technical, regulatory, and sizing questions sourced from primary U.S. government and OEM documentation.
Is Hubbell ME65HPT eligible for continued manufacture past May 6, 2029?
At 3.34 UEF, Hubbell ME65HPT achieves Pass: +0.84 / +33.6% for the 2029 DOE standard and stands #640 of 706 against Noritz NHP65 and VAUGHN THERMAL ME65HPT.
How tall and wide is Hubbell ME65HPT, and what service clearance is needed?
Physical dimensions for Hubbell ME65HPT are 63.8 in. height and 28 in. diameter (fits standard 72 in. basement/garage clearance; tight at 28 in. door (28" d)); verify stair turns and drain pan width before delivery.
Will Hubbell ME65HPT require upgrading household electrical panels or gas piping?
Hubbell ME65HPT draws 240V at 23A max (Requires 240V dedicated branch circuit; check panel capacity); check whether existing 10/2 AWG 30A copper wiring aligns with nameplate amps.
Is Hubbell ME65HPT economical to operate at 18.16 cents/kWh US electric rates?
Expect roughly $177/yr ($1,770 over 10 years) to power Hubbell ME65HPT at 974 kWh/yr under the 18.16 cents/kWh US average (ranging from $142/yr in Washington hydro tiers up to $460/yr in Hawaii).
Which installation bottlenecks limit Hubbell ME65HPT?
If ambient room air stays below 40 °F year-round or closet volume falls under 450 cu ft, Hubbell ME65HPT drops into resistance mode more often.
How does Hubbell ME65HPT handle simultaneous showers and laundry?
Delivering 70 gal in the first hour (-2 gal vs. 72 gal median), Hubbell ME65HPT combines 57 gal tank storage with rapid burner/element recovery.
How long is the warranty on Hubbell ME65HPT and how do you decode its serial?
CPSC records show 0 active plumbing recalls for Hubbell as of 2026-11-23. Confirm install proof and serial manufacture year on Hubbell ME65HPT before calling service.
How do 2026 post-OBBBA rebates affect buying Hubbell ME65HPT?
Check state energy office HEAR portals and utility rebates in 2026 since federal 25C ended Dec 31, 2025. Closest peer in Hybrid/Electric Heat Pump is Noritz NHP65 (3.34 UEF).
Sources
- ENERGY STAR Certified Water Heaters Dataset (Socrata pbpq-swnu) — U.S. EPA & DOE ENERGY STAR, 2026 Live Certified Registry (retrieved 2026-11-23)
- 10 CFR 430.32 — Energy and Water Conservation Standards (Water Heaters & Plumbing Fixtures) — U.S. Department of Energy / eCFR, 2026 eCFR (incl. May 6, 2029 Rule) (retrieved 2026-11-23)
- CPSC SaferProducts.gov Product Recalls REST API — U.S. Consumer Product Safety Commission, 2026 Live Recalls Feed (retrieved 2026-11-23)
- EIA Electric Power Monthly Table 5.6.A — Average Residential Electricity Price by State — U.S. Energy Information Administration (EIA), August 2026 Monthly Release (retrieved 2026-11-23)