Skip to main content
ENERGY STAR water heater model · PD 2408594

Rheem CPRO H65 T2 RH310BM Water Heater Specifications (3.5 UEF)

In the 706-unit Hybrid/Electric Heat Pump class, Rheem CPRO H65 T2 RH310BM (Electric) achieves a certified 3.5 UEF rating across its 59-gallon nominal tank, 75 gal First Hour Rating (rank #481 of 706, PD 2408594) and verifies as Pass: +1.00 / +40.0% for 2029 DOE floors. Rated annual electricity draw of 900 kWh/yr equates to roughly $163/yr ($1,634 over 10 years) at 18.16 cents/kWh. Closest certified alternative is Friedrich PROH65 T2 FD310BM (3.5 UEF).

Uniform Energy Factor
3.5 UEF
Cohort UEF Rank
#481 of 706
First Hour Rating
75 gal
Storage Volume
59 gal
Fuel / Type
Electric / Hybrid/Electric Heat Pump
DOE 2029 Rule Status
Pass: +1.00 / +40.0%
Hybrid heat pump water heater upper shroud with brass relief valve and insulated copper risers
Hybrid heat pump water heater upper shroud with brass relief valve and insulated copper risers
Hybrid/Electric Heat Pump UEF Efficiency Distribution (706 Certified Units)Distribution of certified UEF ratings across 706 units in Hybrid/Electric Heat Pump, marking Rheem CPRO H65 T2 RH310BM at 3.5 UEF.21130201631342031241542.52 UEF4.50 UEFMedian 3.702029 min 2.50Rheem CPRO H65 T2 RH310BM: 3.50
Hybrid/Electric Heat Pump UEF Efficiency Distribution (706 Certified Units). Highlighted pin shows Rheem CPRO H65 T2 RH310BM relative to the cohort median.
Efficiency comparison & rule summary

Rheem CPRO H65 T2 RH310BM records 3.5 UEF efficiency, putting it #481 of 706 among 706 Hybrid/Electric Heat Pump peers.

10 CFR 430.32(d)(2) compliance: Rheem CPRO H65 T2 RH310BM exceeds 10 CFR 430.32(d)(2) Electric >55 to <=120 gal (2.50 UEF) by +1.00 UEF (+40.0%). At EIA August 2026 national rates (18.16 cents/kWh), 900 kWh/yr for Rheem CPRO H65 T2 RH310BM runs ~$163/yr vs. ~$622/yr for a 0.92 UEF electric tank.

State electric sensitivity for Rheem CPRO H65 T2 RH310BM: 10-year operating spend spans $1,317 in Washington (Lowest Hydro Tier) (14.63 cents/kWh) to $4,246 in Hawaii (Highest EIA State) (47.18 cents/kWh).

Competing options beside Rheem CPRO H65 T2 RH310BM (3.5 UEF) are Friedrich PROH65 T2 FD310BM (3.5 UEF, at parity) and Ruud PRO H65 T2 RU310BM (3.5 UEF, at parity).

How Complete Are the Certified Metrics for Rheem CPRO H65 T2 RH310BM?

Standing at #481 of 706 among 706 certified Hybrid/Electric Heat Pump heaters, Rheem CPRO H65 T2 RH310BM brings measurable deltas in recovery, footprint, and energy efficiency.

Certified model attributes compared against 706 ENERGY STAR Hybrid/Electric Heat Pump peers
Specification AttributeCertified ValueCohort Benchmark / DeltaProvenance
Manufacturer / BrandRheem236 certified listingsENERGY STAR PD 2408594
Model NumberCPRO H65 T2 RH310BMDraw pattern: High-UsageCPRO H65 T2 RH310BM
Uniform Energy Factor (UEF)3.5-0.20 UEF vs. 3.70 UEF median10 CFR 430 Test Method
First Hour Rating (FHR)75 gal+3 gal vs. 72 gal median10 CFR 430 Recovery Test
Rated Annual Electricity Use900 kWh/yr-172 kWh/yr vs. 1,072 kWh/yr medianEst. $163/yr @ $0.1816/kWh (EIA US Avg)
Thermal Recovery Efficiency409%-20.0 pts vs. 429.0% medianENERGY STAR Dataset
Physical Envelope (H x Dia)64.2" H x 24.3" DVerify 72 in. vertical headroom; clears 28 in. utility doorway (24.3" D)Doorway & ceiling check
Electrical Circuit Requirements240 V / 21 A maxRequires 240V dedicated branch circuit; check panel capacityNEC / Branch circuit check
Heat Pump Refrigerant & GWPR-134a (GWP:1430)Check regional AIM Act phase-down transitionEPA AIM Act Compliance
Certification Date2026-10-15Certified 2026-10-15Markets: Canada

What Is the Projected Utility Bill for CPRO H65 T2 RH310BM by State?

At 900 kWh/yr, Rheem CPRO H65 T2 RH310BM averages about $163/yr across US households—see 10-year payback spreads versus 0.92 UEF resistance tanks.

Estimated Annual Electricity Cost by State Rate (900 kWh/yr)Projected annual electricity spend across five benchmark EIA August 2026 residential electric tiers.United States Average$163.00/yrHawaii$425.00/yrCalifornia$268.00/yrTexas$143.00/yrWashington$132.00/yr
Projected annual electricity spend across five benchmark EIA August 2026 residential electric tiers.
Estimated electricity cost and 10-year spend across benchmark states
Jurisdiction (EIA Aug 2026)Residential RateAnnual Cost10-Yr Operating Spend10-Yr Savings vs. 0.92 UEF
United States Average 18.16 ¢/kWh ($0.1816) $163/yr $1,634 $4,584
Hawaii (Highest EIA State) 47.18 ¢/kWh ($0.4718) $425/yr $4,246 $11,908
California 29.75 ¢/kWh ($0.2975) $268/yr $2,678 $7,509
Texas 15.91 ¢/kWh ($0.1591) $143/yr $1,432 $4,016
Washington (Lowest Hydro Tier) 14.63 ¢/kWh ($0.1463) $132/yr $1,317 $3,693
Estimated electricity spend (900 kWh/yr)

Condensing Gas Tankless vs. Storage Tank Flow Path & Gas Supply Engineering schematic contrasting 199,000 BTU/h condensing tankless piping (3/4 in. gas supply, Category IV PVC vent, condensate drain) against a 40,000 BTU/h atmospheric tank. Condensing Gas Tankless (0.91–0.96 UEF) Secondary HX Cat IV PVC Vent Cold In Hot Out 3/4"–1" Gas 199K BTU/h Condensate Atmospheric Storage Tank (0.58–0.65 UEF) Type B Flue Anode Rod 40K BTU/h 1/2" Gas Up to 100 ft T&P 150 psi 50–85 gal FHR Reserve | 8–12 yr life
Technical comparison: condensing gas tankless units require 3/4 in.–1 in. IFGC Table 402.4 gas supply and Category IV condensate drainage, while atmospheric tanks run on 1/2 in. lines.

Are Rheem Models Affected by Current CPSC Notices?

Review 4 brand-matched CPSC entries pulled 2026-11-23 for Rheem and confirm your serial tag before scheduling contractor service. See Serial Number Lookup.

4 Brand Recall Notices Found in CPSC Feed — Verify Serial & Model Range
  • Recall #16177 (2016-05-26): Rheem Recalls to Repair Water Heaters Due to Fire and Burn Hazards; Sold Exclusively at Home Depot (CPSC Notice)
  • Recall #07108 (2007-02-21): Tankless Water Heaters Recalled for Repair Due to Carbon Monoxide Poisoning Hazard (CPSC Notice)
  • Recall #05274 (2005-09-16): CPSC, Robertshaw Controls Co. Announce Recall of Gas Control Valves on Water Heaters (CPSC Notice)
  • Recall #80042 (1980-12-04): LP Gas Water Heaters Repaired by White-Rodgers (CPSC Notice)

Which 5 Models Offer Similar Output to CPRO H65 T2 RH310BM?

Ordered by minimal capacity and UEF spread relative to Rheem CPRO H65 T2 RH310BM, these five certified peers give direct replacement benchmarks.

5 closest certified peers matched by equipment class, storage volume, and efficiency rating
Brand & ModelTypeVolFHRUEF (Δ)kWh/yr
Friedrich PROH65 T2 FD310BM Hybrid/Electric Heat Pump 59 gal 75 gal 3.5 (at parity) 900
Ruud PRO H65 T2 RU310BM Hybrid/Electric Heat Pump 59 gal 75 gal 3.5 (at parity) 900
Richmond 10CE65-HP5U15 Hybrid/Electric Heat Pump 59 gal 54 gal 3.55 (+0.05) 887
A. O. Smith HPACO-45 1**+AXST-66 1** Hybrid/Electric Heat Pump 60 gal 82 gal 3.7 (+0.20) 1,341
Friedrich PROH65 T2 FD310UM Hybrid/Electric Heat Pump 59 gal 75 gal 3.5 (at parity) 900

When Should Homeowners Skip Rheem CPRO H65 T2 RH310BM (Hybrid/Electric Heat Pump)?

Check Rheem CPRO H65 T2 RH310BM's mechanical constraints—including utility space, Electric capacity, and Pass: +1.00 / +40.0% status—against typical residential installations.

Key Limitations & Exclusions

  • Rheem CPRO H65 T2 RH310BM needs >=450 cu ft room air volume or ducting so compressor cooling does not stall recovery.
  • Compressor runs near 49 dBA; avoid mounting Rheem CPRO H65 T2 RH310BM directly beside quiet bedrooms.
  • Requires condensate drain routing and 240V electrical capacity; verify state DOE HEAR status.

Which Option Fits Your Situation?

High Electric Rate States Choosing Rheem CPRO H65 T2 RH310BM Strong Fit — 3.5 UEF trims electric use ~75% vs 0.92 UEF tanks.
Open Basement or Garage (>=450 cu ft) Strong Fit — Ample ambient air sustains heat-pump-only efficiency.
Small Interior Closet (<300 cu ft) Caution — Add duct kit or compare Friedrich PROH65 T2 FD310BM footprint.

Practical Specs & Code Questions for Rheem CPRO H65 T2 RH310BM

Direct answers to common technical, regulatory, and sizing questions sourced from primary U.S. government and OEM documentation.

Will Rheem CPRO H65 T2 RH310BM stay compliant after the May 6, 2029 DOE standard takes effect?

Tested at 3.5 UEF, Rheem CPRO H65 T2 RH310BM shows Pass: +1.00 / +40.0% relative to May 6, 2029 federal DOE limits while placing #481 of 706 among 706 Hybrid/Electric Heat Pump peers like Friedrich PROH65 T2 FD310BM.

Will Rheem CPRO H65 T2 RH310BM fit through a standard utility door and 72-inch basement ceiling?

Measuring 64.2 in. tall by 24.3 in. diameter, Rheem CPRO H65 T2 RH310BM notes: verify 72 in. vertical headroom; clears 28 in. utility doorway (24.3" d). Reserve space above the jacket for T&P piping and anode removal.

Do existing utility hookups support Rheem CPRO H65 T2 RH310BM during replacement?

Electrical specs for Rheem CPRO H65 T2 RH310BM call for 240V at 21A max (Requires 240V dedicated branch circuit; check panel capacity). Have a licensed electrician inspect panel load and wire gauge.

What is the estimated 10-year operating spend for Rheem CPRO H65 T2 RH310BM?

At 18.16 cents/kWh national residential pricing, Rheem CPRO H65 T2 RH310BM's 900 kWh/yr draw equals roughly $163 annually or $1,630 across a 10-year horizon (ranging from $132/yr in Washington hydro tiers up to $425/yr in Hawaii).

When is Rheem CPRO H65 T2 RH310BM a poor fit for a residential replacement?

Avoid placing Rheem CPRO H65 T2 RH310BM directly next to bedrooms or inside tight <300 cu ft closets without ducting, due to 49 dBA sound and cool exhaust airflow.

What First Hour Rating or flow capacity does Rheem CPRO H65 T2 RH310BM deliver?

With 75 gal FHR (+3 gal vs. 72 gal median), Rheem CPRO H65 T2 RH310BM fits larger 3–5 person homes cleanly.

How do you verify manufacturing age and recall status on Rheem CPRO H65 T2 RH310BM?

CPSC SaferProducts records show 4 brand-level recall notices mentioning Rheem as of 2026-11-23, including #16177 (2016-05-26). Enter the rating-plate serial into TapAndPipe's Serial Lookup tool to verify production week.

Does Rheem CPRO H65 T2 RH310BM qualify for DOE HEAR incentives after 25C expired?

After 25C sunset on Dec 31, 2025 under OBBBA, check state DOE HEAR (up to $1,750 income-qualified) and utility rebates for Rheem CPRO H65 T2 RH310BM. Closest peer in Hybrid/Electric Heat Pump is Friedrich PROH65 T2 FD310BM (3.5 UEF).

Sources

  1. ENERGY STAR Certified Water Heaters Dataset (Socrata pbpq-swnu) — U.S. EPA & DOE ENERGY STAR, 2026 Live Certified Registry (retrieved 2026-11-23)
  2. 10 CFR 430.32 — Energy and Water Conservation Standards (Water Heaters & Plumbing Fixtures) — U.S. Department of Energy / eCFR, 2026 eCFR (incl. May 6, 2029 Rule) (retrieved 2026-11-23)
  3. CPSC SaferProducts.gov Product Recalls REST API — U.S. Consumer Product Safety Commission, 2026 Live Recalls Feed (retrieved 2026-11-23)
  4. EIA Electric Power Monthly Table 5.6.A — Average Residential Electricity Price by State — U.S. Energy Information Administration (EIA), August 2026 Monthly Release (retrieved 2026-11-23)

Related U.S. Metro Plumbing Benchmarks