Skip to main content
ENERGY STAR water heater model · PD 3478046

VAUGHN THERMAL ME65HPT-CN Water Heater Specifications (3.34 UEF)

Certified at 3.34 UEF across its 57-gallon nominal tank, 70 gal First Hour Rating, VAUGHN THERMAL ME65HPT-CN (Hybrid/Electric Heat Pump, Electric) places #640 of 706 out of 706 ENERGY STAR models (PD 3478046). Its May 6, 2029 10 CFR 430.32 status reads Pass: +0.84 / +33.6%. Rated annual electricity draw of 974 kWh/yr equates to roughly $177/yr ($1,769 over 10 years) at 18.16 cents/kWh. Closest certified alternative is Hubbell ME65HPT (3.34 UEF).

Uniform Energy Factor
3.34 UEF
Cohort UEF Rank
#640 of 706
First Hour Rating
70 gal
Storage Volume
57 gal
Fuel / Type
Electric / Hybrid/Electric Heat Pump
DOE 2029 Rule Status
Pass: +0.84 / +33.6%
Hybrid heat pump water heater upper shroud with brass relief valve and insulated copper risers
Hybrid heat pump water heater upper shroud with brass relief valve and insulated copper risers
Hybrid/Electric Heat Pump UEF Efficiency Distribution (706 Certified Units)Distribution of certified UEF ratings across 706 units in Hybrid/Electric Heat Pump, marking VAUGHN THERMAL ME65HPT-CN at 3.34 UEF.21130201631342031241542.52 UEF4.50 UEFMedian 3.702029 min 2.50VAUGHN THERMAL ME65HPT-CN: 3.34
Hybrid/Electric Heat Pump UEF Efficiency Distribution (706 Certified Units). Highlighted pin shows VAUGHN THERMAL ME65HPT-CN relative to the cohort median.
Efficiency comparison & rule summary

Tested at 3.34 UEF, VAUGHN THERMAL ME65HPT-CN places #640 of 706 across 706 certified Hybrid/Electric Heat Pump configurations (-0.36 UEF vs. 3.70 UEF median).

VAUGHN THERMAL ME65HPT-CN clears 10 CFR 430.32(d)(2) Electric >55 to <=120 gal (2.50 UEF) by +0.84 UEF (+33.6% headroom). At EIA August 2026 national rates (18.16 cents/kWh), 974 kWh/yr for VAUGHN THERMAL ME65HPT-CN runs ~$177/yr vs. ~$642/yr for a 0.92 UEF electric tank.

State electric sensitivity for VAUGHN THERMAL ME65HPT-CN: 10-year operating spend spans $1,425 in Washington (Lowest Hydro Tier) (14.63 cents/kWh) to $4,595 in Hawaii (Highest EIA State) (47.18 cents/kWh).

Closest alternatives to VAUGHN THERMAL ME65HPT-CN include Hubbell ME65HPT (3.34 UEF, at parity) alongside Noritz NHP65 (3.34 UEF, at parity).

How Do VAUGHN THERMAL ME65HPT-CN Specs Compare to Hybrid/Electric Heat Pump Medians?

VAUGHN THERMAL ME65HPT-CN places #640 of 706 across 706 certified Hybrid/Electric Heat Pump configurations, with physical dimensions, draw profile, and thermal metrics benchmarked below.

Certified model attributes compared against 706 ENERGY STAR Hybrid/Electric Heat Pump peers
Specification AttributeCertified ValueCohort Benchmark / DeltaProvenance
Manufacturer / BrandVAUGHN THERMAL13 certified listingsENERGY STAR PD 3478046
Model NumberME65HPT-CNDraw pattern: Medium-UsageME65HPT-CN
Uniform Energy Factor (UEF)3.34-0.36 UEF vs. 3.70 UEF median10 CFR 430 Test Method
First Hour Rating (FHR)70 gal-2 gal vs. 72 gal median10 CFR 430 Recovery Test
Rated Annual Electricity Use974 kWh/yr-98 kWh/yr vs. 1,072 kWh/yr medianEst. $177/yr @ $0.1816/kWh (EIA US Avg)
Thermal Recovery Efficiency368%-61.0 pts vs. 429.0% medianENERGY STAR Dataset
Physical Envelope (H x Dia)63.8" H x 28" DFits standard 72 in. basement/garage clearance; tight at 28 in. door (28" D)Doorway & ceiling check
Electrical Circuit Requirements240 V / 23 A maxRequires 240V dedicated branch circuit; check panel capacityNEC / Branch circuit check
Heat Pump Refrigerant & GWPR-134a (GWP:1430)Check regional AIM Act phase-down transitionEPA AIM Act Compliance
Sound Pressure Level54 dBA+5 dBA vs. 49 dBA medianIndoor placement check
Certification Date2024-08-13Certified 2024-08-13Markets: United States, Canada

What Does ME65HPT-CN Cost to Operate Across State Electricity Rates?

At 974 kWh/yr, VAUGHN THERMAL ME65HPT-CN runs roughly $177/yr on the EIA national average tier under August 2026 Table 5.6.A rates.

Estimated Annual Electricity Cost by State Rate (974 kWh/yr)Projected annual electricity spend across five benchmark EIA August 2026 residential electric tiers.United States Average$177.00/yrHawaii$460.00/yrCalifornia$290.00/yrTexas$155.00/yrWashington$142.00/yr
Projected annual electricity spend across five benchmark EIA August 2026 residential electric tiers.
Estimated electricity cost and 10-year spend across benchmark states
Jurisdiction (EIA Aug 2026)Residential RateAnnual Cost10-Yr Operating Spend10-Yr Savings vs. 0.92 UEF
United States Average 18.16 ¢/kWh ($0.1816) $177/yr $1,769 $4,653
Hawaii (Highest EIA State) 47.18 ¢/kWh ($0.4718) $460/yr $4,595 $12,088
California 29.75 ¢/kWh ($0.2975) $290/yr $2,898 $7,622
Texas 15.91 ¢/kWh ($0.1591) $155/yr $1,550 $4,076
Washington (Lowest Hydro Tier) 14.63 ¢/kWh ($0.1463) $142/yr $1,425 $3,748
Estimated electricity spend (974 kWh/yr)

Condensing Gas Tankless vs. Storage Tank Flow Path & Gas Supply Engineering schematic contrasting 199,000 BTU/h condensing tankless piping (3/4 in. gas supply, Category IV PVC vent, condensate drain) against a 40,000 BTU/h atmospheric tank. Condensing Gas Tankless (0.91–0.96 UEF) Secondary HX Cat IV PVC Vent Cold In Hot Out 3/4"–1" Gas 199K BTU/h Condensate Atmospheric Storage Tank (0.58–0.65 UEF) Type B Flue Anode Rod 40K BTU/h 1/2" Gas Up to 100 ft T&P 150 psi 50–85 gal FHR Reserve | 8–12 yr life
Technical comparison: condensing gas tankless units require 3/4 in.–1 in. IFGC Table 402.4 gas supply and Category IV condensate drainage, while atmospheric tanks run on 1/2 in. lines.

Are There Active CPSC Safety Recalls for VAUGHN THERMAL Water Heaters?

Zero active CPSC recalls matched VAUGHN THERMAL in our 2026-11-23 SaferProducts sweep; verify your individual tank date code via our lookup tool. See Serial Number Lookup.

Which Certified Water Heaters Match ME65HPT-CN Most Closely?

These 5 competing Hybrid/Electric Heat Pump units sit nearest to VAUGHN THERMAL ME65HPT-CN by storage capacity and 3.34 UEF rating.

5 closest certified peers matched by equipment class, storage volume, and efficiency rating
Brand & ModelTypeVolFHRUEF (Δ)kWh/yr
Hubbell ME65HPT Hybrid/Electric Heat Pump 57 gal 70 gal 3.34 (at parity) 974
Noritz NHP65 Hybrid/Electric Heat Pump 57 gal 70 gal 3.34 (at parity) 974
Friedrich PROH65 T2 FD310BM Hybrid/Electric Heat Pump 59 gal 75 gal 3.5 (+0.16) 900
Rheem CPRO H65 T2 RH310BM Hybrid/Electric Heat Pump 59 gal 75 gal 3.5 (+0.16) 900
Friedrich PROH65 T2 FD310UM Hybrid/Electric Heat Pump 59 gal 75 gal 3.5 (+0.16) 900

Who Is VAUGHN THERMAL ME65HPT-CN Best For — and When Should You Pick Hubbell ME65HPT?

Evaluate whether VAUGHN THERMAL ME65HPT-CN's Hybrid/Electric Heat Pump architecture matches your existing mechanical room and local utility tariffs before purchasing.

Key Limitations & Exclusions

  • VAUGHN THERMAL ME65HPT-CN needs >=450 cu ft room air volume or ducting so compressor cooling does not stall recovery.
  • Compressor runs near 54 dBA; avoid mounting VAUGHN THERMAL ME65HPT-CN directly beside quiet bedrooms.
  • Requires condensate drain routing and 240V electrical capacity; verify state DOE HEAR status.

Which Option Fits Your Situation?

High Electric Rate States Choosing VAUGHN THERMAL ME65HPT-CN Strong Fit — 3.34 UEF trims electric use ~75% vs 0.92 UEF tanks.
Open Basement or Garage (>=450 cu ft) Strong Fit — Ample ambient air sustains heat-pump-only efficiency.
Small Interior Closet (<300 cu ft) Caution — Add duct kit or compare Hubbell ME65HPT footprint.

What Are the Key Questions About VAUGHN THERMAL ME65HPT-CN?

Direct answers to common technical, regulatory, and sizing questions sourced from primary U.S. government and OEM documentation.

How does VAUGHN THERMAL ME65HPT-CN (3.34 UEF) compare to 2029 federal DOE floors?

Evaluated against May 6, 2029 10 CFR 430.32 thresholds, VAUGHN THERMAL ME65HPT-CN records 3.34 UEF (Pass: +0.84 / +33.6%), placing #640 of 706 out of 706 certified Hybrid/Electric Heat Pump configurations.

Does VAUGHN THERMAL ME65HPT-CN fit inside a tight hallway closet or low-headroom utility room?

VAUGHN THERMAL ME65HPT-CN requires room for its 63.8 in. vertical shell and 28 in. diameter (fits standard 72 in. basement/garage clearance; tight at 28 in. door (28" d)), plus service access for annual sediment draining.

What power supply or fuel line specs govern VAUGHN THERMAL ME65HPT-CN?

For VAUGHN THERMAL ME65HPT-CN, plan a 240V circuit at 23A max (Requires 240V dedicated branch circuit; check panel capacity) and keep a dedicated shutoff disconnect within sight of the unit.

What annual utility bill should homeowners budget for VAUGHN THERMAL ME65HPT-CN?

Using 974 kWh/yr, VAUGHN THERMAL ME65HPT-CN generates an estimated $177/yr electric bill at 18.16 cents/kWh (ranging from $142/yr in Washington hydro tiers up to $460/yr in Hawaii)—use the custom rate slider above for your utility tariff.

What are the main drawbacks of VAUGHN THERMAL ME65HPT-CN (3.34 UEF)?

VAUGHN THERMAL ME65HPT-CN requires >=450 cu ft air space, 240V electrical supply, and drain access; tight interior alcoves favor ducted adapters or Hubbell ME65HPT.

What hot-water delivery rating governs VAUGHN THERMAL ME65HPT-CN?

Rated for 70 gal FHR (-2 gal vs. 72 gal median), VAUGHN THERMAL ME65HPT-CN prevents mid-morning cold drops when matched to 55–70+ gal multi-bath household loads.

Where do homeowners screen VAUGHN THERMAL ME65HPT-CN for recalls and tank age?

Verified clean against 2026-11-23 CPSC recall feeds for VAUGHN THERMAL; use our browser-only serial decoder to inspect VAUGHN THERMAL ME65HPT-CN's age and warranty window.

What alternative models sit closest to VAUGHN THERMAL ME65HPT-CN in the Hybrid/Electric Heat Pump class?

Closest peer in Hybrid/Electric Heat Pump is Hubbell ME65HPT (3.34 UEF). For 2026 incentives, look to state DOE HEAR grants ($1,750 max on qualifying HPWHs) and local municipal utility credits.

Sources

  1. ENERGY STAR Certified Water Heaters Dataset (Socrata pbpq-swnu) — U.S. EPA & DOE ENERGY STAR, 2026 Live Certified Registry (retrieved 2026-11-23)
  2. 10 CFR 430.32 — Energy and Water Conservation Standards (Water Heaters & Plumbing Fixtures) — U.S. Department of Energy / eCFR, 2026 eCFR (incl. May 6, 2029 Rule) (retrieved 2026-11-23)
  3. CPSC SaferProducts.gov Product Recalls REST API — U.S. Consumer Product Safety Commission, 2026 Live Recalls Feed (retrieved 2026-11-23)
  4. EIA Electric Power Monthly Table 5.6.A — Average Residential Electricity Price by State — U.S. Energy Information Administration (EIA), August 2026 Monthly Release (retrieved 2026-11-23)

Related U.S. Metro Plumbing Benchmarks