Hubbell ME80HPT Water Heater Specifications (3.48 UEF)
In the 706-unit Hybrid/Electric Heat Pump class, Hubbell ME80HPT (Electric) achieves a certified 3.48 UEF rating across its 74-gallon nominal tank, 86 gal First Hour Rating (rank #545 of 706, PD 2853344) and verifies as Pass: +0.98 / +39.2% for 2029 DOE floors. Rated annual electricity draw of 1,424 kWh/yr equates to roughly $259/yr ($2,586 over 10 years) at 18.16 cents/kWh. Closest certified alternative is Noritz NHP80 (3.48 UEF).
- Uniform Energy Factor
- 3.48 UEF
- Cohort UEF Rank
- #545 of 706
- First Hour Rating
- 86 gal
- Storage Volume
- 74 gal
- Fuel / Type
- Electric / Hybrid/Electric Heat Pump
- DOE 2029 Rule Status
- Pass: +0.98 / +39.2%

Hubbell ME80HPT records 3.48 UEF efficiency, putting it #545 of 706 among 706 Hybrid/Electric Heat Pump peers.
10 CFR 430.32(d)(2) compliance: Hubbell ME80HPT exceeds 10 CFR 430.32(d)(2) Electric >55 to <=120 gal (2.50 UEF) by +0.98 UEF (+39.2%). At EIA August 2026 national rates (18.16 cents/kWh), 1,424 kWh/yr for Hubbell ME80HPT runs ~$259/yr vs. ~$978/yr for a 0.92 UEF electric tank.
State electric sensitivity for Hubbell ME80HPT: 10-year operating spend spans $2,083 in Washington (Lowest Hydro Tier) (14.63 cents/kWh) to $6,718 in Hawaii (Highest EIA State) (47.18 cents/kWh).
Competing options beside Hubbell ME80HPT (3.48 UEF) are Noritz NHP80 (3.48 UEF, at parity) and VAUGHN THERMAL ME80HPT (3.48 UEF, at parity).
What Physical and Thermal Ratings Define Hubbell ME80HPT?
Positioning at #545 of 706 out of 706 Hybrid/Electric Heat Pump peers, Hubbell ME80HPT pairs measured UEF performance with specific clearance and wiring rules.
| Specification Attribute | Certified Value | Cohort Benchmark / Delta | Provenance |
|---|---|---|---|
| Manufacturer / Brand | Hubbell | 4 certified listings | ENERGY STAR PD 2853344 |
| Model Number | ME80HPT | Draw pattern: High-Usage | ME80HPT |
| Uniform Energy Factor (UEF) | 3.48 | -0.22 UEF vs. 3.70 UEF median | 10 CFR 430 Test Method |
| First Hour Rating (FHR) | 86 gal | +14 gal vs. 72 gal median | 10 CFR 430 Recovery Test |
| Rated Annual Electricity Use | 1,424 kWh/yr | +352 kWh/yr vs. 1,072 kWh/yr median | Est. $259/yr @ $0.1816/kWh (EIA US Avg) |
| Thermal Recovery Efficiency | 365% | -64.0 pts vs. 429.0% median | ENERGY STAR Dataset |
| Physical Envelope (H x Dia) | 74" H x 28" D | Needs >72 in. overhead clearance; tight at 28 in. door (28" D) | Doorway & ceiling check |
| Electrical Circuit Requirements | 240 V / 23 A max | Requires 240V dedicated branch circuit; check panel capacity | NEC / Branch circuit check |
| Heat Pump Refrigerant & GWP | R-134a (GWP:1430) | Check regional AIM Act phase-down transition | EPA AIM Act Compliance |
| Sound Pressure Level | 54 dBA | +5 dBA vs. 49 dBA median | Indoor placement check |
| Certification Date | 2023-12-13 | Certified 2023-12-13 | Markets: United States, Canada |
Why Do State Utility Rates Shift ME80HPT Running Costs?
Consuming 1,424 kWh annually puts Hubbell ME80HPT near $259/yr at US baseline tariffs, with multi-state EIA comparisons charted below.
| Jurisdiction (EIA Aug 2026) | Residential Rate | Annual Cost | 10-Yr Operating Spend | 10-Yr Savings vs. 0.92 UEF |
|---|---|---|---|---|
| United States Average | 18.16 ¢/kWh ($0.1816) | $259/yr | $2,586 | $7,195 |
| Hawaii (Highest EIA State) | 47.18 ¢/kWh ($0.4718) | $672/yr | $6,718 | $18,693 |
| California | 29.75 ¢/kWh ($0.2975) | $424/yr | $4,236 | $11,787 |
| Texas | 15.91 ¢/kWh ($0.1591) | $227/yr | $2,266 | $6,304 |
| Washington (Lowest Hydro Tier) | 14.63 ¢/kWh ($0.1463) | $208/yr | $2,083 | $5,796 |
Have Any Hubbell Series Triggered CPSC Recalls?
SaferProducts screening on 2026-11-23 returned zero recall matches for Hubbell; confirm tank age separately using the rating-plate serial pattern. See Serial Number Lookup.
What Are 5 Direct Alternatives to Hubbell ME80HPT?
Homeowners cross-shopping Hubbell ME80HPT frequently review these five Hybrid/Electric Heat Pump models ranked closest on capacity and UEF output.
| Brand & Model | Type | Vol | FHR | UEF (Δ) | kWh/yr |
|---|---|---|---|---|---|
| Noritz NHP80 | Hybrid/Electric Heat Pump | 74 gal | 86 gal | 3.48 (at parity) | 1,424 |
| VAUGHN THERMAL ME80HPT | Hybrid/Electric Heat Pump | 74 gal | 86 gal | 3.48 (at parity) | 1,424 |
| 1HVAC ACIQ-80G-HP-WH | Hybrid/Electric Heat Pump | 74 gal | 91 gal | 4.0 (+0.52) | 1,240 |
| ACIQ ACIQ-80G-HP-WH | Hybrid/Electric Heat Pump | 74 gal | 91 gal | 4.0 (+0.52) | 1,240 |
| VAUGHN THERMAL ME80HPT-CN | Hybrid/Electric Heat Pump | 74 gal | 86 gal | 3.48 (at parity) | 1,424 |
Who Is Hubbell ME80HPT Best For — and When Should You Pick Noritz NHP80?
Evaluate whether Hubbell ME80HPT's Hybrid/Electric Heat Pump architecture matches your existing mechanical room and local utility tariffs before purchasing.
Key Limitations & Exclusions
- Hubbell ME80HPT needs >=450 cu ft room air volume or ducting so compressor cooling does not stall recovery.
- Compressor runs near 54 dBA; avoid mounting Hubbell ME80HPT directly beside quiet bedrooms.
- Requires condensate drain routing and 240V electrical capacity; verify state DOE HEAR status.
Which Option Fits Your Situation?
Sizing, Efficiency & Recall Answers for Hubbell ME80HPT
Direct answers to common technical, regulatory, and sizing questions sourced from primary U.S. government and OEM documentation.
How does Hubbell ME80HPT (3.48 UEF) compare to 2029 federal DOE floors?
Evaluated against May 6, 2029 10 CFR 430.32 thresholds, Hubbell ME80HPT records 3.48 UEF (Pass: +0.98 / +39.2%), placing #545 of 706 out of 706 certified Hybrid/Electric Heat Pump configurations.
Does Hubbell ME80HPT fit inside a tight hallway closet or low-headroom utility room?
Hubbell ME80HPT requires room for its 74 in. vertical shell and 28 in. diameter (needs >72 in. overhead clearance; tight at 28 in. door (28" d)), plus service access for annual sediment draining.
What power supply or fuel line specs govern Hubbell ME80HPT?
For Hubbell ME80HPT, plan a 240V circuit at 23A max (Requires 240V dedicated branch circuit; check panel capacity) and keep a dedicated shutoff disconnect within sight of the unit.
What annual utility bill should homeowners budget for Hubbell ME80HPT?
Using 1,424 kWh/yr, Hubbell ME80HPT generates an estimated $259/yr electric bill at 18.16 cents/kWh (ranging from $208/yr in Washington hydro tiers up to $672/yr in Hawaii)—use the custom rate slider above for your utility tariff.
What are the main drawbacks of Hubbell ME80HPT (3.48 UEF)?
Hubbell ME80HPT requires >=450 cu ft air space, 240V electrical supply, and drain access; tight interior alcoves favor ducted adapters or Noritz NHP80.
What hot-water delivery rating governs Hubbell ME80HPT?
Rated for 86 gal FHR (+14 gal vs. 72 gal median), Hubbell ME80HPT prevents mid-morning cold drops when matched to 55–70+ gal multi-bath household loads.
Where do homeowners screen Hubbell ME80HPT for recalls and tank age?
Verified clean against 2026-11-23 CPSC recall feeds for Hubbell; use our browser-only serial decoder to inspect Hubbell ME80HPT's age and warranty window.
What alternative models sit closest to Hubbell ME80HPT in the Hybrid/Electric Heat Pump class?
Closest peer in Hybrid/Electric Heat Pump is Noritz NHP80 (3.48 UEF). For 2026 incentives, look to state DOE HEAR grants ($1,750 max on qualifying HPWHs) and local municipal utility credits.
Sources
- ENERGY STAR Certified Water Heaters Dataset (Socrata pbpq-swnu) — U.S. EPA & DOE ENERGY STAR, 2026 Live Certified Registry (retrieved 2026-11-23)
- 10 CFR 430.32 — Energy and Water Conservation Standards (Water Heaters & Plumbing Fixtures) — U.S. Department of Energy / eCFR, 2026 eCFR (incl. May 6, 2029 Rule) (retrieved 2026-11-23)
- CPSC SaferProducts.gov Product Recalls REST API — U.S. Consumer Product Safety Commission, 2026 Live Recalls Feed (retrieved 2026-11-23)
- EIA Electric Power Monthly Table 5.6.A — Average Residential Electricity Price by State — U.S. Energy Information Administration (EIA), August 2026 Monthly Release (retrieved 2026-11-23)