Noritz NHP80 Water Heater Specifications (3.48 UEF)
The Noritz NHP80 (Hybrid/Electric Heat Pump, Electric) achieves a certified 3.48 UEF rating across its 74-gallon nominal tank, 86 gal First Hour Rating, ranking #545 of 706 among 706 ENERGY STAR Hybrid/Electric Heat Pump models (PD 3798600). Under the May 6, 2029 DOE 10 CFR 430.32(d)(2) standard, compliance status is Pass: +0.98 / +39.2%. Rated annual electricity draw of 1,424 kWh/yr equates to roughly $259/yr ($2,586 over 10 years) at 18.16 cents/kWh. Closest certified alternative is Hubbell ME80HPT (3.48 UEF).
- Uniform Energy Factor
- 3.48 UEF
- Cohort UEF Rank
- #545 of 706
- First Hour Rating
- 86 gal
- Storage Volume
- 74 gal
- Fuel / Type
- Electric / Hybrid/Electric Heat Pump
- DOE 2029 Rule Status
- Pass: +0.98 / +39.2%

Noritz NHP80 (3.48 UEF) ranks #545 of 706 Hybrid/Electric Heat Pump models — 4-way tie; more efficient than 22.4% of Hybrid/Electric Heat Pump models, -0.22 UEF below the 3.70 UEF median.
Federal 2029 margin for Noritz NHP80: +0.98 UEF (+39.2%) vs. 10 CFR 430.32(d)(2) Electric >55 to <=120 gal (2.50 UEF). At EIA August 2026 national rates (18.16 cents/kWh), 1,424 kWh/yr for Noritz NHP80 runs ~$259/yr vs. ~$978/yr for a 0.92 UEF electric tank.
State electric sensitivity for Noritz NHP80: 10-year operating spend spans $2,083 in Washington (Lowest Hydro Tier) (14.63 cents/kWh) to $6,718 in Hawaii (Highest EIA State) (47.18 cents/kWh).
Peer comparison: Noritz NHP80 (3.48 UEF) compares closely with Hubbell ME80HPT (3.48 UEF, at parity) and VAUGHN THERMAL ME80HPT (3.48 UEF, at parity).
What Physical and Thermal Ratings Define Noritz NHP80?
Positioning at #545 of 706 out of 706 Hybrid/Electric Heat Pump peers, Noritz NHP80 pairs measured UEF performance with specific clearance and wiring rules.
| Specification Attribute | Certified Value | Cohort Benchmark / Delta | Provenance |
|---|---|---|---|
| Manufacturer / Brand | Noritz | 23 certified listings | ENERGY STAR PD 3798600 |
| Model Number | NHP80 | Draw pattern: High-Usage | NHP80 |
| Uniform Energy Factor (UEF) | 3.48 | -0.22 UEF vs. 3.70 UEF median | 10 CFR 430 Test Method |
| First Hour Rating (FHR) | 86 gal | +14 gal vs. 72 gal median | 10 CFR 430 Recovery Test |
| Rated Annual Electricity Use | 1,424 kWh/yr | +352 kWh/yr vs. 1,072 kWh/yr median | Est. $259/yr @ $0.1816/kWh (EIA US Avg) |
| Thermal Recovery Efficiency | 365% | -64.0 pts vs. 429.0% median | ENERGY STAR Dataset |
| Physical Envelope (H x Dia) | 74" H x 28" D | Needs >72 in. overhead clearance; tight at 28 in. door (28" D) | Doorway & ceiling check |
| Electrical Circuit Requirements | 240 V / 23 A max | Requires 240V dedicated branch circuit; check panel capacity | NEC / Branch circuit check |
| Heat Pump Refrigerant & GWP | R-134a (GWP:1430) | Check regional AIM Act phase-down transition | EPA AIM Act Compliance |
| Sound Pressure Level | 54 dBA | +5 dBA vs. 49 dBA median | Indoor placement check |
| Certification Date | 2024-11-12 | Certified 2024-11-12 | Markets: United States, Canada |
Why Do State Utility Rates Shift NHP80 Running Costs?
Consuming 1,424 kWh annually puts Noritz NHP80 near $259/yr at US baseline tariffs, with multi-state EIA comparisons charted below.
| Jurisdiction (EIA Aug 2026) | Residential Rate | Annual Cost | 10-Yr Operating Spend | 10-Yr Savings vs. 0.92 UEF |
|---|---|---|---|---|
| United States Average | 18.16 ¢/kWh ($0.1816) | $259/yr | $2,586 | $7,195 |
| Hawaii (Highest EIA State) | 47.18 ¢/kWh ($0.4718) | $672/yr | $6,718 | $18,693 |
| California | 29.75 ¢/kWh ($0.2975) | $424/yr | $4,236 | $11,787 |
| Texas | 15.91 ¢/kWh ($0.1591) | $227/yr | $2,266 | $6,304 |
| Washington (Lowest Hydro Tier) | 14.63 ¢/kWh ($0.1463) | $208/yr | $2,083 | $5,796 |
Have Any Noritz Series Triggered CPSC Recalls?
SaferProducts screening on 2026-11-23 returned zero recall matches for Noritz; confirm tank age separately using the rating-plate serial pattern. See Serial Number Lookup.
What Are 5 Direct Alternatives to Noritz NHP80?
Homeowners cross-shopping Noritz NHP80 frequently review these five Hybrid/Electric Heat Pump models ranked closest on capacity and UEF output.
| Brand & Model | Type | Vol | FHR | UEF (Δ) | kWh/yr |
|---|---|---|---|---|---|
| Hubbell ME80HPT | Hybrid/Electric Heat Pump | 74 gal | 86 gal | 3.48 (at parity) | 1,424 |
| VAUGHN THERMAL ME80HPT | Hybrid/Electric Heat Pump | 74 gal | 86 gal | 3.48 (at parity) | 1,424 |
| 1HVAC ACIQ-80G-HP-WH | Hybrid/Electric Heat Pump | 74 gal | 91 gal | 4.0 (+0.52) | 1,240 |
| ACIQ ACIQ-80G-HP-WH | Hybrid/Electric Heat Pump | 74 gal | 91 gal | 4.0 (+0.52) | 1,240 |
| VAUGHN THERMAL ME80HPT-CN | Hybrid/Electric Heat Pump | 74 gal | 86 gal | 3.48 (at parity) | 1,424 |
Which Home Setups Are NOT a Fit for Noritz NHP80?
Comparing Noritz NHP80 against Hubbell ME80HPT requires checking closet airflow, IFGC gas or 240V electrical sizing, and May 6, 2029 compliance.
Key Limitations & Exclusions
- Noritz NHP80 needs >=450 cu ft room air volume or ducting so compressor cooling does not stall recovery.
- Compressor runs near 54 dBA; avoid mounting Noritz NHP80 directly beside quiet bedrooms.
- Requires condensate drain routing and 240V electrical capacity; verify state DOE HEAR status.
Which Option Fits Your Situation?
Sizing, Efficiency & Recall Answers for Noritz NHP80
Direct answers to common technical, regulatory, and sizing questions sourced from primary U.S. government and OEM documentation.
How does Noritz NHP80 score under 10 CFR 430.32 May 2029 water heater minimums?
Federal 10 CFR 430.32 rules set the May 6, 2029 manufacturing baseline; Noritz NHP80 logs 3.48 UEF (Pass: +0.98 / +39.2%) within the 706-unit Hybrid/Electric Heat Pump group.
What physical clearance dimensions apply when installing Noritz NHP80?
With a 74 in. height and 28 in. diameter, Noritz NHP80 fits spaces matching: needs >72 in. overhead clearance; tight at 28 in. door (28" d), plus 6–12 in. above for plumbing shutoffs.
What 240V circuit or IFGC fuel line capacity fits Noritz NHP80?
Powered via 240V at 23A max, Noritz NHP80 requires: Requires 240V dedicated branch circuit; check panel capacity. Confirm double-pole breaker sizing and condensate pump outlet proximity.
How do state electricity prices change annual costs for Noritz NHP80?
Annual electric spend for Noritz NHP80 (1,424 kWh/yr) averages $259/yr nationwide (ranging from $208/yr in Washington hydro tiers up to $672/yr in Hawaii), calculated directly from August 2026 EIA Table 5.6.A tariffs.
What homeowner setups should avoid choosing Noritz NHP80?
Homes lacking a condensate drain or 240V branch circuit—or unconditioned sub-zero spaces—should verify hybrid backup mode limits on Noritz NHP80.
Is Noritz NHP80 sized adequately for a 2-to-4-person household?
ENERGY STAR certifies Noritz NHP80 at 86 gal First Hour Rating (+14 gal vs. 72 gal median); match that hourly reserve against simultaneous 2.0 GPM showerheads.
Does Noritz have active CPSC SaferProducts notices affecting NHP80?
Zero CPSC recall alerts matched Noritz (2026-11-23 check). Keep your Noritz NHP80 serial code handy to track standard 6-to-12-year OEM warranty coverage.
Which competing water heater matches Noritz NHP80 (3.48 UEF) most closely?
State-run DOE HEAR programs (<=150% AMI, up to $1,750 for HPWH) and electric utilities lead 2026 incentives for Noritz NHP80. Closest peer in Hybrid/Electric Heat Pump is Hubbell ME80HPT (3.48 UEF).
Sources
- ENERGY STAR Certified Water Heaters Dataset (Socrata pbpq-swnu) — U.S. EPA & DOE ENERGY STAR, 2026 Live Certified Registry (retrieved 2026-11-23)
- 10 CFR 430.32 — Energy and Water Conservation Standards (Water Heaters & Plumbing Fixtures) — U.S. Department of Energy / eCFR, 2026 eCFR (incl. May 6, 2029 Rule) (retrieved 2026-11-23)
- CPSC SaferProducts.gov Product Recalls REST API — U.S. Consumer Product Safety Commission, 2026 Live Recalls Feed (retrieved 2026-11-23)
- EIA Electric Power Monthly Table 5.6.A — Average Residential Electricity Price by State — U.S. Energy Information Administration (EIA), August 2026 Monthly Release (retrieved 2026-11-23)