Skip to main content
ENERGY STAR water heater model · PD 4439733

JETGLAS RE2HP50*-1NCTT Water Heater Specifications (3.89 UEF)

With PD 4439733 certification, JETGLAS RE2HP50*-1NCTT (Hybrid/Electric Heat Pump, Electric) achieves a certified 3.89 UEF rating across its 45-gallon nominal tank, 65 gal First Hour Rating, standing #163 of 706 across 706 peers with Pass: +1.59 / +69.1% for May 6, 2029. Rated annual electricity draw of 835 kWh/yr equates to roughly $152/yr ($1,516 over 10 years) at 18.16 cents/kWh. Closest certified alternative is Bradford White RE2HP50**-1NCTT (3.89 UEF).

Uniform Energy Factor
3.89 UEF
Cohort UEF Rank
#163 of 706 (top 23.2%)
First Hour Rating
65 gal
Storage Volume
45 gal
Fuel / Type
Electric / Hybrid/Electric Heat Pump
DOE 2029 Rule Status
Pass: +1.59 / +69.1%
Hybrid heat pump water heater upper shroud with brass relief valve and insulated copper risers
Hybrid heat pump water heater upper shroud with brass relief valve and insulated copper risers
Hybrid/Electric Heat Pump UEF Efficiency Distribution (706 Certified Units)Distribution of certified UEF ratings across 706 units in Hybrid/Electric Heat Pump, marking JETGLAS RE2HP50*-1NCTT at 3.89 UEF.21130201631342031241542.52 UEF4.50 UEFMedian 3.702029 min 2.30JETGLAS RE2HP50*-1NCTT: 3.89
Hybrid/Electric Heat Pump UEF Efficiency Distribution (706 Certified Units). Highlighted pin shows JETGLAS RE2HP50*-1NCTT relative to the cohort median.
Efficiency comparison & rule summary

ENERGY STAR certification places JETGLAS RE2HP50*-1NCTT at 3.89 UEF (#163 of 706; +0.19 UEF vs. 3.70 UEF median) in Hybrid/Electric Heat Pump.

May 6, 2029 readiness: JETGLAS RE2HP50*-1NCTT stands +1.59 UEF (+69.1%) relative to 10 CFR 430.32(d)(2) Electric >35 to <=55 gal (2.30 UEF). At EIA August 2026 national rates (18.16 cents/kWh), 835 kWh/yr for JETGLAS RE2HP50*-1NCTT runs ~$152/yr vs. ~$641/yr for a 0.92 UEF electric tank.

State electric sensitivity for JETGLAS RE2HP50*-1NCTT: 10-year operating spend spans $1,222 in Washington (Lowest Hydro Tier) (14.63 cents/kWh) to $3,940 in Hawaii (Highest EIA State) (47.18 cents/kWh).

In the Hybrid/Electric Heat Pump tier, Bradford White RE2HP50**-1NCTT (3.89 UEF, at parity) and Friedrich PROH50 T2 FD400-30 (3.88 UEF, delta -0.01) bracket JETGLAS RE2HP50*-1NCTT.

Where Does JETGLAS RE2HP50*-1NCTT Rank Against Peer Hybrid/Electric Heat Pump Units?

Audited against 706 ENERGY STAR Hybrid/Electric Heat Pump listings, JETGLAS RE2HP50*-1NCTT holds #163 of 706 (top 23.2%); inspect footprint, circuit load, and efficiency deltas here.

Certified model attributes compared against 706 ENERGY STAR Hybrid/Electric Heat Pump peers
Specification AttributeCertified ValueCohort Benchmark / DeltaProvenance
Manufacturer / BrandJETGLAS6 certified listingsENERGY STAR PD 4439733
Model NumberRE2HP50*-1NCTTDraw pattern: Medium-UsageRE2HP50*-1NCTT
Uniform Energy Factor (UEF)3.89+0.19 UEF vs. 3.70 UEF median10 CFR 430 Test Method
First Hour Rating (FHR)65 gal-7 gal vs. 72 gal median10 CFR 430 Recovery Test
Rated Annual Electricity Use835 kWh/yr-237 kWh/yr vs. 1,072 kWh/yr medianEst. $152/yr @ $0.1816/kWh (EIA US Avg)
Thermal Recovery Efficiency445%+16.0 pts vs. 429.0% medianENERGY STAR Dataset
Physical Envelope (H x Dia)46.1" H x 18" DFits standard 72 in. basement/garage clearance; clears 28 in. utility doorway (18" D)Doorway & ceiling check
Electrical Circuit Requirements240 V / 19 A maxRequires 240V dedicated branch circuit; check panel capacityNEC / Branch circuit check
Heat Pump Refrigerant & GWPR-134a (GWP:1430)Check regional AIM Act phase-down transitionEPA AIM Act Compliance
Certification Date2025-07-02Certified 2025-07-02Markets: United States

How Much Electricity Does RE2HP50*-1NCTT Use in Different States?

Estimated at $152/yr nationally (835 kWh/yr), 10-year utility spending for JETGLAS RE2HP50*-1NCTT shifts sharply between low-rate hydro and coastal grids.

Estimated Annual Electricity Cost by State Rate (835 kWh/yr)Projected annual electricity spend across five benchmark EIA August 2026 residential electric tiers.United States Average$152.00/yrHawaii$394.00/yrCalifornia$248.00/yrTexas$133.00/yrWashington$122.00/yr
Projected annual electricity spend across five benchmark EIA August 2026 residential electric tiers.
Estimated electricity cost and 10-year spend across benchmark states
Jurisdiction (EIA Aug 2026)Residential RateAnnual Cost10-Yr Operating Spend10-Yr Savings vs. 0.92 UEF
United States Average 18.16 ¢/kWh ($0.1816) $152/yr $1,516 $4,896
Hawaii (Highest EIA State) 47.18 ¢/kWh ($0.4718) $394/yr $3,940 $12,720
California 29.75 ¢/kWh ($0.2975) $248/yr $2,484 $8,021
Texas 15.91 ¢/kWh ($0.1591) $133/yr $1,328 $4,289
Washington (Lowest Hydro Tier) 14.63 ¢/kWh ($0.1463) $122/yr $1,222 $3,944
Estimated electricity spend (835 kWh/yr)

Condensing Gas Tankless vs. Storage Tank Flow Path & Gas Supply Engineering schematic contrasting 199,000 BTU/h condensing tankless piping (3/4 in. gas supply, Category IV PVC vent, condensate drain) against a 40,000 BTU/h atmospheric tank. Condensing Gas Tankless (0.91–0.96 UEF) Secondary HX Cat IV PVC Vent Cold In Hot Out 3/4"–1" Gas 199K BTU/h Condensate Atmospheric Storage Tank (0.58–0.65 UEF) Type B Flue Anode Rod 40K BTU/h 1/2" Gas Up to 100 ft T&P 150 psi 50–85 gal FHR Reserve | 8–12 yr life
Technical comparison: condensing gas tankless units require 3/4 in.–1 in. IFGC Table 402.4 gas supply and Category IV condensate drainage, while atmospheric tanks run on 1/2 in. lines.

Does CPSC Flag Any Safety Notices on JETGLAS Units?

No open CPSC recall alerts appeared for JETGLAS as of 2026-11-23; you can still decode exact manufacture month and warranty window below. See Serial Number Lookup.

Which Competing Hybrid/Electric Heat Pump Models Compare Closest to RE2HP50*-1NCTT?

Compare five nearby ENERGY STAR Hybrid/Electric Heat Pump options matched closely to JETGLAS RE2HP50*-1NCTT's gallon capacity and 3.89 UEF efficiency.

5 closest certified peers matched by equipment class, storage volume, and efficiency rating
Brand & ModelTypeVolFHRUEF (Δ)kWh/yr
Bradford White RE2HP50**-1NCTT Hybrid/Electric Heat Pump 45 gal 65 gal 3.89 (at parity) 835
Friedrich PROH50 T2 FD400-30 Hybrid/Electric Heat Pump 45 gal 67 gal 3.88 (-0.01) 846
Rheem CPROPH50 T2 RH375-SO Hybrid/Electric Heat Pump 45 gal 67 gal 3.88 (-0.01) 846
Richmond 10CE50-HP5S30 Hybrid/Electric Heat Pump 45 gal 67 gal 3.88 (-0.01) 846
Friedrich PROH50 T2 FD400-SO Hybrid/Electric Heat Pump 45 gal 67 gal 3.88 (-0.01) 846

Which Home Setups Are NOT a Fit for JETGLAS RE2HP50*-1NCTT?

Comparing JETGLAS RE2HP50*-1NCTT against Bradford White RE2HP50**-1NCTT requires checking closet airflow, IFGC gas or 240V electrical sizing, and May 6, 2029 compliance.

Key Limitations & Exclusions

  • JETGLAS RE2HP50*-1NCTT needs >=450 cu ft room air volume or ducting so compressor cooling does not stall recovery.
  • Compressor runs near 49 dBA; avoid mounting JETGLAS RE2HP50*-1NCTT directly beside quiet bedrooms.
  • Requires condensate drain routing and 240V electrical capacity; verify state DOE HEAR status.

Which Option Fits Your Situation?

High Electric Rate States Choosing JETGLAS RE2HP50*-1NCTT Strong Fit — 3.89 UEF trims electric use ~75% vs 0.92 UEF tanks.
Open Basement or Garage (>=450 cu ft) Strong Fit — Ample ambient air sustains heat-pump-only efficiency.
Small Interior Closet (<300 cu ft) Caution — Add duct kit or compare Bradford White RE2HP50**-1NCTT footprint.

Common Homeowner Questions for JETGLAS RE2HP50*-1NCTT

Direct answers to common technical, regulatory, and sizing questions sourced from primary U.S. government and OEM documentation.

How does JETGLAS RE2HP50*-1NCTT score under 10 CFR 430.32 May 2029 water heater minimums?

Federal 10 CFR 430.32 rules set the May 6, 2029 manufacturing baseline; JETGLAS RE2HP50*-1NCTT logs 3.89 UEF (Pass: +1.59 / +69.1%) within the 706-unit Hybrid/Electric Heat Pump group.

What physical clearance dimensions apply when installing JETGLAS RE2HP50*-1NCTT?

With a 46.1 in. height and 18 in. diameter, JETGLAS RE2HP50*-1NCTT fits spaces matching: fits standard 72 in. basement/garage clearance; clears 28 in. utility doorway (18" d), plus 6–12 in. above for plumbing shutoffs.

What 240V circuit or IFGC fuel line capacity fits JETGLAS RE2HP50*-1NCTT?

Powered via 240V at 19A max, JETGLAS RE2HP50*-1NCTT requires: Requires 240V dedicated branch circuit; check panel capacity. Confirm double-pole breaker sizing and condensate pump outlet proximity.

How do state electricity prices change annual costs for JETGLAS RE2HP50*-1NCTT?

Annual electric spend for JETGLAS RE2HP50*-1NCTT (835 kWh/yr) averages $152/yr nationwide (ranging from $122/yr in Washington hydro tiers up to $394/yr in Hawaii), calculated directly from August 2026 EIA Table 5.6.A tariffs.

What homeowner setups should avoid choosing JETGLAS RE2HP50*-1NCTT?

Homes lacking a condensate drain or 240V branch circuit—or unconditioned sub-zero spaces—should verify hybrid backup mode limits on JETGLAS RE2HP50*-1NCTT.

Is JETGLAS RE2HP50*-1NCTT sized adequately for a 2-to-4-person household?

ENERGY STAR certifies JETGLAS RE2HP50*-1NCTT at 65 gal First Hour Rating (-7 gal vs. 72 gal median); match that hourly reserve against simultaneous 2.0 GPM showerheads.

Does JETGLAS have active CPSC SaferProducts notices affecting RE2HP50*-1NCTT?

Zero CPSC recall alerts matched JETGLAS (2026-11-23 check). Keep your JETGLAS RE2HP50*-1NCTT serial code handy to track standard 6-to-12-year OEM warranty coverage.

Which competing water heater matches JETGLAS RE2HP50*-1NCTT (3.89 UEF) most closely?

State-run DOE HEAR programs (<=150% AMI, up to $1,750 for HPWH) and electric utilities lead 2026 incentives for JETGLAS RE2HP50*-1NCTT. Closest peer in Hybrid/Electric Heat Pump is Bradford White RE2HP50**-1NCTT (3.89 UEF).

Sources

  1. ENERGY STAR Certified Water Heaters Dataset (Socrata pbpq-swnu) — U.S. EPA & DOE ENERGY STAR, 2026 Live Certified Registry (retrieved 2026-11-23)
  2. 10 CFR 430.32 — Energy and Water Conservation Standards (Water Heaters & Plumbing Fixtures) — U.S. Department of Energy / eCFR, 2026 eCFR (incl. May 6, 2029 Rule) (retrieved 2026-11-23)
  3. CPSC SaferProducts.gov Product Recalls REST API — U.S. Consumer Product Safety Commission, 2026 Live Recalls Feed (retrieved 2026-11-23)
  4. EIA Electric Power Monthly Table 5.6.A — Average Residential Electricity Price by State — U.S. Energy Information Administration (EIA), August 2026 Monthly Release (retrieved 2026-11-23)

Related U.S. Metro Plumbing Benchmarks