JETGLAS RE2HP50*-1NCTT Water Heater Specifications (3.89 UEF)
With PD 4439733 certification, JETGLAS RE2HP50*-1NCTT (Hybrid/Electric Heat Pump, Electric) achieves a certified 3.89 UEF rating across its 45-gallon nominal tank, 65 gal First Hour Rating, standing #163 of 706 across 706 peers with Pass: +1.59 / +69.1% for May 6, 2029. Rated annual electricity draw of 835 kWh/yr equates to roughly $152/yr ($1,516 over 10 years) at 18.16 cents/kWh. Closest certified alternative is Bradford White RE2HP50**-1NCTT (3.89 UEF).
- Uniform Energy Factor
- 3.89 UEF
- Cohort UEF Rank
- #163 of 706 (top 23.2%)
- First Hour Rating
- 65 gal
- Storage Volume
- 45 gal
- Fuel / Type
- Electric / Hybrid/Electric Heat Pump
- DOE 2029 Rule Status
- Pass: +1.59 / +69.1%

ENERGY STAR certification places JETGLAS RE2HP50*-1NCTT at 3.89 UEF (#163 of 706; +0.19 UEF vs. 3.70 UEF median) in Hybrid/Electric Heat Pump.
May 6, 2029 readiness: JETGLAS RE2HP50*-1NCTT stands +1.59 UEF (+69.1%) relative to 10 CFR 430.32(d)(2) Electric >35 to <=55 gal (2.30 UEF). At EIA August 2026 national rates (18.16 cents/kWh), 835 kWh/yr for JETGLAS RE2HP50*-1NCTT runs ~$152/yr vs. ~$641/yr for a 0.92 UEF electric tank.
State electric sensitivity for JETGLAS RE2HP50*-1NCTT: 10-year operating spend spans $1,222 in Washington (Lowest Hydro Tier) (14.63 cents/kWh) to $3,940 in Hawaii (Highest EIA State) (47.18 cents/kWh).
In the Hybrid/Electric Heat Pump tier, Bradford White RE2HP50**-1NCTT (3.89 UEF, at parity) and Friedrich PROH50 T2 FD400-30 (3.88 UEF, delta -0.01) bracket JETGLAS RE2HP50*-1NCTT.
Where Does JETGLAS RE2HP50*-1NCTT Rank Against Peer Hybrid/Electric Heat Pump Units?
Audited against 706 ENERGY STAR Hybrid/Electric Heat Pump listings, JETGLAS RE2HP50*-1NCTT holds #163 of 706 (top 23.2%); inspect footprint, circuit load, and efficiency deltas here.
| Specification Attribute | Certified Value | Cohort Benchmark / Delta | Provenance |
|---|---|---|---|
| Manufacturer / Brand | JETGLAS | 6 certified listings | ENERGY STAR PD 4439733 |
| Model Number | RE2HP50*-1NCTT | Draw pattern: Medium-Usage | RE2HP50*-1NCTT |
| Uniform Energy Factor (UEF) | 3.89 | +0.19 UEF vs. 3.70 UEF median | 10 CFR 430 Test Method |
| First Hour Rating (FHR) | 65 gal | -7 gal vs. 72 gal median | 10 CFR 430 Recovery Test |
| Rated Annual Electricity Use | 835 kWh/yr | -237 kWh/yr vs. 1,072 kWh/yr median | Est. $152/yr @ $0.1816/kWh (EIA US Avg) |
| Thermal Recovery Efficiency | 445% | +16.0 pts vs. 429.0% median | ENERGY STAR Dataset |
| Physical Envelope (H x Dia) | 46.1" H x 18" D | Fits standard 72 in. basement/garage clearance; clears 28 in. utility doorway (18" D) | Doorway & ceiling check |
| Electrical Circuit Requirements | 240 V / 19 A max | Requires 240V dedicated branch circuit; check panel capacity | NEC / Branch circuit check |
| Heat Pump Refrigerant & GWP | R-134a (GWP:1430) | Check regional AIM Act phase-down transition | EPA AIM Act Compliance |
| Certification Date | 2025-07-02 | Certified 2025-07-02 | Markets: United States |
How Much Electricity Does RE2HP50*-1NCTT Use in Different States?
Estimated at $152/yr nationally (835 kWh/yr), 10-year utility spending for JETGLAS RE2HP50*-1NCTT shifts sharply between low-rate hydro and coastal grids.
| Jurisdiction (EIA Aug 2026) | Residential Rate | Annual Cost | 10-Yr Operating Spend | 10-Yr Savings vs. 0.92 UEF |
|---|---|---|---|---|
| United States Average | 18.16 ¢/kWh ($0.1816) | $152/yr | $1,516 | $4,896 |
| Hawaii (Highest EIA State) | 47.18 ¢/kWh ($0.4718) | $394/yr | $3,940 | $12,720 |
| California | 29.75 ¢/kWh ($0.2975) | $248/yr | $2,484 | $8,021 |
| Texas | 15.91 ¢/kWh ($0.1591) | $133/yr | $1,328 | $4,289 |
| Washington (Lowest Hydro Tier) | 14.63 ¢/kWh ($0.1463) | $122/yr | $1,222 | $3,944 |
Does CPSC Flag Any Safety Notices on JETGLAS Units?
No open CPSC recall alerts appeared for JETGLAS as of 2026-11-23; you can still decode exact manufacture month and warranty window below. See Serial Number Lookup.
Which Competing Hybrid/Electric Heat Pump Models Compare Closest to RE2HP50*-1NCTT?
Compare five nearby ENERGY STAR Hybrid/Electric Heat Pump options matched closely to JETGLAS RE2HP50*-1NCTT's gallon capacity and 3.89 UEF efficiency.
| Brand & Model | Type | Vol | FHR | UEF (Δ) | kWh/yr |
|---|---|---|---|---|---|
| Bradford White RE2HP50**-1NCTT | Hybrid/Electric Heat Pump | 45 gal | 65 gal | 3.89 (at parity) | 835 |
| Friedrich PROH50 T2 FD400-30 | Hybrid/Electric Heat Pump | 45 gal | 67 gal | 3.88 (-0.01) | 846 |
| Rheem CPROPH50 T2 RH375-SO | Hybrid/Electric Heat Pump | 45 gal | 67 gal | 3.88 (-0.01) | 846 |
| Richmond 10CE50-HP5S30 | Hybrid/Electric Heat Pump | 45 gal | 67 gal | 3.88 (-0.01) | 846 |
| Friedrich PROH50 T2 FD400-SO | Hybrid/Electric Heat Pump | 45 gal | 67 gal | 3.88 (-0.01) | 846 |
Which Home Setups Are NOT a Fit for JETGLAS RE2HP50*-1NCTT?
Comparing JETGLAS RE2HP50*-1NCTT against Bradford White RE2HP50**-1NCTT requires checking closet airflow, IFGC gas or 240V electrical sizing, and May 6, 2029 compliance.
Key Limitations & Exclusions
- JETGLAS RE2HP50*-1NCTT needs >=450 cu ft room air volume or ducting so compressor cooling does not stall recovery.
- Compressor runs near 49 dBA; avoid mounting JETGLAS RE2HP50*-1NCTT directly beside quiet bedrooms.
- Requires condensate drain routing and 240V electrical capacity; verify state DOE HEAR status.
Which Option Fits Your Situation?
Common Homeowner Questions for JETGLAS RE2HP50*-1NCTT
Direct answers to common technical, regulatory, and sizing questions sourced from primary U.S. government and OEM documentation.
How does JETGLAS RE2HP50*-1NCTT score under 10 CFR 430.32 May 2029 water heater minimums?
Federal 10 CFR 430.32 rules set the May 6, 2029 manufacturing baseline; JETGLAS RE2HP50*-1NCTT logs 3.89 UEF (Pass: +1.59 / +69.1%) within the 706-unit Hybrid/Electric Heat Pump group.
What physical clearance dimensions apply when installing JETGLAS RE2HP50*-1NCTT?
With a 46.1 in. height and 18 in. diameter, JETGLAS RE2HP50*-1NCTT fits spaces matching: fits standard 72 in. basement/garage clearance; clears 28 in. utility doorway (18" d), plus 6–12 in. above for plumbing shutoffs.
What 240V circuit or IFGC fuel line capacity fits JETGLAS RE2HP50*-1NCTT?
Powered via 240V at 19A max, JETGLAS RE2HP50*-1NCTT requires: Requires 240V dedicated branch circuit; check panel capacity. Confirm double-pole breaker sizing and condensate pump outlet proximity.
How do state electricity prices change annual costs for JETGLAS RE2HP50*-1NCTT?
Annual electric spend for JETGLAS RE2HP50*-1NCTT (835 kWh/yr) averages $152/yr nationwide (ranging from $122/yr in Washington hydro tiers up to $394/yr in Hawaii), calculated directly from August 2026 EIA Table 5.6.A tariffs.
What homeowner setups should avoid choosing JETGLAS RE2HP50*-1NCTT?
Homes lacking a condensate drain or 240V branch circuit—or unconditioned sub-zero spaces—should verify hybrid backup mode limits on JETGLAS RE2HP50*-1NCTT.
Is JETGLAS RE2HP50*-1NCTT sized adequately for a 2-to-4-person household?
ENERGY STAR certifies JETGLAS RE2HP50*-1NCTT at 65 gal First Hour Rating (-7 gal vs. 72 gal median); match that hourly reserve against simultaneous 2.0 GPM showerheads.
Does JETGLAS have active CPSC SaferProducts notices affecting RE2HP50*-1NCTT?
Zero CPSC recall alerts matched JETGLAS (2026-11-23 check). Keep your JETGLAS RE2HP50*-1NCTT serial code handy to track standard 6-to-12-year OEM warranty coverage.
Which competing water heater matches JETGLAS RE2HP50*-1NCTT (3.89 UEF) most closely?
State-run DOE HEAR programs (<=150% AMI, up to $1,750 for HPWH) and electric utilities lead 2026 incentives for JETGLAS RE2HP50*-1NCTT. Closest peer in Hybrid/Electric Heat Pump is Bradford White RE2HP50**-1NCTT (3.89 UEF).
Sources
- ENERGY STAR Certified Water Heaters Dataset (Socrata pbpq-swnu) — U.S. EPA & DOE ENERGY STAR, 2026 Live Certified Registry (retrieved 2026-11-23)
- 10 CFR 430.32 — Energy and Water Conservation Standards (Water Heaters & Plumbing Fixtures) — U.S. Department of Energy / eCFR, 2026 eCFR (incl. May 6, 2029 Rule) (retrieved 2026-11-23)
- CPSC SaferProducts.gov Product Recalls REST API — U.S. Consumer Product Safety Commission, 2026 Live Recalls Feed (retrieved 2026-11-23)
- EIA Electric Power Monthly Table 5.6.A — Average Residential Electricity Price by State — U.S. Energy Information Administration (EIA), August 2026 Monthly Release (retrieved 2026-11-23)