Kepler AZMCHW-50VN3A Water Heater Specifications (3.75 UEF)
The Kepler AZMCHW-50VN3A (Hybrid/Electric Heat Pump, Electric) achieves a certified 3.75 UEF rating across its 47-gallon nominal tank, 69 gal First Hour Rating, ranking #297 of 706 among 706 ENERGY STAR Hybrid/Electric Heat Pump models (PD 3629615). Under the May 6, 2029 DOE 10 CFR 430.32(d)(2) standard, compliance status is Pass: +1.45 / +63.0%. Rated annual electricity draw of 855 kWh/yr equates to roughly $155/yr ($1,553 over 10 years) at 18.16 cents/kWh. Closest certified alternative is 1HVAC ACIQ-50G-HP-WH (3.75 UEF).
- Uniform Energy Factor
- 3.75 UEF
- Cohort UEF Rank
- #297 of 706
- First Hour Rating
- 69 gal
- Storage Volume
- 47 gal
- Fuel / Type
- Electric / Hybrid/Electric Heat Pump
- DOE 2029 Rule Status
- Pass: +1.45 / +63.0%

Kepler AZMCHW-50VN3A (3.75 UEF) ranks #297 of 706 Hybrid/Electric Heat Pump models — 48-way tie; more efficient than 51.3% of Hybrid/Electric Heat Pump models, +0.05 UEF above the 3.70 UEF median.
Federal 2029 margin for Kepler AZMCHW-50VN3A: +1.45 UEF (+63.0%) vs. 10 CFR 430.32(d)(2) Electric >35 to <=55 gal (2.30 UEF). At EIA August 2026 national rates (18.16 cents/kWh), 855 kWh/yr for Kepler AZMCHW-50VN3A runs ~$155/yr vs. ~$633/yr for a 0.92 UEF electric tank. Acoustic output is 49 dBA (quieter than 12.8% of Hybrid/Electric Heat Pump models).
State electric sensitivity for Kepler AZMCHW-50VN3A: 10-year operating spend spans $1,251 in Washington (Lowest Hydro Tier) (14.63 cents/kWh) to $4,034 in Hawaii (Highest EIA State) (47.18 cents/kWh).
Peer comparison: Kepler AZMCHW-50VN3A (3.75 UEF) compares closely with 1HVAC ACIQ-50G-HP-WH (3.75 UEF, at parity) and ACIQ ACIQ-50G-HP-WH (3.75 UEF, at parity).
How Do Kepler AZMCHW-50VN3A Specs Compare to Hybrid/Electric Heat Pump Medians?
Kepler AZMCHW-50VN3A places #297 of 706 across 706 certified Hybrid/Electric Heat Pump configurations, with physical dimensions, draw profile, and thermal metrics benchmarked below.
| Specification Attribute | Certified Value | Cohort Benchmark / Delta | Provenance |
|---|---|---|---|
| Manufacturer / Brand | Kepler | 6 certified listings | ENERGY STAR PD 3629615 |
| Model Number | AZMCHW-50VN3A | Draw pattern: Medium-Usage | AZMCHW-50VN3A |
| Uniform Energy Factor (UEF) | 3.75 | +0.05 UEF vs. 3.70 UEF median | 10 CFR 430 Test Method |
| First Hour Rating (FHR) | 69 gal | -3 gal vs. 72 gal median | 10 CFR 430 Recovery Test |
| Rated Annual Electricity Use | 855 kWh/yr | -217 kWh/yr vs. 1,072 kWh/yr median | Est. $155/yr @ $0.1816/kWh (EIA US Avg) |
| Thermal Recovery Efficiency | 430% | +1.0 pts vs. 429.0% median | ENERGY STAR Dataset |
| Physical Envelope (H x Dia) | 47.9" H x 18.3" D | Fits standard 72 in. basement/garage clearance; clears 28 in. utility doorway (18.3" D) | Doorway & ceiling check |
| Electrical Circuit Requirements | 240 V / 24 A max | Requires 240V dedicated branch circuit; check panel capacity | NEC / Branch circuit check |
| Heat Pump Refrigerant & GWP | R-134a (GWP:1430) | Check regional AIM Act phase-down transition | EPA AIM Act Compliance |
| Sound Pressure Level | 49 dBA | quieter than 12.8% of Hybrid/Electric Heat Pump models · At 49 dBA median | Indoor placement check |
| Certification Date | 2024-11-11 | Certified 2024-11-11 | Markets: United States, Canada |
What Does AZMCHW-50VN3A Cost to Operate Across State Electricity Rates?
At 855 kWh/yr, Kepler AZMCHW-50VN3A runs roughly $155/yr on the EIA national average tier under August 2026 Table 5.6.A rates.
| Jurisdiction (EIA Aug 2026) | Residential Rate | Annual Cost | 10-Yr Operating Spend | 10-Yr Savings vs. 0.92 UEF |
|---|---|---|---|---|
| United States Average | 18.16 ¢/kWh ($0.1816) | $155/yr | $1,553 | $4,776 |
| Hawaii (Highest EIA State) | 47.18 ¢/kWh ($0.4718) | $403/yr | $4,034 | $12,408 |
| California | 29.75 ¢/kWh ($0.2975) | $254/yr | $2,544 | $7,824 |
| Texas | 15.91 ¢/kWh ($0.1591) | $136/yr | $1,360 | $4,184 |
| Washington (Lowest Hydro Tier) | 14.63 ¢/kWh ($0.1463) | $125/yr | $1,251 | $3,848 |
Are There Active CPSC Safety Recalls for Kepler Water Heaters?
Zero active CPSC recalls matched Kepler in our 2026-11-23 SaferProducts sweep; verify your individual tank date code via our lookup tool. See Serial Number Lookup.
Which Certified Water Heaters Match AZMCHW-50VN3A Most Closely?
These 5 competing Hybrid/Electric Heat Pump units sit nearest to Kepler AZMCHW-50VN3A by storage capacity and 3.75 UEF rating.
| Brand & Model | Type | Vol | FHR | UEF (Δ) | kWh/yr |
|---|---|---|---|---|---|
| 1HVAC ACIQ-50G-HP-WH | Hybrid/Electric Heat Pump | 47 gal | 69 gal | 3.75 (at parity) | 855 |
| ACIQ ACIQ-50G-HP-WH | Hybrid/Electric Heat Pump | 47 gal | 69 gal | 3.75 (at parity) | 855 |
| Bosch TR7000T - 50CA | Hybrid/Electric Heat Pump | 47 gal | 69 gal | 3.75 (at parity) | 855 |
| Custom Comfort CCOHPWH50A | Hybrid/Electric Heat Pump | 47 gal | 69 gal | 3.75 (at parity) | 855 |
| Bosch TR7000T - 50US | Hybrid/Electric Heat Pump | 47 gal | 69 gal | 3.75 (at parity) | 855 |
What Installation Caveats Apply Before Buying Kepler AZMCHW-50VN3A?
Even high-UEF units like Kepler AZMCHW-50VN3A (3.75 UEF) carry physical space, condensate, and fuel-line prerequisites noted below.
Key Limitations & Exclusions
- Kepler AZMCHW-50VN3A needs >=450 cu ft room air volume or ducting so compressor cooling does not stall recovery.
- Compressor runs near 49 dBA; avoid mounting Kepler AZMCHW-50VN3A directly beside quiet bedrooms.
- Requires condensate drain routing and 240V electrical capacity; verify state DOE HEAR status.
Which Option Fits Your Situation?
What Are the Key Questions About Kepler AZMCHW-50VN3A?
Direct answers to common technical, regulatory, and sizing questions sourced from primary U.S. government and OEM documentation.
Is Kepler AZMCHW-50VN3A eligible for continued manufacture past May 6, 2029?
At 3.75 UEF, Kepler AZMCHW-50VN3A achieves Pass: +1.45 / +63.0% for the 2029 DOE standard and stands #297 of 706 against 1HVAC ACIQ-50G-HP-WH and ACIQ ACIQ-50G-HP-WH.
How tall and wide is Kepler AZMCHW-50VN3A, and what service clearance is needed?
Physical dimensions for Kepler AZMCHW-50VN3A are 47.9 in. height and 18.3 in. diameter (fits standard 72 in. basement/garage clearance; clears 28 in. utility doorway (18.3" d)); verify stair turns and drain pan width before delivery.
Will Kepler AZMCHW-50VN3A require upgrading household electrical panels or gas piping?
Kepler AZMCHW-50VN3A draws 240V at 24A max (Requires 240V dedicated branch circuit; check panel capacity); check whether existing 10/2 AWG 30A copper wiring aligns with nameplate amps.
Is Kepler AZMCHW-50VN3A economical to operate at 18.16 cents/kWh US electric rates?
Expect roughly $155/yr ($1,550 over 10 years) to power Kepler AZMCHW-50VN3A at 855 kWh/yr under the 18.16 cents/kWh US average (ranging from $125/yr in Washington hydro tiers up to $403/yr in Hawaii).
Which installation bottlenecks limit Kepler AZMCHW-50VN3A?
If ambient room air stays below 40 °F year-round or closet volume falls under 450 cu ft, Kepler AZMCHW-50VN3A drops into resistance mode more often.
How does Kepler AZMCHW-50VN3A handle simultaneous showers and laundry?
Delivering 69 gal in the first hour (-3 gal vs. 72 gal median), Kepler AZMCHW-50VN3A combines 47 gal tank storage with rapid burner/element recovery.
How long is the warranty on Kepler AZMCHW-50VN3A and how do you decode its serial?
CPSC records show 0 active plumbing recalls for Kepler as of 2026-11-23. Confirm install proof and serial manufacture year on Kepler AZMCHW-50VN3A before calling service.
How do 2026 post-OBBBA rebates affect buying Kepler AZMCHW-50VN3A?
Check state energy office HEAR portals and utility rebates in 2026 since federal 25C ended Dec 31, 2025. Closest peer in Hybrid/Electric Heat Pump is 1HVAC ACIQ-50G-HP-WH (3.75 UEF).
Sources
- ENERGY STAR Certified Water Heaters Dataset (Socrata pbpq-swnu) — U.S. EPA & DOE ENERGY STAR, 2026 Live Certified Registry (retrieved 2026-11-23)
- 10 CFR 430.32 — Energy and Water Conservation Standards (Water Heaters & Plumbing Fixtures) — U.S. Department of Energy / eCFR, 2026 eCFR (incl. May 6, 2029 Rule) (retrieved 2026-11-23)
- CPSC SaferProducts.gov Product Recalls REST API — U.S. Consumer Product Safety Commission, 2026 Live Recalls Feed (retrieved 2026-11-23)
- EIA Electric Power Monthly Table 5.6.A — Average Residential Electricity Price by State — U.S. Energy Information Administration (EIA), August 2026 Monthly Release (retrieved 2026-11-23)