Skip to main content
ENERGY STAR water heater model · PD 4570023

Lennox WHHP050T45MD240S**** Water Heater Specifications (3.83 UEF)

With PD 4570023 certification, Lennox WHHP050T45MD240S**** (Hybrid/Electric Heat Pump, Electric) achieves a certified 3.83 UEF rating across its 45-gallon nominal tank, 69 gal First Hour Rating, standing #230 of 706 across 706 peers with Pass: +1.53 / +66.5% for May 6, 2029. Rated annual electricity draw of 848 kWh/yr equates to roughly $154/yr ($1,540 over 10 years) at 18.16 cents/kWh. Closest certified alternative is Ariston ARIHPWH-50-T (3.83 UEF).

Uniform Energy Factor
3.83 UEF
Cohort UEF Rank
#230 of 706 (top 37.8%)
First Hour Rating
69 gal
Storage Volume
45 gal
Fuel / Type
Electric / Hybrid/Electric Heat Pump
DOE 2029 Rule Status
Pass: +1.53 / +66.5%
Hybrid heat pump water heater upper shroud with brass relief valve and insulated copper risers
Hybrid heat pump water heater upper shroud with brass relief valve and insulated copper risers
Hybrid/Electric Heat Pump UEF Efficiency Distribution (706 Certified Units)Distribution of certified UEF ratings across 706 units in Hybrid/Electric Heat Pump, marking Lennox WHHP050T45MD240S**** at 3.83 UEF.21130201631342031241542.52 UEF4.50 UEFMedian 3.702029 min 2.30Lennox WHHP050T45MD240S****: 3.83
Hybrid/Electric Heat Pump UEF Efficiency Distribution (706 Certified Units). Highlighted pin shows Lennox WHHP050T45MD240S**** relative to the cohort median.
Efficiency comparison & rule summary

ENERGY STAR certification places Lennox WHHP050T45MD240S**** at 3.83 UEF (#230 of 706; +0.13 UEF vs. 3.70 UEF median) in Hybrid/Electric Heat Pump.

May 6, 2029 readiness: Lennox WHHP050T45MD240S**** stands +1.53 UEF (+66.5%) relative to 10 CFR 430.32(d)(2) Electric >35 to <=55 gal (2.30 UEF). At EIA August 2026 national rates (18.16 cents/kWh), 848 kWh/yr for Lennox WHHP050T45MD240S**** runs ~$154/yr vs. ~$641/yr for a 0.92 UEF electric tank.

State electric sensitivity for Lennox WHHP050T45MD240S****: 10-year operating spend spans $1,241 in Washington (Lowest Hydro Tier) (14.63 cents/kWh) to $4,001 in Hawaii (Highest EIA State) (47.18 cents/kWh).

In the Hybrid/Electric Heat Pump tier, Ariston ARIHPWH-50-T (3.83 UEF, at parity) and Noritz NHP-50-240 (3.85 UEF, delta +0.02) bracket Lennox WHHP050T45MD240S****.

How Complete Are the Certified Metrics for Lennox WHHP050T45MD240S****?

Standing at #230 of 706 (top 37.8%) among 706 certified Hybrid/Electric Heat Pump heaters, Lennox WHHP050T45MD240S**** brings measurable deltas in recovery, footprint, and energy efficiency.

Certified model attributes compared against 706 ENERGY STAR Hybrid/Electric Heat Pump peers
Specification AttributeCertified ValueCohort Benchmark / DeltaProvenance
Manufacturer / BrandLennox4 certified listingsENERGY STAR PD 4570023
Model NumberWHHP050T45MD240S****Draw pattern: Medium-UsageWHHP050T45MD240S****
Uniform Energy Factor (UEF)3.83+0.13 UEF vs. 3.70 UEF median10 CFR 430 Test Method
First Hour Rating (FHR)69 gal-3 gal vs. 72 gal median10 CFR 430 Recovery Test
Rated Annual Electricity Use848 kWh/yr-224 kWh/yr vs. 1,072 kWh/yr medianEst. $154/yr @ $0.1816/kWh (EIA US Avg)
Thermal Recovery Efficiency437%+8.0 pts vs. 429.0% medianENERGY STAR Dataset
Physical Envelope (H x Dia)45.8" H x 18.2" DFits standard 72 in. basement/garage clearance; clears 28 in. utility doorway (18.2" D)Doorway & ceiling check
Electrical Circuit Requirements240 V / 21 A maxRequires 240V dedicated branch circuit; check panel capacityNEC / Branch circuit check
Heat Pump Refrigerant & GWPR-513A (GWP:630)Lower-GWP refrigerant alignment (EPA AIM Act)EPA AIM Act Compliance
Certification Date2026-02-25Certified 2026-02-25Markets: United States, Canada

What Is the Projected Utility Bill for WHHP050T45MD240S**** by State?

At 848 kWh/yr, Lennox WHHP050T45MD240S**** averages about $154/yr across US households—see 10-year payback spreads versus 0.92 UEF resistance tanks.

Estimated Annual Electricity Cost by State Rate (848 kWh/yr)Projected annual electricity spend across five benchmark EIA August 2026 residential electric tiers.United States Average$154.00/yrHawaii$400.00/yrCalifornia$252.00/yrTexas$135.00/yrWashington$124.00/yr
Projected annual electricity spend across five benchmark EIA August 2026 residential electric tiers.
Estimated electricity cost and 10-year spend across benchmark states
Jurisdiction (EIA Aug 2026)Residential RateAnnual Cost10-Yr Operating Spend10-Yr Savings vs. 0.92 UEF
United States Average 18.16 ¢/kWh ($0.1816) $154/yr $1,540 $4,871
Hawaii (Highest EIA State) 47.18 ¢/kWh ($0.4718) $400/yr $4,001 $12,654
California 29.75 ¢/kWh ($0.2975) $252/yr $2,523 $7,979
Texas 15.91 ¢/kWh ($0.1591) $135/yr $1,349 $4,267
Washington (Lowest Hydro Tier) 14.63 ¢/kWh ($0.1463) $124/yr $1,241 $3,924
Estimated electricity spend (848 kWh/yr)

Condensing Gas Tankless vs. Storage Tank Flow Path & Gas Supply Engineering schematic contrasting 199,000 BTU/h condensing tankless piping (3/4 in. gas supply, Category IV PVC vent, condensate drain) against a 40,000 BTU/h atmospheric tank. Condensing Gas Tankless (0.91–0.96 UEF) Secondary HX Cat IV PVC Vent Cold In Hot Out 3/4"–1" Gas 199K BTU/h Condensate Atmospheric Storage Tank (0.58–0.65 UEF) Type B Flue Anode Rod 40K BTU/h 1/2" Gas Up to 100 ft T&P 150 psi 50–85 gal FHR Reserve | 8–12 yr life
Technical comparison: condensing gas tankless units require 3/4 in.–1 in. IFGC Table 402.4 gas supply and Category IV condensate drainage, while atmospheric tanks run on 1/2 in. lines.

Are Lennox Models Affected by Current CPSC Notices?

Zero brand-level CPSC hazard notices matched Lennox in our 2026-11-23 feed; decode your water heater's serial number below to confirm warranty status. See Serial Number Lookup.

Which 5 Models Offer Similar Output to WHHP050T45MD240S****?

Ordered by minimal capacity and UEF spread relative to Lennox WHHP050T45MD240S****, these five certified peers give direct replacement benchmarks.

5 closest certified peers matched by equipment class, storage volume, and efficiency rating
Brand & ModelTypeVolFHRUEF (Δ)kWh/yr
Ariston ARIHPWH-50-T Hybrid/Electric Heat Pump 45 gal 69 gal 3.83 (at parity) 848
Noritz NHP-50-240 Hybrid/Electric Heat Pump 45 gal 68 gal 3.85 (+0.02) 844
Friedrich PROH50 T2 FD400-30 Hybrid/Electric Heat Pump 45 gal 67 gal 3.88 (+0.05) 846
Rheem CPROPH50 T2 RH375-SO Hybrid/Electric Heat Pump 45 gal 67 gal 3.88 (+0.05) 846
Friedrich PROH50 T2 FD400-SO Hybrid/Electric Heat Pump 45 gal 67 gal 3.88 (+0.05) 846

Which Home Setups Are NOT a Fit for Lennox WHHP050T45MD240S****?

Comparing Lennox WHHP050T45MD240S**** against Ariston ARIHPWH-50-T requires checking closet airflow, IFGC gas or 240V electrical sizing, and May 6, 2029 compliance.

Key Limitations & Exclusions

  • Lennox WHHP050T45MD240S**** needs >=450 cu ft room air volume or ducting so compressor cooling does not stall recovery.
  • Compressor runs near 49 dBA; avoid mounting Lennox WHHP050T45MD240S**** directly beside quiet bedrooms.
  • Requires condensate drain routing and 240V electrical capacity; verify state DOE HEAR status.

Which Option Fits Your Situation?

High Electric Rate States Choosing Lennox WHHP050T45MD240S**** Strong Fit — 3.83 UEF trims electric use ~75% vs 0.92 UEF tanks.
Open Basement or Garage (>=450 cu ft) Strong Fit — Ample ambient air sustains heat-pump-only efficiency.
Small Interior Closet (<300 cu ft) Caution — Add duct kit or compare Ariston ARIHPWH-50-T footprint.

Practical Specs & Code Questions for Lennox WHHP050T45MD240S****

Direct answers to common technical, regulatory, and sizing questions sourced from primary U.S. government and OEM documentation.

How does Lennox WHHP050T45MD240S**** score under 10 CFR 430.32 May 2029 water heater minimums?

Federal 10 CFR 430.32 rules set the May 6, 2029 manufacturing baseline; Lennox WHHP050T45MD240S**** logs 3.83 UEF (Pass: +1.53 / +66.5%) within the 706-unit Hybrid/Electric Heat Pump group.

What physical clearance dimensions apply when installing Lennox WHHP050T45MD240S****?

With a 45.8 in. height and 18.2 in. diameter, Lennox WHHP050T45MD240S**** fits spaces matching: fits standard 72 in. basement/garage clearance; clears 28 in. utility doorway (18.2" d), plus 6–12 in. above for plumbing shutoffs.

What 240V circuit or IFGC fuel line capacity fits Lennox WHHP050T45MD240S****?

Powered via 240V at 21A max, Lennox WHHP050T45MD240S**** requires: Requires 240V dedicated branch circuit; check panel capacity. Confirm double-pole breaker sizing and condensate pump outlet proximity.

How do state electricity prices change annual costs for Lennox WHHP050T45MD240S****?

Annual electric spend for Lennox WHHP050T45MD240S**** (848 kWh/yr) averages $154/yr nationwide (ranging from $124/yr in Washington hydro tiers up to $400/yr in Hawaii), calculated directly from August 2026 EIA Table 5.6.A tariffs.

What homeowner setups should avoid choosing Lennox WHHP050T45MD240S****?

Homes lacking a condensate drain or 240V branch circuit—or unconditioned sub-zero spaces—should verify hybrid backup mode limits on Lennox WHHP050T45MD240S****.

Is Lennox WHHP050T45MD240S**** sized adequately for a 2-to-4-person household?

ENERGY STAR certifies Lennox WHHP050T45MD240S**** at 69 gal First Hour Rating (-3 gal vs. 72 gal median); match that hourly reserve against simultaneous 2.0 GPM showerheads.

Does Lennox have active CPSC SaferProducts notices affecting WHHP050T45MD240S****?

Zero CPSC recall alerts matched Lennox (2026-11-23 check). Keep your Lennox WHHP050T45MD240S**** serial code handy to track standard 6-to-12-year OEM warranty coverage.

Which competing water heater matches Lennox WHHP050T45MD240S**** (3.83 UEF) most closely?

State-run DOE HEAR programs (<=150% AMI, up to $1,750 for HPWH) and electric utilities lead 2026 incentives for Lennox WHHP050T45MD240S****. Closest peer in Hybrid/Electric Heat Pump is Ariston ARIHPWH-50-T (3.83 UEF).

Sources

  1. ENERGY STAR Certified Water Heaters Dataset (Socrata pbpq-swnu) — U.S. EPA & DOE ENERGY STAR, 2026 Live Certified Registry (retrieved 2026-11-23)
  2. 10 CFR 430.32 — Energy and Water Conservation Standards (Water Heaters & Plumbing Fixtures) — U.S. Department of Energy / eCFR, 2026 eCFR (incl. May 6, 2029 Rule) (retrieved 2026-11-23)
  3. CPSC SaferProducts.gov Product Recalls REST API — U.S. Consumer Product Safety Commission, 2026 Live Recalls Feed (retrieved 2026-11-23)
  4. EIA Electric Power Monthly Table 5.6.A — Average Residential Electricity Price by State — U.S. Energy Information Administration (EIA), August 2026 Monthly Release (retrieved 2026-11-23)

Related U.S. Metro Plumbing Benchmarks