Lennox WHHP050T45MD240S**** Water Heater Specifications (3.83 UEF)
With PD 4570023 certification, Lennox WHHP050T45MD240S**** (Hybrid/Electric Heat Pump, Electric) achieves a certified 3.83 UEF rating across its 45-gallon nominal tank, 69 gal First Hour Rating, standing #230 of 706 across 706 peers with Pass: +1.53 / +66.5% for May 6, 2029. Rated annual electricity draw of 848 kWh/yr equates to roughly $154/yr ($1,540 over 10 years) at 18.16 cents/kWh. Closest certified alternative is Ariston ARIHPWH-50-T (3.83 UEF).
- Uniform Energy Factor
- 3.83 UEF
- Cohort UEF Rank
- #230 of 706 (top 37.8%)
- First Hour Rating
- 69 gal
- Storage Volume
- 45 gal
- Fuel / Type
- Electric / Hybrid/Electric Heat Pump
- DOE 2029 Rule Status
- Pass: +1.53 / +66.5%

ENERGY STAR certification places Lennox WHHP050T45MD240S**** at 3.83 UEF (#230 of 706; +0.13 UEF vs. 3.70 UEF median) in Hybrid/Electric Heat Pump.
May 6, 2029 readiness: Lennox WHHP050T45MD240S**** stands +1.53 UEF (+66.5%) relative to 10 CFR 430.32(d)(2) Electric >35 to <=55 gal (2.30 UEF). At EIA August 2026 national rates (18.16 cents/kWh), 848 kWh/yr for Lennox WHHP050T45MD240S**** runs ~$154/yr vs. ~$641/yr for a 0.92 UEF electric tank.
State electric sensitivity for Lennox WHHP050T45MD240S****: 10-year operating spend spans $1,241 in Washington (Lowest Hydro Tier) (14.63 cents/kWh) to $4,001 in Hawaii (Highest EIA State) (47.18 cents/kWh).
In the Hybrid/Electric Heat Pump tier, Ariston ARIHPWH-50-T (3.83 UEF, at parity) and Noritz NHP-50-240 (3.85 UEF, delta +0.02) bracket Lennox WHHP050T45MD240S****.
How Complete Are the Certified Metrics for Lennox WHHP050T45MD240S****?
Standing at #230 of 706 (top 37.8%) among 706 certified Hybrid/Electric Heat Pump heaters, Lennox WHHP050T45MD240S**** brings measurable deltas in recovery, footprint, and energy efficiency.
| Specification Attribute | Certified Value | Cohort Benchmark / Delta | Provenance |
|---|---|---|---|
| Manufacturer / Brand | Lennox | 4 certified listings | ENERGY STAR PD 4570023 |
| Model Number | WHHP050T45MD240S**** | Draw pattern: Medium-Usage | WHHP050T45MD240S**** |
| Uniform Energy Factor (UEF) | 3.83 | +0.13 UEF vs. 3.70 UEF median | 10 CFR 430 Test Method |
| First Hour Rating (FHR) | 69 gal | -3 gal vs. 72 gal median | 10 CFR 430 Recovery Test |
| Rated Annual Electricity Use | 848 kWh/yr | -224 kWh/yr vs. 1,072 kWh/yr median | Est. $154/yr @ $0.1816/kWh (EIA US Avg) |
| Thermal Recovery Efficiency | 437% | +8.0 pts vs. 429.0% median | ENERGY STAR Dataset |
| Physical Envelope (H x Dia) | 45.8" H x 18.2" D | Fits standard 72 in. basement/garage clearance; clears 28 in. utility doorway (18.2" D) | Doorway & ceiling check |
| Electrical Circuit Requirements | 240 V / 21 A max | Requires 240V dedicated branch circuit; check panel capacity | NEC / Branch circuit check |
| Heat Pump Refrigerant & GWP | R-513A (GWP:630) | Lower-GWP refrigerant alignment (EPA AIM Act) | EPA AIM Act Compliance |
| Certification Date | 2026-02-25 | Certified 2026-02-25 | Markets: United States, Canada |
What Is the Projected Utility Bill for WHHP050T45MD240S**** by State?
At 848 kWh/yr, Lennox WHHP050T45MD240S**** averages about $154/yr across US households—see 10-year payback spreads versus 0.92 UEF resistance tanks.
| Jurisdiction (EIA Aug 2026) | Residential Rate | Annual Cost | 10-Yr Operating Spend | 10-Yr Savings vs. 0.92 UEF |
|---|---|---|---|---|
| United States Average | 18.16 ¢/kWh ($0.1816) | $154/yr | $1,540 | $4,871 |
| Hawaii (Highest EIA State) | 47.18 ¢/kWh ($0.4718) | $400/yr | $4,001 | $12,654 |
| California | 29.75 ¢/kWh ($0.2975) | $252/yr | $2,523 | $7,979 |
| Texas | 15.91 ¢/kWh ($0.1591) | $135/yr | $1,349 | $4,267 |
| Washington (Lowest Hydro Tier) | 14.63 ¢/kWh ($0.1463) | $124/yr | $1,241 | $3,924 |
Are Lennox Models Affected by Current CPSC Notices?
Zero brand-level CPSC hazard notices matched Lennox in our 2026-11-23 feed; decode your water heater's serial number below to confirm warranty status. See Serial Number Lookup.
Which 5 Models Offer Similar Output to WHHP050T45MD240S****?
Ordered by minimal capacity and UEF spread relative to Lennox WHHP050T45MD240S****, these five certified peers give direct replacement benchmarks.
| Brand & Model | Type | Vol | FHR | UEF (Δ) | kWh/yr |
|---|---|---|---|---|---|
| Ariston ARIHPWH-50-T | Hybrid/Electric Heat Pump | 45 gal | 69 gal | 3.83 (at parity) | 848 |
| Noritz NHP-50-240 | Hybrid/Electric Heat Pump | 45 gal | 68 gal | 3.85 (+0.02) | 844 |
| Friedrich PROH50 T2 FD400-30 | Hybrid/Electric Heat Pump | 45 gal | 67 gal | 3.88 (+0.05) | 846 |
| Rheem CPROPH50 T2 RH375-SO | Hybrid/Electric Heat Pump | 45 gal | 67 gal | 3.88 (+0.05) | 846 |
| Friedrich PROH50 T2 FD400-SO | Hybrid/Electric Heat Pump | 45 gal | 67 gal | 3.88 (+0.05) | 846 |
Which Home Setups Are NOT a Fit for Lennox WHHP050T45MD240S****?
Comparing Lennox WHHP050T45MD240S**** against Ariston ARIHPWH-50-T requires checking closet airflow, IFGC gas or 240V electrical sizing, and May 6, 2029 compliance.
Key Limitations & Exclusions
- Lennox WHHP050T45MD240S**** needs >=450 cu ft room air volume or ducting so compressor cooling does not stall recovery.
- Compressor runs near 49 dBA; avoid mounting Lennox WHHP050T45MD240S**** directly beside quiet bedrooms.
- Requires condensate drain routing and 240V electrical capacity; verify state DOE HEAR status.
Which Option Fits Your Situation?
Practical Specs & Code Questions for Lennox WHHP050T45MD240S****
Direct answers to common technical, regulatory, and sizing questions sourced from primary U.S. government and OEM documentation.
How does Lennox WHHP050T45MD240S**** score under 10 CFR 430.32 May 2029 water heater minimums?
Federal 10 CFR 430.32 rules set the May 6, 2029 manufacturing baseline; Lennox WHHP050T45MD240S**** logs 3.83 UEF (Pass: +1.53 / +66.5%) within the 706-unit Hybrid/Electric Heat Pump group.
What physical clearance dimensions apply when installing Lennox WHHP050T45MD240S****?
With a 45.8 in. height and 18.2 in. diameter, Lennox WHHP050T45MD240S**** fits spaces matching: fits standard 72 in. basement/garage clearance; clears 28 in. utility doorway (18.2" d), plus 6–12 in. above for plumbing shutoffs.
What 240V circuit or IFGC fuel line capacity fits Lennox WHHP050T45MD240S****?
Powered via 240V at 21A max, Lennox WHHP050T45MD240S**** requires: Requires 240V dedicated branch circuit; check panel capacity. Confirm double-pole breaker sizing and condensate pump outlet proximity.
How do state electricity prices change annual costs for Lennox WHHP050T45MD240S****?
Annual electric spend for Lennox WHHP050T45MD240S**** (848 kWh/yr) averages $154/yr nationwide (ranging from $124/yr in Washington hydro tiers up to $400/yr in Hawaii), calculated directly from August 2026 EIA Table 5.6.A tariffs.
What homeowner setups should avoid choosing Lennox WHHP050T45MD240S****?
Homes lacking a condensate drain or 240V branch circuit—or unconditioned sub-zero spaces—should verify hybrid backup mode limits on Lennox WHHP050T45MD240S****.
Is Lennox WHHP050T45MD240S**** sized adequately for a 2-to-4-person household?
ENERGY STAR certifies Lennox WHHP050T45MD240S**** at 69 gal First Hour Rating (-3 gal vs. 72 gal median); match that hourly reserve against simultaneous 2.0 GPM showerheads.
Does Lennox have active CPSC SaferProducts notices affecting WHHP050T45MD240S****?
Zero CPSC recall alerts matched Lennox (2026-11-23 check). Keep your Lennox WHHP050T45MD240S**** serial code handy to track standard 6-to-12-year OEM warranty coverage.
Which competing water heater matches Lennox WHHP050T45MD240S**** (3.83 UEF) most closely?
State-run DOE HEAR programs (<=150% AMI, up to $1,750 for HPWH) and electric utilities lead 2026 incentives for Lennox WHHP050T45MD240S****. Closest peer in Hybrid/Electric Heat Pump is Ariston ARIHPWH-50-T (3.83 UEF).
Sources
- ENERGY STAR Certified Water Heaters Dataset (Socrata pbpq-swnu) — U.S. EPA & DOE ENERGY STAR, 2026 Live Certified Registry (retrieved 2026-11-23)
- 10 CFR 430.32 — Energy and Water Conservation Standards (Water Heaters & Plumbing Fixtures) — U.S. Department of Energy / eCFR, 2026 eCFR (incl. May 6, 2029 Rule) (retrieved 2026-11-23)
- CPSC SaferProducts.gov Product Recalls REST API — U.S. Consumer Product Safety Commission, 2026 Live Recalls Feed (retrieved 2026-11-23)
- EIA Electric Power Monthly Table 5.6.A — Average Residential Electricity Price by State — U.S. Energy Information Administration (EIA), August 2026 Monthly Release (retrieved 2026-11-23)