Skip to main content
ENERGY STAR water heater model · PD 4724095

Noritz NHP-50-240 Water Heater Specifications (3.85 UEF)

The Noritz NHP-50-240 (Hybrid/Electric Heat Pump, Electric) achieves a certified 3.85 UEF rating across its 45-gallon nominal tank, 68 gal First Hour Rating, ranking #217 of 706 among 706 ENERGY STAR Hybrid/Electric Heat Pump models (PD 4724095). Under the May 6, 2029 DOE 10 CFR 430.32(d)(2) standard, compliance status is Pass: +1.55 / +67.4%. Rated annual electricity draw of 844 kWh/yr equates to roughly $153/yr ($1,533 over 10 years) at 18.16 cents/kWh. Closest certified alternative is Ariston ARIHPWH-50-T (3.83 UEF).

Uniform Energy Factor
3.85 UEF
Cohort UEF Rank
#217 of 706 (top 31.2%)
First Hour Rating
68 gal
Storage Volume
45 gal
Fuel / Type
Electric / Hybrid/Electric Heat Pump
DOE 2029 Rule Status
Pass: +1.55 / +67.4%
Hybrid heat pump water heater upper shroud with brass relief valve and insulated copper risers
Hybrid heat pump water heater upper shroud with brass relief valve and insulated copper risers
Hybrid/Electric Heat Pump UEF Efficiency Distribution (706 Certified Units)Distribution of certified UEF ratings across 706 units in Hybrid/Electric Heat Pump, marking Noritz NHP-50-240 at 3.85 UEF.21130201631342031241542.52 UEF4.50 UEFMedian 3.702029 min 2.30Noritz NHP-50-240: 3.85
Hybrid/Electric Heat Pump UEF Efficiency Distribution (706 Certified Units). Highlighted pin shows Noritz NHP-50-240 relative to the cohort median.
Efficiency comparison & rule summary

Noritz NHP-50-240 (3.85 UEF) ranks #217 of 706 Hybrid/Electric Heat Pump models — 4-way tie; top 31.2%, more efficient than 68.8% of Hybrid/Electric Heat Pump models, +0.15 UEF above the 3.70 UEF median.

Federal 2029 margin for Noritz NHP-50-240: +1.55 UEF (+67.4%) vs. 10 CFR 430.32(d)(2) Electric >35 to <=55 gal (2.30 UEF). At EIA August 2026 national rates (18.16 cents/kWh), 844 kWh/yr for Noritz NHP-50-240 runs ~$153/yr vs. ~$641/yr for a 0.92 UEF electric tank. Acoustic output is 48 dBA (quieter than 67.8% of Hybrid/Electric Heat Pump models).

State electric sensitivity for Noritz NHP-50-240: 10-year operating spend spans $1,235 in Washington (Lowest Hydro Tier) (14.63 cents/kWh) to $3,982 in Hawaii (Highest EIA State) (47.18 cents/kWh).

Peer comparison: Noritz NHP-50-240 (3.85 UEF) compares closely with Ariston ARIHPWH-50-T (3.83 UEF, delta -0.02) and Lennox WHHP050T45MD240S**** (3.83 UEF, delta -0.02).

What Physical and Thermal Ratings Define Noritz NHP-50-240?

Positioning at #217 of 706 (top 31.2%) out of 706 Hybrid/Electric Heat Pump peers, Noritz NHP-50-240 pairs measured UEF performance with specific clearance and wiring rules.

Certified model attributes compared against 706 ENERGY STAR Hybrid/Electric Heat Pump peers
Specification AttributeCertified ValueCohort Benchmark / DeltaProvenance
Manufacturer / BrandNoritz23 certified listingsENERGY STAR PD 4724095
Model NumberNHP-50-240Draw pattern: Medium-UsageNHP-50-240
Uniform Energy Factor (UEF)3.85+0.15 UEF vs. 3.70 UEF median10 CFR 430 Test Method
First Hour Rating (FHR)68 gal-4 gal vs. 72 gal median10 CFR 430 Recovery Test
Rated Annual Electricity Use844 kWh/yr-228 kWh/yr vs. 1,072 kWh/yr medianEst. $153/yr @ $0.1816/kWh (EIA US Avg)
Thermal Recovery Efficiency438%+9.0 pts vs. 429.0% medianENERGY STAR Dataset
Physical Envelope (H x Dia)61.4" H x 22" DFits standard 72 in. basement/garage clearance; clears 28 in. utility doorway (22" D)Doorway & ceiling check
Electrical Circuit Requirements240 V / 21.3 A maxRequires 240V dedicated branch circuit; check panel capacityNEC / Branch circuit check
Heat Pump Refrigerant & GWPR-134a (GWP:1430)Check regional AIM Act phase-down transitionEPA AIM Act Compliance
Sound Pressure Level48 dBAtop 32.2% · quieter than 67.8% of Hybrid/Electric Heat Pump models · -1 dBA vs. 49 dBA medianIndoor placement check
Certification Date2026-10-30Certified 2026-10-30Markets: United States, Canada

Why Do State Utility Rates Shift NHP-50-240 Running Costs?

Consuming 844 kWh annually puts Noritz NHP-50-240 near $153/yr at US baseline tariffs, with multi-state EIA comparisons charted below.

Estimated Annual Electricity Cost by State Rate (844 kWh/yr)Projected annual electricity spend across five benchmark EIA August 2026 residential electric tiers.United States Average$153.00/yrHawaii$398.00/yrCalifornia$251.00/yrTexas$134.00/yrWashington$123.00/yr
Projected annual electricity spend across five benchmark EIA August 2026 residential electric tiers.
Estimated electricity cost and 10-year spend across benchmark states
Jurisdiction (EIA Aug 2026)Residential RateAnnual Cost10-Yr Operating Spend10-Yr Savings vs. 0.92 UEF
United States Average 18.16 ¢/kWh ($0.1816) $153/yr $1,533 $4,881
Hawaii (Highest EIA State) 47.18 ¢/kWh ($0.4718) $398/yr $3,982 $12,682
California 29.75 ¢/kWh ($0.2975) $251/yr $2,511 $7,997
Texas 15.91 ¢/kWh ($0.1591) $134/yr $1,343 $4,277
Washington (Lowest Hydro Tier) 14.63 ¢/kWh ($0.1463) $123/yr $1,235 $3,933
Estimated electricity spend (844 kWh/yr)

Condensing Gas Tankless vs. Storage Tank Flow Path & Gas Supply Engineering schematic contrasting 199,000 BTU/h condensing tankless piping (3/4 in. gas supply, Category IV PVC vent, condensate drain) against a 40,000 BTU/h atmospheric tank. Condensing Gas Tankless (0.91–0.96 UEF) Secondary HX Cat IV PVC Vent Cold In Hot Out 3/4"–1" Gas 199K BTU/h Condensate Atmospheric Storage Tank (0.58–0.65 UEF) Type B Flue Anode Rod 40K BTU/h 1/2" Gas Up to 100 ft T&P 150 psi 50–85 gal FHR Reserve | 8–12 yr life
Technical comparison: condensing gas tankless units require 3/4 in.–1 in. IFGC Table 402.4 gas supply and Category IV condensate drainage, while atmospheric tanks run on 1/2 in. lines.

Have Any Noritz Series Triggered CPSC Recalls?

SaferProducts screening on 2026-11-23 returned zero recall matches for Noritz; confirm tank age separately using the rating-plate serial pattern. See Serial Number Lookup.

What Are 5 Direct Alternatives to Noritz NHP-50-240?

Homeowners cross-shopping Noritz NHP-50-240 frequently review these five Hybrid/Electric Heat Pump models ranked closest on capacity and UEF output.

5 closest certified peers matched by equipment class, storage volume, and efficiency rating
Brand & ModelTypeVolFHRUEF (Δ)kWh/yr
Ariston ARIHPWH-50-T Hybrid/Electric Heat Pump 45 gal 69 gal 3.83 (-0.02) 848
Lennox WHHP050T45MD240S**** Hybrid/Electric Heat Pump 45 gal 69 gal 3.83 (-0.02) 848
Friedrich PROH50 T2 FD400-30 Hybrid/Electric Heat Pump 45 gal 67 gal 3.88 (+0.03) 846
Rheem CPROPH50 T2 RH375-SO Hybrid/Electric Heat Pump 45 gal 67 gal 3.88 (+0.03) 846
Friedrich PROH50 T2 FD400-SO Hybrid/Electric Heat Pump 45 gal 67 gal 3.88 (+0.03) 846

When Should Homeowners Skip Noritz NHP-50-240 (Hybrid/Electric Heat Pump)?

Check Noritz NHP-50-240's mechanical constraints—including utility space, Electric capacity, and Pass: +1.55 / +67.4% status—against typical residential installations.

Key Limitations & Exclusions

  • Noritz NHP-50-240 needs >=450 cu ft room air volume or ducting so compressor cooling does not stall recovery.
  • Compressor runs near 48 dBA; avoid mounting Noritz NHP-50-240 directly beside quiet bedrooms.
  • Requires condensate drain routing and 240V electrical capacity; verify state DOE HEAR status.

Which Option Fits Your Situation?

High Electric Rate States Choosing Noritz NHP-50-240 Strong Fit — 3.85 UEF trims electric use ~75% vs 0.92 UEF tanks.
Open Basement or Garage (>=450 cu ft) Strong Fit — Ample ambient air sustains heat-pump-only efficiency.
Small Interior Closet (<300 cu ft) Caution — Add duct kit or compare Ariston ARIHPWH-50-T footprint.

Sizing, Efficiency & Recall Answers for Noritz NHP-50-240

Direct answers to common technical, regulatory, and sizing questions sourced from primary U.S. government and OEM documentation.

Will Noritz NHP-50-240 stay compliant after the May 6, 2029 DOE standard takes effect?

Tested at 3.85 UEF, Noritz NHP-50-240 shows Pass: +1.55 / +67.4% relative to May 6, 2029 federal DOE limits while placing #217 of 706 (top 31.2%) among 706 Hybrid/Electric Heat Pump peers like Ariston ARIHPWH-50-T.

Will Noritz NHP-50-240 fit through a standard utility door and 72-inch basement ceiling?

Measuring 61.4 in. tall by 22 in. diameter, Noritz NHP-50-240 notes: fits standard 72 in. basement/garage clearance; clears 28 in. utility doorway (22" d). Reserve space above the jacket for T&P piping and anode removal.

Do existing utility hookups support Noritz NHP-50-240 during replacement?

Electrical specs for Noritz NHP-50-240 call for 240V at 21.3A max (Requires 240V dedicated branch circuit; check panel capacity). Have a licensed electrician inspect panel load and wire gauge.

What is the estimated 10-year operating spend for Noritz NHP-50-240?

At 18.16 cents/kWh national residential pricing, Noritz NHP-50-240's 844 kWh/yr draw equals roughly $153 annually or $1,530 across a 10-year horizon (ranging from $123/yr in Washington hydro tiers up to $398/yr in Hawaii).

When is Noritz NHP-50-240 a poor fit for a residential replacement?

Avoid placing Noritz NHP-50-240 directly next to bedrooms or inside tight <300 cu ft closets without ducting, due to 48 dBA sound and cool exhaust airflow.

What First Hour Rating or flow capacity does Noritz NHP-50-240 deliver?

With 68 gal FHR (-4 gal vs. 72 gal median), Noritz NHP-50-240 fits larger 3–5 person homes cleanly.

How do you verify manufacturing age and recall status on Noritz NHP-50-240?

Our 2026-11-23 CPSC SaferProducts feed lists zero recalls for Noritz; verify exact manufacturing week for Noritz NHP-50-240 using the Serial Number Lookup tool.

Does Noritz NHP-50-240 qualify for DOE HEAR incentives after 25C expired?

After 25C sunset on Dec 31, 2025 under OBBBA, check state DOE HEAR (up to $1,750 income-qualified) and utility rebates for Noritz NHP-50-240. Closest peer in Hybrid/Electric Heat Pump is Ariston ARIHPWH-50-T (3.83 UEF).

Sources

  1. ENERGY STAR Certified Water Heaters Dataset (Socrata pbpq-swnu) — U.S. EPA & DOE ENERGY STAR, 2026 Live Certified Registry (retrieved 2026-11-23)
  2. 10 CFR 430.32 — Energy and Water Conservation Standards (Water Heaters & Plumbing Fixtures) — U.S. Department of Energy / eCFR, 2026 eCFR (incl. May 6, 2029 Rule) (retrieved 2026-11-23)
  3. CPSC SaferProducts.gov Product Recalls REST API — U.S. Consumer Product Safety Commission, 2026 Live Recalls Feed (retrieved 2026-11-23)
  4. EIA Electric Power Monthly Table 5.6.A — Average Residential Electricity Price by State — U.S. Energy Information Administration (EIA), August 2026 Monthly Release (retrieved 2026-11-23)

Related U.S. Metro Plumbing Benchmarks