Lochinvar LHPCO-45 1**+LXST-50T 1** Water Heater Specifications (3.52 UEF)
With PD 4529453 certification, Lochinvar LHPCO-45 1**+LXST-50T 1** (Hybrid/Electric Heat Pump, Electric) achieves a certified 3.52 UEF rating across its 45-gallon nominal tank, 67 gal First Hour Rating, standing #441 of 706 across 706 peers with Pass: +1.22 / +53.0% for May 6, 2029. Rated annual electricity draw of 923 kWh/yr equates to roughly $168/yr ($1,676 over 10 years) at 18.16 cents/kWh. Closest certified alternative is A. O. Smith HPACO-45 1**+AXST-50T 1** (3.52 UEF).
- Uniform Energy Factor
- 3.52 UEF
- Cohort UEF Rank
- #441 of 706
- First Hour Rating
- 67 gal
- Storage Volume
- 45 gal
- Fuel / Type
- Electric / Hybrid/Electric Heat Pump
- DOE 2029 Rule Status
- Pass: +1.22 / +53.0%

ENERGY STAR certification places Lochinvar LHPCO-45 1**+LXST-50T 1** at 3.52 UEF (#441 of 706; -0.18 UEF vs. 3.70 UEF median) in Hybrid/Electric Heat Pump.
May 6, 2029 readiness: Lochinvar LHPCO-45 1**+LXST-50T 1** stands +1.22 UEF (+53.0%) relative to 10 CFR 430.32(d)(2) Electric >35 to <=55 gal (2.30 UEF). At EIA August 2026 national rates (18.16 cents/kWh), 923 kWh/yr for Lochinvar LHPCO-45 1**+LXST-50T 1** runs ~$168/yr vs. ~$641/yr for a 0.92 UEF electric tank.
State electric sensitivity for Lochinvar LHPCO-45 1**+LXST-50T 1**: 10-year operating spend spans $1,350 in Washington (Lowest Hydro Tier) (14.63 cents/kWh) to $4,355 in Hawaii (Highest EIA State) (47.18 cents/kWh).
In the Hybrid/Electric Heat Pump tier, A. O. Smith HPACO-45 1**+AXST-50T 1** (3.52 UEF, at parity) and American MHPCO-45 1**+MXST-50T 1** (3.52 UEF, at parity) bracket Lochinvar LHPCO-45 1**+LXST-50T 1**.
What Physical and Thermal Ratings Define Lochinvar LHPCO-45 1**+LXST-50T 1**?
Positioning at #441 of 706 out of 706 Hybrid/Electric Heat Pump peers, Lochinvar LHPCO-45 1**+LXST-50T 1** pairs measured UEF performance with specific clearance and wiring rules.
| Specification Attribute | Certified Value | Cohort Benchmark / Delta | Provenance |
|---|---|---|---|
| Manufacturer / Brand | Lochinvar | 65 certified listings | ENERGY STAR PD 4529453 |
| Model Number | LHPCO-45 1**+LXST-50T 1** | Draw pattern: Medium-Usage | LHPCO-45 1**+LXST-50T 1** |
| Uniform Energy Factor (UEF) | 3.52 | -0.18 UEF vs. 3.70 UEF median | 10 CFR 430 Test Method |
| First Hour Rating (FHR) | 67 gal | -5 gal vs. 72 gal median | 10 CFR 430 Recovery Test |
| Rated Annual Electricity Use | 923 kWh/yr | -149 kWh/yr vs. 1,072 kWh/yr median | Est. $168/yr @ $0.1816/kWh (EIA US Avg) |
| Thermal Recovery Efficiency | 413% | -16.0 pts vs. 429.0% median | ENERGY STAR Dataset |
| Physical Envelope (H x Dia) | 57" H x 16" D | Fits standard 72 in. basement/garage clearance; clears 28 in. utility doorway (16" D) | Doorway & ceiling check |
| Electrical Circuit Requirements | 240 V / 20.2 A max | Requires 240V dedicated branch circuit; check panel capacity | NEC / Branch circuit check |
| Heat Pump Refrigerant & GWP | R-744 (CO₂) (GWP:1 | Lower GWP) | Lower-GWP refrigerant alignment (EPA AIM Act) | EPA AIM Act Compliance |
| Certification Date | 2026-02-25 | Certified 2026-02-25 | Markets: United States |
Why Do State Utility Rates Shift LHPCO-45 1**+LXST-50T 1** Running Costs?
Consuming 923 kWh annually puts Lochinvar LHPCO-45 1**+LXST-50T 1** near $168/yr at US baseline tariffs, with multi-state EIA comparisons charted below.
| Jurisdiction (EIA Aug 2026) | Residential Rate | Annual Cost | 10-Yr Operating Spend | 10-Yr Savings vs. 0.92 UEF |
|---|---|---|---|---|
| United States Average | 18.16 ¢/kWh ($0.1816) | $168/yr | $1,676 | $4,736 |
| Hawaii (Highest EIA State) | 47.18 ¢/kWh ($0.4718) | $435/yr | $4,355 | $12,305 |
| California | 29.75 ¢/kWh ($0.2975) | $275/yr | $2,746 | $7,759 |
| Texas | 15.91 ¢/kWh ($0.1591) | $147/yr | $1,468 | $4,149 |
| Washington (Lowest Hydro Tier) | 14.63 ¢/kWh ($0.1463) | $135/yr | $1,350 | $3,816 |
Have Any Lochinvar Series Triggered CPSC Recalls?
SaferProducts records retrieved 2026-11-23 list 1 brand notice under Lochinvar; inspect model coverage dates prior to valve or anode service. See Serial Number Lookup.
- Recall #05274 (2005-09-16): CPSC, Robertshaw Controls Co. Announce Recall of Gas Control Valves on Water Heaters (CPSC Notice)
What Are 5 Direct Alternatives to Lochinvar LHPCO-45 1**+LXST-50T 1**?
Homeowners cross-shopping Lochinvar LHPCO-45 1**+LXST-50T 1** frequently review these five Hybrid/Electric Heat Pump models ranked closest on capacity and UEF output.
| Brand & Model | Type | Vol | FHR | UEF (Δ) | kWh/yr |
|---|---|---|---|---|---|
| A. O. Smith HPACO-45 1**+AXST-50T 1** | Hybrid/Electric Heat Pump | 45 gal | 67 gal | 3.52 (at parity) | 923 |
| American MHPCO-45 1**+MXST-50T 1** | Hybrid/Electric Heat Pump | 45 gal | 67 gal | 3.52 (at parity) | 923 |
| Giant GHPCO-45 1**+GXST-50T 1** | Hybrid/Electric Heat Pump | 45 gal | 67 gal | 3.52 (at parity) | 923 |
| GSW WATER HEATERS GTHPCO-45 1**+GTXST-50T 1** | Hybrid/Electric Heat Pump | 45 gal | 67 gal | 3.52 (at parity) | 923 |
| A. O. Smith HPACO-45 1**+AXST-50TTTP 1** | Hybrid/Electric Heat Pump | 45 gal | 67 gal | 3.52 (at parity) | 923 |
Who Is Lochinvar LHPCO-45 1**+LXST-50T 1** Best For — and When Should You Pick A. O. Smith HPACO-45 1**+AXST-50T 1**?
Evaluate whether Lochinvar LHPCO-45 1**+LXST-50T 1**'s Hybrid/Electric Heat Pump architecture matches your existing mechanical room and local utility tariffs before purchasing.
Key Limitations & Exclusions
- Lochinvar LHPCO-45 1**+LXST-50T 1** needs >=450 cu ft room air volume or ducting so compressor cooling does not stall recovery.
- Compressor runs near 49 dBA; avoid mounting Lochinvar LHPCO-45 1**+LXST-50T 1** directly beside quiet bedrooms.
- Requires condensate drain routing and 240V electrical capacity; verify state DOE HEAR status.
Which Option Fits Your Situation?
Sizing, Efficiency & Recall Answers for Lochinvar LHPCO-45 1**+LXST-50T 1**
Direct answers to common technical, regulatory, and sizing questions sourced from primary U.S. government and OEM documentation.
How does Lochinvar LHPCO-45 1**+LXST-50T 1** (3.52 UEF) compare to 2029 federal DOE floors?
Evaluated against May 6, 2029 10 CFR 430.32 thresholds, Lochinvar LHPCO-45 1**+LXST-50T 1** records 3.52 UEF (Pass: +1.22 / +53.0%), placing #441 of 706 out of 706 certified Hybrid/Electric Heat Pump configurations.
Does Lochinvar LHPCO-45 1**+LXST-50T 1** fit inside a tight hallway closet or low-headroom utility room?
Lochinvar LHPCO-45 1**+LXST-50T 1** requires room for its 57 in. vertical shell and 16 in. diameter (fits standard 72 in. basement/garage clearance; clears 28 in. utility doorway (16" d)), plus service access for annual sediment draining.
What power supply or fuel line specs govern Lochinvar LHPCO-45 1**+LXST-50T 1**?
For Lochinvar LHPCO-45 1**+LXST-50T 1**, plan a 240V circuit at 20.2A max (Requires 240V dedicated branch circuit; check panel capacity) and keep a dedicated shutoff disconnect within sight of the unit.
What annual utility bill should homeowners budget for Lochinvar LHPCO-45 1**+LXST-50T 1**?
Using 923 kWh/yr, Lochinvar LHPCO-45 1**+LXST-50T 1** generates an estimated $168/yr electric bill at 18.16 cents/kWh (ranging from $135/yr in Washington hydro tiers up to $435/yr in Hawaii)—use the custom rate slider above for your utility tariff.
What are the main drawbacks of Lochinvar LHPCO-45 1**+LXST-50T 1** (3.52 UEF)?
Lochinvar LHPCO-45 1**+LXST-50T 1** requires >=450 cu ft air space, 240V electrical supply, and drain access; tight interior alcoves favor ducted adapters or A. O. Smith HPACO-45 1**+AXST-50T 1**.
What hot-water delivery rating governs Lochinvar LHPCO-45 1**+LXST-50T 1**?
Rated for 67 gal FHR (-5 gal vs. 72 gal median), Lochinvar LHPCO-45 1**+LXST-50T 1** prevents mid-morning cold drops when matched to 55–70+ gal multi-bath household loads.
Where do homeowners screen Lochinvar LHPCO-45 1**+LXST-50T 1** for recalls and tank age?
CPSC SaferProducts records show 1 brand-level recall notice mentioning Lochinvar as of 2026-11-23, including #05274 (2005-09-16). Enter the rating-plate serial into TapAndPipe's Serial Lookup tool to verify production week.
What alternative models sit closest to Lochinvar LHPCO-45 1**+LXST-50T 1** in the Hybrid/Electric Heat Pump class?
Closest peer in Hybrid/Electric Heat Pump is A. O. Smith HPACO-45 1**+AXST-50T 1** (3.52 UEF). For 2026 incentives, look to state DOE HEAR grants ($1,750 max on qualifying HPWHs) and local municipal utility credits.
Sources
- ENERGY STAR Certified Water Heaters Dataset (Socrata pbpq-swnu) — U.S. EPA & DOE ENERGY STAR, 2026 Live Certified Registry (retrieved 2026-11-23)
- 10 CFR 430.32 — Energy and Water Conservation Standards (Water Heaters & Plumbing Fixtures) — U.S. Department of Energy / eCFR, 2026 eCFR (incl. May 6, 2029 Rule) (retrieved 2026-11-23)
- CPSC SaferProducts.gov Product Recalls REST API — U.S. Consumer Product Safety Commission, 2026 Live Recalls Feed (retrieved 2026-11-23)
- EIA Electric Power Monthly Table 5.6.A — Average Residential Electricity Price by State — U.S. Energy Information Administration (EIA), August 2026 Monthly Release (retrieved 2026-11-23)