Skip to main content
ENERGY STAR water heater model · PD 4529453

Lochinvar LHPCO-45 1**+LXST-50T 1** Water Heater Specifications (3.52 UEF)

With PD 4529453 certification, Lochinvar LHPCO-45 1**+LXST-50T 1** (Hybrid/Electric Heat Pump, Electric) achieves a certified 3.52 UEF rating across its 45-gallon nominal tank, 67 gal First Hour Rating, standing #441 of 706 across 706 peers with Pass: +1.22 / +53.0% for May 6, 2029. Rated annual electricity draw of 923 kWh/yr equates to roughly $168/yr ($1,676 over 10 years) at 18.16 cents/kWh. Closest certified alternative is A. O. Smith HPACO-45 1**+AXST-50T 1** (3.52 UEF).

Uniform Energy Factor
3.52 UEF
Cohort UEF Rank
#441 of 706
First Hour Rating
67 gal
Storage Volume
45 gal
Fuel / Type
Electric / Hybrid/Electric Heat Pump
DOE 2029 Rule Status
Pass: +1.22 / +53.0%
Hybrid heat pump water heater upper shroud with brass relief valve and insulated copper risers
Hybrid heat pump water heater upper shroud with brass relief valve and insulated copper risers
Hybrid/Electric Heat Pump UEF Efficiency Distribution (706 Certified Units)Distribution of certified UEF ratings across 706 units in Hybrid/Electric Heat Pump, marking Lochinvar LHPCO-45 1**+LXST-50T 1** at 3.52 UEF.21130201631342031241542.52 UEF4.50 UEFMedian 3.702029 min 2.30Lochinvar LHPCO-45 1**+LXST-50T 1**: 3.52
Hybrid/Electric Heat Pump UEF Efficiency Distribution (706 Certified Units). Highlighted pin shows Lochinvar LHPCO-45 1**+LXST-50T 1** relative to the cohort median.
Efficiency comparison & rule summary

ENERGY STAR certification places Lochinvar LHPCO-45 1**+LXST-50T 1** at 3.52 UEF (#441 of 706; -0.18 UEF vs. 3.70 UEF median) in Hybrid/Electric Heat Pump.

May 6, 2029 readiness: Lochinvar LHPCO-45 1**+LXST-50T 1** stands +1.22 UEF (+53.0%) relative to 10 CFR 430.32(d)(2) Electric >35 to <=55 gal (2.30 UEF). At EIA August 2026 national rates (18.16 cents/kWh), 923 kWh/yr for Lochinvar LHPCO-45 1**+LXST-50T 1** runs ~$168/yr vs. ~$641/yr for a 0.92 UEF electric tank.

State electric sensitivity for Lochinvar LHPCO-45 1**+LXST-50T 1**: 10-year operating spend spans $1,350 in Washington (Lowest Hydro Tier) (14.63 cents/kWh) to $4,355 in Hawaii (Highest EIA State) (47.18 cents/kWh).

In the Hybrid/Electric Heat Pump tier, A. O. Smith HPACO-45 1**+AXST-50T 1** (3.52 UEF, at parity) and American MHPCO-45 1**+MXST-50T 1** (3.52 UEF, at parity) bracket Lochinvar LHPCO-45 1**+LXST-50T 1**.

What Physical and Thermal Ratings Define Lochinvar LHPCO-45 1**+LXST-50T 1**?

Positioning at #441 of 706 out of 706 Hybrid/Electric Heat Pump peers, Lochinvar LHPCO-45 1**+LXST-50T 1** pairs measured UEF performance with specific clearance and wiring rules.

Certified model attributes compared against 706 ENERGY STAR Hybrid/Electric Heat Pump peers
Specification AttributeCertified ValueCohort Benchmark / DeltaProvenance
Manufacturer / BrandLochinvar65 certified listingsENERGY STAR PD 4529453
Model NumberLHPCO-45 1**+LXST-50T 1**Draw pattern: Medium-UsageLHPCO-45 1**+LXST-50T 1**
Uniform Energy Factor (UEF)3.52-0.18 UEF vs. 3.70 UEF median10 CFR 430 Test Method
First Hour Rating (FHR)67 gal-5 gal vs. 72 gal median10 CFR 430 Recovery Test
Rated Annual Electricity Use923 kWh/yr-149 kWh/yr vs. 1,072 kWh/yr medianEst. $168/yr @ $0.1816/kWh (EIA US Avg)
Thermal Recovery Efficiency413%-16.0 pts vs. 429.0% medianENERGY STAR Dataset
Physical Envelope (H x Dia)57" H x 16" DFits standard 72 in. basement/garage clearance; clears 28 in. utility doorway (16" D)Doorway & ceiling check
Electrical Circuit Requirements240 V / 20.2 A maxRequires 240V dedicated branch circuit; check panel capacityNEC / Branch circuit check
Heat Pump Refrigerant & GWPR-744 (CO₂) (GWP:1 | Lower GWP)Lower-GWP refrigerant alignment (EPA AIM Act)EPA AIM Act Compliance
Certification Date2026-02-25Certified 2026-02-25Markets: United States

Why Do State Utility Rates Shift LHPCO-45 1**+LXST-50T 1** Running Costs?

Consuming 923 kWh annually puts Lochinvar LHPCO-45 1**+LXST-50T 1** near $168/yr at US baseline tariffs, with multi-state EIA comparisons charted below.

Estimated Annual Electricity Cost by State Rate (923 kWh/yr)Projected annual electricity spend across five benchmark EIA August 2026 residential electric tiers.United States Average$168.00/yrHawaii$435.00/yrCalifornia$275.00/yrTexas$147.00/yrWashington$135.00/yr
Projected annual electricity spend across five benchmark EIA August 2026 residential electric tiers.
Estimated electricity cost and 10-year spend across benchmark states
Jurisdiction (EIA Aug 2026)Residential RateAnnual Cost10-Yr Operating Spend10-Yr Savings vs. 0.92 UEF
United States Average 18.16 ¢/kWh ($0.1816) $168/yr $1,676 $4,736
Hawaii (Highest EIA State) 47.18 ¢/kWh ($0.4718) $435/yr $4,355 $12,305
California 29.75 ¢/kWh ($0.2975) $275/yr $2,746 $7,759
Texas 15.91 ¢/kWh ($0.1591) $147/yr $1,468 $4,149
Washington (Lowest Hydro Tier) 14.63 ¢/kWh ($0.1463) $135/yr $1,350 $3,816
Estimated electricity spend (923 kWh/yr)

Condensing Gas Tankless vs. Storage Tank Flow Path & Gas Supply Engineering schematic contrasting 199,000 BTU/h condensing tankless piping (3/4 in. gas supply, Category IV PVC vent, condensate drain) against a 40,000 BTU/h atmospheric tank. Condensing Gas Tankless (0.91–0.96 UEF) Secondary HX Cat IV PVC Vent Cold In Hot Out 3/4"–1" Gas 199K BTU/h Condensate Atmospheric Storage Tank (0.58–0.65 UEF) Type B Flue Anode Rod 40K BTU/h 1/2" Gas Up to 100 ft T&P 150 psi 50–85 gal FHR Reserve | 8–12 yr life
Technical comparison: condensing gas tankless units require 3/4 in.–1 in. IFGC Table 402.4 gas supply and Category IV condensate drainage, while atmospheric tanks run on 1/2 in. lines.

Have Any Lochinvar Series Triggered CPSC Recalls?

SaferProducts records retrieved 2026-11-23 list 1 brand notice under Lochinvar; inspect model coverage dates prior to valve or anode service. See Serial Number Lookup.

1 Brand Recall Notice Found in CPSC Feed — Verify Serial & Model Range
  • Recall #05274 (2005-09-16): CPSC, Robertshaw Controls Co. Announce Recall of Gas Control Valves on Water Heaters (CPSC Notice)

What Are 5 Direct Alternatives to Lochinvar LHPCO-45 1**+LXST-50T 1**?

Homeowners cross-shopping Lochinvar LHPCO-45 1**+LXST-50T 1** frequently review these five Hybrid/Electric Heat Pump models ranked closest on capacity and UEF output.

5 closest certified peers matched by equipment class, storage volume, and efficiency rating
Brand & ModelTypeVolFHRUEF (Δ)kWh/yr
A. O. Smith HPACO-45 1**+AXST-50T 1** Hybrid/Electric Heat Pump 45 gal 67 gal 3.52 (at parity) 923
American MHPCO-45 1**+MXST-50T 1** Hybrid/Electric Heat Pump 45 gal 67 gal 3.52 (at parity) 923
Giant GHPCO-45 1**+GXST-50T 1** Hybrid/Electric Heat Pump 45 gal 67 gal 3.52 (at parity) 923
GSW WATER HEATERS GTHPCO-45 1**+GTXST-50T 1** Hybrid/Electric Heat Pump 45 gal 67 gal 3.52 (at parity) 923
A. O. Smith HPACO-45 1**+AXST-50TTTP 1** Hybrid/Electric Heat Pump 45 gal 67 gal 3.52 (at parity) 923

Who Is Lochinvar LHPCO-45 1**+LXST-50T 1** Best For — and When Should You Pick A. O. Smith HPACO-45 1**+AXST-50T 1**?

Evaluate whether Lochinvar LHPCO-45 1**+LXST-50T 1**'s Hybrid/Electric Heat Pump architecture matches your existing mechanical room and local utility tariffs before purchasing.

Key Limitations & Exclusions

  • Lochinvar LHPCO-45 1**+LXST-50T 1** needs >=450 cu ft room air volume or ducting so compressor cooling does not stall recovery.
  • Compressor runs near 49 dBA; avoid mounting Lochinvar LHPCO-45 1**+LXST-50T 1** directly beside quiet bedrooms.
  • Requires condensate drain routing and 240V electrical capacity; verify state DOE HEAR status.

Which Option Fits Your Situation?

High Electric Rate States Choosing Lochinvar LHPCO-45 1**+LXST-50T 1** Strong Fit — 3.52 UEF trims electric use ~75% vs 0.92 UEF tanks.
Open Basement or Garage (>=450 cu ft) Strong Fit — Ample ambient air sustains heat-pump-only efficiency.
Small Interior Closet (<300 cu ft) Caution — Add duct kit or compare A. O. Smith HPACO-45 1**+AXST-50T 1** footprint.

Sizing, Efficiency & Recall Answers for Lochinvar LHPCO-45 1**+LXST-50T 1**

Direct answers to common technical, regulatory, and sizing questions sourced from primary U.S. government and OEM documentation.

How does Lochinvar LHPCO-45 1**+LXST-50T 1** (3.52 UEF) compare to 2029 federal DOE floors?

Evaluated against May 6, 2029 10 CFR 430.32 thresholds, Lochinvar LHPCO-45 1**+LXST-50T 1** records 3.52 UEF (Pass: +1.22 / +53.0%), placing #441 of 706 out of 706 certified Hybrid/Electric Heat Pump configurations.

Does Lochinvar LHPCO-45 1**+LXST-50T 1** fit inside a tight hallway closet or low-headroom utility room?

Lochinvar LHPCO-45 1**+LXST-50T 1** requires room for its 57 in. vertical shell and 16 in. diameter (fits standard 72 in. basement/garage clearance; clears 28 in. utility doorway (16" d)), plus service access for annual sediment draining.

What power supply or fuel line specs govern Lochinvar LHPCO-45 1**+LXST-50T 1**?

For Lochinvar LHPCO-45 1**+LXST-50T 1**, plan a 240V circuit at 20.2A max (Requires 240V dedicated branch circuit; check panel capacity) and keep a dedicated shutoff disconnect within sight of the unit.

What annual utility bill should homeowners budget for Lochinvar LHPCO-45 1**+LXST-50T 1**?

Using 923 kWh/yr, Lochinvar LHPCO-45 1**+LXST-50T 1** generates an estimated $168/yr electric bill at 18.16 cents/kWh (ranging from $135/yr in Washington hydro tiers up to $435/yr in Hawaii)—use the custom rate slider above for your utility tariff.

What are the main drawbacks of Lochinvar LHPCO-45 1**+LXST-50T 1** (3.52 UEF)?

Lochinvar LHPCO-45 1**+LXST-50T 1** requires >=450 cu ft air space, 240V electrical supply, and drain access; tight interior alcoves favor ducted adapters or A. O. Smith HPACO-45 1**+AXST-50T 1**.

What hot-water delivery rating governs Lochinvar LHPCO-45 1**+LXST-50T 1**?

Rated for 67 gal FHR (-5 gal vs. 72 gal median), Lochinvar LHPCO-45 1**+LXST-50T 1** prevents mid-morning cold drops when matched to 55–70+ gal multi-bath household loads.

Where do homeowners screen Lochinvar LHPCO-45 1**+LXST-50T 1** for recalls and tank age?

CPSC SaferProducts records show 1 brand-level recall notice mentioning Lochinvar as of 2026-11-23, including #05274 (2005-09-16). Enter the rating-plate serial into TapAndPipe's Serial Lookup tool to verify production week.

What alternative models sit closest to Lochinvar LHPCO-45 1**+LXST-50T 1** in the Hybrid/Electric Heat Pump class?

Closest peer in Hybrid/Electric Heat Pump is A. O. Smith HPACO-45 1**+AXST-50T 1** (3.52 UEF). For 2026 incentives, look to state DOE HEAR grants ($1,750 max on qualifying HPWHs) and local municipal utility credits.

Sources

  1. ENERGY STAR Certified Water Heaters Dataset (Socrata pbpq-swnu) — U.S. EPA & DOE ENERGY STAR, 2026 Live Certified Registry (retrieved 2026-11-23)
  2. 10 CFR 430.32 — Energy and Water Conservation Standards (Water Heaters & Plumbing Fixtures) — U.S. Department of Energy / eCFR, 2026 eCFR (incl. May 6, 2029 Rule) (retrieved 2026-11-23)
  3. CPSC SaferProducts.gov Product Recalls REST API — U.S. Consumer Product Safety Commission, 2026 Live Recalls Feed (retrieved 2026-11-23)
  4. EIA Electric Power Monthly Table 5.6.A — Average Residential Electricity Price by State — U.S. Energy Information Administration (EIA), August 2026 Monthly Release (retrieved 2026-11-23)

Related U.S. Metro Plumbing Benchmarks