Skip to main content
ENERGY STAR water heater model · PD 4529449

Lochinvar LHPCO-45 1**+LXST-50TTTP 1** Water Heater Specifications (3.52 UEF)

In the 706-unit Hybrid/Electric Heat Pump class, Lochinvar LHPCO-45 1**+LXST-50TTTP 1** (Electric) achieves a certified 3.52 UEF rating across its 45-gallon nominal tank, 67 gal First Hour Rating (rank #441 of 706, PD 4529449) and verifies as Pass: +1.22 / +53.0% for 2029 DOE floors. Rated annual electricity draw of 923 kWh/yr equates to roughly $168/yr ($1,676 over 10 years) at 18.16 cents/kWh. Closest certified alternative is A. O. Smith HPACO-45 1**+AXST-50T 1** (3.52 UEF).

Uniform Energy Factor
3.52 UEF
Cohort UEF Rank
#441 of 706
First Hour Rating
67 gal
Storage Volume
45 gal
Fuel / Type
Electric / Hybrid/Electric Heat Pump
DOE 2029 Rule Status
Pass: +1.22 / +53.0%
Hybrid heat pump water heater upper shroud with brass relief valve and insulated copper risers
Hybrid heat pump water heater upper shroud with brass relief valve and insulated copper risers
Hybrid/Electric Heat Pump UEF Efficiency Distribution (706 Certified Units)Distribution of certified UEF ratings across 706 units in Hybrid/Electric Heat Pump, marking Lochinvar LHPCO-45 1**+LXST-50TTTP 1** at 3.52 UEF.21130201631342031241542.52 UEF4.50 UEFMedian 3.702029 min 2.30Lochinvar LHPCO-45 1**+LXST-50TTTP 1**: 3.52
Hybrid/Electric Heat Pump UEF Efficiency Distribution (706 Certified Units). Highlighted pin shows Lochinvar LHPCO-45 1**+LXST-50TTTP 1** relative to the cohort median.
Efficiency comparison & rule summary

Lochinvar LHPCO-45 1**+LXST-50TTTP 1** records 3.52 UEF efficiency, putting it #441 of 706 among 706 Hybrid/Electric Heat Pump peers.

10 CFR 430.32(d)(2) compliance: Lochinvar LHPCO-45 1**+LXST-50TTTP 1** exceeds 10 CFR 430.32(d)(2) Electric >35 to <=55 gal (2.30 UEF) by +1.22 UEF (+53.0%). At EIA August 2026 national rates (18.16 cents/kWh), 923 kWh/yr for Lochinvar LHPCO-45 1**+LXST-50TTTP 1** runs ~$168/yr vs. ~$641/yr for a 0.92 UEF electric tank.

State electric sensitivity for Lochinvar LHPCO-45 1**+LXST-50TTTP 1**: 10-year operating spend spans $1,350 in Washington (Lowest Hydro Tier) (14.63 cents/kWh) to $4,355 in Hawaii (Highest EIA State) (47.18 cents/kWh).

Competing options beside Lochinvar LHPCO-45 1**+LXST-50TTTP 1** (3.52 UEF) are A. O. Smith HPACO-45 1**+AXST-50T 1** (3.52 UEF, at parity) and American MHPCO-45 1**+MXST-50T 1** (3.52 UEF, at parity).

Which Specs Set Lochinvar LHPCO-45 1**+LXST-50TTTP 1** Apart From Cohort Averages?

Ranked #441 of 706 inside the 706-model Hybrid/Electric Heat Pump cohort, Lochinvar LHPCO-45 1**+LXST-50TTTP 1** is evaluated row by row below against category medians.

Certified model attributes compared against 706 ENERGY STAR Hybrid/Electric Heat Pump peers
Specification AttributeCertified ValueCohort Benchmark / DeltaProvenance
Manufacturer / BrandLochinvar65 certified listingsENERGY STAR PD 4529449
Model NumberLHPCO-45 1**+LXST-50TTTP 1**Draw pattern: Medium-UsageLHPCO-45 1**+LXST-50TTTP 1**
Uniform Energy Factor (UEF)3.52-0.18 UEF vs. 3.70 UEF median10 CFR 430 Test Method
First Hour Rating (FHR)67 gal-5 gal vs. 72 gal median10 CFR 430 Recovery Test
Rated Annual Electricity Use923 kWh/yr-149 kWh/yr vs. 1,072 kWh/yr medianEst. $168/yr @ $0.1816/kWh (EIA US Avg)
Thermal Recovery Efficiency413%-16.0 pts vs. 429.0% medianENERGY STAR Dataset
Physical Envelope (H x Dia)57" H x 16" DFits standard 72 in. basement/garage clearance; clears 28 in. utility doorway (16" D)Doorway & ceiling check
Electrical Circuit Requirements240 V / 20.2 A maxRequires 240V dedicated branch circuit; check panel capacityNEC / Branch circuit check
Heat Pump Refrigerant & GWPR-744 (CO₂) (GWP:1 | Lower GWP)Lower-GWP refrigerant alignment (EPA AIM Act)EPA AIM Act Compliance
Certification Date2026-02-25Certified 2026-02-25Markets: United States

How Do Regional kWh Prices Impact LHPCO-45 1**+LXST-50TTTP 1** Over 10 Years?

Using EIA Table 5.6.A benchmarks, Lochinvar LHPCO-45 1**+LXST-50TTTP 1**'s 923 kWh/yr draw translates to roughly $168/yr on typical US residential bills.

Estimated Annual Electricity Cost by State Rate (923 kWh/yr)Projected annual electricity spend across five benchmark EIA August 2026 residential electric tiers.United States Average$168.00/yrHawaii$435.00/yrCalifornia$275.00/yrTexas$147.00/yrWashington$135.00/yr
Projected annual electricity spend across five benchmark EIA August 2026 residential electric tiers.
Estimated electricity cost and 10-year spend across benchmark states
Jurisdiction (EIA Aug 2026)Residential RateAnnual Cost10-Yr Operating Spend10-Yr Savings vs. 0.92 UEF
United States Average 18.16 ¢/kWh ($0.1816) $168/yr $1,676 $4,736
Hawaii (Highest EIA State) 47.18 ¢/kWh ($0.4718) $435/yr $4,355 $12,305
California 29.75 ¢/kWh ($0.2975) $275/yr $2,746 $7,759
Texas 15.91 ¢/kWh ($0.1591) $147/yr $1,468 $4,149
Washington (Lowest Hydro Tier) 14.63 ¢/kWh ($0.1463) $135/yr $1,350 $3,816
Estimated electricity spend (923 kWh/yr)

Condensing Gas Tankless vs. Storage Tank Flow Path & Gas Supply Engineering schematic contrasting 199,000 BTU/h condensing tankless piping (3/4 in. gas supply, Category IV PVC vent, condensate drain) against a 40,000 BTU/h atmospheric tank. Condensing Gas Tankless (0.91–0.96 UEF) Secondary HX Cat IV PVC Vent Cold In Hot Out 3/4"–1" Gas 199K BTU/h Condensate Atmospheric Storage Tank (0.58–0.65 UEF) Type B Flue Anode Rod 40K BTU/h 1/2" Gas Up to 100 ft T&P 150 psi 50–85 gal FHR Reserve | 8–12 yr life
Technical comparison: condensing gas tankless units require 3/4 in.–1 in. IFGC Table 402.4 gas supply and Category IV condensate drainage, while atmospheric tanks run on 1/2 in. lines.

What Should Lochinvar Owners Check in CPSC Recall Logs?

The 2026-11-23 CPSC SaferProducts snapshot includes 1 filing tied to Lochinvar; verify whether your LHPCO-45 1**+LXST-50TTTP 1** production run falls inside affected ranges. See Serial Number Lookup.

1 Brand Recall Notice Found in CPSC Feed — Verify Serial & Model Range
  • Recall #05274 (2005-09-16): CPSC, Robertshaw Controls Co. Announce Recall of Gas Control Valves on Water Heaters (CPSC Notice)

How Do Five Nearby Hybrid/Electric Heat Pump Models Stack Up?

Five alternative Hybrid/Electric Heat Pump units with nearly identical gallon storage and UEF scores are listed below alongside exact efficiency spreads.

5 closest certified peers matched by equipment class, storage volume, and efficiency rating
Brand & ModelTypeVolFHRUEF (Δ)kWh/yr
A. O. Smith HPACO-45 1**+AXST-50T 1** Hybrid/Electric Heat Pump 45 gal 67 gal 3.52 (at parity) 923
American MHPCO-45 1**+MXST-50T 1** Hybrid/Electric Heat Pump 45 gal 67 gal 3.52 (at parity) 923
Giant GHPCO-45 1**+GXST-50T 1** Hybrid/Electric Heat Pump 45 gal 67 gal 3.52 (at parity) 923
GSW WATER HEATERS GTHPCO-45 1**+GTXST-50T 1** Hybrid/Electric Heat Pump 45 gal 67 gal 3.52 (at parity) 923
A. O. Smith HPACO-45 1**+AXST-50TTTP 1** Hybrid/Electric Heat Pump 45 gal 67 gal 3.52 (at parity) 923

What Are the Limitations of Lochinvar LHPCO-45 1**+LXST-50TTTP 1** and Who Should Not Install It?

Before ordering Lochinvar LHPCO-45 1**+LXST-50TTTP 1** (Hybrid/Electric Heat Pump, 3.52 UEF), weigh space clearances, fuel piping, noise (standard dBA), and 2029 rule readiness across three scenarios.

Key Limitations & Exclusions

  • Lochinvar LHPCO-45 1**+LXST-50TTTP 1** needs >=450 cu ft room air volume or ducting so compressor cooling does not stall recovery.
  • Compressor runs near 49 dBA; avoid mounting Lochinvar LHPCO-45 1**+LXST-50TTTP 1** directly beside quiet bedrooms.
  • Requires condensate drain routing and 240V electrical capacity; verify state DOE HEAR status.

Which Option Fits Your Situation?

High Electric Rate States Choosing Lochinvar LHPCO-45 1**+LXST-50TTTP 1** Strong Fit — 3.52 UEF trims electric use ~75% vs 0.92 UEF tanks.
Open Basement or Garage (>=450 cu ft) Strong Fit — Ample ambient air sustains heat-pump-only efficiency.
Small Interior Closet (<300 cu ft) Caution — Add duct kit or compare A. O. Smith HPACO-45 1**+AXST-50T 1** footprint.

Frequently Asked Technical Questions: Lochinvar LHPCO-45 1**+LXST-50TTTP 1**

Direct answers to common technical, regulatory, and sizing questions sourced from primary U.S. government and OEM documentation.

Does Lochinvar LHPCO-45 1**+LXST-50TTTP 1** pass the May 6, 2029 federal DOE efficiency rule?

Lochinvar LHPCO-45 1**+LXST-50TTTP 1** carries a verified 3.52 UEF rating (Pass: +1.22 / +53.0%), ranking #441 of 706 across 706 ENERGY STAR Hybrid/Electric Heat Pump models under 10 CFR 430.32.

What doorway width and ceiling height does Lochinvar LHPCO-45 1**+LXST-50TTTP 1** need?

Lochinvar LHPCO-45 1**+LXST-50TTTP 1** stands 57 in. high with a 16 in. diameter; fits standard 72 in. basement/garage clearance; clears 28 in. utility doorway (16" d). Leave overhead clearance for dielectric nipples, ball shutoff valves, and top air filters.

What gas pipe size or electrical breaker does Lochinvar LHPCO-45 1**+LXST-50TTTP 1** require?

Lochinvar LHPCO-45 1**+LXST-50TTTP 1** uses a 240V branch circuit at 20.2A max (Requires 240V dedicated branch circuit; check panel capacity). Verify main breaker space before replacing a gas tank with an electric hybrid unit.

How much electricity or energy does Lochinvar LHPCO-45 1**+LXST-50TTTP 1** cost per year to run?

Rated at 923 kWh/yr, Lochinvar LHPCO-45 1**+LXST-50TTTP 1** costs about $168/yr ($1,680 over 10 years) at the August 2026 EIA US average of 18.16 cents/kWh (ranging from $135/yr in Washington hydro tiers up to $435/yr in Hawaii).

Who should NOT install Lochinvar LHPCO-45 1**+LXST-50TTTP 1**, and what are its limits?

Lochinvar LHPCO-45 1**+LXST-50TTTP 1** (3.52 UEF) is a poor fit for unvented closets under 450 cu ft because compressor intake chills enclosed rooms and runs at 49 dBA.

How many bathrooms or people can Lochinvar LHPCO-45 1**+LXST-50TTTP 1** serve at peak demand?

Lochinvar LHPCO-45 1**+LXST-50TTTP 1** achieves a 67 gal First Hour Rating (-5 gal vs. 72 gal median). Two back-to-back showers plus a dishwasher run typically call for 55–70 gal FHR.

Are there CPSC safety recalls or serial checks for Lochinvar LHPCO-45 1**+LXST-50TTTP 1**?

CPSC SaferProducts records show 1 brand-level recall notice mentioning Lochinvar as of 2026-11-23, including #05274 (2005-09-16). Enter the rating-plate serial into TapAndPipe's Serial Lookup tool to verify production week.

What 2026 rebates apply to Lochinvar LHPCO-45 1**+LXST-50TTTP 1**, and what peer compares closest?

Federal Section 25C expired Dec 31, 2025 (P.L. 119-21); qualifying HPWHs remain eligible for state DOE HEAR rebates up to $1,750 (<=150% AMI). Closest peer in Hybrid/Electric Heat Pump is A. O. Smith HPACO-45 1**+AXST-50T 1** (3.52 UEF).

Sources

  1. ENERGY STAR Certified Water Heaters Dataset (Socrata pbpq-swnu) — U.S. EPA & DOE ENERGY STAR, 2026 Live Certified Registry (retrieved 2026-11-23)
  2. 10 CFR 430.32 — Energy and Water Conservation Standards (Water Heaters & Plumbing Fixtures) — U.S. Department of Energy / eCFR, 2026 eCFR (incl. May 6, 2029 Rule) (retrieved 2026-11-23)
  3. CPSC SaferProducts.gov Product Recalls REST API — U.S. Consumer Product Safety Commission, 2026 Live Recalls Feed (retrieved 2026-11-23)
  4. EIA Electric Power Monthly Table 5.6.A — Average Residential Electricity Price by State — U.S. Energy Information Administration (EIA), August 2026 Monthly Release (retrieved 2026-11-23)

Related U.S. Metro Plumbing Benchmarks