Skip to main content
ENERGY STAR water heater model · PD 3543523

Midea MAHW-50VN3A Water Heater Specifications (3.75 UEF)

With PD 3543523 certification, Midea MAHW-50VN3A (Hybrid/Electric Heat Pump, Electric) achieves a certified 3.75 UEF rating across its 47-gallon nominal tank, 69 gal First Hour Rating, standing #297 of 706 across 706 peers with Pass: +1.45 / +63.0% for May 6, 2029. Rated annual electricity draw of 855 kWh/yr equates to roughly $155/yr ($1,553 over 10 years) at 18.16 cents/kWh. Closest certified alternative is 1HVAC ACIQ-50G-HP-WH (3.75 UEF).

Uniform Energy Factor
3.75 UEF
Cohort UEF Rank
#297 of 706
First Hour Rating
69 gal
Storage Volume
47 gal
Fuel / Type
Electric / Hybrid/Electric Heat Pump
DOE 2029 Rule Status
Pass: +1.45 / +63.0%
Hybrid heat pump water heater upper shroud with brass relief valve and insulated copper risers
Hybrid heat pump water heater upper shroud with brass relief valve and insulated copper risers
Hybrid/Electric Heat Pump UEF Efficiency Distribution (706 Certified Units)Distribution of certified UEF ratings across 706 units in Hybrid/Electric Heat Pump, marking Midea MAHW-50VN3A at 3.75 UEF.21130201631342031241542.52 UEF4.50 UEFMedian 3.702029 min 2.30Midea MAHW-50VN3A: 3.75
Hybrid/Electric Heat Pump UEF Efficiency Distribution (706 Certified Units). Highlighted pin shows Midea MAHW-50VN3A relative to the cohort median.
Efficiency comparison & rule summary

ENERGY STAR certification places Midea MAHW-50VN3A at 3.75 UEF (#297 of 706; +0.05 UEF vs. 3.70 UEF median) in Hybrid/Electric Heat Pump.

May 6, 2029 readiness: Midea MAHW-50VN3A stands +1.45 UEF (+63.0%) relative to 10 CFR 430.32(d)(2) Electric >35 to <=55 gal (2.30 UEF). At EIA August 2026 national rates (18.16 cents/kWh), 855 kWh/yr for Midea MAHW-50VN3A runs ~$155/yr vs. ~$633/yr for a 0.92 UEF electric tank. Acoustic output is 49 dBA (quieter than 12.8% of Hybrid/Electric Heat Pump models).

State electric sensitivity for Midea MAHW-50VN3A: 10-year operating spend spans $1,251 in Washington (Lowest Hydro Tier) (14.63 cents/kWh) to $4,034 in Hawaii (Highest EIA State) (47.18 cents/kWh).

In the Hybrid/Electric Heat Pump tier, 1HVAC ACIQ-50G-HP-WH (3.75 UEF, at parity) and ACIQ ACIQ-50G-HP-WH (3.75 UEF, at parity) bracket Midea MAHW-50VN3A.

What Physical and Thermal Ratings Define Midea MAHW-50VN3A?

Positioning at #297 of 706 out of 706 Hybrid/Electric Heat Pump peers, Midea MAHW-50VN3A pairs measured UEF performance with specific clearance and wiring rules.

Certified model attributes compared against 706 ENERGY STAR Hybrid/Electric Heat Pump peers
Specification AttributeCertified ValueCohort Benchmark / DeltaProvenance
Manufacturer / BrandMidea49 certified listingsENERGY STAR PD 3543523
Model NumberMAHW-50VN3ADraw pattern: Medium-UsageMAHW-50VN3A
Uniform Energy Factor (UEF)3.75+0.05 UEF vs. 3.70 UEF median10 CFR 430 Test Method
First Hour Rating (FHR)69 gal-3 gal vs. 72 gal median10 CFR 430 Recovery Test
Rated Annual Electricity Use855 kWh/yr-217 kWh/yr vs. 1,072 kWh/yr medianEst. $155/yr @ $0.1816/kWh (EIA US Avg)
Thermal Recovery Efficiency430%+1.0 pts vs. 429.0% medianENERGY STAR Dataset
Physical Envelope (H x Dia)47.9" H x 18.3" DFits standard 72 in. basement/garage clearance; clears 28 in. utility doorway (18.3" D)Doorway & ceiling check
Electrical Circuit Requirements240 V / 24 A maxRequires 240V dedicated branch circuit; check panel capacityNEC / Branch circuit check
Heat Pump Refrigerant & GWPR-134a (GWP:1430)Check regional AIM Act phase-down transitionEPA AIM Act Compliance
Sound Pressure Level49 dBAquieter than 12.8% of Hybrid/Electric Heat Pump models · At 49 dBA medianIndoor placement check
Certification Date2024-11-04Certified 2024-11-04Markets: United States, Canada

Why Do State Utility Rates Shift MAHW-50VN3A Running Costs?

Consuming 855 kWh annually puts Midea MAHW-50VN3A near $155/yr at US baseline tariffs, with multi-state EIA comparisons charted below.

Estimated Annual Electricity Cost by State Rate (855 kWh/yr)Projected annual electricity spend across five benchmark EIA August 2026 residential electric tiers.United States Average$155.00/yrHawaii$403.00/yrCalifornia$254.00/yrTexas$136.00/yrWashington$125.00/yr
Projected annual electricity spend across five benchmark EIA August 2026 residential electric tiers.
Estimated electricity cost and 10-year spend across benchmark states
Jurisdiction (EIA Aug 2026)Residential RateAnnual Cost10-Yr Operating Spend10-Yr Savings vs. 0.92 UEF
United States Average 18.16 ¢/kWh ($0.1816) $155/yr $1,553 $4,776
Hawaii (Highest EIA State) 47.18 ¢/kWh ($0.4718) $403/yr $4,034 $12,408
California 29.75 ¢/kWh ($0.2975) $254/yr $2,544 $7,824
Texas 15.91 ¢/kWh ($0.1591) $136/yr $1,360 $4,184
Washington (Lowest Hydro Tier) 14.63 ¢/kWh ($0.1463) $125/yr $1,251 $3,848
Estimated electricity spend (855 kWh/yr)

Condensing Gas Tankless vs. Storage Tank Flow Path & Gas Supply Engineering schematic contrasting 199,000 BTU/h condensing tankless piping (3/4 in. gas supply, Category IV PVC vent, condensate drain) against a 40,000 BTU/h atmospheric tank. Condensing Gas Tankless (0.91–0.96 UEF) Secondary HX Cat IV PVC Vent Cold In Hot Out 3/4"–1" Gas 199K BTU/h Condensate Atmospheric Storage Tank (0.58–0.65 UEF) Type B Flue Anode Rod 40K BTU/h 1/2" Gas Up to 100 ft T&P 150 psi 50–85 gal FHR Reserve | 8–12 yr life
Technical comparison: condensing gas tankless units require 3/4 in.–1 in. IFGC Table 402.4 gas supply and Category IV condensate drainage, while atmospheric tanks run on 1/2 in. lines.

Have Any Midea Series Triggered CPSC Recalls?

SaferProducts screening on 2026-11-23 returned zero recall matches for Midea; confirm tank age separately using the rating-plate serial pattern. See Serial Number Lookup.

What Are 5 Direct Alternatives to Midea MAHW-50VN3A?

Homeowners cross-shopping Midea MAHW-50VN3A frequently review these five Hybrid/Electric Heat Pump models ranked closest on capacity and UEF output.

5 closest certified peers matched by equipment class, storage volume, and efficiency rating
Brand & ModelTypeVolFHRUEF (Δ)kWh/yr
1HVAC ACIQ-50G-HP-WH Hybrid/Electric Heat Pump 47 gal 69 gal 3.75 (at parity) 855
ACIQ ACIQ-50G-HP-WH Hybrid/Electric Heat Pump 47 gal 69 gal 3.75 (at parity) 855
Bosch TR7000T - 50CA Hybrid/Electric Heat Pump 47 gal 69 gal 3.75 (at parity) 855
Custom Comfort CCOHPWH50A Hybrid/Electric Heat Pump 47 gal 69 gal 3.75 (at parity) 855
Bosch TR7000T - 50US Hybrid/Electric Heat Pump 47 gal 69 gal 3.75 (at parity) 855

Who Is Midea MAHW-50VN3A Best For — and When Should You Pick 1HVAC ACIQ-50G-HP-WH?

Evaluate whether Midea MAHW-50VN3A's Hybrid/Electric Heat Pump architecture matches your existing mechanical room and local utility tariffs before purchasing.

Key Limitations & Exclusions

  • Midea MAHW-50VN3A needs >=450 cu ft room air volume or ducting so compressor cooling does not stall recovery.
  • Compressor runs near 49 dBA; avoid mounting Midea MAHW-50VN3A directly beside quiet bedrooms.
  • Requires condensate drain routing and 240V electrical capacity; verify state DOE HEAR status.

Which Option Fits Your Situation?

High Electric Rate States Choosing Midea MAHW-50VN3A Strong Fit — 3.75 UEF trims electric use ~75% vs 0.92 UEF tanks.
Open Basement or Garage (>=450 cu ft) Strong Fit — Ample ambient air sustains heat-pump-only efficiency.
Small Interior Closet (<300 cu ft) Caution — Add duct kit or compare 1HVAC ACIQ-50G-HP-WH footprint.

Sizing, Efficiency & Recall Answers for Midea MAHW-50VN3A

Direct answers to common technical, regulatory, and sizing questions sourced from primary U.S. government and OEM documentation.

How does Midea MAHW-50VN3A (3.75 UEF) compare to 2029 federal DOE floors?

Evaluated against May 6, 2029 10 CFR 430.32 thresholds, Midea MAHW-50VN3A records 3.75 UEF (Pass: +1.45 / +63.0%), placing #297 of 706 out of 706 certified Hybrid/Electric Heat Pump configurations.

Does Midea MAHW-50VN3A fit inside a tight hallway closet or low-headroom utility room?

Midea MAHW-50VN3A requires room for its 47.9 in. vertical shell and 18.3 in. diameter (fits standard 72 in. basement/garage clearance; clears 28 in. utility doorway (18.3" d)), plus service access for annual sediment draining.

What power supply or fuel line specs govern Midea MAHW-50VN3A?

For Midea MAHW-50VN3A, plan a 240V circuit at 24A max (Requires 240V dedicated branch circuit; check panel capacity) and keep a dedicated shutoff disconnect within sight of the unit.

What annual utility bill should homeowners budget for Midea MAHW-50VN3A?

Using 855 kWh/yr, Midea MAHW-50VN3A generates an estimated $155/yr electric bill at 18.16 cents/kWh (ranging from $125/yr in Washington hydro tiers up to $403/yr in Hawaii)—use the custom rate slider above for your utility tariff.

What are the main drawbacks of Midea MAHW-50VN3A (3.75 UEF)?

Midea MAHW-50VN3A requires >=450 cu ft air space, 240V electrical supply, and drain access; tight interior alcoves favor ducted adapters or 1HVAC ACIQ-50G-HP-WH.

What hot-water delivery rating governs Midea MAHW-50VN3A?

Rated for 69 gal FHR (-3 gal vs. 72 gal median), Midea MAHW-50VN3A prevents mid-morning cold drops when matched to 55–70+ gal multi-bath household loads.

Where do homeowners screen Midea MAHW-50VN3A for recalls and tank age?

Verified clean against 2026-11-23 CPSC recall feeds for Midea; use our browser-only serial decoder to inspect Midea MAHW-50VN3A's age and warranty window.

What alternative models sit closest to Midea MAHW-50VN3A in the Hybrid/Electric Heat Pump class?

Closest peer in Hybrid/Electric Heat Pump is 1HVAC ACIQ-50G-HP-WH (3.75 UEF). For 2026 incentives, look to state DOE HEAR grants ($1,750 max on qualifying HPWHs) and local municipal utility credits.

Sources

  1. ENERGY STAR Certified Water Heaters Dataset (Socrata pbpq-swnu) — U.S. EPA & DOE ENERGY STAR, 2026 Live Certified Registry (retrieved 2026-11-23)
  2. 10 CFR 430.32 — Energy and Water Conservation Standards (Water Heaters & Plumbing Fixtures) — U.S. Department of Energy / eCFR, 2026 eCFR (incl. May 6, 2029 Rule) (retrieved 2026-11-23)
  3. CPSC SaferProducts.gov Product Recalls REST API — U.S. Consumer Product Safety Commission, 2026 Live Recalls Feed (retrieved 2026-11-23)
  4. EIA Electric Power Monthly Table 5.6.A — Average Residential Electricity Price by State — U.S. Energy Information Administration (EIA), August 2026 Monthly Release (retrieved 2026-11-23)

Related U.S. Metro Plumbing Benchmarks