Midea MAWH50D2AKH Water Heater Specifications (3.75 UEF)
Certified at 3.75 UEF across its 47-gallon nominal tank, 69 gal First Hour Rating, Midea MAWH50D2AKH (Hybrid/Electric Heat Pump, Electric) places #297 of 706 out of 706 ENERGY STAR models (PD 3722156). Its May 6, 2029 10 CFR 430.32 status reads Pass: +1.45 / +63.0%. Rated annual electricity draw of 855 kWh/yr equates to roughly $155/yr ($1,553 over 10 years) at 18.16 cents/kWh. Closest certified alternative is 1HVAC ACIQ-50G-HP-WH (3.75 UEF).
- Uniform Energy Factor
- 3.75 UEF
- Cohort UEF Rank
- #297 of 706
- First Hour Rating
- 69 gal
- Storage Volume
- 47 gal
- Fuel / Type
- Electric / Hybrid/Electric Heat Pump
- DOE 2029 Rule Status
- Pass: +1.45 / +63.0%

Tested at 3.75 UEF, Midea MAWH50D2AKH places #297 of 706 across 706 certified Hybrid/Electric Heat Pump configurations (+0.05 UEF vs. 3.70 UEF median).
Midea MAWH50D2AKH clears 10 CFR 430.32(d)(2) Electric >35 to <=55 gal (2.30 UEF) by +1.45 UEF (+63.0% headroom). At EIA August 2026 national rates (18.16 cents/kWh), 855 kWh/yr for Midea MAWH50D2AKH runs ~$155/yr vs. ~$633/yr for a 0.92 UEF electric tank. Acoustic output is 49 dBA (quieter than 12.8% of Hybrid/Electric Heat Pump models).
State electric sensitivity for Midea MAWH50D2AKH: 10-year operating spend spans $1,251 in Washington (Lowest Hydro Tier) (14.63 cents/kWh) to $4,034 in Hawaii (Highest EIA State) (47.18 cents/kWh).
Closest alternatives to Midea MAWH50D2AKH include 1HVAC ACIQ-50G-HP-WH (3.75 UEF, at parity) alongside ACIQ ACIQ-50G-HP-WH (3.75 UEF, at parity).
Which Specs Set Midea MAWH50D2AKH Apart From Cohort Averages?
Ranked #297 of 706 inside the 706-model Hybrid/Electric Heat Pump cohort, Midea MAWH50D2AKH is evaluated row by row below against category medians.
| Specification Attribute | Certified Value | Cohort Benchmark / Delta | Provenance |
|---|---|---|---|
| Manufacturer / Brand | Midea | 49 certified listings | ENERGY STAR PD 3722156 |
| Model Number | MAWH50D2AKH | Draw pattern: Medium-Usage | MAWH50D2AKH |
| Uniform Energy Factor (UEF) | 3.75 | +0.05 UEF vs. 3.70 UEF median | 10 CFR 430 Test Method |
| First Hour Rating (FHR) | 69 gal | -3 gal vs. 72 gal median | 10 CFR 430 Recovery Test |
| Rated Annual Electricity Use | 855 kWh/yr | -217 kWh/yr vs. 1,072 kWh/yr median | Est. $155/yr @ $0.1816/kWh (EIA US Avg) |
| Thermal Recovery Efficiency | 430% | +1.0 pts vs. 429.0% median | ENERGY STAR Dataset |
| Physical Envelope (H x Dia) | 47.9" H x 18.3" D | Fits standard 72 in. basement/garage clearance; clears 28 in. utility doorway (18.3" D) | Doorway & ceiling check |
| Electrical Circuit Requirements | 240 V / 24 A max | Requires 240V dedicated branch circuit; check panel capacity | NEC / Branch circuit check |
| Heat Pump Refrigerant & GWP | R-134a (GWP:1430) | Check regional AIM Act phase-down transition | EPA AIM Act Compliance |
| Sound Pressure Level | 49 dBA | quieter than 12.8% of Hybrid/Electric Heat Pump models · At 49 dBA median | Indoor placement check |
| Certification Date | 2024-11-04 | Certified 2024-11-04 | Markets: United States, Canada |
How Do Regional kWh Prices Impact MAWH50D2AKH Over 10 Years?
Using EIA Table 5.6.A benchmarks, Midea MAWH50D2AKH's 855 kWh/yr draw translates to roughly $155/yr on typical US residential bills.
| Jurisdiction (EIA Aug 2026) | Residential Rate | Annual Cost | 10-Yr Operating Spend | 10-Yr Savings vs. 0.92 UEF |
|---|---|---|---|---|
| United States Average | 18.16 ¢/kWh ($0.1816) | $155/yr | $1,553 | $4,776 |
| Hawaii (Highest EIA State) | 47.18 ¢/kWh ($0.4718) | $403/yr | $4,034 | $12,408 |
| California | 29.75 ¢/kWh ($0.2975) | $254/yr | $2,544 | $7,824 |
| Texas | 15.91 ¢/kWh ($0.1591) | $136/yr | $1,360 | $4,184 |
| Washington (Lowest Hydro Tier) | 14.63 ¢/kWh ($0.1463) | $125/yr | $1,251 | $3,848 |
What Should Midea Owners Check in CPSC Recall Logs?
The 2026-11-23 CPSC recall sweep recorded zero brand matches for Midea; run a quick serial-number check to verify age before replacing wear parts. See Serial Number Lookup.
How Do Five Nearby Hybrid/Electric Heat Pump Models Stack Up?
Five alternative Hybrid/Electric Heat Pump units with nearly identical gallon storage and UEF scores are listed below alongside exact efficiency spreads.
| Brand & Model | Type | Vol | FHR | UEF (Δ) | kWh/yr |
|---|---|---|---|---|---|
| 1HVAC ACIQ-50G-HP-WH | Hybrid/Electric Heat Pump | 47 gal | 69 gal | 3.75 (at parity) | 855 |
| ACIQ ACIQ-50G-HP-WH | Hybrid/Electric Heat Pump | 47 gal | 69 gal | 3.75 (at parity) | 855 |
| Bosch TR7000T - 50CA | Hybrid/Electric Heat Pump | 47 gal | 69 gal | 3.75 (at parity) | 855 |
| Custom Comfort CCOHPWH50A | Hybrid/Electric Heat Pump | 47 gal | 69 gal | 3.75 (at parity) | 855 |
| Bosch TR7000T - 50US | Hybrid/Electric Heat Pump | 47 gal | 69 gal | 3.75 (at parity) | 855 |
What Are the Limitations of Midea MAWH50D2AKH and Who Should Not Install It?
Before ordering Midea MAWH50D2AKH (Hybrid/Electric Heat Pump, 3.75 UEF), weigh space clearances, fuel piping, noise (49 dBA), and 2029 rule readiness across three scenarios.
Key Limitations & Exclusions
- Midea MAWH50D2AKH needs >=450 cu ft room air volume or ducting so compressor cooling does not stall recovery.
- Compressor runs near 49 dBA; avoid mounting Midea MAWH50D2AKH directly beside quiet bedrooms.
- Requires condensate drain routing and 240V electrical capacity; verify state DOE HEAR status.
Which Option Fits Your Situation?
Frequently Asked Technical Questions: Midea MAWH50D2AKH
Direct answers to common technical, regulatory, and sizing questions sourced from primary U.S. government and OEM documentation.
Does Midea MAWH50D2AKH pass the May 6, 2029 federal DOE efficiency rule?
Midea MAWH50D2AKH carries a verified 3.75 UEF rating (Pass: +1.45 / +63.0%), ranking #297 of 706 across 706 ENERGY STAR Hybrid/Electric Heat Pump models under 10 CFR 430.32.
What doorway width and ceiling height does Midea MAWH50D2AKH need?
Midea MAWH50D2AKH stands 47.9 in. high with a 18.3 in. diameter; fits standard 72 in. basement/garage clearance; clears 28 in. utility doorway (18.3" d). Leave overhead clearance for dielectric nipples, ball shutoff valves, and top air filters.
What gas pipe size or electrical breaker does Midea MAWH50D2AKH require?
Midea MAWH50D2AKH uses a 240V branch circuit at 24A max (Requires 240V dedicated branch circuit; check panel capacity). Verify main breaker space before replacing a gas tank with an electric hybrid unit.
How much electricity or energy does Midea MAWH50D2AKH cost per year to run?
Rated at 855 kWh/yr, Midea MAWH50D2AKH costs about $155/yr ($1,550 over 10 years) at the August 2026 EIA US average of 18.16 cents/kWh (ranging from $125/yr in Washington hydro tiers up to $403/yr in Hawaii).
Who should NOT install Midea MAWH50D2AKH, and what are its limits?
Midea MAWH50D2AKH (3.75 UEF) is a poor fit for unvented closets under 450 cu ft because compressor intake chills enclosed rooms and runs at 49 dBA.
How many bathrooms or people can Midea MAWH50D2AKH serve at peak demand?
Midea MAWH50D2AKH achieves a 69 gal First Hour Rating (-3 gal vs. 72 gal median). Two back-to-back showers plus a dishwasher run typically call for 55–70 gal FHR.
Are there CPSC safety recalls or serial checks for Midea MAWH50D2AKH?
No active CPSC recalls matched Midea as of 2026-11-23. Always decode the serial tag on Midea MAWH50D2AKH because OEM tank/exchanger warranties span 6–12 years.
What 2026 rebates apply to Midea MAWH50D2AKH, and what peer compares closest?
Federal Section 25C expired Dec 31, 2025 (P.L. 119-21); qualifying HPWHs remain eligible for state DOE HEAR rebates up to $1,750 (<=150% AMI). Closest peer in Hybrid/Electric Heat Pump is 1HVAC ACIQ-50G-HP-WH (3.75 UEF).
Sources
- ENERGY STAR Certified Water Heaters Dataset (Socrata pbpq-swnu) — U.S. EPA & DOE ENERGY STAR, 2026 Live Certified Registry (retrieved 2026-11-23)
- 10 CFR 430.32 — Energy and Water Conservation Standards (Water Heaters & Plumbing Fixtures) — U.S. Department of Energy / eCFR, 2026 eCFR (incl. May 6, 2029 Rule) (retrieved 2026-11-23)
- CPSC SaferProducts.gov Product Recalls REST API — U.S. Consumer Product Safety Commission, 2026 Live Recalls Feed (retrieved 2026-11-23)
- EIA Electric Power Monthly Table 5.6.A — Average Residential Electricity Price by State — U.S. Energy Information Administration (EIA), August 2026 Monthly Release (retrieved 2026-11-23)