Skip to main content
ENERGY STAR water heater model · PD 3543521

Midea US3-RSJ-15/190RDVN3-L3 Water Heater Specifications (3.75 UEF)

Certified at 3.75 UEF across its 47-gallon nominal tank, 69 gal First Hour Rating, Midea US3-RSJ-15/190RDVN3-L3 (Hybrid/Electric Heat Pump, Electric) places #297 of 706 out of 706 ENERGY STAR models (PD 3543521). Its May 6, 2029 10 CFR 430.32 status reads Pass: +1.45 / +63.0%. Rated annual electricity draw of 855 kWh/yr equates to roughly $155/yr ($1,553 over 10 years) at 18.16 cents/kWh. Closest certified alternative is 1HVAC ACIQ-50G-HP-WH (3.75 UEF).

Uniform Energy Factor
3.75 UEF
Cohort UEF Rank
#297 of 706
First Hour Rating
69 gal
Storage Volume
47 gal
Fuel / Type
Electric / Hybrid/Electric Heat Pump
DOE 2029 Rule Status
Pass: +1.45 / +63.0%
Hybrid heat pump water heater upper shroud with brass relief valve and insulated copper risers
Hybrid heat pump water heater upper shroud with brass relief valve and insulated copper risers
Hybrid/Electric Heat Pump UEF Efficiency Distribution (706 Certified Units)Distribution of certified UEF ratings across 706 units in Hybrid/Electric Heat Pump, marking Midea US3-RSJ-15/190RDVN3-L3 at 3.75 UEF.21130201631342031241542.52 UEF4.50 UEFMedian 3.702029 min 2.30Midea US3-RSJ-15/190RDVN3-L3: 3.75
Hybrid/Electric Heat Pump UEF Efficiency Distribution (706 Certified Units). Highlighted pin shows Midea US3-RSJ-15/190RDVN3-L3 relative to the cohort median.
Efficiency comparison & rule summary

Tested at 3.75 UEF, Midea US3-RSJ-15/190RDVN3-L3 places #297 of 706 across 706 certified Hybrid/Electric Heat Pump configurations (+0.05 UEF vs. 3.70 UEF median).

Midea US3-RSJ-15/190RDVN3-L3 clears 10 CFR 430.32(d)(2) Electric >35 to <=55 gal (2.30 UEF) by +1.45 UEF (+63.0% headroom). At EIA August 2026 national rates (18.16 cents/kWh), 855 kWh/yr for Midea US3-RSJ-15/190RDVN3-L3 runs ~$155/yr vs. ~$633/yr for a 0.92 UEF electric tank. Acoustic output is 49 dBA (quieter than 12.8% of Hybrid/Electric Heat Pump models).

State electric sensitivity for Midea US3-RSJ-15/190RDVN3-L3: 10-year operating spend spans $1,251 in Washington (Lowest Hydro Tier) (14.63 cents/kWh) to $4,034 in Hawaii (Highest EIA State) (47.18 cents/kWh).

Closest alternatives to Midea US3-RSJ-15/190RDVN3-L3 include 1HVAC ACIQ-50G-HP-WH (3.75 UEF, at parity) alongside ACIQ ACIQ-50G-HP-WH (3.75 UEF, at parity).

How Complete Are the Certified Metrics for Midea US3-RSJ-15/190RDVN3-L3?

Standing at #297 of 706 among 706 certified Hybrid/Electric Heat Pump heaters, Midea US3-RSJ-15/190RDVN3-L3 brings measurable deltas in recovery, footprint, and energy efficiency.

Certified model attributes compared against 706 ENERGY STAR Hybrid/Electric Heat Pump peers
Specification AttributeCertified ValueCohort Benchmark / DeltaProvenance
Manufacturer / BrandMidea49 certified listingsENERGY STAR PD 3543521
Model NumberUS3-RSJ-15/190RDVN3-L3Draw pattern: Medium-UsageUS3-RSJ-15/190RDVN3-L3
Uniform Energy Factor (UEF)3.75+0.05 UEF vs. 3.70 UEF median10 CFR 430 Test Method
First Hour Rating (FHR)69 gal-3 gal vs. 72 gal median10 CFR 430 Recovery Test
Rated Annual Electricity Use855 kWh/yr-217 kWh/yr vs. 1,072 kWh/yr medianEst. $155/yr @ $0.1816/kWh (EIA US Avg)
Thermal Recovery Efficiency430%+1.0 pts vs. 429.0% medianENERGY STAR Dataset
Physical Envelope (H x Dia)47.9" H x 18.3" DFits standard 72 in. basement/garage clearance; clears 28 in. utility doorway (18.3" D)Doorway & ceiling check
Electrical Circuit Requirements240 V / 24 A maxRequires 240V dedicated branch circuit; check panel capacityNEC / Branch circuit check
Heat Pump Refrigerant & GWPR-134a (GWP:1430)Check regional AIM Act phase-down transitionEPA AIM Act Compliance
Sound Pressure Level49 dBAquieter than 12.8% of Hybrid/Electric Heat Pump models · At 49 dBA medianIndoor placement check
Certification Date2024-11-04Certified 2024-11-04Markets: United States, Canada

What Is the Projected Utility Bill for US3-RSJ-15/190RDVN3-L3 by State?

At 855 kWh/yr, Midea US3-RSJ-15/190RDVN3-L3 averages about $155/yr across US households—see 10-year payback spreads versus 0.92 UEF resistance tanks.

Estimated Annual Electricity Cost by State Rate (855 kWh/yr)Projected annual electricity spend across five benchmark EIA August 2026 residential electric tiers.United States Average$155.00/yrHawaii$403.00/yrCalifornia$254.00/yrTexas$136.00/yrWashington$125.00/yr
Projected annual electricity spend across five benchmark EIA August 2026 residential electric tiers.
Estimated electricity cost and 10-year spend across benchmark states
Jurisdiction (EIA Aug 2026)Residential RateAnnual Cost10-Yr Operating Spend10-Yr Savings vs. 0.92 UEF
United States Average 18.16 ¢/kWh ($0.1816) $155/yr $1,553 $4,776
Hawaii (Highest EIA State) 47.18 ¢/kWh ($0.4718) $403/yr $4,034 $12,408
California 29.75 ¢/kWh ($0.2975) $254/yr $2,544 $7,824
Texas 15.91 ¢/kWh ($0.1591) $136/yr $1,360 $4,184
Washington (Lowest Hydro Tier) 14.63 ¢/kWh ($0.1463) $125/yr $1,251 $3,848
Estimated electricity spend (855 kWh/yr)

Condensing Gas Tankless vs. Storage Tank Flow Path & Gas Supply Engineering schematic contrasting 199,000 BTU/h condensing tankless piping (3/4 in. gas supply, Category IV PVC vent, condensate drain) against a 40,000 BTU/h atmospheric tank. Condensing Gas Tankless (0.91–0.96 UEF) Secondary HX Cat IV PVC Vent Cold In Hot Out 3/4"–1" Gas 199K BTU/h Condensate Atmospheric Storage Tank (0.58–0.65 UEF) Type B Flue Anode Rod 40K BTU/h 1/2" Gas Up to 100 ft T&P 150 psi 50–85 gal FHR Reserve | 8–12 yr life
Technical comparison: condensing gas tankless units require 3/4 in.–1 in. IFGC Table 402.4 gas supply and Category IV condensate drainage, while atmospheric tanks run on 1/2 in. lines.

Are Midea Models Affected by Current CPSC Notices?

Zero brand-level CPSC hazard notices matched Midea in our 2026-11-23 feed; decode your water heater's serial number below to confirm warranty status. See Serial Number Lookup.

Which 5 Models Offer Similar Output to US3-RSJ-15/190RDVN3-L3?

Ordered by minimal capacity and UEF spread relative to Midea US3-RSJ-15/190RDVN3-L3, these five certified peers give direct replacement benchmarks.

5 closest certified peers matched by equipment class, storage volume, and efficiency rating
Brand & ModelTypeVolFHRUEF (Δ)kWh/yr
1HVAC ACIQ-50G-HP-WH Hybrid/Electric Heat Pump 47 gal 69 gal 3.75 (at parity) 855
ACIQ ACIQ-50G-HP-WH Hybrid/Electric Heat Pump 47 gal 69 gal 3.75 (at parity) 855
Bosch TR7000T - 50CA Hybrid/Electric Heat Pump 47 gal 69 gal 3.75 (at parity) 855
Custom Comfort CCOHPWH50A Hybrid/Electric Heat Pump 47 gal 69 gal 3.75 (at parity) 855
Bosch TR7000T - 50US Hybrid/Electric Heat Pump 47 gal 69 gal 3.75 (at parity) 855

What Are the Limitations of Midea US3-RSJ-15/190RDVN3-L3 and Who Should Not Install It?

Before ordering Midea US3-RSJ-15/190RDVN3-L3 (Hybrid/Electric Heat Pump, 3.75 UEF), weigh space clearances, fuel piping, noise (49 dBA), and 2029 rule readiness across three scenarios.

Key Limitations & Exclusions

  • Midea US3-RSJ-15/190RDVN3-L3 needs >=450 cu ft room air volume or ducting so compressor cooling does not stall recovery.
  • Compressor runs near 49 dBA; avoid mounting Midea US3-RSJ-15/190RDVN3-L3 directly beside quiet bedrooms.
  • Requires condensate drain routing and 240V electrical capacity; verify state DOE HEAR status.

Which Option Fits Your Situation?

High Electric Rate States Choosing Midea US3-RSJ-15/190RDVN3-L3 Strong Fit — 3.75 UEF trims electric use ~75% vs 0.92 UEF tanks.
Open Basement or Garage (>=450 cu ft) Strong Fit — Ample ambient air sustains heat-pump-only efficiency.
Small Interior Closet (<300 cu ft) Caution — Add duct kit or compare 1HVAC ACIQ-50G-HP-WH footprint.

Practical Specs & Code Questions for Midea US3-RSJ-15/190RDVN3-L3

Direct answers to common technical, regulatory, and sizing questions sourced from primary U.S. government and OEM documentation.

Does Midea US3-RSJ-15/190RDVN3-L3 pass the May 6, 2029 federal DOE efficiency rule?

Midea US3-RSJ-15/190RDVN3-L3 carries a verified 3.75 UEF rating (Pass: +1.45 / +63.0%), ranking #297 of 706 across 706 ENERGY STAR Hybrid/Electric Heat Pump models under 10 CFR 430.32.

What doorway width and ceiling height does Midea US3-RSJ-15/190RDVN3-L3 need?

Midea US3-RSJ-15/190RDVN3-L3 stands 47.9 in. high with a 18.3 in. diameter; fits standard 72 in. basement/garage clearance; clears 28 in. utility doorway (18.3" d). Leave overhead clearance for dielectric nipples, ball shutoff valves, and top air filters.

What gas pipe size or electrical breaker does Midea US3-RSJ-15/190RDVN3-L3 require?

Midea US3-RSJ-15/190RDVN3-L3 uses a 240V branch circuit at 24A max (Requires 240V dedicated branch circuit; check panel capacity). Verify main breaker space before replacing a gas tank with an electric hybrid unit.

How much electricity or energy does Midea US3-RSJ-15/190RDVN3-L3 cost per year to run?

Rated at 855 kWh/yr, Midea US3-RSJ-15/190RDVN3-L3 costs about $155/yr ($1,550 over 10 years) at the August 2026 EIA US average of 18.16 cents/kWh (ranging from $125/yr in Washington hydro tiers up to $403/yr in Hawaii).

Who should NOT install Midea US3-RSJ-15/190RDVN3-L3, and what are its limits?

Midea US3-RSJ-15/190RDVN3-L3 (3.75 UEF) is a poor fit for unvented closets under 450 cu ft because compressor intake chills enclosed rooms and runs at 49 dBA.

How many bathrooms or people can Midea US3-RSJ-15/190RDVN3-L3 serve at peak demand?

Midea US3-RSJ-15/190RDVN3-L3 achieves a 69 gal First Hour Rating (-3 gal vs. 72 gal median). Two back-to-back showers plus a dishwasher run typically call for 55–70 gal FHR.

Are there CPSC safety recalls or serial checks for Midea US3-RSJ-15/190RDVN3-L3?

No active CPSC recalls matched Midea as of 2026-11-23. Always decode the serial tag on Midea US3-RSJ-15/190RDVN3-L3 because OEM tank/exchanger warranties span 6–12 years.

What 2026 rebates apply to Midea US3-RSJ-15/190RDVN3-L3, and what peer compares closest?

Federal Section 25C expired Dec 31, 2025 (P.L. 119-21); qualifying HPWHs remain eligible for state DOE HEAR rebates up to $1,750 (<=150% AMI). Closest peer in Hybrid/Electric Heat Pump is 1HVAC ACIQ-50G-HP-WH (3.75 UEF).

Sources

  1. ENERGY STAR Certified Water Heaters Dataset (Socrata pbpq-swnu) — U.S. EPA & DOE ENERGY STAR, 2026 Live Certified Registry (retrieved 2026-11-23)
  2. 10 CFR 430.32 — Energy and Water Conservation Standards (Water Heaters & Plumbing Fixtures) — U.S. Department of Energy / eCFR, 2026 eCFR (incl. May 6, 2029 Rule) (retrieved 2026-11-23)
  3. CPSC SaferProducts.gov Product Recalls REST API — U.S. Consumer Product Safety Commission, 2026 Live Recalls Feed (retrieved 2026-11-23)
  4. EIA Electric Power Monthly Table 5.6.A — Average Residential Electricity Price by State — U.S. Energy Information Administration (EIA), August 2026 Monthly Release (retrieved 2026-11-23)

Related U.S. Metro Plumbing Benchmarks