Skip to main content
ENERGY STAR water heater model · PD 4682181

Midea US3-RSJ-15/250RDVN3-L4 Water Heater Specifications (4 UEF)

Certified at 4.0 UEF across its 61-gallon nominal tank, 80 gal First Hour Rating, Midea US3-RSJ-15/250RDVN3-L4 (Hybrid/Electric Heat Pump, Electric) places #106 of 706 out of 706 ENERGY STAR models (PD 4682181). Its May 6, 2029 10 CFR 430.32 status reads Pass: +1.50 / +60.0%. Rated annual electricity draw of 1,234 kWh/yr equates to roughly $224/yr ($2,241 over 10 years) at 18.16 cents/kWh. Closest certified alternative is Rinnai REHP65CW* (4.0 UEF).

Uniform Energy Factor
4.0 UEF
Cohort UEF Rank
#106 of 706 (top 19.8%)
First Hour Rating
80 gal
Storage Volume
61 gal
Fuel / Type
Electric / Hybrid/Electric Heat Pump
DOE 2029 Rule Status
Pass: +1.50 / +60.0%
Hybrid heat pump water heater upper shroud with brass relief valve and insulated copper risers
Hybrid heat pump water heater upper shroud with brass relief valve and insulated copper risers
Hybrid/Electric Heat Pump UEF Efficiency Distribution (706 Certified Units)Distribution of certified UEF ratings across 706 units in Hybrid/Electric Heat Pump, marking Midea US3-RSJ-15/250RDVN3-L4 at 4.0 UEF.21130201631342031241542.52 UEF4.50 UEFMedian 3.702029 min 2.50Midea US3-RSJ-15/250RDVN3-L4: 4.00
Hybrid/Electric Heat Pump UEF Efficiency Distribution (706 Certified Units). Highlighted pin shows Midea US3-RSJ-15/250RDVN3-L4 relative to the cohort median.
Efficiency comparison & rule summary

Tested at 4.0 UEF, Midea US3-RSJ-15/250RDVN3-L4 places #106 of 706 across 706 certified Hybrid/Electric Heat Pump configurations (+0.30 UEF vs. 3.70 UEF median).

Midea US3-RSJ-15/250RDVN3-L4 clears 10 CFR 430.32(d)(2) Electric >55 to <=120 gal (2.50 UEF) by +1.50 UEF (+60.0% headroom). At EIA August 2026 national rates (18.16 cents/kWh), 1,234 kWh/yr for Midea US3-RSJ-15/250RDVN3-L4 runs ~$224/yr vs. ~$974/yr for a 0.92 UEF electric tank. Acoustic output is 49 dBA (quieter than 12.8% of Hybrid/Electric Heat Pump models).

State electric sensitivity for Midea US3-RSJ-15/250RDVN3-L4: 10-year operating spend spans $1,805 in Washington (Lowest Hydro Tier) (14.63 cents/kWh) to $5,822 in Hawaii (Highest EIA State) (47.18 cents/kWh).

Closest alternatives to Midea US3-RSJ-15/250RDVN3-L4 include Rinnai REHP65CW* (4.0 UEF, at parity) alongside Navien NWP500S065AUMB (4.03 UEF, delta +0.03).

What Physical and Thermal Ratings Define Midea US3-RSJ-15/250RDVN3-L4?

Positioning at #106 of 706 (top 19.8%) out of 706 Hybrid/Electric Heat Pump peers, Midea US3-RSJ-15/250RDVN3-L4 pairs measured UEF performance with specific clearance and wiring rules.

Certified model attributes compared against 706 ENERGY STAR Hybrid/Electric Heat Pump peers
Specification AttributeCertified ValueCohort Benchmark / DeltaProvenance
Manufacturer / BrandMidea49 certified listingsENERGY STAR PD 4682181
Model NumberUS3-RSJ-15/250RDVN3-L4Draw pattern: High-UsageUS3-RSJ-15/250RDVN3-L4
Uniform Energy Factor (UEF)4.0+0.30 UEF vs. 3.70 UEF median10 CFR 430 Test Method
First Hour Rating (FHR)80 gal+8 gal vs. 72 gal median10 CFR 430 Recovery Test
Rated Annual Electricity Use1,234 kWh/yr+162 kWh/yr vs. 1,072 kWh/yr medianEst. $224/yr @ $0.1816/kWh (EIA US Avg)
Thermal Recovery Efficiency450%+21.0 pts vs. 429.0% medianENERGY STAR Dataset
Physical Envelope (H x Dia)45.5" H x 21.8" DFits standard 72 in. basement/garage clearance; clears 28 in. utility doorway (21.8" D)Doorway & ceiling check
Electrical Circuit Requirements240 V / 24 A maxRequires 240V dedicated branch circuit; check panel capacityNEC / Branch circuit check
Heat Pump Refrigerant & GWPR-134a (GWP:1430)Check regional AIM Act phase-down transitionEPA AIM Act Compliance
Sound Pressure Level49 dBAquieter than 12.8% of Hybrid/Electric Heat Pump models · At 49 dBA medianIndoor placement check
Certification Date2026-07-31Certified 2026-07-31Markets: United States, Canada

Why Do State Utility Rates Shift US3-RSJ-15/250RDVN3-L4 Running Costs?

Consuming 1,234 kWh annually puts Midea US3-RSJ-15/250RDVN3-L4 near $224/yr at US baseline tariffs, with multi-state EIA comparisons charted below.

Estimated Annual Electricity Cost by State Rate (1,234 kWh/yr)Projected annual electricity spend across five benchmark EIA August 2026 residential electric tiers.United States Average$224.00/yrHawaii$582.00/yrCalifornia$367.00/yrTexas$196.00/yrWashington$181.00/yr
Projected annual electricity spend across five benchmark EIA August 2026 residential electric tiers.
Estimated electricity cost and 10-year spend across benchmark states
Jurisdiction (EIA Aug 2026)Residential RateAnnual Cost10-Yr Operating Spend10-Yr Savings vs. 0.92 UEF
United States Average 18.16 ¢/kWh ($0.1816) $224/yr $2,241 $7,502
Hawaii (Highest EIA State) 47.18 ¢/kWh ($0.4718) $582/yr $5,822 $19,490
California 29.75 ¢/kWh ($0.2975) $367/yr $3,671 $12,290
Texas 15.91 ¢/kWh ($0.1591) $196/yr $1,963 $6,572
Washington (Lowest Hydro Tier) 14.63 ¢/kWh ($0.1463) $181/yr $1,805 $6,044
Estimated electricity spend (1,234 kWh/yr)

Condensing Gas Tankless vs. Storage Tank Flow Path & Gas Supply Engineering schematic contrasting 199,000 BTU/h condensing tankless piping (3/4 in. gas supply, Category IV PVC vent, condensate drain) against a 40,000 BTU/h atmospheric tank. Condensing Gas Tankless (0.91–0.96 UEF) Secondary HX Cat IV PVC Vent Cold In Hot Out 3/4"–1" Gas 199K BTU/h Condensate Atmospheric Storage Tank (0.58–0.65 UEF) Type B Flue Anode Rod 40K BTU/h 1/2" Gas Up to 100 ft T&P 150 psi 50–85 gal FHR Reserve | 8–12 yr life
Technical comparison: condensing gas tankless units require 3/4 in.–1 in. IFGC Table 402.4 gas supply and Category IV condensate drainage, while atmospheric tanks run on 1/2 in. lines.

Have Any Midea Series Triggered CPSC Recalls?

SaferProducts screening on 2026-11-23 returned zero recall matches for Midea; confirm tank age separately using the rating-plate serial pattern. See Serial Number Lookup.

What Are 5 Direct Alternatives to Midea US3-RSJ-15/250RDVN3-L4?

Homeowners cross-shopping Midea US3-RSJ-15/250RDVN3-L4 frequently review these five Hybrid/Electric Heat Pump models ranked closest on capacity and UEF output.

5 closest certified peers matched by equipment class, storage volume, and efficiency rating
Brand & ModelTypeVolFHRUEF (Δ)kWh/yr
Rinnai REHP65CW* Hybrid/Electric Heat Pump 61 gal 80 gal 4.0 (at parity) 1,234
Navien NWP500S065AUMB Hybrid/Electric Heat Pump 61 gal 80 gal 4.03 (+0.03) 1,245
Ariston ARIHPWH-65-T Hybrid/Electric Heat Pump 61 gal 77 gal 4.05 (+0.05) 1,225
Lennox WHHP065T45MD240S**** Hybrid/Electric Heat Pump 61 gal 77 gal 4.05 (+0.05) 1,225
Rinnai REHP65W* Hybrid/Electric Heat Pump 61 gal 80 gal 4.0 (at parity) 1,234

What Installation Caveats Apply Before Buying Midea US3-RSJ-15/250RDVN3-L4?

Even high-UEF units like Midea US3-RSJ-15/250RDVN3-L4 (4.0 UEF) carry physical space, condensate, and fuel-line prerequisites noted below.

Key Limitations & Exclusions

  • Midea US3-RSJ-15/250RDVN3-L4 needs >=450 cu ft room air volume or ducting so compressor cooling does not stall recovery.
  • Compressor runs near 49 dBA; avoid mounting Midea US3-RSJ-15/250RDVN3-L4 directly beside quiet bedrooms.
  • Requires condensate drain routing and 240V electrical capacity; verify state DOE HEAR status.

Which Option Fits Your Situation?

High Electric Rate States Choosing Midea US3-RSJ-15/250RDVN3-L4 Strong Fit — 4.0 UEF trims electric use ~75% vs 0.92 UEF tanks.
Open Basement or Garage (>=450 cu ft) Strong Fit — Ample ambient air sustains heat-pump-only efficiency.
Small Interior Closet (<300 cu ft) Caution — Add duct kit or compare Rinnai REHP65CW* footprint.

Sizing, Efficiency & Recall Answers for Midea US3-RSJ-15/250RDVN3-L4

Direct answers to common technical, regulatory, and sizing questions sourced from primary U.S. government and OEM documentation.

Is Midea US3-RSJ-15/250RDVN3-L4 eligible for continued manufacture past May 6, 2029?

At 4.0 UEF, Midea US3-RSJ-15/250RDVN3-L4 achieves Pass: +1.50 / +60.0% for the 2029 DOE standard and stands #106 of 706 (top 19.8%) against Rinnai REHP65CW* and Navien NWP500S065AUMB.

How tall and wide is Midea US3-RSJ-15/250RDVN3-L4, and what service clearance is needed?

Physical dimensions for Midea US3-RSJ-15/250RDVN3-L4 are 45.5 in. height and 21.8 in. diameter (fits standard 72 in. basement/garage clearance; clears 28 in. utility doorway (21.8" d)); verify stair turns and drain pan width before delivery.

Will Midea US3-RSJ-15/250RDVN3-L4 require upgrading household electrical panels or gas piping?

Midea US3-RSJ-15/250RDVN3-L4 draws 240V at 24A max (Requires 240V dedicated branch circuit; check panel capacity); check whether existing 10/2 AWG 30A copper wiring aligns with nameplate amps.

Is Midea US3-RSJ-15/250RDVN3-L4 economical to operate at 18.16 cents/kWh US electric rates?

Expect roughly $224/yr ($2,240 over 10 years) to power Midea US3-RSJ-15/250RDVN3-L4 at 1,234 kWh/yr under the 18.16 cents/kWh US average (ranging from $181/yr in Washington hydro tiers up to $582/yr in Hawaii).

Which installation bottlenecks limit Midea US3-RSJ-15/250RDVN3-L4?

If ambient room air stays below 40 °F year-round or closet volume falls under 450 cu ft, Midea US3-RSJ-15/250RDVN3-L4 drops into resistance mode more often.

How does Midea US3-RSJ-15/250RDVN3-L4 handle simultaneous showers and laundry?

Delivering 80 gal in the first hour (+8 gal vs. 72 gal median), Midea US3-RSJ-15/250RDVN3-L4 combines 61 gal tank storage with rapid burner/element recovery.

How long is the warranty on Midea US3-RSJ-15/250RDVN3-L4 and how do you decode its serial?

CPSC records show 0 active plumbing recalls for Midea as of 2026-11-23. Confirm install proof and serial manufacture year on Midea US3-RSJ-15/250RDVN3-L4 before calling service.

How do 2026 post-OBBBA rebates affect buying Midea US3-RSJ-15/250RDVN3-L4?

Check state energy office HEAR portals and utility rebates in 2026 since federal 25C ended Dec 31, 2025. Closest peer in Hybrid/Electric Heat Pump is Rinnai REHP65CW* (4.0 UEF).

Sources

  1. ENERGY STAR Certified Water Heaters Dataset (Socrata pbpq-swnu) — U.S. EPA & DOE ENERGY STAR, 2026 Live Certified Registry (retrieved 2026-11-23)
  2. 10 CFR 430.32 — Energy and Water Conservation Standards (Water Heaters & Plumbing Fixtures) — U.S. Department of Energy / eCFR, 2026 eCFR (incl. May 6, 2029 Rule) (retrieved 2026-11-23)
  3. CPSC SaferProducts.gov Product Recalls REST API — U.S. Consumer Product Safety Commission, 2026 Live Recalls Feed (retrieved 2026-11-23)
  4. EIA Electric Power Monthly Table 5.6.A — Average Residential Electricity Price by State — U.S. Energy Information Administration (EIA), August 2026 Monthly Release (retrieved 2026-11-23)

Related U.S. Metro Plumbing Benchmarks