RELIANCE WATER HEATERS RHPCO-45 1**+RXST-50SG 1** Water Heater Specifications (3.52 UEF)

In the 706-unit Hybrid/Electric Heat Pump class, RELIANCE WATER HEATERS RHPCO-45 1**+RXST-50SG 1** (Electric) achieves a certified 3.52 UEF rating across its 46-gallon nominal tank, 70 gal First Hour Rating (rank #441 of 706, PD 4529459) and verifies as Pass: +1.22 / +53.0% for 2029 DOE floors. Rated annual electricity draw of 923 kWh/yr equates to roughly $168/yr ($1,676 over 10 years) at 18.16 cents/kWh. Closest certified alternative is A. O. Smith HPACO-45 1**+AXST-50S 1** (3.52 UEF).

Uniform Energy Factor
3.52 UEF
Cohort UEF Rank
#441 of 706
First Hour Rating
70 gal
Storage Volume
46 gal
Fuel / Type
Electric / Hybrid/Electric Heat Pump
DOE 2029 Rule Status
Pass: +1.22 / +53.0%
Hybrid heat pump water heater upper shroud with brass relief valve and insulated copper risers
Hybrid heat pump water heater upper shroud with brass relief valve and insulated copper risers
Hybrid/Electric Heat Pump UEF Efficiency Distribution (706 Certified Units)Distribution of certified UEF ratings across 706 units in Hybrid/Electric Heat Pump, marking RELIANCE WATER HEATERS RHPCO-45 1**+RXST-50SG 1** at 3.52 UEF.21130201631342031241542.52 UEF4.50 UEFMedian 3.702029 min 2.30RELIANCE WATER HEATERS RHPCO-45 1**+RXST-50SG 1**: 3.52
Hybrid/Electric Heat Pump UEF Efficiency Distribution (706 Certified Units). Highlighted pin shows RELIANCE WATER HEATERS RHPCO-45 1**+RXST-50SG 1** relative to the cohort median.
Efficiency comparison & rule summary

RELIANCE WATER HEATERS RHPCO-45 1**+RXST-50SG 1** records 3.52 UEF efficiency, putting it #441 of 706 among 706 Hybrid/Electric Heat Pump peers.

10 CFR 430.32(d)(2) compliance: RELIANCE WATER HEATERS RHPCO-45 1**+RXST-50SG 1** exceeds 10 CFR 430.32(d)(2) Electric >35 to <=55 gal (2.30 UEF) by +1.22 UEF (+53.0%). At EIA August 2026 national rates (18.16 cents/kWh), 923 kWh/yr for RELIANCE WATER HEATERS RHPCO-45 1**+RXST-50SG 1** runs ~$168/yr vs. ~$641/yr for a 0.92 UEF electric tank.

State electric sensitivity for RELIANCE WATER HEATERS RHPCO-45 1**+RXST-50SG 1**: 10-year operating spend spans $1,350 in Washington (Lowest Hydro Tier) (14.63 cents/kWh) to $4,355 in Hawaii (Highest EIA State) (47.18 cents/kWh).

Competing options beside RELIANCE WATER HEATERS RHPCO-45 1**+RXST-50SG 1** (3.52 UEF) are A. O. Smith HPACO-45 1**+AXST-50S 1** (3.52 UEF, at parity) and American MHPCO-45 1**+MXST-50S 1** (3.52 UEF, at parity).

Where Does RELIANCE WATER HEATERS RHPCO-45 1**+RXST-50SG 1** Rank Against Peer Hybrid/Electric Heat Pump Units?

Audited against 706 ENERGY STAR Hybrid/Electric Heat Pump listings, RELIANCE WATER HEATERS RHPCO-45 1**+RXST-50SG 1** holds #441 of 706; inspect footprint, circuit load, and efficiency deltas here.

Certified model attributes compared against 706 ENERGY STAR Hybrid/Electric Heat Pump peers
Specification AttributeCertified ValueCohort Benchmark / DeltaProvenance
Manufacturer / BrandRELIANCE WATER HEATERS71 certified listingsENERGY STAR PD 4529459
Model NumberRHPCO-45 1**+RXST-50SG 1**Draw pattern: Medium-UsageRHPCO-45 1**+RXST-50SG 1**
Uniform Energy Factor (UEF)3.52-0.18 UEF vs. 3.70 UEF median10 CFR 430 Test Method
First Hour Rating (FHR)70 gal-2 gal vs. 72 gal median10 CFR 430 Recovery Test
Rated Annual Electricity Use923 kWh/yr-149 kWh/yr vs. 1,072 kWh/yr medianEst. $168/yr @ $0.1816/kWh (EIA US Avg)
Thermal Recovery Efficiency429%At 429.0% medianENERGY STAR Dataset
Physical Envelope (H x Dia)46.6" H x 18" DFits standard 72 in. basement/garage clearance; clears 28 in. utility doorway (18" D)Doorway & ceiling check
Electrical Circuit Requirements240 V / 20.2 A maxRequires 240V dedicated branch circuit; check panel capacityNEC / Branch circuit check
Heat Pump Refrigerant & GWPR-744 (CO₂) (GWP:1 | Lower GWP)Lower-GWP refrigerant alignment (EPA AIM Act)EPA AIM Act Compliance
Certification Date2026-02-25Certified 2026-02-25Markets: United States

How Much Electricity Does RHPCO-45 1**+RXST-50SG 1** Use in Different States?

Estimated at $168/yr nationally (923 kWh/yr), 10-year utility spending for RELIANCE WATER HEATERS RHPCO-45 1**+RXST-50SG 1** shifts sharply between low-rate hydro and coastal grids.

Estimated Annual Electricity Cost by State Rate (923 kWh/yr)Projected annual electricity spend across five benchmark EIA August 2026 residential electric tiers.United States Average$168.00/yrHawaii$435.00/yrCalifornia$275.00/yrTexas$147.00/yrWashington$135.00/yr
Projected annual electricity spend across five benchmark EIA August 2026 residential electric tiers.
Estimated electricity cost and 10-year spend across benchmark states
Jurisdiction (EIA Aug 2026)Residential RateAnnual Cost10-Yr Operating Spend10-Yr Savings vs. 0.92 UEF
United States Average 18.16 ¢/kWh ($0.1816) $168/yr $1,676 $4,736
Hawaii (Highest EIA State) 47.18 ¢/kWh ($0.4718) $435/yr $4,355 $12,305
California 29.75 ¢/kWh ($0.2975) $275/yr $2,746 $7,759
Texas 15.91 ¢/kWh ($0.1591) $147/yr $1,468 $4,149
Washington (Lowest Hydro Tier) 14.63 ¢/kWh ($0.1463) $135/yr $1,350 $3,816
Estimated electricity spend (923 kWh/yr)

Condensing Gas Tankless vs. Storage Tank Flow Path & Gas Supply Engineering schematic contrasting 199,000 BTU/h condensing tankless piping (3/4 in. gas supply, Category IV PVC vent, condensate drain) against a 40,000 BTU/h atmospheric tank. Condensing Gas Tankless (0.91–0.96 UEF) Secondary HX Cat IV PVC Vent Cold In Hot Out 3/4"–1" Gas 199K BTU/h Condensate Atmospheric Storage Tank (0.58–0.65 UEF) Type B Flue Anode Rod 40K BTU/h 1/2" Gas Up to 100 ft T&P 150 psi 50–85 gal FHR Reserve | 8–12 yr life
Technical comparison: condensing gas tankless units require 3/4 in.–1 in. IFGC Table 402.4 gas supply and Category IV condensate drainage, while atmospheric tanks run on 1/2 in. lines.

Does CPSC Flag Any Safety Notices on RELIANCE WATER HEATERS Units?

Checking 2026-11-23 SaferProducts data shows 3 notices mentioning RELIANCE WATER HEATERS; always cross-reference affected serial prefixes before ordering components. See Serial Number Lookup.

3 Brand Recall Notices Found in CPSC Feed — Verify Serial & Model Range
  • Recall #19029 (2018-11-08): A. O. Smith Recalls Ultra-Low NOx Water Heaters Due to Fire Hazard (CPSC Notice)
  • Recall #06002 (2005-10-06): CPSC, A.O. Smith Announce Recall of Water Heaters (CPSC Notice)
  • Recall #04128 (2004-04-28): CPSC, White-Rodgers Announce Recall of LP and Convertible Gas Water Heater Temperature Controls (CPSC Notice)

Which Competing Hybrid/Electric Heat Pump Models Compare Closest to RHPCO-45 1**+RXST-50SG 1**?

Compare five nearby ENERGY STAR Hybrid/Electric Heat Pump options matched closely to RELIANCE WATER HEATERS RHPCO-45 1**+RXST-50SG 1**'s gallon capacity and 3.52 UEF efficiency.

5 closest certified peers matched by equipment class, storage volume, and efficiency rating
Brand & ModelTypeVolFHRUEF (Δ)kWh/yr
A. O. Smith HPACO-45 1**+AXST-50S 1** Hybrid/Electric Heat Pump 46 gal 70 gal 3.52 (at parity) 923
American MHPCO-45 1**+MXST-50S 1** Hybrid/Electric Heat Pump 46 gal 70 gal 3.52 (at parity) 923
Giant GTHPCO-45 1**+GTXST-50S 1** Hybrid/Electric Heat Pump 46 gal 70 gal 3.52 (at parity) 923
GSW WATER HEATERS GHPCO-45 1**+GXST-50S 1** Hybrid/Electric Heat Pump 46 gal 70 gal 3.52 (at parity) 923
A. O. Smith HPACO-45 1**+AXST-50STTP 1** Hybrid/Electric Heat Pump 46 gal 70 gal 3.52 (at parity) 923

When Should Homeowners Skip RELIANCE WATER HEATERS RHPCO-45 1**+RXST-50SG 1** (Hybrid/Electric Heat Pump)?

Check RELIANCE WATER HEATERS RHPCO-45 1**+RXST-50SG 1**'s mechanical constraints—including utility space, Electric capacity, and Pass: +1.22 / +53.0% status—against typical residential installations.

Key Limitations & Exclusions

  • RELIANCE WATER HEATERS RHPCO-45 1**+RXST-50SG 1** needs >=450 cu ft room air volume or ducting so compressor cooling does not stall recovery.
  • Compressor runs near 49 dBA; avoid mounting RELIANCE WATER HEATERS RHPCO-45 1**+RXST-50SG 1** directly beside quiet bedrooms.
  • Requires condensate drain routing and 240V electrical capacity; verify state DOE HEAR status.

Which Option Fits Your Situation?

High Electric Rate States Choosing RELIANCE WATER HEATERS RHPCO-45 1**+RXST-50SG 1** Strong Fit — 3.52 UEF trims electric use ~75% vs 0.92 UEF tanks.
Open Basement or Garage (>=450 cu ft) Strong Fit — Ample ambient air sustains heat-pump-only efficiency.
Small Interior Closet (<300 cu ft) Caution — Add duct kit or compare A. O. Smith HPACO-45 1**+AXST-50S 1** footprint.

Common Homeowner Questions for RELIANCE WATER HEATERS RHPCO-45 1**+RXST-50SG 1**

Direct answers to common technical, regulatory, and sizing questions sourced from primary U.S. government and OEM documentation.

Will RELIANCE WATER HEATERS RHPCO-45 1**+RXST-50SG 1** stay compliant after the May 6, 2029 DOE standard takes effect?

Tested at 3.52 UEF, RELIANCE WATER HEATERS RHPCO-45 1**+RXST-50SG 1** shows Pass: +1.22 / +53.0% relative to May 6, 2029 federal DOE limits while placing #441 of 706 among 706 Hybrid/Electric Heat Pump peers like A. O. Smith HPACO-45 1**+AXST-50S 1**.

Will RELIANCE WATER HEATERS RHPCO-45 1**+RXST-50SG 1** fit through a standard utility door and 72-inch basement ceiling?

Measuring 46.6 in. tall by 18 in. diameter, RELIANCE WATER HEATERS RHPCO-45 1**+RXST-50SG 1** notes: fits standard 72 in. basement/garage clearance; clears 28 in. utility doorway (18" d). Reserve space above the jacket for T&P piping and anode removal.

Do existing utility hookups support RELIANCE WATER HEATERS RHPCO-45 1**+RXST-50SG 1** during replacement?

Electrical specs for RELIANCE WATER HEATERS RHPCO-45 1**+RXST-50SG 1** call for 240V at 20.2A max (Requires 240V dedicated branch circuit; check panel capacity). Have a licensed electrician inspect panel load and wire gauge.

What is the estimated 10-year operating spend for RELIANCE WATER HEATERS RHPCO-45 1**+RXST-50SG 1**?

At 18.16 cents/kWh national residential pricing, RELIANCE WATER HEATERS RHPCO-45 1**+RXST-50SG 1**'s 923 kWh/yr draw equals roughly $168 annually or $1,680 across a 10-year horizon (ranging from $135/yr in Washington hydro tiers up to $435/yr in Hawaii).

When is RELIANCE WATER HEATERS RHPCO-45 1**+RXST-50SG 1** a poor fit for a residential replacement?

Avoid placing RELIANCE WATER HEATERS RHPCO-45 1**+RXST-50SG 1** directly next to bedrooms or inside tight <300 cu ft closets without ducting, due to 49 dBA sound and cool exhaust airflow.

What First Hour Rating or flow capacity does RELIANCE WATER HEATERS RHPCO-45 1**+RXST-50SG 1** deliver?

With 70 gal FHR (-2 gal vs. 72 gal median), RELIANCE WATER HEATERS RHPCO-45 1**+RXST-50SG 1** fits larger 3–5 person homes cleanly.

How do you verify manufacturing age and recall status on RELIANCE WATER HEATERS RHPCO-45 1**+RXST-50SG 1**?

CPSC SaferProducts records show 3 brand-level recall notices mentioning RELIANCE WATER HEATERS as of 2026-11-23, including #19029 (2018-11-08). Enter the rating-plate serial into TapAndPipe's Serial Lookup tool to verify production week.

Does RELIANCE WATER HEATERS RHPCO-45 1**+RXST-50SG 1** qualify for DOE HEAR incentives after 25C expired?

After 25C sunset on Dec 31, 2025 under OBBBA, check state DOE HEAR (up to $1,750 income-qualified) and utility rebates for RELIANCE WATER HEATERS RHPCO-45 1**+RXST-50SG 1**. Closest peer in Hybrid/Electric Heat Pump is A. O. Smith HPACO-45 1**+AXST-50S 1** (3.52 UEF).

Sources

  1. ENERGY STAR Certified Water Heaters Dataset (Socrata pbpq-swnu) — U.S. EPA & DOE ENERGY STAR, 2026 Live Certified Registry (retrieved 2026-11-23)
  2. 10 CFR 430.32 — Energy and Water Conservation Standards (Water Heaters & Plumbing Fixtures) — U.S. Department of Energy / eCFR, 2026 eCFR (incl. May 6, 2029 Rule) (retrieved 2026-11-23)
  3. CPSC SaferProducts.gov Product Recalls REST API — U.S. Consumer Product Safety Commission, 2026 Live Recalls Feed (retrieved 2026-11-23)
  4. EIA Electric Power Monthly Table 5.6.A — Average Residential Electricity Price by State — U.S. Energy Information Administration (EIA), August 2026 Monthly Release (retrieved 2026-11-23)

Related U.S. Metro Plumbing Benchmarks