RELIANCE WATER HEATERS RHPCO-45 1**+RXST-80G 1** Water Heater Specifications (3.8 UEF)
With PD 4529433 certification, RELIANCE WATER HEATERS RHPCO-45 1**+RXST-80G 1** (Hybrid/Electric Heat Pump, Electric) achieves a certified 3.8 UEF rating across its 73-gallon nominal tank, 95 gal First Hour Rating, standing #268 of 706 across 706 peers with Pass: +1.30 / +52.0% for May 6, 2029. Rated annual electricity draw of 1,306 kWh/yr equates to roughly $237/yr ($2,372 over 10 years) at 18.16 cents/kWh. Closest certified alternative is A. O. Smith HPACO-45 1**+AXST-80 1** (3.8 UEF).
- Uniform Energy Factor
- 3.8 UEF
- Cohort UEF Rank
- #268 of 706 (top 41.9%)
- First Hour Rating
- 95 gal
- Storage Volume
- 73 gal
- Fuel / Type
- Electric / Hybrid/Electric Heat Pump
- DOE 2029 Rule Status
- Pass: +1.30 / +52.0%

ENERGY STAR certification places RELIANCE WATER HEATERS RHPCO-45 1**+RXST-80G 1** at 3.8 UEF (#268 of 706; +0.10 UEF vs. 3.70 UEF median) in Hybrid/Electric Heat Pump.
May 6, 2029 readiness: RELIANCE WATER HEATERS RHPCO-45 1**+RXST-80G 1** stands +1.30 UEF (+52.0%) relative to 10 CFR 430.32(d)(2) Electric >55 to <=120 gal (2.50 UEF). At EIA August 2026 national rates (18.16 cents/kWh), 1,306 kWh/yr for RELIANCE WATER HEATERS RHPCO-45 1**+RXST-80G 1** runs ~$237/yr vs. ~$980/yr for a 0.92 UEF electric tank.
State electric sensitivity for RELIANCE WATER HEATERS RHPCO-45 1**+RXST-80G 1**: 10-year operating spend spans $1,911 in Washington (Lowest Hydro Tier) (14.63 cents/kWh) to $6,162 in Hawaii (Highest EIA State) (47.18 cents/kWh).
In the Hybrid/Electric Heat Pump tier, A. O. Smith HPACO-45 1**+AXST-80 1** (3.8 UEF, at parity) and American MHPCO-45 1**+MXST-80 1** (3.8 UEF, at parity) bracket RELIANCE WATER HEATERS RHPCO-45 1**+RXST-80G 1**.
What Physical and Thermal Ratings Define RELIANCE WATER HEATERS RHPCO-45 1**+RXST-80G 1**?
Positioning at #268 of 706 (top 41.9%) out of 706 Hybrid/Electric Heat Pump peers, RELIANCE WATER HEATERS RHPCO-45 1**+RXST-80G 1** pairs measured UEF performance with specific clearance and wiring rules.
| Specification Attribute | Certified Value | Cohort Benchmark / Delta | Provenance |
|---|---|---|---|
| Manufacturer / Brand | RELIANCE WATER HEATERS | 71 certified listings | ENERGY STAR PD 4529433 |
| Model Number | RHPCO-45 1**+RXST-80G 1** | Draw pattern: High-Usage | RHPCO-45 1**+RXST-80G 1** |
| Uniform Energy Factor (UEF) | 3.8 | +0.10 UEF vs. 3.70 UEF median | 10 CFR 430 Test Method |
| First Hour Rating (FHR) | 95 gal | +23 gal vs. 72 gal median | 10 CFR 430 Recovery Test |
| Rated Annual Electricity Use | 1,306 kWh/yr | +234 kWh/yr vs. 1,072 kWh/yr median | Est. $237/yr @ $0.1816/kWh (EIA US Avg) |
| Thermal Recovery Efficiency | 423% | -6.0 pts vs. 429.0% median | ENERGY STAR Dataset |
| Physical Envelope (H x Dia) | 58" H x 20" D | Fits standard 72 in. basement/garage clearance; clears 28 in. utility doorway (20" D) | Doorway & ceiling check |
| Electrical Circuit Requirements | 240 V / 20.2 A max | Requires 240V dedicated branch circuit; check panel capacity | NEC / Branch circuit check |
| Heat Pump Refrigerant & GWP | R-744 (CO₂) (GWP:1 | Lower GWP) | Lower-GWP refrigerant alignment (EPA AIM Act) | EPA AIM Act Compliance |
| Certification Date | 2026-02-25 | Certified 2026-02-25 | Markets: United States |
Why Do State Utility Rates Shift RHPCO-45 1**+RXST-80G 1** Running Costs?
Consuming 1,306 kWh annually puts RELIANCE WATER HEATERS RHPCO-45 1**+RXST-80G 1** near $237/yr at US baseline tariffs, with multi-state EIA comparisons charted below.
| Jurisdiction (EIA Aug 2026) | Residential Rate | Annual Cost | 10-Yr Operating Spend | 10-Yr Savings vs. 0.92 UEF |
|---|---|---|---|---|
| United States Average | 18.16 ¢/kWh ($0.1816) | $237/yr | $2,372 | $7,424 |
| Hawaii (Highest EIA State) | 47.18 ¢/kWh ($0.4718) | $616/yr | $6,162 | $19,287 |
| California | 29.75 ¢/kWh ($0.2975) | $389/yr | $3,885 | $12,162 |
| Texas | 15.91 ¢/kWh ($0.1591) | $208/yr | $2,078 | $6,504 |
| Washington (Lowest Hydro Tier) | 14.63 ¢/kWh ($0.1463) | $191/yr | $1,911 | $5,981 |
Have Any RELIANCE WATER HEATERS Series Triggered CPSC Recalls?
SaferProducts records retrieved 2026-11-23 list 3 brand notices under RELIANCE WATER HEATERS; inspect model coverage dates prior to valve or anode service. See Serial Number Lookup.
- Recall #19029 (2018-11-08): A. O. Smith Recalls Ultra-Low NOx Water Heaters Due to Fire Hazard (CPSC Notice)
- Recall #06002 (2005-10-06): CPSC, A.O. Smith Announce Recall of Water Heaters (CPSC Notice)
- Recall #04128 (2004-04-28): CPSC, White-Rodgers Announce Recall of LP and Convertible Gas Water Heater Temperature Controls (CPSC Notice)
What Are 5 Direct Alternatives to RELIANCE WATER HEATERS RHPCO-45 1**+RXST-80G 1**?
Homeowners cross-shopping RELIANCE WATER HEATERS RHPCO-45 1**+RXST-80G 1** frequently review these five Hybrid/Electric Heat Pump models ranked closest on capacity and UEF output.
| Brand & Model | Type | Vol | FHR | UEF (Δ) | kWh/yr |
|---|---|---|---|---|---|
| A. O. Smith HPACO-45 1**+AXST-80 1** | Hybrid/Electric Heat Pump | 73 gal | 95 gal | 3.8 (at parity) | 1,306 |
| American MHPCO-45 1**+MXST-80 1** | Hybrid/Electric Heat Pump | 73 gal | 95 gal | 3.8 (at parity) | 1,306 |
| Giant GTHPCO-45 1**+GTXST-80 1** | Hybrid/Electric Heat Pump | 73 gal | 95 gal | 3.8 (at parity) | 1,306 |
| GSW WATER HEATERS GHPCO-45 1**+GXST-80 1** | Hybrid/Electric Heat Pump | 73 gal | 95 gal | 3.8 (at parity) | 1,306 |
| A. O. Smith HPACO-45 1**+AXST-80TTP 1** | Hybrid/Electric Heat Pump | 73 gal | 95 gal | 3.8 (at parity) | 1,306 |
What Installation Caveats Apply Before Buying RELIANCE WATER HEATERS RHPCO-45 1**+RXST-80G 1**?
Even high-UEF units like RELIANCE WATER HEATERS RHPCO-45 1**+RXST-80G 1** (3.8 UEF) carry physical space, condensate, and fuel-line prerequisites noted below.
Key Limitations & Exclusions
- RELIANCE WATER HEATERS RHPCO-45 1**+RXST-80G 1** needs >=450 cu ft room air volume or ducting so compressor cooling does not stall recovery.
- Compressor runs near 49 dBA; avoid mounting RELIANCE WATER HEATERS RHPCO-45 1**+RXST-80G 1** directly beside quiet bedrooms.
- Requires condensate drain routing and 240V electrical capacity; verify state DOE HEAR status.
Which Option Fits Your Situation?
Sizing, Efficiency & Recall Answers for RELIANCE WATER HEATERS RHPCO-45 1**+RXST-80G 1**
Direct answers to common technical, regulatory, and sizing questions sourced from primary U.S. government and OEM documentation.
Is RELIANCE WATER HEATERS RHPCO-45 1**+RXST-80G 1** eligible for continued manufacture past May 6, 2029?
At 3.8 UEF, RELIANCE WATER HEATERS RHPCO-45 1**+RXST-80G 1** achieves Pass: +1.30 / +52.0% for the 2029 DOE standard and stands #268 of 706 (top 41.9%) against A. O. Smith HPACO-45 1**+AXST-80 1** and American MHPCO-45 1**+MXST-80 1**.
How tall and wide is RELIANCE WATER HEATERS RHPCO-45 1**+RXST-80G 1**, and what service clearance is needed?
Physical dimensions for RELIANCE WATER HEATERS RHPCO-45 1**+RXST-80G 1** are 58 in. height and 20 in. diameter (fits standard 72 in. basement/garage clearance; clears 28 in. utility doorway (20" d)); verify stair turns and drain pan width before delivery.
Will RELIANCE WATER HEATERS RHPCO-45 1**+RXST-80G 1** require upgrading household electrical panels or gas piping?
RELIANCE WATER HEATERS RHPCO-45 1**+RXST-80G 1** draws 240V at 20.2A max (Requires 240V dedicated branch circuit; check panel capacity); check whether existing 10/2 AWG 30A copper wiring aligns with nameplate amps.
Is RELIANCE WATER HEATERS RHPCO-45 1**+RXST-80G 1** economical to operate at 18.16 cents/kWh US electric rates?
Expect roughly $237/yr ($2,370 over 10 years) to power RELIANCE WATER HEATERS RHPCO-45 1**+RXST-80G 1** at 1,306 kWh/yr under the 18.16 cents/kWh US average (ranging from $191/yr in Washington hydro tiers up to $616/yr in Hawaii).
Which installation bottlenecks limit RELIANCE WATER HEATERS RHPCO-45 1**+RXST-80G 1**?
If ambient room air stays below 40 °F year-round or closet volume falls under 450 cu ft, RELIANCE WATER HEATERS RHPCO-45 1**+RXST-80G 1** drops into resistance mode more often.
How does RELIANCE WATER HEATERS RHPCO-45 1**+RXST-80G 1** handle simultaneous showers and laundry?
Delivering 95 gal in the first hour (+23 gal vs. 72 gal median), RELIANCE WATER HEATERS RHPCO-45 1**+RXST-80G 1** combines 73 gal tank storage with rapid burner/element recovery.
How long is the warranty on RELIANCE WATER HEATERS RHPCO-45 1**+RXST-80G 1** and how do you decode its serial?
CPSC SaferProducts records show 3 brand-level recall notices mentioning RELIANCE WATER HEATERS as of 2026-11-23, including #19029 (2018-11-08). Enter the rating-plate serial into TapAndPipe's Serial Lookup tool to verify production week.
How do 2026 post-OBBBA rebates affect buying RELIANCE WATER HEATERS RHPCO-45 1**+RXST-80G 1**?
Check state energy office HEAR portals and utility rebates in 2026 since federal 25C ended Dec 31, 2025. Closest peer in Hybrid/Electric Heat Pump is A. O. Smith HPACO-45 1**+AXST-80 1** (3.8 UEF).
Sources
- ENERGY STAR Certified Water Heaters Dataset (Socrata pbpq-swnu) — U.S. EPA & DOE ENERGY STAR, 2026 Live Certified Registry (retrieved 2026-11-23)
- 10 CFR 430.32 — Energy and Water Conservation Standards (Water Heaters & Plumbing Fixtures) — U.S. Department of Energy / eCFR, 2026 eCFR (incl. May 6, 2029 Rule) (retrieved 2026-11-23)
- CPSC SaferProducts.gov Product Recalls REST API — U.S. Consumer Product Safety Commission, 2026 Live Recalls Feed (retrieved 2026-11-23)
- EIA Electric Power Monthly Table 5.6.A — Average Residential Electricity Price by State — U.S. Energy Information Administration (EIA), August 2026 Monthly Release (retrieved 2026-11-23)