Skip to main content
ENERGY STAR water heater model · PD 4572769

Richmond 10CE65-HP5U15 Water Heater Specifications (3.55 UEF)

In the 706-unit Hybrid/Electric Heat Pump class, Richmond 10CE65-HP5U15 (Electric) achieves a certified 3.55 UEF rating across its 59-gallon nominal tank, 54 gal First Hour Rating (rank #414 of 706, PD 4572769) and verifies as Pass: +1.05 / +42.0% for 2029 DOE floors. Rated annual electricity draw of 887 kWh/yr equates to roughly $161/yr ($1,611 over 10 years) at 18.16 cents/kWh. Closest certified alternative is Friedrich PROH65 T2 FD400-15 (3.55 UEF).

Uniform Energy Factor
3.55 UEF
Cohort UEF Rank
#414 of 706
First Hour Rating
54 gal
Storage Volume
59 gal
Fuel / Type
Electric / Hybrid/Electric Heat Pump
DOE 2029 Rule Status
Pass: +1.05 / +42.0%
Hybrid heat pump water heater upper shroud with brass relief valve and insulated copper risers
Hybrid heat pump water heater upper shroud with brass relief valve and insulated copper risers
Hybrid/Electric Heat Pump UEF Efficiency Distribution (706 Certified Units)Distribution of certified UEF ratings across 706 units in Hybrid/Electric Heat Pump, marking Richmond 10CE65-HP5U15 at 3.55 UEF.21130201631342031241542.52 UEF4.50 UEFMedian 3.702029 min 2.50Richmond 10CE65-HP5U15: 3.55
Hybrid/Electric Heat Pump UEF Efficiency Distribution (706 Certified Units). Highlighted pin shows Richmond 10CE65-HP5U15 relative to the cohort median.
Efficiency comparison & rule summary

Richmond 10CE65-HP5U15 records 3.55 UEF efficiency, putting it #414 of 706 among 706 Hybrid/Electric Heat Pump peers.

10 CFR 430.32(d)(2) compliance: Richmond 10CE65-HP5U15 exceeds 10 CFR 430.32(d)(2) Electric >55 to <=120 gal (2.50 UEF) by +1.05 UEF (+42.0%). At EIA August 2026 national rates (18.16 cents/kWh), 887 kWh/yr for Richmond 10CE65-HP5U15 runs ~$161/yr vs. ~$622/yr for a 0.92 UEF electric tank.

State electric sensitivity for Richmond 10CE65-HP5U15: 10-year operating spend spans $1,298 in Washington (Lowest Hydro Tier) (14.63 cents/kWh) to $4,185 in Hawaii (Highest EIA State) (47.18 cents/kWh).

Competing options beside Richmond 10CE65-HP5U15 (3.55 UEF) are Friedrich PROH65 T2 FD400-15 (3.55 UEF, at parity) and Rheem CPROPH65 T2 RH375-15 (3.55 UEF, at parity).

Where Does Richmond 10CE65-HP5U15 Rank Against Peer Hybrid/Electric Heat Pump Units?

Audited against 706 ENERGY STAR Hybrid/Electric Heat Pump listings, Richmond 10CE65-HP5U15 holds #414 of 706; inspect footprint, circuit load, and efficiency deltas here.

Certified model attributes compared against 706 ENERGY STAR Hybrid/Electric Heat Pump peers
Specification AttributeCertified ValueCohort Benchmark / DeltaProvenance
Manufacturer / BrandRichmond80 certified listingsENERGY STAR PD 4572769
Model Number10CE65-HP5U15Draw pattern: Medium-Usage10CE65-HP5U15
Uniform Energy Factor (UEF)3.55-0.15 UEF vs. 3.70 UEF median10 CFR 430 Test Method
First Hour Rating (FHR)54 gal-18 gal vs. 72 gal median10 CFR 430 Recovery Test
Rated Annual Electricity Use887 kWh/yr-185 kWh/yr vs. 1,072 kWh/yr medianEst. $161/yr @ $0.1816/kWh (EIA US Avg)
Thermal Recovery Efficiency407%-22.0 pts vs. 429.0% medianENERGY STAR Dataset
Physical Envelope (H x Dia)64.2" H x 24.3" DVerify 72 in. vertical headroom; clears 28 in. utility doorway (24.3" D)Doorway & ceiling check
Electrical Circuit Requirements240 V / 12 A maxRequires 240V dedicated branch circuit; check panel capacityNEC / Branch circuit check
Heat Pump Refrigerant & GWPR-134a (GWP:1430)Check regional AIM Act phase-down transitionEPA AIM Act Compliance
Certification Date2026-03-24Certified 2026-03-24Markets: Canada

How Much Electricity Does 10CE65-HP5U15 Use in Different States?

Estimated at $161/yr nationally (887 kWh/yr), 10-year utility spending for Richmond 10CE65-HP5U15 shifts sharply between low-rate hydro and coastal grids.

Estimated Annual Electricity Cost by State Rate (887 kWh/yr)Projected annual electricity spend across five benchmark EIA August 2026 residential electric tiers.United States Average$161.00/yrHawaii$418.00/yrCalifornia$264.00/yrTexas$141.00/yrWashington$130.00/yr
Projected annual electricity spend across five benchmark EIA August 2026 residential electric tiers.
Estimated electricity cost and 10-year spend across benchmark states
Jurisdiction (EIA Aug 2026)Residential RateAnnual Cost10-Yr Operating Spend10-Yr Savings vs. 0.92 UEF
United States Average 18.16 ¢/kWh ($0.1816) $161/yr $1,611 $4,605
Hawaii (Highest EIA State) 47.18 ¢/kWh ($0.4718) $418/yr $4,185 $11,965
California 29.75 ¢/kWh ($0.2975) $264/yr $2,639 $7,545
Texas 15.91 ¢/kWh ($0.1591) $141/yr $1,411 $4,035
Washington (Lowest Hydro Tier) 14.63 ¢/kWh ($0.1463) $130/yr $1,298 $3,710
Estimated electricity spend (887 kWh/yr)

Condensing Gas Tankless vs. Storage Tank Flow Path & Gas Supply Engineering schematic contrasting 199,000 BTU/h condensing tankless piping (3/4 in. gas supply, Category IV PVC vent, condensate drain) against a 40,000 BTU/h atmospheric tank. Condensing Gas Tankless (0.91–0.96 UEF) Secondary HX Cat IV PVC Vent Cold In Hot Out 3/4"–1" Gas 199K BTU/h Condensate Atmospheric Storage Tank (0.58–0.65 UEF) Type B Flue Anode Rod 40K BTU/h 1/2" Gas Up to 100 ft T&P 150 psi 50–85 gal FHR Reserve | 8–12 yr life
Technical comparison: condensing gas tankless units require 3/4 in.–1 in. IFGC Table 402.4 gas supply and Category IV condensate drainage, while atmospheric tanks run on 1/2 in. lines.

Does CPSC Flag Any Safety Notices on Richmond Units?

No open CPSC recall alerts appeared for Richmond as of 2026-11-23; you can still decode exact manufacture month and warranty window below. See Serial Number Lookup.

Which Competing Hybrid/Electric Heat Pump Models Compare Closest to 10CE65-HP5U15?

Compare five nearby ENERGY STAR Hybrid/Electric Heat Pump options matched closely to Richmond 10CE65-HP5U15's gallon capacity and 3.55 UEF efficiency.

5 closest certified peers matched by equipment class, storage volume, and efficiency rating
Brand & ModelTypeVolFHRUEF (Δ)kWh/yr
Friedrich PROH65 T2 FD400-15 Hybrid/Electric Heat Pump 59 gal 54 gal 3.55 (at parity) 887
Rheem CPROPH65 T2 RH375-15 Hybrid/Electric Heat Pump 59 gal 54 gal 3.55 (at parity) 887
Ruud PROUH65 T2 CD400-15 Hybrid/Electric Heat Pump 59 gal 54 gal 3.55 (at parity) 887
A. O. Smith HPACO-45 1**+AXST-66 1** Hybrid/Electric Heat Pump 60 gal 82 gal 3.7 (+0.15) 1,341
Rheem CPROPH65 T2 RH400-15 Hybrid/Electric Heat Pump 59 gal 54 gal 3.55 (at parity) 887

What Are the Limitations of Richmond 10CE65-HP5U15 and Who Should Not Install It?

Before ordering Richmond 10CE65-HP5U15 (Hybrid/Electric Heat Pump, 3.55 UEF), weigh space clearances, fuel piping, noise (standard dBA), and 2029 rule readiness across three scenarios.

Key Limitations & Exclusions

  • Richmond 10CE65-HP5U15 needs >=450 cu ft room air volume or ducting so compressor cooling does not stall recovery.
  • Compressor runs near 49 dBA; avoid mounting Richmond 10CE65-HP5U15 directly beside quiet bedrooms.
  • Requires condensate drain routing and 240V electrical capacity; verify state DOE HEAR status.

Which Option Fits Your Situation?

High Electric Rate States Choosing Richmond 10CE65-HP5U15 Strong Fit — 3.55 UEF trims electric use ~75% vs 0.92 UEF tanks.
Open Basement or Garage (>=450 cu ft) Strong Fit — Ample ambient air sustains heat-pump-only efficiency.
Small Interior Closet (<300 cu ft) Caution — Add duct kit or compare Friedrich PROH65 T2 FD400-15 footprint.

Common Homeowner Questions for Richmond 10CE65-HP5U15

Direct answers to common technical, regulatory, and sizing questions sourced from primary U.S. government and OEM documentation.

Does Richmond 10CE65-HP5U15 pass the May 6, 2029 federal DOE efficiency rule?

Richmond 10CE65-HP5U15 carries a verified 3.55 UEF rating (Pass: +1.05 / +42.0%), ranking #414 of 706 across 706 ENERGY STAR Hybrid/Electric Heat Pump models under 10 CFR 430.32.

What doorway width and ceiling height does Richmond 10CE65-HP5U15 need?

Richmond 10CE65-HP5U15 stands 64.2 in. high with a 24.3 in. diameter; verify 72 in. vertical headroom; clears 28 in. utility doorway (24.3" d). Leave overhead clearance for dielectric nipples, ball shutoff valves, and top air filters.

What gas pipe size or electrical breaker does Richmond 10CE65-HP5U15 require?

Richmond 10CE65-HP5U15 uses a 240V branch circuit at 12A max (Requires 240V dedicated branch circuit; check panel capacity). Verify main breaker space before replacing a gas tank with an electric hybrid unit.

How much electricity or energy does Richmond 10CE65-HP5U15 cost per year to run?

Rated at 887 kWh/yr, Richmond 10CE65-HP5U15 costs about $161/yr ($1,610 over 10 years) at the August 2026 EIA US average of 18.16 cents/kWh (ranging from $130/yr in Washington hydro tiers up to $418/yr in Hawaii).

Who should NOT install Richmond 10CE65-HP5U15, and what are its limits?

Richmond 10CE65-HP5U15 (3.55 UEF) is a poor fit for unvented closets under 450 cu ft because compressor intake chills enclosed rooms and runs at 49 dBA.

How many bathrooms or people can Richmond 10CE65-HP5U15 serve at peak demand?

Richmond 10CE65-HP5U15 achieves a 54 gal First Hour Rating (-18 gal vs. 72 gal median). Two back-to-back showers plus a dishwasher run typically call for 55–70 gal FHR.

Are there CPSC safety recalls or serial checks for Richmond 10CE65-HP5U15?

No active CPSC recalls matched Richmond as of 2026-11-23. Always decode the serial tag on Richmond 10CE65-HP5U15 because OEM tank/exchanger warranties span 6–12 years.

What 2026 rebates apply to Richmond 10CE65-HP5U15, and what peer compares closest?

Federal Section 25C expired Dec 31, 2025 (P.L. 119-21); qualifying HPWHs remain eligible for state DOE HEAR rebates up to $1,750 (<=150% AMI). Closest peer in Hybrid/Electric Heat Pump is Friedrich PROH65 T2 FD400-15 (3.55 UEF).

Sources

  1. ENERGY STAR Certified Water Heaters Dataset (Socrata pbpq-swnu) — U.S. EPA & DOE ENERGY STAR, 2026 Live Certified Registry (retrieved 2026-11-23)
  2. 10 CFR 430.32 — Energy and Water Conservation Standards (Water Heaters & Plumbing Fixtures) — U.S. Department of Energy / eCFR, 2026 eCFR (incl. May 6, 2029 Rule) (retrieved 2026-11-23)
  3. CPSC SaferProducts.gov Product Recalls REST API — U.S. Consumer Product Safety Commission, 2026 Live Recalls Feed (retrieved 2026-11-23)
  4. EIA Electric Power Monthly Table 5.6.A — Average Residential Electricity Price by State — U.S. Energy Information Administration (EIA), August 2026 Monthly Release (retrieved 2026-11-23)

Related U.S. Metro Plumbing Benchmarks