Richmond 10CE65-HP5U15 Water Heater Specifications (3.55 UEF)
In the 706-unit Hybrid/Electric Heat Pump class, Richmond 10CE65-HP5U15 (Electric) achieves a certified 3.55 UEF rating across its 59-gallon nominal tank, 54 gal First Hour Rating (rank #414 of 706, PD 4572769) and verifies as Pass: +1.05 / +42.0% for 2029 DOE floors. Rated annual electricity draw of 887 kWh/yr equates to roughly $161/yr ($1,611 over 10 years) at 18.16 cents/kWh. Closest certified alternative is Friedrich PROH65 T2 FD400-15 (3.55 UEF).
- Uniform Energy Factor
- 3.55 UEF
- Cohort UEF Rank
- #414 of 706
- First Hour Rating
- 54 gal
- Storage Volume
- 59 gal
- Fuel / Type
- Electric / Hybrid/Electric Heat Pump
- DOE 2029 Rule Status
- Pass: +1.05 / +42.0%

Richmond 10CE65-HP5U15 records 3.55 UEF efficiency, putting it #414 of 706 among 706 Hybrid/Electric Heat Pump peers.
10 CFR 430.32(d)(2) compliance: Richmond 10CE65-HP5U15 exceeds 10 CFR 430.32(d)(2) Electric >55 to <=120 gal (2.50 UEF) by +1.05 UEF (+42.0%). At EIA August 2026 national rates (18.16 cents/kWh), 887 kWh/yr for Richmond 10CE65-HP5U15 runs ~$161/yr vs. ~$622/yr for a 0.92 UEF electric tank.
State electric sensitivity for Richmond 10CE65-HP5U15: 10-year operating spend spans $1,298 in Washington (Lowest Hydro Tier) (14.63 cents/kWh) to $4,185 in Hawaii (Highest EIA State) (47.18 cents/kWh).
Competing options beside Richmond 10CE65-HP5U15 (3.55 UEF) are Friedrich PROH65 T2 FD400-15 (3.55 UEF, at parity) and Rheem CPROPH65 T2 RH375-15 (3.55 UEF, at parity).
Where Does Richmond 10CE65-HP5U15 Rank Against Peer Hybrid/Electric Heat Pump Units?
Audited against 706 ENERGY STAR Hybrid/Electric Heat Pump listings, Richmond 10CE65-HP5U15 holds #414 of 706; inspect footprint, circuit load, and efficiency deltas here.
| Specification Attribute | Certified Value | Cohort Benchmark / Delta | Provenance |
|---|---|---|---|
| Manufacturer / Brand | Richmond | 80 certified listings | ENERGY STAR PD 4572769 |
| Model Number | 10CE65-HP5U15 | Draw pattern: Medium-Usage | 10CE65-HP5U15 |
| Uniform Energy Factor (UEF) | 3.55 | -0.15 UEF vs. 3.70 UEF median | 10 CFR 430 Test Method |
| First Hour Rating (FHR) | 54 gal | -18 gal vs. 72 gal median | 10 CFR 430 Recovery Test |
| Rated Annual Electricity Use | 887 kWh/yr | -185 kWh/yr vs. 1,072 kWh/yr median | Est. $161/yr @ $0.1816/kWh (EIA US Avg) |
| Thermal Recovery Efficiency | 407% | -22.0 pts vs. 429.0% median | ENERGY STAR Dataset |
| Physical Envelope (H x Dia) | 64.2" H x 24.3" D | Verify 72 in. vertical headroom; clears 28 in. utility doorway (24.3" D) | Doorway & ceiling check |
| Electrical Circuit Requirements | 240 V / 12 A max | Requires 240V dedicated branch circuit; check panel capacity | NEC / Branch circuit check |
| Heat Pump Refrigerant & GWP | R-134a (GWP:1430) | Check regional AIM Act phase-down transition | EPA AIM Act Compliance |
| Certification Date | 2026-03-24 | Certified 2026-03-24 | Markets: Canada |
How Much Electricity Does 10CE65-HP5U15 Use in Different States?
Estimated at $161/yr nationally (887 kWh/yr), 10-year utility spending for Richmond 10CE65-HP5U15 shifts sharply between low-rate hydro and coastal grids.
| Jurisdiction (EIA Aug 2026) | Residential Rate | Annual Cost | 10-Yr Operating Spend | 10-Yr Savings vs. 0.92 UEF |
|---|---|---|---|---|
| United States Average | 18.16 ¢/kWh ($0.1816) | $161/yr | $1,611 | $4,605 |
| Hawaii (Highest EIA State) | 47.18 ¢/kWh ($0.4718) | $418/yr | $4,185 | $11,965 |
| California | 29.75 ¢/kWh ($0.2975) | $264/yr | $2,639 | $7,545 |
| Texas | 15.91 ¢/kWh ($0.1591) | $141/yr | $1,411 | $4,035 |
| Washington (Lowest Hydro Tier) | 14.63 ¢/kWh ($0.1463) | $130/yr | $1,298 | $3,710 |
Does CPSC Flag Any Safety Notices on Richmond Units?
No open CPSC recall alerts appeared for Richmond as of 2026-11-23; you can still decode exact manufacture month and warranty window below. See Serial Number Lookup.
Which Competing Hybrid/Electric Heat Pump Models Compare Closest to 10CE65-HP5U15?
Compare five nearby ENERGY STAR Hybrid/Electric Heat Pump options matched closely to Richmond 10CE65-HP5U15's gallon capacity and 3.55 UEF efficiency.
| Brand & Model | Type | Vol | FHR | UEF (Δ) | kWh/yr |
|---|---|---|---|---|---|
| Friedrich PROH65 T2 FD400-15 | Hybrid/Electric Heat Pump | 59 gal | 54 gal | 3.55 (at parity) | 887 |
| Rheem CPROPH65 T2 RH375-15 | Hybrid/Electric Heat Pump | 59 gal | 54 gal | 3.55 (at parity) | 887 |
| Ruud PROUH65 T2 CD400-15 | Hybrid/Electric Heat Pump | 59 gal | 54 gal | 3.55 (at parity) | 887 |
| A. O. Smith HPACO-45 1**+AXST-66 1** | Hybrid/Electric Heat Pump | 60 gal | 82 gal | 3.7 (+0.15) | 1,341 |
| Rheem CPROPH65 T2 RH400-15 | Hybrid/Electric Heat Pump | 59 gal | 54 gal | 3.55 (at parity) | 887 |
What Are the Limitations of Richmond 10CE65-HP5U15 and Who Should Not Install It?
Before ordering Richmond 10CE65-HP5U15 (Hybrid/Electric Heat Pump, 3.55 UEF), weigh space clearances, fuel piping, noise (standard dBA), and 2029 rule readiness across three scenarios.
Key Limitations & Exclusions
- Richmond 10CE65-HP5U15 needs >=450 cu ft room air volume or ducting so compressor cooling does not stall recovery.
- Compressor runs near 49 dBA; avoid mounting Richmond 10CE65-HP5U15 directly beside quiet bedrooms.
- Requires condensate drain routing and 240V electrical capacity; verify state DOE HEAR status.
Which Option Fits Your Situation?
Common Homeowner Questions for Richmond 10CE65-HP5U15
Direct answers to common technical, regulatory, and sizing questions sourced from primary U.S. government and OEM documentation.
Does Richmond 10CE65-HP5U15 pass the May 6, 2029 federal DOE efficiency rule?
Richmond 10CE65-HP5U15 carries a verified 3.55 UEF rating (Pass: +1.05 / +42.0%), ranking #414 of 706 across 706 ENERGY STAR Hybrid/Electric Heat Pump models under 10 CFR 430.32.
What doorway width and ceiling height does Richmond 10CE65-HP5U15 need?
Richmond 10CE65-HP5U15 stands 64.2 in. high with a 24.3 in. diameter; verify 72 in. vertical headroom; clears 28 in. utility doorway (24.3" d). Leave overhead clearance for dielectric nipples, ball shutoff valves, and top air filters.
What gas pipe size or electrical breaker does Richmond 10CE65-HP5U15 require?
Richmond 10CE65-HP5U15 uses a 240V branch circuit at 12A max (Requires 240V dedicated branch circuit; check panel capacity). Verify main breaker space before replacing a gas tank with an electric hybrid unit.
How much electricity or energy does Richmond 10CE65-HP5U15 cost per year to run?
Rated at 887 kWh/yr, Richmond 10CE65-HP5U15 costs about $161/yr ($1,610 over 10 years) at the August 2026 EIA US average of 18.16 cents/kWh (ranging from $130/yr in Washington hydro tiers up to $418/yr in Hawaii).
Who should NOT install Richmond 10CE65-HP5U15, and what are its limits?
Richmond 10CE65-HP5U15 (3.55 UEF) is a poor fit for unvented closets under 450 cu ft because compressor intake chills enclosed rooms and runs at 49 dBA.
How many bathrooms or people can Richmond 10CE65-HP5U15 serve at peak demand?
Richmond 10CE65-HP5U15 achieves a 54 gal First Hour Rating (-18 gal vs. 72 gal median). Two back-to-back showers plus a dishwasher run typically call for 55–70 gal FHR.
Are there CPSC safety recalls or serial checks for Richmond 10CE65-HP5U15?
No active CPSC recalls matched Richmond as of 2026-11-23. Always decode the serial tag on Richmond 10CE65-HP5U15 because OEM tank/exchanger warranties span 6–12 years.
What 2026 rebates apply to Richmond 10CE65-HP5U15, and what peer compares closest?
Federal Section 25C expired Dec 31, 2025 (P.L. 119-21); qualifying HPWHs remain eligible for state DOE HEAR rebates up to $1,750 (<=150% AMI). Closest peer in Hybrid/Electric Heat Pump is Friedrich PROH65 T2 FD400-15 (3.55 UEF).
Sources
- ENERGY STAR Certified Water Heaters Dataset (Socrata pbpq-swnu) — U.S. EPA & DOE ENERGY STAR, 2026 Live Certified Registry (retrieved 2026-11-23)
- 10 CFR 430.32 — Energy and Water Conservation Standards (Water Heaters & Plumbing Fixtures) — U.S. Department of Energy / eCFR, 2026 eCFR (incl. May 6, 2029 Rule) (retrieved 2026-11-23)
- CPSC SaferProducts.gov Product Recalls REST API — U.S. Consumer Product Safety Commission, 2026 Live Recalls Feed (retrieved 2026-11-23)
- EIA Electric Power Monthly Table 5.6.A — Average Residential Electricity Price by State — U.S. Energy Information Administration (EIA), August 2026 Monthly Release (retrieved 2026-11-23)