Rheem CPROPH40 T2 RH350BM Water Heater Specifications (3.5 UEF)
Certified at 3.5 UEF across its 36-gallon nominal tank, 60 gal First Hour Rating, Rheem CPROPH40 T2 RH350BM (Hybrid/Electric Heat Pump, Electric) places #481 of 706 out of 706 ENERGY STAR models (PD 3994201). Its May 6, 2029 10 CFR 430.32 status reads Pass: +1.20 / +52.2%. Rated annual electricity draw of 879 kWh/yr equates to roughly $160/yr ($1,596 over 10 years) at 18.16 cents/kWh. Closest certified alternative is Friedrich PROH40 T2 FD310BM (3.5 UEF).
- Uniform Energy Factor
- 3.5 UEF
- Cohort UEF Rank
- #481 of 706
- First Hour Rating
- 60 gal
- Storage Volume
- 36 gal
- Fuel / Type
- Electric / Hybrid/Electric Heat Pump
- DOE 2029 Rule Status
- Pass: +1.20 / +52.2%

Tested at 3.5 UEF, Rheem CPROPH40 T2 RH350BM places #481 of 706 across 706 certified Hybrid/Electric Heat Pump configurations (-0.20 UEF vs. 3.70 UEF median).
Rheem CPROPH40 T2 RH350BM clears 10 CFR 430.32(d)(2) Electric >35 to <=55 gal (2.30 UEF) by +1.20 UEF (+52.2% headroom). At EIA August 2026 national rates (18.16 cents/kWh), 879 kWh/yr for Rheem CPROPH40 T2 RH350BM runs ~$160/yr vs. ~$607/yr for a 0.92 UEF electric tank.
State electric sensitivity for Rheem CPROPH40 T2 RH350BM: 10-year operating spend spans $1,286 in Washington (Lowest Hydro Tier) (14.63 cents/kWh) to $4,147 in Hawaii (Highest EIA State) (47.18 cents/kWh).
Closest alternatives to Rheem CPROPH40 T2 RH350BM include Friedrich PROH40 T2 FD310BM (3.5 UEF, at parity) alongside Ruud PRO H40 T2 RU310BM (3.5 UEF, at parity).
How Do Rheem CPROPH40 T2 RH350BM Specs Compare to Hybrid/Electric Heat Pump Medians?
Rheem CPROPH40 T2 RH350BM places #481 of 706 across 706 certified Hybrid/Electric Heat Pump configurations, with physical dimensions, draw profile, and thermal metrics benchmarked below.
| Specification Attribute | Certified Value | Cohort Benchmark / Delta | Provenance |
|---|---|---|---|
| Manufacturer / Brand | Rheem | 236 certified listings | ENERGY STAR PD 3994201 |
| Model Number | CPROPH40 T2 RH350BM | Draw pattern: Medium-Usage | CPROPH40 T2 RH350BM |
| Uniform Energy Factor (UEF) | 3.5 | -0.20 UEF vs. 3.70 UEF median | 10 CFR 430 Test Method |
| First Hour Rating (FHR) | 60 gal | -12 gal vs. 72 gal median | 10 CFR 430 Recovery Test |
| Rated Annual Electricity Use | 879 kWh/yr | -193 kWh/yr vs. 1,072 kWh/yr median | Est. $160/yr @ $0.1816/kWh (EIA US Avg) |
| Thermal Recovery Efficiency | 430% | +1.0 pts vs. 429.0% median | ENERGY STAR Dataset |
| Physical Envelope (H x Dia) | 62.3" H x 20.3" D | Fits standard 72 in. basement/garage clearance; clears 28 in. utility doorway (20.3" D) | Doorway & ceiling check |
| Electrical Circuit Requirements | 240 V / 21 A max | Requires 240V dedicated branch circuit; check panel capacity | NEC / Branch circuit check |
| Heat Pump Refrigerant & GWP | R-134a (GWP:1430) | Check regional AIM Act phase-down transition | EPA AIM Act Compliance |
| Certification Date | 2026-10-15 | Certified 2026-10-15 | Markets: Canada |
What Does CPROPH40 T2 RH350BM Cost to Operate Across State Electricity Rates?
At 879 kWh/yr, Rheem CPROPH40 T2 RH350BM runs roughly $160/yr on the EIA national average tier under August 2026 Table 5.6.A rates.
| Jurisdiction (EIA Aug 2026) | Residential Rate | Annual Cost | 10-Yr Operating Spend | 10-Yr Savings vs. 0.92 UEF |
|---|---|---|---|---|
| United States Average | 18.16 ¢/kWh ($0.1816) | $160/yr | $1,596 | $4,476 |
| Hawaii (Highest EIA State) | 47.18 ¢/kWh ($0.4718) | $415/yr | $4,147 | $11,630 |
| California | 29.75 ¢/kWh ($0.2975) | $262/yr | $2,615 | $7,333 |
| Texas | 15.91 ¢/kWh ($0.1591) | $140/yr | $1,398 | $3,922 |
| Washington (Lowest Hydro Tier) | 14.63 ¢/kWh ($0.1463) | $129/yr | $1,286 | $3,606 |
Are There Active CPSC Safety Recalls for Rheem Water Heaters?
Our 2026-11-23 CPSC SaferProducts query surfaced 4 brand-level recall notices associated with Rheem; match your serial plate before repair. See Serial Number Lookup.
- Recall #16177 (2016-05-26): Rheem Recalls to Repair Water Heaters Due to Fire and Burn Hazards; Sold Exclusively at Home Depot (CPSC Notice)
- Recall #07108 (2007-02-21): Tankless Water Heaters Recalled for Repair Due to Carbon Monoxide Poisoning Hazard (CPSC Notice)
- Recall #05274 (2005-09-16): CPSC, Robertshaw Controls Co. Announce Recall of Gas Control Valves on Water Heaters (CPSC Notice)
- Recall #80042 (1980-12-04): LP Gas Water Heaters Repaired by White-Rodgers (CPSC Notice)
Which Certified Water Heaters Match CPROPH40 T2 RH350BM Most Closely?
These 5 competing Hybrid/Electric Heat Pump units sit nearest to Rheem CPROPH40 T2 RH350BM by storage capacity and 3.5 UEF rating.
| Brand & Model | Type | Vol | FHR | UEF (Δ) | kWh/yr |
|---|---|---|---|---|---|
| Friedrich PROH40 T2 FD310BM | Hybrid/Electric Heat Pump | 36 gal | 60 gal | 3.5 (at parity) | 879 |
| Ruud PRO H40 T2 RU310BM | Hybrid/Electric Heat Pump | 36 gal | 60 gal | 3.5 (at parity) | 879 |
| Richmond 10CE40-HP5U15 | Hybrid/Electric Heat Pump | 36 gal | 46 gal | 3.45 (-0.05) | 643 |
| A. O. Smith CAHP-40 2** | Hybrid/Electric Heat Pump | 36 gal | 55 gal | 3.6 (+0.10) | 902 |
| Friedrich PROH40 T2 FD310UM | Hybrid/Electric Heat Pump | 36 gal | 60 gal | 3.5 (at parity) | 879 |
Which Home Setups Are NOT a Fit for Rheem CPROPH40 T2 RH350BM?
Comparing Rheem CPROPH40 T2 RH350BM against Friedrich PROH40 T2 FD310BM requires checking closet airflow, IFGC gas or 240V electrical sizing, and May 6, 2029 compliance.
Key Limitations & Exclusions
- Rheem CPROPH40 T2 RH350BM needs >=450 cu ft room air volume or ducting so compressor cooling does not stall recovery.
- Compressor runs near 49 dBA; avoid mounting Rheem CPROPH40 T2 RH350BM directly beside quiet bedrooms.
- Requires condensate drain routing and 240V electrical capacity; verify state DOE HEAR status.
Which Option Fits Your Situation?
What Are the Key Questions About Rheem CPROPH40 T2 RH350BM?
Direct answers to common technical, regulatory, and sizing questions sourced from primary U.S. government and OEM documentation.
How does Rheem CPROPH40 T2 RH350BM score under 10 CFR 430.32 May 2029 water heater minimums?
Federal 10 CFR 430.32 rules set the May 6, 2029 manufacturing baseline; Rheem CPROPH40 T2 RH350BM logs 3.5 UEF (Pass: +1.20 / +52.2%) within the 706-unit Hybrid/Electric Heat Pump group.
What physical clearance dimensions apply when installing Rheem CPROPH40 T2 RH350BM?
With a 62.3 in. height and 20.3 in. diameter, Rheem CPROPH40 T2 RH350BM fits spaces matching: fits standard 72 in. basement/garage clearance; clears 28 in. utility doorway (20.3" d), plus 6–12 in. above for plumbing shutoffs.
What 240V circuit or IFGC fuel line capacity fits Rheem CPROPH40 T2 RH350BM?
Powered via 240V at 21A max, Rheem CPROPH40 T2 RH350BM requires: Requires 240V dedicated branch circuit; check panel capacity. Confirm double-pole breaker sizing and condensate pump outlet proximity.
How do state electricity prices change annual costs for Rheem CPROPH40 T2 RH350BM?
Annual electric spend for Rheem CPROPH40 T2 RH350BM (879 kWh/yr) averages $160/yr nationwide (ranging from $129/yr in Washington hydro tiers up to $415/yr in Hawaii), calculated directly from August 2026 EIA Table 5.6.A tariffs.
What homeowner setups should avoid choosing Rheem CPROPH40 T2 RH350BM?
Homes lacking a condensate drain or 240V branch circuit—or unconditioned sub-zero spaces—should verify hybrid backup mode limits on Rheem CPROPH40 T2 RH350BM.
Is Rheem CPROPH40 T2 RH350BM sized adequately for a 2-to-4-person household?
ENERGY STAR certifies Rheem CPROPH40 T2 RH350BM at 60 gal First Hour Rating (-12 gal vs. 72 gal median); match that hourly reserve against simultaneous 2.0 GPM showerheads.
Does Rheem have active CPSC SaferProducts notices affecting CPROPH40 T2 RH350BM?
CPSC SaferProducts records show 4 brand-level recall notices mentioning Rheem as of 2026-11-23, including #16177 (2016-05-26). Enter the rating-plate serial into TapAndPipe's Serial Lookup tool to verify production week.
Which competing water heater matches Rheem CPROPH40 T2 RH350BM (3.5 UEF) most closely?
State-run DOE HEAR programs (<=150% AMI, up to $1,750 for HPWH) and electric utilities lead 2026 incentives for Rheem CPROPH40 T2 RH350BM. Closest peer in Hybrid/Electric Heat Pump is Friedrich PROH40 T2 FD310BM (3.5 UEF).
Sources
- ENERGY STAR Certified Water Heaters Dataset (Socrata pbpq-swnu) — U.S. EPA & DOE ENERGY STAR, 2026 Live Certified Registry (retrieved 2026-11-23)
- 10 CFR 430.32 — Energy and Water Conservation Standards (Water Heaters & Plumbing Fixtures) — U.S. Department of Energy / eCFR, 2026 eCFR (incl. May 6, 2029 Rule) (retrieved 2026-11-23)
- CPSC SaferProducts.gov Product Recalls REST API — U.S. Consumer Product Safety Commission, 2026 Live Recalls Feed (retrieved 2026-11-23)
- EIA Electric Power Monthly Table 5.6.A — Average Residential Electricity Price by State — U.S. Energy Information Administration (EIA), August 2026 Monthly Release (retrieved 2026-11-23)