Richmond 10CE40-HP5U15 Water Heater Specifications (3.45 UEF)
Certified at 3.45 UEF across its 36-gallon nominal tank, 46 gal First Hour Rating, Richmond 10CE40-HP5U15 (Hybrid/Electric Heat Pump, Electric) places #563 of 706 out of 706 ENERGY STAR models (PD 4572781). Its May 6, 2029 10 CFR 430.32 status reads Pass: +1.15 / +50.0%. Rated annual electricity draw of 643 kWh/yr equates to roughly $117/yr ($1,168 over 10 years) at 18.16 cents/kWh. Closest certified alternative is Friedrich PROH40 T2 FD400-15 (3.45 UEF).
- Uniform Energy Factor
- 3.45 UEF
- Cohort UEF Rank
- #563 of 706
- First Hour Rating
- 46 gal
- Storage Volume
- 36 gal
- Fuel / Type
- Electric / Hybrid/Electric Heat Pump
- DOE 2029 Rule Status
- Pass: +1.15 / +50.0%

Tested at 3.45 UEF, Richmond 10CE40-HP5U15 places #563 of 706 across 706 certified Hybrid/Electric Heat Pump configurations (-0.25 UEF vs. 3.70 UEF median).
Richmond 10CE40-HP5U15 clears 10 CFR 430.32(d)(2) Electric >35 to <=55 gal (2.30 UEF) by +1.15 UEF (+50.0% headroom). At EIA August 2026 national rates (18.16 cents/kWh), 643 kWh/yr for Richmond 10CE40-HP5U15 runs ~$117/yr vs. ~$438/yr for a 0.92 UEF electric tank.
State electric sensitivity for Richmond 10CE40-HP5U15: 10-year operating spend spans $941 in Washington (Lowest Hydro Tier) (14.63 cents/kWh) to $3,034 in Hawaii (Highest EIA State) (47.18 cents/kWh).
Closest alternatives to Richmond 10CE40-HP5U15 include Friedrich PROH40 T2 FD400-15 (3.45 UEF, at parity) alongside Rheem CPROPH40 T2 RH400-15 (3.45 UEF, at parity).
Which Specs Set Richmond 10CE40-HP5U15 Apart From Cohort Averages?
Ranked #563 of 706 inside the 706-model Hybrid/Electric Heat Pump cohort, Richmond 10CE40-HP5U15 is evaluated row by row below against category medians.
| Specification Attribute | Certified Value | Cohort Benchmark / Delta | Provenance |
|---|---|---|---|
| Manufacturer / Brand | Richmond | 80 certified listings | ENERGY STAR PD 4572781 |
| Model Number | 10CE40-HP5U15 | Draw pattern: Low-Usage | 10CE40-HP5U15 |
| Uniform Energy Factor (UEF) | 3.45 | -0.25 UEF vs. 3.70 UEF median | 10 CFR 430 Test Method |
| First Hour Rating (FHR) | 46 gal | -26 gal vs. 72 gal median | 10 CFR 430 Recovery Test |
| Rated Annual Electricity Use | 643 kWh/yr | -429 kWh/yr vs. 1,072 kWh/yr median | Est. $117/yr @ $0.1816/kWh (EIA US Avg) |
| Thermal Recovery Efficiency | 432% | +3.0 pts vs. 429.0% median | ENERGY STAR Dataset |
| Physical Envelope (H x Dia) | 62.3" H x 20.3" D | Fits standard 72 in. basement/garage clearance; clears 28 in. utility doorway (20.3" D) | Doorway & ceiling check |
| Electrical Circuit Requirements | 240 V / 12 A max | Requires 240V dedicated branch circuit; check panel capacity | NEC / Branch circuit check |
| Heat Pump Refrigerant & GWP | R-134a (GWP:1430) | Check regional AIM Act phase-down transition | EPA AIM Act Compliance |
| Certification Date | 2026-03-24 | Certified 2026-03-24 | Markets: Canada |
How Do Regional kWh Prices Impact 10CE40-HP5U15 Over 10 Years?
Using EIA Table 5.6.A benchmarks, Richmond 10CE40-HP5U15's 643 kWh/yr draw translates to roughly $117/yr on typical US residential bills.
| Jurisdiction (EIA Aug 2026) | Residential Rate | Annual Cost | 10-Yr Operating Spend | 10-Yr Savings vs. 0.92 UEF |
|---|---|---|---|---|
| United States Average | 18.16 ¢/kWh ($0.1816) | $117/yr | $1,168 | $3,211 |
| Hawaii (Highest EIA State) | 47.18 ¢/kWh ($0.4718) | $303/yr | $3,034 | $8,341 |
| California | 29.75 ¢/kWh ($0.2975) | $191/yr | $1,913 | $5,260 |
| Texas | 15.91 ¢/kWh ($0.1591) | $102/yr | $1,023 | $2,813 |
| Washington (Lowest Hydro Tier) | 14.63 ¢/kWh ($0.1463) | $94/yr | $941 | $2,587 |
What Should Richmond Owners Check in CPSC Recall Logs?
The 2026-11-23 CPSC recall sweep recorded zero brand matches for Richmond; run a quick serial-number check to verify age before replacing wear parts. See Serial Number Lookup.
How Do Five Nearby Hybrid/Electric Heat Pump Models Stack Up?
Five alternative Hybrid/Electric Heat Pump units with nearly identical gallon storage and UEF scores are listed below alongside exact efficiency spreads.
| Brand & Model | Type | Vol | FHR | UEF (Δ) | kWh/yr |
|---|---|---|---|---|---|
| Friedrich PROH40 T2 FD400-15 | Hybrid/Electric Heat Pump | 36 gal | 46 gal | 3.45 (at parity) | 643 |
| Rheem CPROPH40 T2 RH400-15 | Hybrid/Electric Heat Pump | 36 gal | 46 gal | 3.45 (at parity) | 643 |
| Ruud PROUH40 T2 CD400-15 | Hybrid/Electric Heat Pump | 36 gal | 46 gal | 3.45 (at parity) | 643 |
| A. O. Smith CAHP-40 2** | Hybrid/Electric Heat Pump | 36 gal | 55 gal | 3.6 (+0.15) | 902 |
| Rheem ECEPH40 T2 RH400-15 | Hybrid/Electric Heat Pump | 36 gal | 46 gal | 3.45 (at parity) | 643 |
What Are the Limitations of Richmond 10CE40-HP5U15 and Who Should Not Install It?
Before ordering Richmond 10CE40-HP5U15 (Hybrid/Electric Heat Pump, 3.45 UEF), weigh space clearances, fuel piping, noise (standard dBA), and 2029 rule readiness across three scenarios.
Key Limitations & Exclusions
- Richmond 10CE40-HP5U15 needs >=450 cu ft room air volume or ducting so compressor cooling does not stall recovery.
- Compressor runs near 49 dBA; avoid mounting Richmond 10CE40-HP5U15 directly beside quiet bedrooms.
- Requires condensate drain routing and 240V electrical capacity; verify state DOE HEAR status.
Which Option Fits Your Situation?
Frequently Asked Technical Questions: Richmond 10CE40-HP5U15
Direct answers to common technical, regulatory, and sizing questions sourced from primary U.S. government and OEM documentation.
Does Richmond 10CE40-HP5U15 pass the May 6, 2029 federal DOE efficiency rule?
Richmond 10CE40-HP5U15 carries a verified 3.45 UEF rating (Pass: +1.15 / +50.0%), ranking #563 of 706 across 706 ENERGY STAR Hybrid/Electric Heat Pump models under 10 CFR 430.32.
What doorway width and ceiling height does Richmond 10CE40-HP5U15 need?
Richmond 10CE40-HP5U15 stands 62.3 in. high with a 20.3 in. diameter; fits standard 72 in. basement/garage clearance; clears 28 in. utility doorway (20.3" d). Leave overhead clearance for dielectric nipples, ball shutoff valves, and top air filters.
What gas pipe size or electrical breaker does Richmond 10CE40-HP5U15 require?
Richmond 10CE40-HP5U15 uses a 240V branch circuit at 12A max (Requires 240V dedicated branch circuit; check panel capacity). Verify main breaker space before replacing a gas tank with an electric hybrid unit.
How much electricity or energy does Richmond 10CE40-HP5U15 cost per year to run?
Rated at 643 kWh/yr, Richmond 10CE40-HP5U15 costs about $117/yr ($1,170 over 10 years) at the August 2026 EIA US average of 18.16 cents/kWh (ranging from $94/yr in Washington hydro tiers up to $303/yr in Hawaii).
Who should NOT install Richmond 10CE40-HP5U15, and what are its limits?
Richmond 10CE40-HP5U15 (3.45 UEF) is a poor fit for unvented closets under 450 cu ft because compressor intake chills enclosed rooms and runs at 49 dBA.
How many bathrooms or people can Richmond 10CE40-HP5U15 serve at peak demand?
Richmond 10CE40-HP5U15 achieves a 46 gal First Hour Rating (-26 gal vs. 72 gal median). Two back-to-back showers plus a dishwasher run typically call for 55–70 gal FHR.
Are there CPSC safety recalls or serial checks for Richmond 10CE40-HP5U15?
No active CPSC recalls matched Richmond as of 2026-11-23. Always decode the serial tag on Richmond 10CE40-HP5U15 because OEM tank/exchanger warranties span 6–12 years.
What 2026 rebates apply to Richmond 10CE40-HP5U15, and what peer compares closest?
Federal Section 25C expired Dec 31, 2025 (P.L. 119-21); qualifying HPWHs remain eligible for state DOE HEAR rebates up to $1,750 (<=150% AMI). Closest peer in Hybrid/Electric Heat Pump is Friedrich PROH40 T2 FD400-15 (3.45 UEF).
Sources
- ENERGY STAR Certified Water Heaters Dataset (Socrata pbpq-swnu) — U.S. EPA & DOE ENERGY STAR, 2026 Live Certified Registry (retrieved 2026-11-23)
- 10 CFR 430.32 — Energy and Water Conservation Standards (Water Heaters & Plumbing Fixtures) — U.S. Department of Energy / eCFR, 2026 eCFR (incl. May 6, 2029 Rule) (retrieved 2026-11-23)
- CPSC SaferProducts.gov Product Recalls REST API — U.S. Consumer Product Safety Commission, 2026 Live Recalls Feed (retrieved 2026-11-23)
- EIA Electric Power Monthly Table 5.6.A — Average Residential Electricity Price by State — U.S. Energy Information Administration (EIA), August 2026 Monthly Release (retrieved 2026-11-23)