Friedrich PROH40 T2 FD310BM Water Heater Specifications (3.5 UEF)
With PD 3845918 certification, Friedrich PROH40 T2 FD310BM (Hybrid/Electric Heat Pump, Electric) achieves a certified 3.5 UEF rating across its 36-gallon nominal tank, 60 gal First Hour Rating, standing #481 of 706 across 706 peers with Pass: +1.20 / +52.2% for May 6, 2029. Rated annual electricity draw of 879 kWh/yr equates to roughly $160/yr ($1,596 over 10 years) at 18.16 cents/kWh. Closest certified alternative is Rheem CPROPH40 T2 RH350BM (3.5 UEF).
- Uniform Energy Factor
- 3.5 UEF
- Cohort UEF Rank
- #481 of 706
- First Hour Rating
- 60 gal
- Storage Volume
- 36 gal
- Fuel / Type
- Electric / Hybrid/Electric Heat Pump
- DOE 2029 Rule Status
- Pass: +1.20 / +52.2%

ENERGY STAR certification places Friedrich PROH40 T2 FD310BM at 3.5 UEF (#481 of 706; -0.20 UEF vs. 3.70 UEF median) in Hybrid/Electric Heat Pump.
May 6, 2029 readiness: Friedrich PROH40 T2 FD310BM stands +1.20 UEF (+52.2%) relative to 10 CFR 430.32(d)(2) Electric >35 to <=55 gal (2.30 UEF). At EIA August 2026 national rates (18.16 cents/kWh), 879 kWh/yr for Friedrich PROH40 T2 FD310BM runs ~$160/yr vs. ~$607/yr for a 0.92 UEF electric tank.
State electric sensitivity for Friedrich PROH40 T2 FD310BM: 10-year operating spend spans $1,286 in Washington (Lowest Hydro Tier) (14.63 cents/kWh) to $4,147 in Hawaii (Highest EIA State) (47.18 cents/kWh).
In the Hybrid/Electric Heat Pump tier, Rheem CPROPH40 T2 RH350BM (3.5 UEF, at parity) and Ruud PRO H40 T2 RU310BM (3.5 UEF, at parity) bracket Friedrich PROH40 T2 FD310BM.
How Complete Are the Certified Metrics for Friedrich PROH40 T2 FD310BM?
Standing at #481 of 706 among 706 certified Hybrid/Electric Heat Pump heaters, Friedrich PROH40 T2 FD310BM brings measurable deltas in recovery, footprint, and energy efficiency.
| Specification Attribute | Certified Value | Cohort Benchmark / Delta | Provenance |
|---|---|---|---|
| Manufacturer / Brand | Friedrich | 61 certified listings | ENERGY STAR PD 3845918 |
| Model Number | PROH40 T2 FD310BM | Draw pattern: Medium-Usage | PROH40 T2 FD310BM |
| Uniform Energy Factor (UEF) | 3.5 | -0.20 UEF vs. 3.70 UEF median | 10 CFR 430 Test Method |
| First Hour Rating (FHR) | 60 gal | -12 gal vs. 72 gal median | 10 CFR 430 Recovery Test |
| Rated Annual Electricity Use | 879 kWh/yr | -193 kWh/yr vs. 1,072 kWh/yr median | Est. $160/yr @ $0.1816/kWh (EIA US Avg) |
| Thermal Recovery Efficiency | 430% | +1.0 pts vs. 429.0% median | ENERGY STAR Dataset |
| Physical Envelope (H x Dia) | 62.3" H x 20.3" D | Fits standard 72 in. basement/garage clearance; clears 28 in. utility doorway (20.3" D) | Doorway & ceiling check |
| Electrical Circuit Requirements | 240 V / 21 A max | Requires 240V dedicated branch circuit; check panel capacity | NEC / Branch circuit check |
| Heat Pump Refrigerant & GWP | R-134a (GWP:1430) | Check regional AIM Act phase-down transition | EPA AIM Act Compliance |
| Certification Date | 2026-10-15 | Certified 2026-10-15 | Markets: United States |
What Is the Projected Utility Bill for PROH40 T2 FD310BM by State?
At 879 kWh/yr, Friedrich PROH40 T2 FD310BM averages about $160/yr across US households—see 10-year payback spreads versus 0.92 UEF resistance tanks.
| Jurisdiction (EIA Aug 2026) | Residential Rate | Annual Cost | 10-Yr Operating Spend | 10-Yr Savings vs. 0.92 UEF |
|---|---|---|---|---|
| United States Average | 18.16 ¢/kWh ($0.1816) | $160/yr | $1,596 | $4,476 |
| Hawaii (Highest EIA State) | 47.18 ¢/kWh ($0.4718) | $415/yr | $4,147 | $11,630 |
| California | 29.75 ¢/kWh ($0.2975) | $262/yr | $2,615 | $7,333 |
| Texas | 15.91 ¢/kWh ($0.1591) | $140/yr | $1,398 | $3,922 |
| Washington (Lowest Hydro Tier) | 14.63 ¢/kWh ($0.1463) | $129/yr | $1,286 | $3,606 |
Are Friedrich Models Affected by Current CPSC Notices?
Zero brand-level CPSC hazard notices matched Friedrich in our 2026-11-23 feed; decode your water heater's serial number below to confirm warranty status. See Serial Number Lookup.
Which 5 Models Offer Similar Output to PROH40 T2 FD310BM?
Ordered by minimal capacity and UEF spread relative to Friedrich PROH40 T2 FD310BM, these five certified peers give direct replacement benchmarks.
| Brand & Model | Type | Vol | FHR | UEF (Δ) | kWh/yr |
|---|---|---|---|---|---|
| Rheem CPROPH40 T2 RH350BM | Hybrid/Electric Heat Pump | 36 gal | 60 gal | 3.5 (at parity) | 879 |
| Ruud PRO H40 T2 RU310BM | Hybrid/Electric Heat Pump | 36 gal | 60 gal | 3.5 (at parity) | 879 |
| Richmond 10CE40-HP5U15 | Hybrid/Electric Heat Pump | 36 gal | 46 gal | 3.45 (-0.05) | 643 |
| A. O. Smith CAHP-40 2** | Hybrid/Electric Heat Pump | 36 gal | 55 gal | 3.6 (+0.10) | 902 |
| Rheem ECE H40 T2 RH310BM | Hybrid/Electric Heat Pump | 36 gal | 60 gal | 3.5 (at parity) | 879 |
Which Home Setups Are NOT a Fit for Friedrich PROH40 T2 FD310BM?
Comparing Friedrich PROH40 T2 FD310BM against Rheem CPROPH40 T2 RH350BM requires checking closet airflow, IFGC gas or 240V electrical sizing, and May 6, 2029 compliance.
Key Limitations & Exclusions
- Friedrich PROH40 T2 FD310BM needs >=450 cu ft room air volume or ducting so compressor cooling does not stall recovery.
- Compressor runs near 49 dBA; avoid mounting Friedrich PROH40 T2 FD310BM directly beside quiet bedrooms.
- Requires condensate drain routing and 240V electrical capacity; verify state DOE HEAR status.
Which Option Fits Your Situation?
Practical Specs & Code Questions for Friedrich PROH40 T2 FD310BM
Direct answers to common technical, regulatory, and sizing questions sourced from primary U.S. government and OEM documentation.
How does Friedrich PROH40 T2 FD310BM score under 10 CFR 430.32 May 2029 water heater minimums?
Federal 10 CFR 430.32 rules set the May 6, 2029 manufacturing baseline; Friedrich PROH40 T2 FD310BM logs 3.5 UEF (Pass: +1.20 / +52.2%) within the 706-unit Hybrid/Electric Heat Pump group.
What physical clearance dimensions apply when installing Friedrich PROH40 T2 FD310BM?
With a 62.3 in. height and 20.3 in. diameter, Friedrich PROH40 T2 FD310BM fits spaces matching: fits standard 72 in. basement/garage clearance; clears 28 in. utility doorway (20.3" d), plus 6–12 in. above for plumbing shutoffs.
What 240V circuit or IFGC fuel line capacity fits Friedrich PROH40 T2 FD310BM?
Powered via 240V at 21A max, Friedrich PROH40 T2 FD310BM requires: Requires 240V dedicated branch circuit; check panel capacity. Confirm double-pole breaker sizing and condensate pump outlet proximity.
How do state electricity prices change annual costs for Friedrich PROH40 T2 FD310BM?
Annual electric spend for Friedrich PROH40 T2 FD310BM (879 kWh/yr) averages $160/yr nationwide (ranging from $129/yr in Washington hydro tiers up to $415/yr in Hawaii), calculated directly from August 2026 EIA Table 5.6.A tariffs.
What homeowner setups should avoid choosing Friedrich PROH40 T2 FD310BM?
Homes lacking a condensate drain or 240V branch circuit—or unconditioned sub-zero spaces—should verify hybrid backup mode limits on Friedrich PROH40 T2 FD310BM.
Is Friedrich PROH40 T2 FD310BM sized adequately for a 2-to-4-person household?
ENERGY STAR certifies Friedrich PROH40 T2 FD310BM at 60 gal First Hour Rating (-12 gal vs. 72 gal median); match that hourly reserve against simultaneous 2.0 GPM showerheads.
Does Friedrich have active CPSC SaferProducts notices affecting PROH40 T2 FD310BM?
Zero CPSC recall alerts matched Friedrich (2026-11-23 check). Keep your Friedrich PROH40 T2 FD310BM serial code handy to track standard 6-to-12-year OEM warranty coverage.
Which competing water heater matches Friedrich PROH40 T2 FD310BM (3.5 UEF) most closely?
State-run DOE HEAR programs (<=150% AMI, up to $1,750 for HPWH) and electric utilities lead 2026 incentives for Friedrich PROH40 T2 FD310BM. Closest peer in Hybrid/Electric Heat Pump is Rheem CPROPH40 T2 RH350BM (3.5 UEF).
Sources
- ENERGY STAR Certified Water Heaters Dataset (Socrata pbpq-swnu) — U.S. EPA & DOE ENERGY STAR, 2026 Live Certified Registry (retrieved 2026-11-23)
- 10 CFR 430.32 — Energy and Water Conservation Standards (Water Heaters & Plumbing Fixtures) — U.S. Department of Energy / eCFR, 2026 eCFR (incl. May 6, 2029 Rule) (retrieved 2026-11-23)
- CPSC SaferProducts.gov Product Recalls REST API — U.S. Consumer Product Safety Commission, 2026 Live Recalls Feed (retrieved 2026-11-23)
- EIA Electric Power Monthly Table 5.6.A — Average Residential Electricity Price by State — U.S. Energy Information Administration (EIA), August 2026 Monthly Release (retrieved 2026-11-23)