Skip to main content
ENERGY STAR water heater model · PD 3845918

Friedrich PROH40 T2 FD310BM Water Heater Specifications (3.5 UEF)

With PD 3845918 certification, Friedrich PROH40 T2 FD310BM (Hybrid/Electric Heat Pump, Electric) achieves a certified 3.5 UEF rating across its 36-gallon nominal tank, 60 gal First Hour Rating, standing #481 of 706 across 706 peers with Pass: +1.20 / +52.2% for May 6, 2029. Rated annual electricity draw of 879 kWh/yr equates to roughly $160/yr ($1,596 over 10 years) at 18.16 cents/kWh. Closest certified alternative is Rheem CPROPH40 T2 RH350BM (3.5 UEF).

Uniform Energy Factor
3.5 UEF
Cohort UEF Rank
#481 of 706
First Hour Rating
60 gal
Storage Volume
36 gal
Fuel / Type
Electric / Hybrid/Electric Heat Pump
DOE 2029 Rule Status
Pass: +1.20 / +52.2%
Hybrid heat pump water heater upper shroud with brass relief valve and insulated copper risers
Hybrid heat pump water heater upper shroud with brass relief valve and insulated copper risers
Hybrid/Electric Heat Pump UEF Efficiency Distribution (706 Certified Units)Distribution of certified UEF ratings across 706 units in Hybrid/Electric Heat Pump, marking Friedrich PROH40 T2 FD310BM at 3.5 UEF.21130201631342031241542.52 UEF4.50 UEFMedian 3.702029 min 2.30Friedrich PROH40 T2 FD310BM: 3.50
Hybrid/Electric Heat Pump UEF Efficiency Distribution (706 Certified Units). Highlighted pin shows Friedrich PROH40 T2 FD310BM relative to the cohort median.
Efficiency comparison & rule summary

ENERGY STAR certification places Friedrich PROH40 T2 FD310BM at 3.5 UEF (#481 of 706; -0.20 UEF vs. 3.70 UEF median) in Hybrid/Electric Heat Pump.

May 6, 2029 readiness: Friedrich PROH40 T2 FD310BM stands +1.20 UEF (+52.2%) relative to 10 CFR 430.32(d)(2) Electric >35 to <=55 gal (2.30 UEF). At EIA August 2026 national rates (18.16 cents/kWh), 879 kWh/yr for Friedrich PROH40 T2 FD310BM runs ~$160/yr vs. ~$607/yr for a 0.92 UEF electric tank.

State electric sensitivity for Friedrich PROH40 T2 FD310BM: 10-year operating spend spans $1,286 in Washington (Lowest Hydro Tier) (14.63 cents/kWh) to $4,147 in Hawaii (Highest EIA State) (47.18 cents/kWh).

In the Hybrid/Electric Heat Pump tier, Rheem CPROPH40 T2 RH350BM (3.5 UEF, at parity) and Ruud PRO H40 T2 RU310BM (3.5 UEF, at parity) bracket Friedrich PROH40 T2 FD310BM.

How Complete Are the Certified Metrics for Friedrich PROH40 T2 FD310BM?

Standing at #481 of 706 among 706 certified Hybrid/Electric Heat Pump heaters, Friedrich PROH40 T2 FD310BM brings measurable deltas in recovery, footprint, and energy efficiency.

Certified model attributes compared against 706 ENERGY STAR Hybrid/Electric Heat Pump peers
Specification AttributeCertified ValueCohort Benchmark / DeltaProvenance
Manufacturer / BrandFriedrich61 certified listingsENERGY STAR PD 3845918
Model NumberPROH40 T2 FD310BMDraw pattern: Medium-UsagePROH40 T2 FD310BM
Uniform Energy Factor (UEF)3.5-0.20 UEF vs. 3.70 UEF median10 CFR 430 Test Method
First Hour Rating (FHR)60 gal-12 gal vs. 72 gal median10 CFR 430 Recovery Test
Rated Annual Electricity Use879 kWh/yr-193 kWh/yr vs. 1,072 kWh/yr medianEst. $160/yr @ $0.1816/kWh (EIA US Avg)
Thermal Recovery Efficiency430%+1.0 pts vs. 429.0% medianENERGY STAR Dataset
Physical Envelope (H x Dia)62.3" H x 20.3" DFits standard 72 in. basement/garage clearance; clears 28 in. utility doorway (20.3" D)Doorway & ceiling check
Electrical Circuit Requirements240 V / 21 A maxRequires 240V dedicated branch circuit; check panel capacityNEC / Branch circuit check
Heat Pump Refrigerant & GWPR-134a (GWP:1430)Check regional AIM Act phase-down transitionEPA AIM Act Compliance
Certification Date2026-10-15Certified 2026-10-15Markets: United States

What Is the Projected Utility Bill for PROH40 T2 FD310BM by State?

At 879 kWh/yr, Friedrich PROH40 T2 FD310BM averages about $160/yr across US households—see 10-year payback spreads versus 0.92 UEF resistance tanks.

Estimated Annual Electricity Cost by State Rate (879 kWh/yr)Projected annual electricity spend across five benchmark EIA August 2026 residential electric tiers.United States Average$160.00/yrHawaii$415.00/yrCalifornia$262.00/yrTexas$140.00/yrWashington$129.00/yr
Projected annual electricity spend across five benchmark EIA August 2026 residential electric tiers.
Estimated electricity cost and 10-year spend across benchmark states
Jurisdiction (EIA Aug 2026)Residential RateAnnual Cost10-Yr Operating Spend10-Yr Savings vs. 0.92 UEF
United States Average 18.16 ¢/kWh ($0.1816) $160/yr $1,596 $4,476
Hawaii (Highest EIA State) 47.18 ¢/kWh ($0.4718) $415/yr $4,147 $11,630
California 29.75 ¢/kWh ($0.2975) $262/yr $2,615 $7,333
Texas 15.91 ¢/kWh ($0.1591) $140/yr $1,398 $3,922
Washington (Lowest Hydro Tier) 14.63 ¢/kWh ($0.1463) $129/yr $1,286 $3,606
Estimated electricity spend (879 kWh/yr)

Condensing Gas Tankless vs. Storage Tank Flow Path & Gas Supply Engineering schematic contrasting 199,000 BTU/h condensing tankless piping (3/4 in. gas supply, Category IV PVC vent, condensate drain) against a 40,000 BTU/h atmospheric tank. Condensing Gas Tankless (0.91–0.96 UEF) Secondary HX Cat IV PVC Vent Cold In Hot Out 3/4"–1" Gas 199K BTU/h Condensate Atmospheric Storage Tank (0.58–0.65 UEF) Type B Flue Anode Rod 40K BTU/h 1/2" Gas Up to 100 ft T&P 150 psi 50–85 gal FHR Reserve | 8–12 yr life
Technical comparison: condensing gas tankless units require 3/4 in.–1 in. IFGC Table 402.4 gas supply and Category IV condensate drainage, while atmospheric tanks run on 1/2 in. lines.

Are Friedrich Models Affected by Current CPSC Notices?

Zero brand-level CPSC hazard notices matched Friedrich in our 2026-11-23 feed; decode your water heater's serial number below to confirm warranty status. See Serial Number Lookup.

Which 5 Models Offer Similar Output to PROH40 T2 FD310BM?

Ordered by minimal capacity and UEF spread relative to Friedrich PROH40 T2 FD310BM, these five certified peers give direct replacement benchmarks.

5 closest certified peers matched by equipment class, storage volume, and efficiency rating
Brand & ModelTypeVolFHRUEF (Δ)kWh/yr
Rheem CPROPH40 T2 RH350BM Hybrid/Electric Heat Pump 36 gal 60 gal 3.5 (at parity) 879
Ruud PRO H40 T2 RU310BM Hybrid/Electric Heat Pump 36 gal 60 gal 3.5 (at parity) 879
Richmond 10CE40-HP5U15 Hybrid/Electric Heat Pump 36 gal 46 gal 3.45 (-0.05) 643
A. O. Smith CAHP-40 2** Hybrid/Electric Heat Pump 36 gal 55 gal 3.6 (+0.10) 902
Rheem ECE H40 T2 RH310BM Hybrid/Electric Heat Pump 36 gal 60 gal 3.5 (at parity) 879

Which Home Setups Are NOT a Fit for Friedrich PROH40 T2 FD310BM?

Comparing Friedrich PROH40 T2 FD310BM against Rheem CPROPH40 T2 RH350BM requires checking closet airflow, IFGC gas or 240V electrical sizing, and May 6, 2029 compliance.

Key Limitations & Exclusions

  • Friedrich PROH40 T2 FD310BM needs >=450 cu ft room air volume or ducting so compressor cooling does not stall recovery.
  • Compressor runs near 49 dBA; avoid mounting Friedrich PROH40 T2 FD310BM directly beside quiet bedrooms.
  • Requires condensate drain routing and 240V electrical capacity; verify state DOE HEAR status.

Which Option Fits Your Situation?

High Electric Rate States Choosing Friedrich PROH40 T2 FD310BM Strong Fit — 3.5 UEF trims electric use ~75% vs 0.92 UEF tanks.
Open Basement or Garage (>=450 cu ft) Strong Fit — Ample ambient air sustains heat-pump-only efficiency.
Small Interior Closet (<300 cu ft) Caution — Add duct kit or compare Rheem CPROPH40 T2 RH350BM footprint.

Practical Specs & Code Questions for Friedrich PROH40 T2 FD310BM

Direct answers to common technical, regulatory, and sizing questions sourced from primary U.S. government and OEM documentation.

How does Friedrich PROH40 T2 FD310BM score under 10 CFR 430.32 May 2029 water heater minimums?

Federal 10 CFR 430.32 rules set the May 6, 2029 manufacturing baseline; Friedrich PROH40 T2 FD310BM logs 3.5 UEF (Pass: +1.20 / +52.2%) within the 706-unit Hybrid/Electric Heat Pump group.

What physical clearance dimensions apply when installing Friedrich PROH40 T2 FD310BM?

With a 62.3 in. height and 20.3 in. diameter, Friedrich PROH40 T2 FD310BM fits spaces matching: fits standard 72 in. basement/garage clearance; clears 28 in. utility doorway (20.3" d), plus 6–12 in. above for plumbing shutoffs.

What 240V circuit or IFGC fuel line capacity fits Friedrich PROH40 T2 FD310BM?

Powered via 240V at 21A max, Friedrich PROH40 T2 FD310BM requires: Requires 240V dedicated branch circuit; check panel capacity. Confirm double-pole breaker sizing and condensate pump outlet proximity.

How do state electricity prices change annual costs for Friedrich PROH40 T2 FD310BM?

Annual electric spend for Friedrich PROH40 T2 FD310BM (879 kWh/yr) averages $160/yr nationwide (ranging from $129/yr in Washington hydro tiers up to $415/yr in Hawaii), calculated directly from August 2026 EIA Table 5.6.A tariffs.

What homeowner setups should avoid choosing Friedrich PROH40 T2 FD310BM?

Homes lacking a condensate drain or 240V branch circuit—or unconditioned sub-zero spaces—should verify hybrid backup mode limits on Friedrich PROH40 T2 FD310BM.

Is Friedrich PROH40 T2 FD310BM sized adequately for a 2-to-4-person household?

ENERGY STAR certifies Friedrich PROH40 T2 FD310BM at 60 gal First Hour Rating (-12 gal vs. 72 gal median); match that hourly reserve against simultaneous 2.0 GPM showerheads.

Does Friedrich have active CPSC SaferProducts notices affecting PROH40 T2 FD310BM?

Zero CPSC recall alerts matched Friedrich (2026-11-23 check). Keep your Friedrich PROH40 T2 FD310BM serial code handy to track standard 6-to-12-year OEM warranty coverage.

Which competing water heater matches Friedrich PROH40 T2 FD310BM (3.5 UEF) most closely?

State-run DOE HEAR programs (<=150% AMI, up to $1,750 for HPWH) and electric utilities lead 2026 incentives for Friedrich PROH40 T2 FD310BM. Closest peer in Hybrid/Electric Heat Pump is Rheem CPROPH40 T2 RH350BM (3.5 UEF).

Sources

  1. ENERGY STAR Certified Water Heaters Dataset (Socrata pbpq-swnu) — U.S. EPA & DOE ENERGY STAR, 2026 Live Certified Registry (retrieved 2026-11-23)
  2. 10 CFR 430.32 — Energy and Water Conservation Standards (Water Heaters & Plumbing Fixtures) — U.S. Department of Energy / eCFR, 2026 eCFR (incl. May 6, 2029 Rule) (retrieved 2026-11-23)
  3. CPSC SaferProducts.gov Product Recalls REST API — U.S. Consumer Product Safety Commission, 2026 Live Recalls Feed (retrieved 2026-11-23)
  4. EIA Electric Power Monthly Table 5.6.A — Average Residential Electricity Price by State — U.S. Energy Information Administration (EIA), August 2026 Monthly Release (retrieved 2026-11-23)

Related U.S. Metro Plumbing Benchmarks