Rheem CPROPH40 T2 RH400-15 Water Heater Specifications (3.45 UEF)
Engineered as a Electric Hybrid/Electric Heat Pump unit, Rheem CPROPH40 T2 RH400-15 achieves a certified 3.45 UEF rating across its 36-gallon nominal tank, 46 gal First Hour Rating and ranks #563 of 706 in its 706-model cohort (PD 3554172), recording Pass: +1.15 / +50.0% under 2029 DOE rules. Rated annual electricity draw of 643 kWh/yr equates to roughly $117/yr ($1,168 over 10 years) at 18.16 cents/kWh. Closest certified alternative is Friedrich PROH40 T2 FD400-15 (3.45 UEF).
- Uniform Energy Factor
- 3.45 UEF
- Cohort UEF Rank
- #563 of 706
- First Hour Rating
- 46 gal
- Storage Volume
- 36 gal
- Fuel / Type
- Electric / Hybrid/Electric Heat Pump
- DOE 2029 Rule Status
- Pass: +1.15 / +50.0%

Within the 706-unit Hybrid/Electric Heat Pump cohort, Rheem CPROPH40 T2 RH400-15 logs 3.45 UEF and ranks #563 of 706.
Against 10 CFR 430.32(d)(2) Electric >35 to <=55 gal (2.30 UEF), Rheem CPROPH40 T2 RH400-15 holds a +1.15 UEF (+50.0%) compliance cushion. At EIA August 2026 national rates (18.16 cents/kWh), 643 kWh/yr for Rheem CPROPH40 T2 RH400-15 runs ~$117/yr vs. ~$438/yr for a 0.92 UEF electric tank.
State electric sensitivity for Rheem CPROPH40 T2 RH400-15: 10-year operating spend spans $941 in Washington (Lowest Hydro Tier) (14.63 cents/kWh) to $3,034 in Hawaii (Highest EIA State) (47.18 cents/kWh).
Cross-shopping Rheem CPROPH40 T2 RH400-15 (3.45 UEF)? Check Friedrich PROH40 T2 FD400-15 (3.45 UEF, at parity) and Richmond 10CE40-HP5U15 (3.45 UEF, at parity).
Where Does Rheem CPROPH40 T2 RH400-15 Rank Against Peer Hybrid/Electric Heat Pump Units?
Audited against 706 ENERGY STAR Hybrid/Electric Heat Pump listings, Rheem CPROPH40 T2 RH400-15 holds #563 of 706; inspect footprint, circuit load, and efficiency deltas here.
| Specification Attribute | Certified Value | Cohort Benchmark / Delta | Provenance |
|---|---|---|---|
| Manufacturer / Brand | Rheem | 236 certified listings | ENERGY STAR PD 3554172 |
| Model Number | CPROPH40 T2 RH400-15 | Draw pattern: Low-Usage | CPROPH40 T2 RH400-15 |
| Uniform Energy Factor (UEF) | 3.45 | -0.25 UEF vs. 3.70 UEF median | 10 CFR 430 Test Method |
| First Hour Rating (FHR) | 46 gal | -26 gal vs. 72 gal median | 10 CFR 430 Recovery Test |
| Rated Annual Electricity Use | 643 kWh/yr | -429 kWh/yr vs. 1,072 kWh/yr median | Est. $117/yr @ $0.1816/kWh (EIA US Avg) |
| Thermal Recovery Efficiency | 432% | +3.0 pts vs. 429.0% median | ENERGY STAR Dataset |
| Physical Envelope (H x Dia) | 62.3" H x 20.3" D | Fits standard 72 in. basement/garage clearance; clears 28 in. utility doorway (20.3" D) | Doorway & ceiling check |
| Electrical Circuit Requirements | 240 V / 12 A max | Requires 240V dedicated branch circuit; check panel capacity | NEC / Branch circuit check |
| Heat Pump Refrigerant & GWP | R-134a (GWP:1430) | Check regional AIM Act phase-down transition | EPA AIM Act Compliance |
| Certification Date | 2026-10-15 | Certified 2026-10-15 | Markets: Canada |
How Much Electricity Does CPROPH40 T2 RH400-15 Use in Different States?
Estimated at $117/yr nationally (643 kWh/yr), 10-year utility spending for Rheem CPROPH40 T2 RH400-15 shifts sharply between low-rate hydro and coastal grids.
| Jurisdiction (EIA Aug 2026) | Residential Rate | Annual Cost | 10-Yr Operating Spend | 10-Yr Savings vs. 0.92 UEF |
|---|---|---|---|---|
| United States Average | 18.16 ¢/kWh ($0.1816) | $117/yr | $1,168 | $3,211 |
| Hawaii (Highest EIA State) | 47.18 ¢/kWh ($0.4718) | $303/yr | $3,034 | $8,341 |
| California | 29.75 ¢/kWh ($0.2975) | $191/yr | $1,913 | $5,260 |
| Texas | 15.91 ¢/kWh ($0.1591) | $102/yr | $1,023 | $2,813 |
| Washington (Lowest Hydro Tier) | 14.63 ¢/kWh ($0.1463) | $94/yr | $941 | $2,587 |
Does CPSC Flag Any Safety Notices on Rheem Units?
Checking 2026-11-23 SaferProducts data shows 4 notices mentioning Rheem; always cross-reference affected serial prefixes before ordering components. See Serial Number Lookup.
- Recall #16177 (2016-05-26): Rheem Recalls to Repair Water Heaters Due to Fire and Burn Hazards; Sold Exclusively at Home Depot (CPSC Notice)
- Recall #07108 (2007-02-21): Tankless Water Heaters Recalled for Repair Due to Carbon Monoxide Poisoning Hazard (CPSC Notice)
- Recall #05274 (2005-09-16): CPSC, Robertshaw Controls Co. Announce Recall of Gas Control Valves on Water Heaters (CPSC Notice)
- Recall #80042 (1980-12-04): LP Gas Water Heaters Repaired by White-Rodgers (CPSC Notice)
Which Competing Hybrid/Electric Heat Pump Models Compare Closest to CPROPH40 T2 RH400-15?
Compare five nearby ENERGY STAR Hybrid/Electric Heat Pump options matched closely to Rheem CPROPH40 T2 RH400-15's gallon capacity and 3.45 UEF efficiency.
| Brand & Model | Type | Vol | FHR | UEF (Δ) | kWh/yr |
|---|---|---|---|---|---|
| Friedrich PROH40 T2 FD400-15 | Hybrid/Electric Heat Pump | 36 gal | 46 gal | 3.45 (at parity) | 643 |
| Richmond 10CE40-HP5U15 | Hybrid/Electric Heat Pump | 36 gal | 46 gal | 3.45 (at parity) | 643 |
| Ruud PROUH40 T2 CD400-15 | Hybrid/Electric Heat Pump | 36 gal | 46 gal | 3.45 (at parity) | 643 |
| A. O. Smith CAHP-40 2** | Hybrid/Electric Heat Pump | 36 gal | 55 gal | 3.6 (+0.15) | 902 |
| Richmond 10E40-HP5U15 | Hybrid/Electric Heat Pump | 36 gal | 46 gal | 3.45 (at parity) | 643 |
What Are the Limitations of Rheem CPROPH40 T2 RH400-15 and Who Should Not Install It?
Before ordering Rheem CPROPH40 T2 RH400-15 (Hybrid/Electric Heat Pump, 3.45 UEF), weigh space clearances, fuel piping, noise (standard dBA), and 2029 rule readiness across three scenarios.
Key Limitations & Exclusions
- Rheem CPROPH40 T2 RH400-15 needs >=450 cu ft room air volume or ducting so compressor cooling does not stall recovery.
- Compressor runs near 49 dBA; avoid mounting Rheem CPROPH40 T2 RH400-15 directly beside quiet bedrooms.
- Requires condensate drain routing and 240V electrical capacity; verify state DOE HEAR status.
Which Option Fits Your Situation?
Common Homeowner Questions for Rheem CPROPH40 T2 RH400-15
Direct answers to common technical, regulatory, and sizing questions sourced from primary U.S. government and OEM documentation.
Does Rheem CPROPH40 T2 RH400-15 pass the May 6, 2029 federal DOE efficiency rule?
Rheem CPROPH40 T2 RH400-15 carries a verified 3.45 UEF rating (Pass: +1.15 / +50.0%), ranking #563 of 706 across 706 ENERGY STAR Hybrid/Electric Heat Pump models under 10 CFR 430.32.
What doorway width and ceiling height does Rheem CPROPH40 T2 RH400-15 need?
Rheem CPROPH40 T2 RH400-15 stands 62.3 in. high with a 20.3 in. diameter; fits standard 72 in. basement/garage clearance; clears 28 in. utility doorway (20.3" d). Leave overhead clearance for dielectric nipples, ball shutoff valves, and top air filters.
What gas pipe size or electrical breaker does Rheem CPROPH40 T2 RH400-15 require?
Rheem CPROPH40 T2 RH400-15 uses a 240V branch circuit at 12A max (Requires 240V dedicated branch circuit; check panel capacity). Verify main breaker space before replacing a gas tank with an electric hybrid unit.
How much electricity or energy does Rheem CPROPH40 T2 RH400-15 cost per year to run?
Rated at 643 kWh/yr, Rheem CPROPH40 T2 RH400-15 costs about $117/yr ($1,170 over 10 years) at the August 2026 EIA US average of 18.16 cents/kWh (ranging from $94/yr in Washington hydro tiers up to $303/yr in Hawaii).
Who should NOT install Rheem CPROPH40 T2 RH400-15, and what are its limits?
Rheem CPROPH40 T2 RH400-15 (3.45 UEF) is a poor fit for unvented closets under 450 cu ft because compressor intake chills enclosed rooms and runs at 49 dBA.
How many bathrooms or people can Rheem CPROPH40 T2 RH400-15 serve at peak demand?
Rheem CPROPH40 T2 RH400-15 achieves a 46 gal First Hour Rating (-26 gal vs. 72 gal median). Two back-to-back showers plus a dishwasher run typically call for 55–70 gal FHR.
Are there CPSC safety recalls or serial checks for Rheem CPROPH40 T2 RH400-15?
CPSC SaferProducts records show 4 brand-level recall notices mentioning Rheem as of 2026-11-23, including #16177 (2016-05-26). Enter the rating-plate serial into TapAndPipe's Serial Lookup tool to verify production week.
What 2026 rebates apply to Rheem CPROPH40 T2 RH400-15, and what peer compares closest?
Federal Section 25C expired Dec 31, 2025 (P.L. 119-21); qualifying HPWHs remain eligible for state DOE HEAR rebates up to $1,750 (<=150% AMI). Closest peer in Hybrid/Electric Heat Pump is Friedrich PROH40 T2 FD400-15 (3.45 UEF).
Sources
- ENERGY STAR Certified Water Heaters Dataset (Socrata pbpq-swnu) — U.S. EPA & DOE ENERGY STAR, 2026 Live Certified Registry (retrieved 2026-11-23)
- 10 CFR 430.32 — Energy and Water Conservation Standards (Water Heaters & Plumbing Fixtures) — U.S. Department of Energy / eCFR, 2026 eCFR (incl. May 6, 2029 Rule) (retrieved 2026-11-23)
- CPSC SaferProducts.gov Product Recalls REST API — U.S. Consumer Product Safety Commission, 2026 Live Recalls Feed (retrieved 2026-11-23)
- EIA Electric Power Monthly Table 5.6.A — Average Residential Electricity Price by State — U.S. Energy Information Administration (EIA), August 2026 Monthly Release (retrieved 2026-11-23)