Skip to main content
ENERGY STAR water heater model · PD 3554168

Richmond 10E40-HP5U15 Water Heater Specifications (3.45 UEF)

With PD 3554168 certification, Richmond 10E40-HP5U15 (Hybrid/Electric Heat Pump, Electric) achieves a certified 3.45 UEF rating across its 36-gallon nominal tank, 46 gal First Hour Rating, standing #563 of 706 across 706 peers with Pass: +1.15 / +50.0% for May 6, 2029. Rated annual electricity draw of 643 kWh/yr equates to roughly $117/yr ($1,168 over 10 years) at 18.16 cents/kWh. Closest certified alternative is Friedrich PROH40 T2 FD400-15 (3.45 UEF).

Uniform Energy Factor
3.45 UEF
Cohort UEF Rank
#563 of 706
First Hour Rating
46 gal
Storage Volume
36 gal
Fuel / Type
Electric / Hybrid/Electric Heat Pump
DOE 2029 Rule Status
Pass: +1.15 / +50.0%
Hybrid heat pump water heater upper shroud with brass relief valve and insulated copper risers
Hybrid heat pump water heater upper shroud with brass relief valve and insulated copper risers
Hybrid/Electric Heat Pump UEF Efficiency Distribution (706 Certified Units)Distribution of certified UEF ratings across 706 units in Hybrid/Electric Heat Pump, marking Richmond 10E40-HP5U15 at 3.45 UEF.21130201631342031241542.52 UEF4.50 UEFMedian 3.702029 min 2.30Richmond 10E40-HP5U15: 3.45
Hybrid/Electric Heat Pump UEF Efficiency Distribution (706 Certified Units). Highlighted pin shows Richmond 10E40-HP5U15 relative to the cohort median.
Efficiency comparison & rule summary

ENERGY STAR certification places Richmond 10E40-HP5U15 at 3.45 UEF (#563 of 706; -0.25 UEF vs. 3.70 UEF median) in Hybrid/Electric Heat Pump.

May 6, 2029 readiness: Richmond 10E40-HP5U15 stands +1.15 UEF (+50.0%) relative to 10 CFR 430.32(d)(2) Electric >35 to <=55 gal (2.30 UEF). At EIA August 2026 national rates (18.16 cents/kWh), 643 kWh/yr for Richmond 10E40-HP5U15 runs ~$117/yr vs. ~$438/yr for a 0.92 UEF electric tank.

State electric sensitivity for Richmond 10E40-HP5U15: 10-year operating spend spans $941 in Washington (Lowest Hydro Tier) (14.63 cents/kWh) to $3,034 in Hawaii (Highest EIA State) (47.18 cents/kWh).

In the Hybrid/Electric Heat Pump tier, Friedrich PROH40 T2 FD400-15 (3.45 UEF, at parity) and Rheem CPROPH40 T2 RH400-15 (3.45 UEF, at parity) bracket Richmond 10E40-HP5U15.

What Physical and Thermal Ratings Define Richmond 10E40-HP5U15?

Positioning at #563 of 706 out of 706 Hybrid/Electric Heat Pump peers, Richmond 10E40-HP5U15 pairs measured UEF performance with specific clearance and wiring rules.

Certified model attributes compared against 706 ENERGY STAR Hybrid/Electric Heat Pump peers
Specification AttributeCertified ValueCohort Benchmark / DeltaProvenance
Manufacturer / BrandRichmond80 certified listingsENERGY STAR PD 3554168
Model Number10E40-HP5U15Draw pattern: Low-Usage10E40-HP5U15
Uniform Energy Factor (UEF)3.45-0.25 UEF vs. 3.70 UEF median10 CFR 430 Test Method
First Hour Rating (FHR)46 gal-26 gal vs. 72 gal median10 CFR 430 Recovery Test
Rated Annual Electricity Use643 kWh/yr-429 kWh/yr vs. 1,072 kWh/yr medianEst. $117/yr @ $0.1816/kWh (EIA US Avg)
Thermal Recovery Efficiency432%+3.0 pts vs. 429.0% medianENERGY STAR Dataset
Physical Envelope (H x Dia)62.3" H x 20.3" DFits standard 72 in. basement/garage clearance; clears 28 in. utility doorway (20.3" D)Doorway & ceiling check
Electrical Circuit Requirements240 V / 12 A maxRequires 240V dedicated branch circuit; check panel capacityNEC / Branch circuit check
Heat Pump Refrigerant & GWPR-134a (GWP:1430)Check regional AIM Act phase-down transitionEPA AIM Act Compliance
Certification Date2026-10-15Certified 2026-10-15Markets: United States

Why Do State Utility Rates Shift 10E40-HP5U15 Running Costs?

Consuming 643 kWh annually puts Richmond 10E40-HP5U15 near $117/yr at US baseline tariffs, with multi-state EIA comparisons charted below.

Estimated Annual Electricity Cost by State Rate (643 kWh/yr)Projected annual electricity spend across five benchmark EIA August 2026 residential electric tiers.United States Average$117.00/yrHawaii$303.00/yrCalifornia$191.00/yrTexas$102.00/yrWashington$94.00/yr
Projected annual electricity spend across five benchmark EIA August 2026 residential electric tiers.
Estimated electricity cost and 10-year spend across benchmark states
Jurisdiction (EIA Aug 2026)Residential RateAnnual Cost10-Yr Operating Spend10-Yr Savings vs. 0.92 UEF
United States Average 18.16 ¢/kWh ($0.1816) $117/yr $1,168 $3,211
Hawaii (Highest EIA State) 47.18 ¢/kWh ($0.4718) $303/yr $3,034 $8,341
California 29.75 ¢/kWh ($0.2975) $191/yr $1,913 $5,260
Texas 15.91 ¢/kWh ($0.1591) $102/yr $1,023 $2,813
Washington (Lowest Hydro Tier) 14.63 ¢/kWh ($0.1463) $94/yr $941 $2,587
Estimated electricity spend (643 kWh/yr)

Condensing Gas Tankless vs. Storage Tank Flow Path & Gas Supply Engineering schematic contrasting 199,000 BTU/h condensing tankless piping (3/4 in. gas supply, Category IV PVC vent, condensate drain) against a 40,000 BTU/h atmospheric tank. Condensing Gas Tankless (0.91–0.96 UEF) Secondary HX Cat IV PVC Vent Cold In Hot Out 3/4"–1" Gas 199K BTU/h Condensate Atmospheric Storage Tank (0.58–0.65 UEF) Type B Flue Anode Rod 40K BTU/h 1/2" Gas Up to 100 ft T&P 150 psi 50–85 gal FHR Reserve | 8–12 yr life
Technical comparison: condensing gas tankless units require 3/4 in.–1 in. IFGC Table 402.4 gas supply and Category IV condensate drainage, while atmospheric tanks run on 1/2 in. lines.

Have Any Richmond Series Triggered CPSC Recalls?

SaferProducts screening on 2026-11-23 returned zero recall matches for Richmond; confirm tank age separately using the rating-plate serial pattern. See Serial Number Lookup.

What Are 5 Direct Alternatives to Richmond 10E40-HP5U15?

Homeowners cross-shopping Richmond 10E40-HP5U15 frequently review these five Hybrid/Electric Heat Pump models ranked closest on capacity and UEF output.

5 closest certified peers matched by equipment class, storage volume, and efficiency rating
Brand & ModelTypeVolFHRUEF (Δ)kWh/yr
Friedrich PROH40 T2 FD400-15 Hybrid/Electric Heat Pump 36 gal 46 gal 3.45 (at parity) 643
Rheem CPROPH40 T2 RH400-15 Hybrid/Electric Heat Pump 36 gal 46 gal 3.45 (at parity) 643
Ruud PROUH40 T2 CD400-15 Hybrid/Electric Heat Pump 36 gal 46 gal 3.45 (at parity) 643
A. O. Smith CAHP-40 2** Hybrid/Electric Heat Pump 36 gal 55 gal 3.6 (+0.15) 902
Rheem ECEPH40 T2 RH400-15 Hybrid/Electric Heat Pump 36 gal 46 gal 3.45 (at parity) 643

Which Home Setups Are NOT a Fit for Richmond 10E40-HP5U15?

Comparing Richmond 10E40-HP5U15 against Friedrich PROH40 T2 FD400-15 requires checking closet airflow, IFGC gas or 240V electrical sizing, and May 6, 2029 compliance.

Key Limitations & Exclusions

  • Richmond 10E40-HP5U15 needs >=450 cu ft room air volume or ducting so compressor cooling does not stall recovery.
  • Compressor runs near 49 dBA; avoid mounting Richmond 10E40-HP5U15 directly beside quiet bedrooms.
  • Requires condensate drain routing and 240V electrical capacity; verify state DOE HEAR status.

Which Option Fits Your Situation?

High Electric Rate States Choosing Richmond 10E40-HP5U15 Strong Fit — 3.45 UEF trims electric use ~75% vs 0.92 UEF tanks.
Open Basement or Garage (>=450 cu ft) Strong Fit — Ample ambient air sustains heat-pump-only efficiency.
Small Interior Closet (<300 cu ft) Caution — Add duct kit or compare Friedrich PROH40 T2 FD400-15 footprint.

Sizing, Efficiency & Recall Answers for Richmond 10E40-HP5U15

Direct answers to common technical, regulatory, and sizing questions sourced from primary U.S. government and OEM documentation.

How does Richmond 10E40-HP5U15 score under 10 CFR 430.32 May 2029 water heater minimums?

Federal 10 CFR 430.32 rules set the May 6, 2029 manufacturing baseline; Richmond 10E40-HP5U15 logs 3.45 UEF (Pass: +1.15 / +50.0%) within the 706-unit Hybrid/Electric Heat Pump group.

What physical clearance dimensions apply when installing Richmond 10E40-HP5U15?

With a 62.3 in. height and 20.3 in. diameter, Richmond 10E40-HP5U15 fits spaces matching: fits standard 72 in. basement/garage clearance; clears 28 in. utility doorway (20.3" d), plus 6–12 in. above for plumbing shutoffs.

What 240V circuit or IFGC fuel line capacity fits Richmond 10E40-HP5U15?

Powered via 240V at 12A max, Richmond 10E40-HP5U15 requires: Requires 240V dedicated branch circuit; check panel capacity. Confirm double-pole breaker sizing and condensate pump outlet proximity.

How do state electricity prices change annual costs for Richmond 10E40-HP5U15?

Annual electric spend for Richmond 10E40-HP5U15 (643 kWh/yr) averages $117/yr nationwide (ranging from $94/yr in Washington hydro tiers up to $303/yr in Hawaii), calculated directly from August 2026 EIA Table 5.6.A tariffs.

What homeowner setups should avoid choosing Richmond 10E40-HP5U15?

Homes lacking a condensate drain or 240V branch circuit—or unconditioned sub-zero spaces—should verify hybrid backup mode limits on Richmond 10E40-HP5U15.

Is Richmond 10E40-HP5U15 sized adequately for a 2-to-4-person household?

ENERGY STAR certifies Richmond 10E40-HP5U15 at 46 gal First Hour Rating (-26 gal vs. 72 gal median); match that hourly reserve against simultaneous 2.0 GPM showerheads.

Does Richmond have active CPSC SaferProducts notices affecting 10E40-HP5U15?

Zero CPSC recall alerts matched Richmond (2026-11-23 check). Keep your Richmond 10E40-HP5U15 serial code handy to track standard 6-to-12-year OEM warranty coverage.

Which competing water heater matches Richmond 10E40-HP5U15 (3.45 UEF) most closely?

State-run DOE HEAR programs (<=150% AMI, up to $1,750 for HPWH) and electric utilities lead 2026 incentives for Richmond 10E40-HP5U15. Closest peer in Hybrid/Electric Heat Pump is Friedrich PROH40 T2 FD400-15 (3.45 UEF).

Sources

  1. ENERGY STAR Certified Water Heaters Dataset (Socrata pbpq-swnu) — U.S. EPA & DOE ENERGY STAR, 2026 Live Certified Registry (retrieved 2026-11-23)
  2. 10 CFR 430.32 — Energy and Water Conservation Standards (Water Heaters & Plumbing Fixtures) — U.S. Department of Energy / eCFR, 2026 eCFR (incl. May 6, 2029 Rule) (retrieved 2026-11-23)
  3. CPSC SaferProducts.gov Product Recalls REST API — U.S. Consumer Product Safety Commission, 2026 Live Recalls Feed (retrieved 2026-11-23)
  4. EIA Electric Power Monthly Table 5.6.A — Average Residential Electricity Price by State — U.S. Energy Information Administration (EIA), August 2026 Monthly Release (retrieved 2026-11-23)

Related U.S. Metro Plumbing Benchmarks