Skip to main content
ENERGY STAR water heater model · PD 3554238

Rheem CPROPH80 T2 RH400-15 Water Heater Specifications (3.7 UEF)

With PD 3554238 certification, Rheem CPROPH80 T2 RH400-15 (Hybrid/Electric Heat Pump, Electric) achieves a certified 3.7 UEF rating across its 72-gallon nominal tank, 67 gal First Hour Rating, standing #347 of 706 across 706 peers with Pass: +1.20 / +48.0% for May 6, 2029. Rated annual electricity draw of 871 kWh/yr equates to roughly $158/yr ($1,582 over 10 years) at 18.16 cents/kWh. Closest certified alternative is Friedrich PROH80 T2 FD400-15 (3.7 UEF).

Uniform Energy Factor
3.7 UEF
Cohort UEF Rank
#347 of 706
First Hour Rating
67 gal
Storage Volume
72 gal
Fuel / Type
Electric / Hybrid/Electric Heat Pump
DOE 2029 Rule Status
Pass: +1.20 / +48.0%
Hybrid heat pump water heater upper shroud with brass relief valve and insulated copper risers
Hybrid heat pump water heater upper shroud with brass relief valve and insulated copper risers
Hybrid/Electric Heat Pump UEF Efficiency Distribution (706 Certified Units)Distribution of certified UEF ratings across 706 units in Hybrid/Electric Heat Pump, marking Rheem CPROPH80 T2 RH400-15 at 3.7 UEF.21130201631342031241542.52 UEF4.50 UEFMedian 3.702029 min 2.50Rheem CPROPH80 T2 RH400-15: 3.70
Hybrid/Electric Heat Pump UEF Efficiency Distribution (706 Certified Units). Highlighted pin shows Rheem CPROPH80 T2 RH400-15 relative to the cohort median.
Efficiency comparison & rule summary

ENERGY STAR certification places Rheem CPROPH80 T2 RH400-15 at 3.7 UEF (#347 of 706; At 3.70 UEF median) in Hybrid/Electric Heat Pump.

May 6, 2029 readiness: Rheem CPROPH80 T2 RH400-15 stands +1.20 UEF (+48.0%) relative to 10 CFR 430.32(d)(2) Electric >55 to <=120 gal (2.50 UEF). At EIA August 2026 national rates (18.16 cents/kWh), 871 kWh/yr for Rheem CPROPH80 T2 RH400-15 runs ~$158/yr vs. ~$636/yr for a 0.92 UEF electric tank.

State electric sensitivity for Rheem CPROPH80 T2 RH400-15: 10-year operating spend spans $1,274 in Washington (Lowest Hydro Tier) (14.63 cents/kWh) to $4,109 in Hawaii (Highest EIA State) (47.18 cents/kWh).

In the Hybrid/Electric Heat Pump tier, Friedrich PROH80 T2 FD400-15 (3.7 UEF, at parity) and Richmond 10CE80-HP5U15 (3.7 UEF, at parity) bracket Rheem CPROPH80 T2 RH400-15.

Which Specs Set Rheem CPROPH80 T2 RH400-15 Apart From Cohort Averages?

Ranked #347 of 706 inside the 706-model Hybrid/Electric Heat Pump cohort, Rheem CPROPH80 T2 RH400-15 is evaluated row by row below against category medians.

Certified model attributes compared against 706 ENERGY STAR Hybrid/Electric Heat Pump peers
Specification AttributeCertified ValueCohort Benchmark / DeltaProvenance
Manufacturer / BrandRheem236 certified listingsENERGY STAR PD 3554238
Model NumberCPROPH80 T2 RH400-15Draw pattern: Medium-UsageCPROPH80 T2 RH400-15
Uniform Energy Factor (UEF)3.7At 3.70 UEF median10 CFR 430 Test Method
First Hour Rating (FHR)67 gal-5 gal vs. 72 gal median10 CFR 430 Recovery Test
Rated Annual Electricity Use871 kWh/yr-201 kWh/yr vs. 1,072 kWh/yr medianEst. $158/yr @ $0.1816/kWh (EIA US Avg)
Thermal Recovery Efficiency445%+16.0 pts vs. 429.0% medianENERGY STAR Dataset
Physical Envelope (H x Dia)74.2" H x 24.3" DNeeds >72 in. overhead clearance; clears 28 in. utility doorway (24.3" D)Doorway & ceiling check
Electrical Circuit Requirements240 V / 12 A maxRequires 240V dedicated branch circuit; check panel capacityNEC / Branch circuit check
Heat Pump Refrigerant & GWPR-134a (GWP:1430)Check regional AIM Act phase-down transitionEPA AIM Act Compliance
Certification Date2026-10-15Certified 2026-10-15Markets: Canada

How Do Regional kWh Prices Impact CPROPH80 T2 RH400-15 Over 10 Years?

Using EIA Table 5.6.A benchmarks, Rheem CPROPH80 T2 RH400-15's 871 kWh/yr draw translates to roughly $158/yr on typical US residential bills.

Estimated Annual Electricity Cost by State Rate (871 kWh/yr)Projected annual electricity spend across five benchmark EIA August 2026 residential electric tiers.United States Average$158.00/yrHawaii$411.00/yrCalifornia$259.00/yrTexas$139.00/yrWashington$127.00/yr
Projected annual electricity spend across five benchmark EIA August 2026 residential electric tiers.
Estimated electricity cost and 10-year spend across benchmark states
Jurisdiction (EIA Aug 2026)Residential RateAnnual Cost10-Yr Operating Spend10-Yr Savings vs. 0.92 UEF
United States Average 18.16 ¢/kWh ($0.1816) $158/yr $1,582 $4,780
Hawaii (Highest EIA State) 47.18 ¢/kWh ($0.4718) $411/yr $4,109 $12,418
California 29.75 ¢/kWh ($0.2975) $259/yr $2,591 $7,830
Texas 15.91 ¢/kWh ($0.1591) $139/yr $1,386 $4,188
Washington (Lowest Hydro Tier) 14.63 ¢/kWh ($0.1463) $127/yr $1,274 $3,851
Estimated electricity spend (871 kWh/yr)

Condensing Gas Tankless vs. Storage Tank Flow Path & Gas Supply Engineering schematic contrasting 199,000 BTU/h condensing tankless piping (3/4 in. gas supply, Category IV PVC vent, condensate drain) against a 40,000 BTU/h atmospheric tank. Condensing Gas Tankless (0.91–0.96 UEF) Secondary HX Cat IV PVC Vent Cold In Hot Out 3/4"–1" Gas 199K BTU/h Condensate Atmospheric Storage Tank (0.58–0.65 UEF) Type B Flue Anode Rod 40K BTU/h 1/2" Gas Up to 100 ft T&P 150 psi 50–85 gal FHR Reserve | 8–12 yr life
Technical comparison: condensing gas tankless units require 3/4 in.–1 in. IFGC Table 402.4 gas supply and Category IV condensate drainage, while atmospheric tanks run on 1/2 in. lines.

What Should Rheem Owners Check in CPSC Recall Logs?

The 2026-11-23 CPSC SaferProducts snapshot includes 4 filings tied to Rheem; verify whether your CPROPH80 T2 RH400-15 production run falls inside affected ranges. See Serial Number Lookup.

4 Brand Recall Notices Found in CPSC Feed — Verify Serial & Model Range
  • Recall #16177 (2016-05-26): Rheem Recalls to Repair Water Heaters Due to Fire and Burn Hazards; Sold Exclusively at Home Depot (CPSC Notice)
  • Recall #07108 (2007-02-21): Tankless Water Heaters Recalled for Repair Due to Carbon Monoxide Poisoning Hazard (CPSC Notice)
  • Recall #05274 (2005-09-16): CPSC, Robertshaw Controls Co. Announce Recall of Gas Control Valves on Water Heaters (CPSC Notice)
  • Recall #80042 (1980-12-04): LP Gas Water Heaters Repaired by White-Rodgers (CPSC Notice)

How Do Five Nearby Hybrid/Electric Heat Pump Models Stack Up?

Five alternative Hybrid/Electric Heat Pump units with nearly identical gallon storage and UEF scores are listed below alongside exact efficiency spreads.

5 closest certified peers matched by equipment class, storage volume, and efficiency rating
Brand & ModelTypeVolFHRUEF (Δ)kWh/yr
Friedrich PROH80 T2 FD400-15 Hybrid/Electric Heat Pump 72 gal 67 gal 3.7 (at parity) 871
Richmond 10CE80-HP5U15 Hybrid/Electric Heat Pump 72 gal 67 gal 3.7 (at parity) 871
Ruud PROUH80 T2 CD400-15 Hybrid/Electric Heat Pump 72 gal 67 gal 3.7 (at parity) 871
LG APHWC801D Hybrid/Electric Heat Pump 72 gal 94 gal 3.9 (+0.20) 1,272
Richmond 10E80-HP515 Hybrid/Electric Heat Pump 72 gal 67 gal 3.7 (at parity) 871

What Installation Caveats Apply Before Buying Rheem CPROPH80 T2 RH400-15?

Even high-UEF units like Rheem CPROPH80 T2 RH400-15 (3.7 UEF) carry physical space, condensate, and fuel-line prerequisites noted below.

Key Limitations & Exclusions

  • Rheem CPROPH80 T2 RH400-15 needs >=450 cu ft room air volume or ducting so compressor cooling does not stall recovery.
  • Compressor runs near 49 dBA; avoid mounting Rheem CPROPH80 T2 RH400-15 directly beside quiet bedrooms.
  • Requires condensate drain routing and 240V electrical capacity; verify state DOE HEAR status.

Which Option Fits Your Situation?

High Electric Rate States Choosing Rheem CPROPH80 T2 RH400-15 Strong Fit — 3.7 UEF trims electric use ~75% vs 0.92 UEF tanks.
Open Basement or Garage (>=450 cu ft) Strong Fit — Ample ambient air sustains heat-pump-only efficiency.
Small Interior Closet (<300 cu ft) Caution — Add duct kit or compare Friedrich PROH80 T2 FD400-15 footprint.

Frequently Asked Technical Questions: Rheem CPROPH80 T2 RH400-15

Direct answers to common technical, regulatory, and sizing questions sourced from primary U.S. government and OEM documentation.

Is Rheem CPROPH80 T2 RH400-15 eligible for continued manufacture past May 6, 2029?

At 3.7 UEF, Rheem CPROPH80 T2 RH400-15 achieves Pass: +1.20 / +48.0% for the 2029 DOE standard and stands #347 of 706 against Friedrich PROH80 T2 FD400-15 and Richmond 10CE80-HP5U15.

How tall and wide is Rheem CPROPH80 T2 RH400-15, and what service clearance is needed?

Physical dimensions for Rheem CPROPH80 T2 RH400-15 are 74.2 in. height and 24.3 in. diameter (needs >72 in. overhead clearance; clears 28 in. utility doorway (24.3" d)); verify stair turns and drain pan width before delivery.

Will Rheem CPROPH80 T2 RH400-15 require upgrading household electrical panels or gas piping?

Rheem CPROPH80 T2 RH400-15 draws 240V at 12A max (Requires 240V dedicated branch circuit; check panel capacity); check whether existing 10/2 AWG 30A copper wiring aligns with nameplate amps.

Is Rheem CPROPH80 T2 RH400-15 economical to operate at 18.16 cents/kWh US electric rates?

Expect roughly $158/yr ($1,580 over 10 years) to power Rheem CPROPH80 T2 RH400-15 at 871 kWh/yr under the 18.16 cents/kWh US average (ranging from $127/yr in Washington hydro tiers up to $411/yr in Hawaii).

Which installation bottlenecks limit Rheem CPROPH80 T2 RH400-15?

If ambient room air stays below 40 °F year-round or closet volume falls under 450 cu ft, Rheem CPROPH80 T2 RH400-15 drops into resistance mode more often.

How does Rheem CPROPH80 T2 RH400-15 handle simultaneous showers and laundry?

Delivering 67 gal in the first hour (-5 gal vs. 72 gal median), Rheem CPROPH80 T2 RH400-15 combines 72 gal tank storage with rapid burner/element recovery.

How long is the warranty on Rheem CPROPH80 T2 RH400-15 and how do you decode its serial?

CPSC SaferProducts records show 4 brand-level recall notices mentioning Rheem as of 2026-11-23, including #16177 (2016-05-26). Enter the rating-plate serial into TapAndPipe's Serial Lookup tool to verify production week.

How do 2026 post-OBBBA rebates affect buying Rheem CPROPH80 T2 RH400-15?

Check state energy office HEAR portals and utility rebates in 2026 since federal 25C ended Dec 31, 2025. Closest peer in Hybrid/Electric Heat Pump is Friedrich PROH80 T2 FD400-15 (3.7 UEF).

Sources

  1. ENERGY STAR Certified Water Heaters Dataset (Socrata pbpq-swnu) — U.S. EPA & DOE ENERGY STAR, 2026 Live Certified Registry (retrieved 2026-11-23)
  2. 10 CFR 430.32 — Energy and Water Conservation Standards (Water Heaters & Plumbing Fixtures) — U.S. Department of Energy / eCFR, 2026 eCFR (incl. May 6, 2029 Rule) (retrieved 2026-11-23)
  3. CPSC SaferProducts.gov Product Recalls REST API — U.S. Consumer Product Safety Commission, 2026 Live Recalls Feed (retrieved 2026-11-23)
  4. EIA Electric Power Monthly Table 5.6.A — Average Residential Electricity Price by State — U.S. Energy Information Administration (EIA), August 2026 Monthly Release (retrieved 2026-11-23)

Related U.S. Metro Plumbing Benchmarks