Rheem CPROPH80 T2 RH400-15 Water Heater Specifications (3.7 UEF)
With PD 3554238 certification, Rheem CPROPH80 T2 RH400-15 (Hybrid/Electric Heat Pump, Electric) achieves a certified 3.7 UEF rating across its 72-gallon nominal tank, 67 gal First Hour Rating, standing #347 of 706 across 706 peers with Pass: +1.20 / +48.0% for May 6, 2029. Rated annual electricity draw of 871 kWh/yr equates to roughly $158/yr ($1,582 over 10 years) at 18.16 cents/kWh. Closest certified alternative is Friedrich PROH80 T2 FD400-15 (3.7 UEF).
- Uniform Energy Factor
- 3.7 UEF
- Cohort UEF Rank
- #347 of 706
- First Hour Rating
- 67 gal
- Storage Volume
- 72 gal
- Fuel / Type
- Electric / Hybrid/Electric Heat Pump
- DOE 2029 Rule Status
- Pass: +1.20 / +48.0%

ENERGY STAR certification places Rheem CPROPH80 T2 RH400-15 at 3.7 UEF (#347 of 706; At 3.70 UEF median) in Hybrid/Electric Heat Pump.
May 6, 2029 readiness: Rheem CPROPH80 T2 RH400-15 stands +1.20 UEF (+48.0%) relative to 10 CFR 430.32(d)(2) Electric >55 to <=120 gal (2.50 UEF). At EIA August 2026 national rates (18.16 cents/kWh), 871 kWh/yr for Rheem CPROPH80 T2 RH400-15 runs ~$158/yr vs. ~$636/yr for a 0.92 UEF electric tank.
State electric sensitivity for Rheem CPROPH80 T2 RH400-15: 10-year operating spend spans $1,274 in Washington (Lowest Hydro Tier) (14.63 cents/kWh) to $4,109 in Hawaii (Highest EIA State) (47.18 cents/kWh).
In the Hybrid/Electric Heat Pump tier, Friedrich PROH80 T2 FD400-15 (3.7 UEF, at parity) and Richmond 10CE80-HP5U15 (3.7 UEF, at parity) bracket Rheem CPROPH80 T2 RH400-15.
Which Specs Set Rheem CPROPH80 T2 RH400-15 Apart From Cohort Averages?
Ranked #347 of 706 inside the 706-model Hybrid/Electric Heat Pump cohort, Rheem CPROPH80 T2 RH400-15 is evaluated row by row below against category medians.
| Specification Attribute | Certified Value | Cohort Benchmark / Delta | Provenance |
|---|---|---|---|
| Manufacturer / Brand | Rheem | 236 certified listings | ENERGY STAR PD 3554238 |
| Model Number | CPROPH80 T2 RH400-15 | Draw pattern: Medium-Usage | CPROPH80 T2 RH400-15 |
| Uniform Energy Factor (UEF) | 3.7 | At 3.70 UEF median | 10 CFR 430 Test Method |
| First Hour Rating (FHR) | 67 gal | -5 gal vs. 72 gal median | 10 CFR 430 Recovery Test |
| Rated Annual Electricity Use | 871 kWh/yr | -201 kWh/yr vs. 1,072 kWh/yr median | Est. $158/yr @ $0.1816/kWh (EIA US Avg) |
| Thermal Recovery Efficiency | 445% | +16.0 pts vs. 429.0% median | ENERGY STAR Dataset |
| Physical Envelope (H x Dia) | 74.2" H x 24.3" D | Needs >72 in. overhead clearance; clears 28 in. utility doorway (24.3" D) | Doorway & ceiling check |
| Electrical Circuit Requirements | 240 V / 12 A max | Requires 240V dedicated branch circuit; check panel capacity | NEC / Branch circuit check |
| Heat Pump Refrigerant & GWP | R-134a (GWP:1430) | Check regional AIM Act phase-down transition | EPA AIM Act Compliance |
| Certification Date | 2026-10-15 | Certified 2026-10-15 | Markets: Canada |
How Do Regional kWh Prices Impact CPROPH80 T2 RH400-15 Over 10 Years?
Using EIA Table 5.6.A benchmarks, Rheem CPROPH80 T2 RH400-15's 871 kWh/yr draw translates to roughly $158/yr on typical US residential bills.
| Jurisdiction (EIA Aug 2026) | Residential Rate | Annual Cost | 10-Yr Operating Spend | 10-Yr Savings vs. 0.92 UEF |
|---|---|---|---|---|
| United States Average | 18.16 ¢/kWh ($0.1816) | $158/yr | $1,582 | $4,780 |
| Hawaii (Highest EIA State) | 47.18 ¢/kWh ($0.4718) | $411/yr | $4,109 | $12,418 |
| California | 29.75 ¢/kWh ($0.2975) | $259/yr | $2,591 | $7,830 |
| Texas | 15.91 ¢/kWh ($0.1591) | $139/yr | $1,386 | $4,188 |
| Washington (Lowest Hydro Tier) | 14.63 ¢/kWh ($0.1463) | $127/yr | $1,274 | $3,851 |
What Should Rheem Owners Check in CPSC Recall Logs?
The 2026-11-23 CPSC SaferProducts snapshot includes 4 filings tied to Rheem; verify whether your CPROPH80 T2 RH400-15 production run falls inside affected ranges. See Serial Number Lookup.
- Recall #16177 (2016-05-26): Rheem Recalls to Repair Water Heaters Due to Fire and Burn Hazards; Sold Exclusively at Home Depot (CPSC Notice)
- Recall #07108 (2007-02-21): Tankless Water Heaters Recalled for Repair Due to Carbon Monoxide Poisoning Hazard (CPSC Notice)
- Recall #05274 (2005-09-16): CPSC, Robertshaw Controls Co. Announce Recall of Gas Control Valves on Water Heaters (CPSC Notice)
- Recall #80042 (1980-12-04): LP Gas Water Heaters Repaired by White-Rodgers (CPSC Notice)
How Do Five Nearby Hybrid/Electric Heat Pump Models Stack Up?
Five alternative Hybrid/Electric Heat Pump units with nearly identical gallon storage and UEF scores are listed below alongside exact efficiency spreads.
| Brand & Model | Type | Vol | FHR | UEF (Δ) | kWh/yr |
|---|---|---|---|---|---|
| Friedrich PROH80 T2 FD400-15 | Hybrid/Electric Heat Pump | 72 gal | 67 gal | 3.7 (at parity) | 871 |
| Richmond 10CE80-HP5U15 | Hybrid/Electric Heat Pump | 72 gal | 67 gal | 3.7 (at parity) | 871 |
| Ruud PROUH80 T2 CD400-15 | Hybrid/Electric Heat Pump | 72 gal | 67 gal | 3.7 (at parity) | 871 |
| LG APHWC801D | Hybrid/Electric Heat Pump | 72 gal | 94 gal | 3.9 (+0.20) | 1,272 |
| Richmond 10E80-HP515 | Hybrid/Electric Heat Pump | 72 gal | 67 gal | 3.7 (at parity) | 871 |
What Installation Caveats Apply Before Buying Rheem CPROPH80 T2 RH400-15?
Even high-UEF units like Rheem CPROPH80 T2 RH400-15 (3.7 UEF) carry physical space, condensate, and fuel-line prerequisites noted below.
Key Limitations & Exclusions
- Rheem CPROPH80 T2 RH400-15 needs >=450 cu ft room air volume or ducting so compressor cooling does not stall recovery.
- Compressor runs near 49 dBA; avoid mounting Rheem CPROPH80 T2 RH400-15 directly beside quiet bedrooms.
- Requires condensate drain routing and 240V electrical capacity; verify state DOE HEAR status.
Which Option Fits Your Situation?
Frequently Asked Technical Questions: Rheem CPROPH80 T2 RH400-15
Direct answers to common technical, regulatory, and sizing questions sourced from primary U.S. government and OEM documentation.
Is Rheem CPROPH80 T2 RH400-15 eligible for continued manufacture past May 6, 2029?
At 3.7 UEF, Rheem CPROPH80 T2 RH400-15 achieves Pass: +1.20 / +48.0% for the 2029 DOE standard and stands #347 of 706 against Friedrich PROH80 T2 FD400-15 and Richmond 10CE80-HP5U15.
How tall and wide is Rheem CPROPH80 T2 RH400-15, and what service clearance is needed?
Physical dimensions for Rheem CPROPH80 T2 RH400-15 are 74.2 in. height and 24.3 in. diameter (needs >72 in. overhead clearance; clears 28 in. utility doorway (24.3" d)); verify stair turns and drain pan width before delivery.
Will Rheem CPROPH80 T2 RH400-15 require upgrading household electrical panels or gas piping?
Rheem CPROPH80 T2 RH400-15 draws 240V at 12A max (Requires 240V dedicated branch circuit; check panel capacity); check whether existing 10/2 AWG 30A copper wiring aligns with nameplate amps.
Is Rheem CPROPH80 T2 RH400-15 economical to operate at 18.16 cents/kWh US electric rates?
Expect roughly $158/yr ($1,580 over 10 years) to power Rheem CPROPH80 T2 RH400-15 at 871 kWh/yr under the 18.16 cents/kWh US average (ranging from $127/yr in Washington hydro tiers up to $411/yr in Hawaii).
Which installation bottlenecks limit Rheem CPROPH80 T2 RH400-15?
If ambient room air stays below 40 °F year-round or closet volume falls under 450 cu ft, Rheem CPROPH80 T2 RH400-15 drops into resistance mode more often.
How does Rheem CPROPH80 T2 RH400-15 handle simultaneous showers and laundry?
Delivering 67 gal in the first hour (-5 gal vs. 72 gal median), Rheem CPROPH80 T2 RH400-15 combines 72 gal tank storage with rapid burner/element recovery.
How long is the warranty on Rheem CPROPH80 T2 RH400-15 and how do you decode its serial?
CPSC SaferProducts records show 4 brand-level recall notices mentioning Rheem as of 2026-11-23, including #16177 (2016-05-26). Enter the rating-plate serial into TapAndPipe's Serial Lookup tool to verify production week.
How do 2026 post-OBBBA rebates affect buying Rheem CPROPH80 T2 RH400-15?
Check state energy office HEAR portals and utility rebates in 2026 since federal 25C ended Dec 31, 2025. Closest peer in Hybrid/Electric Heat Pump is Friedrich PROH80 T2 FD400-15 (3.7 UEF).
Sources
- ENERGY STAR Certified Water Heaters Dataset (Socrata pbpq-swnu) — U.S. EPA & DOE ENERGY STAR, 2026 Live Certified Registry (retrieved 2026-11-23)
- 10 CFR 430.32 — Energy and Water Conservation Standards (Water Heaters & Plumbing Fixtures) — U.S. Department of Energy / eCFR, 2026 eCFR (incl. May 6, 2029 Rule) (retrieved 2026-11-23)
- CPSC SaferProducts.gov Product Recalls REST API — U.S. Consumer Product Safety Commission, 2026 Live Recalls Feed (retrieved 2026-11-23)
- EIA Electric Power Monthly Table 5.6.A — Average Residential Electricity Price by State — U.S. Energy Information Administration (EIA), August 2026 Monthly Release (retrieved 2026-11-23)