Skip to main content
ENERGY STAR water heater model · PD 4572762

Ruud PROUH80 T2 CD400-15 Water Heater Specifications (3.7 UEF)

Engineered as a Electric Hybrid/Electric Heat Pump unit, Ruud PROUH80 T2 CD400-15 achieves a certified 3.7 UEF rating across its 72-gallon nominal tank, 67 gal First Hour Rating and ranks #347 of 706 in its 706-model cohort (PD 4572762), recording Pass: +1.20 / +48.0% under 2029 DOE rules. Rated annual electricity draw of 871 kWh/yr equates to roughly $158/yr ($1,582 over 10 years) at 18.16 cents/kWh. Closest certified alternative is Friedrich PROH80 T2 FD400-15 (3.7 UEF).

Uniform Energy Factor
3.7 UEF
Cohort UEF Rank
#347 of 706
First Hour Rating
67 gal
Storage Volume
72 gal
Fuel / Type
Electric / Hybrid/Electric Heat Pump
DOE 2029 Rule Status
Pass: +1.20 / +48.0%
Hybrid heat pump water heater upper shroud with brass relief valve and insulated copper risers
Hybrid heat pump water heater upper shroud with brass relief valve and insulated copper risers
Hybrid/Electric Heat Pump UEF Efficiency Distribution (706 Certified Units)Distribution of certified UEF ratings across 706 units in Hybrid/Electric Heat Pump, marking Ruud PROUH80 T2 CD400-15 at 3.7 UEF.21130201631342031241542.52 UEF4.50 UEFMedian 3.702029 min 2.50Ruud PROUH80 T2 CD400-15: 3.70
Hybrid/Electric Heat Pump UEF Efficiency Distribution (706 Certified Units). Highlighted pin shows Ruud PROUH80 T2 CD400-15 relative to the cohort median.
Efficiency comparison & rule summary

Within the 706-unit Hybrid/Electric Heat Pump cohort, Ruud PROUH80 T2 CD400-15 logs 3.7 UEF and ranks #347 of 706.

Against 10 CFR 430.32(d)(2) Electric >55 to <=120 gal (2.50 UEF), Ruud PROUH80 T2 CD400-15 holds a +1.20 UEF (+48.0%) compliance cushion. At EIA August 2026 national rates (18.16 cents/kWh), 871 kWh/yr for Ruud PROUH80 T2 CD400-15 runs ~$158/yr vs. ~$636/yr for a 0.92 UEF electric tank.

State electric sensitivity for Ruud PROUH80 T2 CD400-15: 10-year operating spend spans $1,274 in Washington (Lowest Hydro Tier) (14.63 cents/kWh) to $4,109 in Hawaii (Highest EIA State) (47.18 cents/kWh).

Cross-shopping Ruud PROUH80 T2 CD400-15 (3.7 UEF)? Check Friedrich PROH80 T2 FD400-15 (3.7 UEF, at parity) and Rheem CPROPH80 T2 RH375-15 (3.7 UEF, at parity).

Which Specs Set Ruud PROUH80 T2 CD400-15 Apart From Cohort Averages?

Ranked #347 of 706 inside the 706-model Hybrid/Electric Heat Pump cohort, Ruud PROUH80 T2 CD400-15 is evaluated row by row below against category medians.

Certified model attributes compared against 706 ENERGY STAR Hybrid/Electric Heat Pump peers
Specification AttributeCertified ValueCohort Benchmark / DeltaProvenance
Manufacturer / BrandRuud95 certified listingsENERGY STAR PD 4572762
Model NumberPROUH80 T2 CD400-15Draw pattern: Medium-UsagePROUH80 T2 CD400-15
Uniform Energy Factor (UEF)3.7At 3.70 UEF median10 CFR 430 Test Method
First Hour Rating (FHR)67 gal-5 gal vs. 72 gal median10 CFR 430 Recovery Test
Rated Annual Electricity Use871 kWh/yr-201 kWh/yr vs. 1,072 kWh/yr medianEst. $158/yr @ $0.1816/kWh (EIA US Avg)
Thermal Recovery Efficiency445%+16.0 pts vs. 429.0% medianENERGY STAR Dataset
Physical Envelope (H x Dia)74.2" H x 24.3" DNeeds >72 in. overhead clearance; clears 28 in. utility doorway (24.3" D)Doorway & ceiling check
Electrical Circuit Requirements240 V / 12 A maxRequires 240V dedicated branch circuit; check panel capacityNEC / Branch circuit check
Heat Pump Refrigerant & GWPR-134a (GWP:1430)Check regional AIM Act phase-down transitionEPA AIM Act Compliance
Certification Date2026-03-24Certified 2026-03-24Markets: Canada

How Do Regional kWh Prices Impact PROUH80 T2 CD400-15 Over 10 Years?

Using EIA Table 5.6.A benchmarks, Ruud PROUH80 T2 CD400-15's 871 kWh/yr draw translates to roughly $158/yr on typical US residential bills.

Estimated Annual Electricity Cost by State Rate (871 kWh/yr)Projected annual electricity spend across five benchmark EIA August 2026 residential electric tiers.United States Average$158.00/yrHawaii$411.00/yrCalifornia$259.00/yrTexas$139.00/yrWashington$127.00/yr
Projected annual electricity spend across five benchmark EIA August 2026 residential electric tiers.
Estimated electricity cost and 10-year spend across benchmark states
Jurisdiction (EIA Aug 2026)Residential RateAnnual Cost10-Yr Operating Spend10-Yr Savings vs. 0.92 UEF
United States Average 18.16 ¢/kWh ($0.1816) $158/yr $1,582 $4,780
Hawaii (Highest EIA State) 47.18 ¢/kWh ($0.4718) $411/yr $4,109 $12,418
California 29.75 ¢/kWh ($0.2975) $259/yr $2,591 $7,830
Texas 15.91 ¢/kWh ($0.1591) $139/yr $1,386 $4,188
Washington (Lowest Hydro Tier) 14.63 ¢/kWh ($0.1463) $127/yr $1,274 $3,851
Estimated electricity spend (871 kWh/yr)

Condensing Gas Tankless vs. Storage Tank Flow Path & Gas Supply Engineering schematic contrasting 199,000 BTU/h condensing tankless piping (3/4 in. gas supply, Category IV PVC vent, condensate drain) against a 40,000 BTU/h atmospheric tank. Condensing Gas Tankless (0.91–0.96 UEF) Secondary HX Cat IV PVC Vent Cold In Hot Out 3/4"–1" Gas 199K BTU/h Condensate Atmospheric Storage Tank (0.58–0.65 UEF) Type B Flue Anode Rod 40K BTU/h 1/2" Gas Up to 100 ft T&P 150 psi 50–85 gal FHR Reserve | 8–12 yr life
Technical comparison: condensing gas tankless units require 3/4 in.–1 in. IFGC Table 402.4 gas supply and Category IV condensate drainage, while atmospheric tanks run on 1/2 in. lines.

What Should Ruud Owners Check in CPSC Recall Logs?

The 2026-11-23 CPSC SaferProducts snapshot includes 2 filings tied to Ruud; verify whether your PROUH80 T2 CD400-15 production run falls inside affected ranges. See Serial Number Lookup.

2 Brand Recall Notices Found in CPSC Feed — Verify Serial & Model Range
  • Recall #07108 (2007-02-21): Tankless Water Heaters Recalled for Repair Due to Carbon Monoxide Poisoning Hazard (CPSC Notice)
  • Recall #05274 (2005-09-16): CPSC, Robertshaw Controls Co. Announce Recall of Gas Control Valves on Water Heaters (CPSC Notice)

How Do Five Nearby Hybrid/Electric Heat Pump Models Stack Up?

Five alternative Hybrid/Electric Heat Pump units with nearly identical gallon storage and UEF scores are listed below alongside exact efficiency spreads.

5 closest certified peers matched by equipment class, storage volume, and efficiency rating
Brand & ModelTypeVolFHRUEF (Δ)kWh/yr
Friedrich PROH80 T2 FD400-15 Hybrid/Electric Heat Pump 72 gal 67 gal 3.7 (at parity) 871
Rheem CPROPH80 T2 RH375-15 Hybrid/Electric Heat Pump 72 gal 67 gal 3.7 (at parity) 871
Richmond 10CE80-HP5U15 Hybrid/Electric Heat Pump 72 gal 67 gal 3.7 (at parity) 871
LG APHWC801D Hybrid/Electric Heat Pump 72 gal 94 gal 3.9 (+0.20) 1,272
Rheem CPROPH80 T2 RH400-15 Hybrid/Electric Heat Pump 72 gal 67 gal 3.7 (at parity) 871

When Should Homeowners Skip Ruud PROUH80 T2 CD400-15 (Hybrid/Electric Heat Pump)?

Check Ruud PROUH80 T2 CD400-15's mechanical constraints—including utility space, Electric capacity, and Pass: +1.20 / +48.0% status—against typical residential installations.

Key Limitations & Exclusions

  • Ruud PROUH80 T2 CD400-15 needs >=450 cu ft room air volume or ducting so compressor cooling does not stall recovery.
  • Compressor runs near 49 dBA; avoid mounting Ruud PROUH80 T2 CD400-15 directly beside quiet bedrooms.
  • Requires condensate drain routing and 240V electrical capacity; verify state DOE HEAR status.

Which Option Fits Your Situation?

High Electric Rate States Choosing Ruud PROUH80 T2 CD400-15 Strong Fit — 3.7 UEF trims electric use ~75% vs 0.92 UEF tanks.
Open Basement or Garage (>=450 cu ft) Strong Fit — Ample ambient air sustains heat-pump-only efficiency.
Small Interior Closet (<300 cu ft) Caution — Add duct kit or compare Friedrich PROH80 T2 FD400-15 footprint.

Frequently Asked Technical Questions: Ruud PROUH80 T2 CD400-15

Direct answers to common technical, regulatory, and sizing questions sourced from primary U.S. government and OEM documentation.

Will Ruud PROUH80 T2 CD400-15 stay compliant after the May 6, 2029 DOE standard takes effect?

Tested at 3.7 UEF, Ruud PROUH80 T2 CD400-15 shows Pass: +1.20 / +48.0% relative to May 6, 2029 federal DOE limits while placing #347 of 706 among 706 Hybrid/Electric Heat Pump peers like Friedrich PROH80 T2 FD400-15.

Will Ruud PROUH80 T2 CD400-15 fit through a standard utility door and 72-inch basement ceiling?

Measuring 74.2 in. tall by 24.3 in. diameter, Ruud PROUH80 T2 CD400-15 notes: needs >72 in. overhead clearance; clears 28 in. utility doorway (24.3" d). Reserve space above the jacket for T&P piping and anode removal.

Do existing utility hookups support Ruud PROUH80 T2 CD400-15 during replacement?

Electrical specs for Ruud PROUH80 T2 CD400-15 call for 240V at 12A max (Requires 240V dedicated branch circuit; check panel capacity). Have a licensed electrician inspect panel load and wire gauge.

What is the estimated 10-year operating spend for Ruud PROUH80 T2 CD400-15?

At 18.16 cents/kWh national residential pricing, Ruud PROUH80 T2 CD400-15's 871 kWh/yr draw equals roughly $158 annually or $1,580 across a 10-year horizon (ranging from $127/yr in Washington hydro tiers up to $411/yr in Hawaii).

When is Ruud PROUH80 T2 CD400-15 a poor fit for a residential replacement?

Avoid placing Ruud PROUH80 T2 CD400-15 directly next to bedrooms or inside tight <300 cu ft closets without ducting, due to 49 dBA sound and cool exhaust airflow.

What First Hour Rating or flow capacity does Ruud PROUH80 T2 CD400-15 deliver?

With 67 gal FHR (-5 gal vs. 72 gal median), Ruud PROUH80 T2 CD400-15 fits larger 3–5 person homes cleanly.

How do you verify manufacturing age and recall status on Ruud PROUH80 T2 CD400-15?

CPSC SaferProducts records show 2 brand-level recall notices mentioning Ruud as of 2026-11-23, including #07108 (2007-02-21). Enter the rating-plate serial into TapAndPipe's Serial Lookup tool to verify production week.

Does Ruud PROUH80 T2 CD400-15 qualify for DOE HEAR incentives after 25C expired?

After 25C sunset on Dec 31, 2025 under OBBBA, check state DOE HEAR (up to $1,750 income-qualified) and utility rebates for Ruud PROUH80 T2 CD400-15. Closest peer in Hybrid/Electric Heat Pump is Friedrich PROH80 T2 FD400-15 (3.7 UEF).

Sources

  1. ENERGY STAR Certified Water Heaters Dataset (Socrata pbpq-swnu) — U.S. EPA & DOE ENERGY STAR, 2026 Live Certified Registry (retrieved 2026-11-23)
  2. 10 CFR 430.32 — Energy and Water Conservation Standards (Water Heaters & Plumbing Fixtures) — U.S. Department of Energy / eCFR, 2026 eCFR (incl. May 6, 2029 Rule) (retrieved 2026-11-23)
  3. CPSC SaferProducts.gov Product Recalls REST API — U.S. Consumer Product Safety Commission, 2026 Live Recalls Feed (retrieved 2026-11-23)
  4. EIA Electric Power Monthly Table 5.6.A — Average Residential Electricity Price by State — U.S. Energy Information Administration (EIA), August 2026 Monthly Release (retrieved 2026-11-23)

Related U.S. Metro Plumbing Benchmarks