Rheem CXE80T10H22U1 Water Heater Specifications (3.7 UEF)
In the 706-unit Hybrid/Electric Heat Pump class, Rheem CXE80T10H22U1 (Electric) achieves a certified 3.7 UEF rating across its 72-gallon nominal tank, 67 gal First Hour Rating (rank #347 of 706, PD 3554239) and verifies as Pass: +1.20 / +48.0% for 2029 DOE floors. Rated annual electricity draw of 871 kWh/yr equates to roughly $158/yr ($1,582 over 10 years) at 18.16 cents/kWh. Closest certified alternative is Friedrich PROH80 T2 FD400-15 (3.7 UEF).
- Uniform Energy Factor
- 3.7 UEF
- Cohort UEF Rank
- #347 of 706
- First Hour Rating
- 67 gal
- Storage Volume
- 72 gal
- Fuel / Type
- Electric / Hybrid/Electric Heat Pump
- DOE 2029 Rule Status
- Pass: +1.20 / +48.0%

Rheem CXE80T10H22U1 records 3.7 UEF efficiency, putting it #347 of 706 among 706 Hybrid/Electric Heat Pump peers.
10 CFR 430.32(d)(2) compliance: Rheem CXE80T10H22U1 exceeds 10 CFR 430.32(d)(2) Electric >55 to <=120 gal (2.50 UEF) by +1.20 UEF (+48.0%). At EIA August 2026 national rates (18.16 cents/kWh), 871 kWh/yr for Rheem CXE80T10H22U1 runs ~$158/yr vs. ~$636/yr for a 0.92 UEF electric tank.
State electric sensitivity for Rheem CXE80T10H22U1: 10-year operating spend spans $1,274 in Washington (Lowest Hydro Tier) (14.63 cents/kWh) to $4,109 in Hawaii (Highest EIA State) (47.18 cents/kWh).
Competing options beside Rheem CXE80T10H22U1 (3.7 UEF) are Friedrich PROH80 T2 FD400-15 (3.7 UEF, at parity) and Richmond 10CE80-HP5U15 (3.7 UEF, at parity).
Where Does Rheem CXE80T10H22U1 Rank Against Peer Hybrid/Electric Heat Pump Units?
Audited against 706 ENERGY STAR Hybrid/Electric Heat Pump listings, Rheem CXE80T10H22U1 holds #347 of 706; inspect footprint, circuit load, and efficiency deltas here.
| Specification Attribute | Certified Value | Cohort Benchmark / Delta | Provenance |
|---|---|---|---|
| Manufacturer / Brand | Rheem | 236 certified listings | ENERGY STAR PD 3554239 |
| Model Number | CXE80T10H22U1 | Draw pattern: Medium-Usage | CXE80T10H22U1 |
| Uniform Energy Factor (UEF) | 3.7 | At 3.70 UEF median | 10 CFR 430 Test Method |
| First Hour Rating (FHR) | 67 gal | -5 gal vs. 72 gal median | 10 CFR 430 Recovery Test |
| Rated Annual Electricity Use | 871 kWh/yr | -201 kWh/yr vs. 1,072 kWh/yr median | Est. $158/yr @ $0.1816/kWh (EIA US Avg) |
| Thermal Recovery Efficiency | 445% | +16.0 pts vs. 429.0% median | ENERGY STAR Dataset |
| Physical Envelope (H x Dia) | 74.2" H x 24.3" D | Needs >72 in. overhead clearance; clears 28 in. utility doorway (24.3" D) | Doorway & ceiling check |
| Electrical Circuit Requirements | 240 V / 12 A max | Requires 240V dedicated branch circuit; check panel capacity | NEC / Branch circuit check |
| Heat Pump Refrigerant & GWP | R-134a (GWP:1430) | Check regional AIM Act phase-down transition | EPA AIM Act Compliance |
| Certification Date | 2026-10-15 | Certified 2026-10-15 | Markets: Canada |
How Much Electricity Does CXE80T10H22U1 Use in Different States?
Estimated at $158/yr nationally (871 kWh/yr), 10-year utility spending for Rheem CXE80T10H22U1 shifts sharply between low-rate hydro and coastal grids.
| Jurisdiction (EIA Aug 2026) | Residential Rate | Annual Cost | 10-Yr Operating Spend | 10-Yr Savings vs. 0.92 UEF |
|---|---|---|---|---|
| United States Average | 18.16 ¢/kWh ($0.1816) | $158/yr | $1,582 | $4,780 |
| Hawaii (Highest EIA State) | 47.18 ¢/kWh ($0.4718) | $411/yr | $4,109 | $12,418 |
| California | 29.75 ¢/kWh ($0.2975) | $259/yr | $2,591 | $7,830 |
| Texas | 15.91 ¢/kWh ($0.1591) | $139/yr | $1,386 | $4,188 |
| Washington (Lowest Hydro Tier) | 14.63 ¢/kWh ($0.1463) | $127/yr | $1,274 | $3,851 |
Does CPSC Flag Any Safety Notices on Rheem Units?
Checking 2026-11-23 SaferProducts data shows 4 notices mentioning Rheem; always cross-reference affected serial prefixes before ordering components. See Serial Number Lookup.
- Recall #16177 (2016-05-26): Rheem Recalls to Repair Water Heaters Due to Fire and Burn Hazards; Sold Exclusively at Home Depot (CPSC Notice)
- Recall #07108 (2007-02-21): Tankless Water Heaters Recalled for Repair Due to Carbon Monoxide Poisoning Hazard (CPSC Notice)
- Recall #05274 (2005-09-16): CPSC, Robertshaw Controls Co. Announce Recall of Gas Control Valves on Water Heaters (CPSC Notice)
- Recall #80042 (1980-12-04): LP Gas Water Heaters Repaired by White-Rodgers (CPSC Notice)
Which Competing Hybrid/Electric Heat Pump Models Compare Closest to CXE80T10H22U1?
Compare five nearby ENERGY STAR Hybrid/Electric Heat Pump options matched closely to Rheem CXE80T10H22U1's gallon capacity and 3.7 UEF efficiency.
| Brand & Model | Type | Vol | FHR | UEF (Δ) | kWh/yr |
|---|---|---|---|---|---|
| Friedrich PROH80 T2 FD400-15 | Hybrid/Electric Heat Pump | 72 gal | 67 gal | 3.7 (at parity) | 871 |
| Richmond 10CE80-HP5U15 | Hybrid/Electric Heat Pump | 72 gal | 67 gal | 3.7 (at parity) | 871 |
| Ruud PROUH80 T2 CD400-15 | Hybrid/Electric Heat Pump | 72 gal | 67 gal | 3.7 (at parity) | 871 |
| LG APHWC801D | Hybrid/Electric Heat Pump | 72 gal | 94 gal | 3.9 (+0.20) | 1,272 |
| Richmond 10E80-HP515 | Hybrid/Electric Heat Pump | 72 gal | 67 gal | 3.7 (at parity) | 871 |
When Should Homeowners Skip Rheem CXE80T10H22U1 (Hybrid/Electric Heat Pump)?
Check Rheem CXE80T10H22U1's mechanical constraints—including utility space, Electric capacity, and Pass: +1.20 / +48.0% status—against typical residential installations.
Key Limitations & Exclusions
- Rheem CXE80T10H22U1 needs >=450 cu ft room air volume or ducting so compressor cooling does not stall recovery.
- Compressor runs near 49 dBA; avoid mounting Rheem CXE80T10H22U1 directly beside quiet bedrooms.
- Requires condensate drain routing and 240V electrical capacity; verify state DOE HEAR status.
Which Option Fits Your Situation?
Common Homeowner Questions for Rheem CXE80T10H22U1
Direct answers to common technical, regulatory, and sizing questions sourced from primary U.S. government and OEM documentation.
Will Rheem CXE80T10H22U1 stay compliant after the May 6, 2029 DOE standard takes effect?
Tested at 3.7 UEF, Rheem CXE80T10H22U1 shows Pass: +1.20 / +48.0% relative to May 6, 2029 federal DOE limits while placing #347 of 706 among 706 Hybrid/Electric Heat Pump peers like Friedrich PROH80 T2 FD400-15.
Will Rheem CXE80T10H22U1 fit through a standard utility door and 72-inch basement ceiling?
Measuring 74.2 in. tall by 24.3 in. diameter, Rheem CXE80T10H22U1 notes: needs >72 in. overhead clearance; clears 28 in. utility doorway (24.3" d). Reserve space above the jacket for T&P piping and anode removal.
Do existing utility hookups support Rheem CXE80T10H22U1 during replacement?
Electrical specs for Rheem CXE80T10H22U1 call for 240V at 12A max (Requires 240V dedicated branch circuit; check panel capacity). Have a licensed electrician inspect panel load and wire gauge.
What is the estimated 10-year operating spend for Rheem CXE80T10H22U1?
At 18.16 cents/kWh national residential pricing, Rheem CXE80T10H22U1's 871 kWh/yr draw equals roughly $158 annually or $1,580 across a 10-year horizon (ranging from $127/yr in Washington hydro tiers up to $411/yr in Hawaii).
When is Rheem CXE80T10H22U1 a poor fit for a residential replacement?
Avoid placing Rheem CXE80T10H22U1 directly next to bedrooms or inside tight <300 cu ft closets without ducting, due to 49 dBA sound and cool exhaust airflow.
What First Hour Rating or flow capacity does Rheem CXE80T10H22U1 deliver?
With 67 gal FHR (-5 gal vs. 72 gal median), Rheem CXE80T10H22U1 fits larger 3–5 person homes cleanly.
How do you verify manufacturing age and recall status on Rheem CXE80T10H22U1?
CPSC SaferProducts records show 4 brand-level recall notices mentioning Rheem as of 2026-11-23, including #16177 (2016-05-26). Enter the rating-plate serial into TapAndPipe's Serial Lookup tool to verify production week.
Does Rheem CXE80T10H22U1 qualify for DOE HEAR incentives after 25C expired?
After 25C sunset on Dec 31, 2025 under OBBBA, check state DOE HEAR (up to $1,750 income-qualified) and utility rebates for Rheem CXE80T10H22U1. Closest peer in Hybrid/Electric Heat Pump is Friedrich PROH80 T2 FD400-15 (3.7 UEF).
Sources
- ENERGY STAR Certified Water Heaters Dataset (Socrata pbpq-swnu) — U.S. EPA & DOE ENERGY STAR, 2026 Live Certified Registry (retrieved 2026-11-23)
- 10 CFR 430.32 — Energy and Water Conservation Standards (Water Heaters & Plumbing Fixtures) — U.S. Department of Energy / eCFR, 2026 eCFR (incl. May 6, 2029 Rule) (retrieved 2026-11-23)
- CPSC SaferProducts.gov Product Recalls REST API — U.S. Consumer Product Safety Commission, 2026 Live Recalls Feed (retrieved 2026-11-23)
- EIA Electric Power Monthly Table 5.6.A — Average Residential Electricity Price by State — U.S. Energy Information Administration (EIA), August 2026 Monthly Release (retrieved 2026-11-23)