Skip to main content
ENERGY STAR water heater model · PD 3554253

Rheem CXE80T10H45U1 Water Heater Specifications (4.07 UEF)

With PD 3554253 certification, Rheem CXE80T10H45U1 (Hybrid/Electric Heat Pump, Electric) achieves a certified 4.07 UEF rating across its 72-gallon nominal tank, 87 gal First Hour Rating, standing #26 of 706 across 706 peers with Pass: +1.57 / +62.8% for May 6, 2029. Rated annual electricity draw of 1,213 kWh/yr equates to roughly $220/yr ($2,203 over 10 years) at 18.16 cents/kWh. Closest certified alternative is Friedrich PROH80 T2 FD400-30 (4.07 UEF).

Uniform Energy Factor
4.07 UEF
Cohort UEF Rank
#26 of 706 (top 8.5%)
First Hour Rating
87 gal
Storage Volume
72 gal
Fuel / Type
Electric / Hybrid/Electric Heat Pump
DOE 2029 Rule Status
Pass: +1.57 / +62.8%
Hybrid heat pump water heater upper shroud with brass relief valve and insulated copper risers
Hybrid heat pump water heater upper shroud with brass relief valve and insulated copper risers
Hybrid/Electric Heat Pump UEF Efficiency Distribution (706 Certified Units)Distribution of certified UEF ratings across 706 units in Hybrid/Electric Heat Pump, marking Rheem CXE80T10H45U1 at 4.07 UEF.21130201631342031241542.52 UEF4.50 UEFMedian 3.702029 min 2.50Rheem CXE80T10H45U1: 4.07
Hybrid/Electric Heat Pump UEF Efficiency Distribution (706 Certified Units). Highlighted pin shows Rheem CXE80T10H45U1 relative to the cohort median.
Efficiency comparison & rule summary

ENERGY STAR certification places Rheem CXE80T10H45U1 at 4.07 UEF (#26 of 706; +0.37 UEF vs. 3.70 UEF median) in Hybrid/Electric Heat Pump.

May 6, 2029 readiness: Rheem CXE80T10H45U1 stands +1.57 UEF (+62.8%) relative to 10 CFR 430.32(d)(2) Electric >55 to <=120 gal (2.50 UEF). At EIA August 2026 national rates (18.16 cents/kWh), 1,213 kWh/yr for Rheem CXE80T10H45U1 runs ~$220/yr vs. ~$974/yr for a 0.92 UEF electric tank.

State electric sensitivity for Rheem CXE80T10H45U1: 10-year operating spend spans $1,775 in Washington (Lowest Hydro Tier) (14.63 cents/kWh) to $5,723 in Hawaii (Highest EIA State) (47.18 cents/kWh).

In the Hybrid/Electric Heat Pump tier, Friedrich PROH80 T2 FD400-30 (4.07 UEF, at parity) and Richmond 10CE80-HP5S30 (4.07 UEF, at parity) bracket Rheem CXE80T10H45U1.

What Physical and Thermal Ratings Define Rheem CXE80T10H45U1?

Positioning at #26 of 706 (top 8.5%) out of 706 Hybrid/Electric Heat Pump peers, Rheem CXE80T10H45U1 pairs measured UEF performance with specific clearance and wiring rules.

Certified model attributes compared against 706 ENERGY STAR Hybrid/Electric Heat Pump peers
Specification AttributeCertified ValueCohort Benchmark / DeltaProvenance
Manufacturer / BrandRheem236 certified listingsENERGY STAR PD 3554253
Model NumberCXE80T10H45U1Draw pattern: High-UsageCXE80T10H45U1
Uniform Energy Factor (UEF)4.07+0.37 UEF vs. 3.70 UEF median10 CFR 430 Test Method
First Hour Rating (FHR)87 gal+15 gal vs. 72 gal median10 CFR 430 Recovery Test
Rated Annual Electricity Use1,213 kWh/yr+141 kWh/yr vs. 1,072 kWh/yr medianEst. $220/yr @ $0.1816/kWh (EIA US Avg)
Thermal Recovery Efficiency447%+18.0 pts vs. 429.0% medianENERGY STAR Dataset
Physical Envelope (H x Dia)74.2" H x 24.3" DNeeds >72 in. overhead clearance; clears 28 in. utility doorway (24.3" D)Doorway & ceiling check
Electrical Circuit Requirements240 V / 21 A maxRequires 240V dedicated branch circuit; check panel capacityNEC / Branch circuit check
Heat Pump Refrigerant & GWPR-134a (GWP:1430)Check regional AIM Act phase-down transitionEPA AIM Act Compliance
Certification Date2026-10-15Certified 2026-10-15Markets: Canada

Why Do State Utility Rates Shift CXE80T10H45U1 Running Costs?

Consuming 1,213 kWh annually puts Rheem CXE80T10H45U1 near $220/yr at US baseline tariffs, with multi-state EIA comparisons charted below.

Estimated Annual Electricity Cost by State Rate (1,213 kWh/yr)Projected annual electricity spend across five benchmark EIA August 2026 residential electric tiers.United States Average$220.00/yrHawaii$572.00/yrCalifornia$361.00/yrTexas$193.00/yrWashington$177.00/yr
Projected annual electricity spend across five benchmark EIA August 2026 residential electric tiers.
Estimated electricity cost and 10-year spend across benchmark states
Jurisdiction (EIA Aug 2026)Residential RateAnnual Cost10-Yr Operating Spend10-Yr Savings vs. 0.92 UEF
United States Average 18.16 ¢/kWh ($0.1816) $220/yr $2,203 $7,542
Hawaii (Highest EIA State) 47.18 ¢/kWh ($0.4718) $572/yr $5,723 $19,594
California 29.75 ¢/kWh ($0.2975) $361/yr $3,609 $12,355
Texas 15.91 ¢/kWh ($0.1591) $193/yr $1,930 $6,607
Washington (Lowest Hydro Tier) 14.63 ¢/kWh ($0.1463) $177/yr $1,775 $6,076
Estimated electricity spend (1,213 kWh/yr)

Condensing Gas Tankless vs. Storage Tank Flow Path & Gas Supply Engineering schematic contrasting 199,000 BTU/h condensing tankless piping (3/4 in. gas supply, Category IV PVC vent, condensate drain) against a 40,000 BTU/h atmospheric tank. Condensing Gas Tankless (0.91–0.96 UEF) Secondary HX Cat IV PVC Vent Cold In Hot Out 3/4"–1" Gas 199K BTU/h Condensate Atmospheric Storage Tank (0.58–0.65 UEF) Type B Flue Anode Rod 40K BTU/h 1/2" Gas Up to 100 ft T&P 150 psi 50–85 gal FHR Reserve | 8–12 yr life
Technical comparison: condensing gas tankless units require 3/4 in.–1 in. IFGC Table 402.4 gas supply and Category IV condensate drainage, while atmospheric tanks run on 1/2 in. lines.

Have Any Rheem Series Triggered CPSC Recalls?

SaferProducts records retrieved 2026-11-23 list 4 brand notices under Rheem; inspect model coverage dates prior to valve or anode service. See Serial Number Lookup.

4 Brand Recall Notices Found in CPSC Feed — Verify Serial & Model Range
  • Recall #16177 (2016-05-26): Rheem Recalls to Repair Water Heaters Due to Fire and Burn Hazards; Sold Exclusively at Home Depot (CPSC Notice)
  • Recall #07108 (2007-02-21): Tankless Water Heaters Recalled for Repair Due to Carbon Monoxide Poisoning Hazard (CPSC Notice)
  • Recall #05274 (2005-09-16): CPSC, Robertshaw Controls Co. Announce Recall of Gas Control Valves on Water Heaters (CPSC Notice)
  • Recall #80042 (1980-12-04): LP Gas Water Heaters Repaired by White-Rodgers (CPSC Notice)

What Are 5 Direct Alternatives to Rheem CXE80T10H45U1?

Homeowners cross-shopping Rheem CXE80T10H45U1 frequently review these five Hybrid/Electric Heat Pump models ranked closest on capacity and UEF output.

5 closest certified peers matched by equipment class, storage volume, and efficiency rating
Brand & ModelTypeVolFHRUEF (Δ)kWh/yr
Friedrich PROH80 T2 FD400-30 Hybrid/Electric Heat Pump 72 gal 87 gal 4.07 (at parity) 1,213
Richmond 10CE80-HP5S30 Hybrid/Electric Heat Pump 72 gal 87 gal 4.07 (at parity) 1,213
Ruud CPROPH80 T2 CD375-30 Hybrid/Electric Heat Pump 72 gal 87 gal 4.07 (at parity) 1,213
LG APHWC802D Hybrid/Electric Heat Pump 72 gal 91 gal 4.1 (+0.03) 1,210
Friedrich PROH80 T2 FD400-SO Hybrid/Electric Heat Pump 72 gal 87 gal 4.07 (at parity) 1,213

What Installation Caveats Apply Before Buying Rheem CXE80T10H45U1?

Even high-UEF units like Rheem CXE80T10H45U1 (4.07 UEF) carry physical space, condensate, and fuel-line prerequisites noted below.

Key Limitations & Exclusions

  • Rheem CXE80T10H45U1 needs >=450 cu ft room air volume or ducting so compressor cooling does not stall recovery.
  • Compressor runs near 49 dBA; avoid mounting Rheem CXE80T10H45U1 directly beside quiet bedrooms.
  • Requires condensate drain routing and 240V electrical capacity; verify state DOE HEAR status.

Which Option Fits Your Situation?

High Electric Rate States Choosing Rheem CXE80T10H45U1 Strong Fit — 4.07 UEF trims electric use ~75% vs 0.92 UEF tanks.
Open Basement or Garage (>=450 cu ft) Strong Fit — Ample ambient air sustains heat-pump-only efficiency.
Small Interior Closet (<300 cu ft) Caution — Add duct kit or compare Friedrich PROH80 T2 FD400-30 footprint.

Sizing, Efficiency & Recall Answers for Rheem CXE80T10H45U1

Direct answers to common technical, regulatory, and sizing questions sourced from primary U.S. government and OEM documentation.

Is Rheem CXE80T10H45U1 eligible for continued manufacture past May 6, 2029?

At 4.07 UEF, Rheem CXE80T10H45U1 achieves Pass: +1.57 / +62.8% for the 2029 DOE standard and stands #26 of 706 (top 8.5%) against Friedrich PROH80 T2 FD400-30 and Richmond 10CE80-HP5S30.

How tall and wide is Rheem CXE80T10H45U1, and what service clearance is needed?

Physical dimensions for Rheem CXE80T10H45U1 are 74.2 in. height and 24.3 in. diameter (needs >72 in. overhead clearance; clears 28 in. utility doorway (24.3" d)); verify stair turns and drain pan width before delivery.

Will Rheem CXE80T10H45U1 require upgrading household electrical panels or gas piping?

Rheem CXE80T10H45U1 draws 240V at 21A max (Requires 240V dedicated branch circuit; check panel capacity); check whether existing 10/2 AWG 30A copper wiring aligns with nameplate amps.

Is Rheem CXE80T10H45U1 economical to operate at 18.16 cents/kWh US electric rates?

Expect roughly $220/yr ($2,200 over 10 years) to power Rheem CXE80T10H45U1 at 1,213 kWh/yr under the 18.16 cents/kWh US average (ranging from $177/yr in Washington hydro tiers up to $572/yr in Hawaii).

Which installation bottlenecks limit Rheem CXE80T10H45U1?

If ambient room air stays below 40 °F year-round or closet volume falls under 450 cu ft, Rheem CXE80T10H45U1 drops into resistance mode more often.

How does Rheem CXE80T10H45U1 handle simultaneous showers and laundry?

Delivering 87 gal in the first hour (+15 gal vs. 72 gal median), Rheem CXE80T10H45U1 combines 72 gal tank storage with rapid burner/element recovery.

How long is the warranty on Rheem CXE80T10H45U1 and how do you decode its serial?

CPSC SaferProducts records show 4 brand-level recall notices mentioning Rheem as of 2026-11-23, including #16177 (2016-05-26). Enter the rating-plate serial into TapAndPipe's Serial Lookup tool to verify production week.

How do 2026 post-OBBBA rebates affect buying Rheem CXE80T10H45U1?

Check state energy office HEAR portals and utility rebates in 2026 since federal 25C ended Dec 31, 2025. Closest peer in Hybrid/Electric Heat Pump is Friedrich PROH80 T2 FD400-30 (4.07 UEF).

Sources

  1. ENERGY STAR Certified Water Heaters Dataset (Socrata pbpq-swnu) — U.S. EPA & DOE ENERGY STAR, 2026 Live Certified Registry (retrieved 2026-11-23)
  2. 10 CFR 430.32 — Energy and Water Conservation Standards (Water Heaters & Plumbing Fixtures) — U.S. Department of Energy / eCFR, 2026 eCFR (incl. May 6, 2029 Rule) (retrieved 2026-11-23)
  3. CPSC SaferProducts.gov Product Recalls REST API — U.S. Consumer Product Safety Commission, 2026 Live Recalls Feed (retrieved 2026-11-23)
  4. EIA Electric Power Monthly Table 5.6.A — Average Residential Electricity Price by State — U.S. Energy Information Administration (EIA), August 2026 Monthly Release (retrieved 2026-11-23)

Related U.S. Metro Plumbing Benchmarks