Rheem CXE80T10H45U1 Water Heater Specifications (4.07 UEF)
With PD 3554253 certification, Rheem CXE80T10H45U1 (Hybrid/Electric Heat Pump, Electric) achieves a certified 4.07 UEF rating across its 72-gallon nominal tank, 87 gal First Hour Rating, standing #26 of 706 across 706 peers with Pass: +1.57 / +62.8% for May 6, 2029. Rated annual electricity draw of 1,213 kWh/yr equates to roughly $220/yr ($2,203 over 10 years) at 18.16 cents/kWh. Closest certified alternative is Friedrich PROH80 T2 FD400-30 (4.07 UEF).
- Uniform Energy Factor
- 4.07 UEF
- Cohort UEF Rank
- #26 of 706 (top 8.5%)
- First Hour Rating
- 87 gal
- Storage Volume
- 72 gal
- Fuel / Type
- Electric / Hybrid/Electric Heat Pump
- DOE 2029 Rule Status
- Pass: +1.57 / +62.8%

ENERGY STAR certification places Rheem CXE80T10H45U1 at 4.07 UEF (#26 of 706; +0.37 UEF vs. 3.70 UEF median) in Hybrid/Electric Heat Pump.
May 6, 2029 readiness: Rheem CXE80T10H45U1 stands +1.57 UEF (+62.8%) relative to 10 CFR 430.32(d)(2) Electric >55 to <=120 gal (2.50 UEF). At EIA August 2026 national rates (18.16 cents/kWh), 1,213 kWh/yr for Rheem CXE80T10H45U1 runs ~$220/yr vs. ~$974/yr for a 0.92 UEF electric tank.
State electric sensitivity for Rheem CXE80T10H45U1: 10-year operating spend spans $1,775 in Washington (Lowest Hydro Tier) (14.63 cents/kWh) to $5,723 in Hawaii (Highest EIA State) (47.18 cents/kWh).
In the Hybrid/Electric Heat Pump tier, Friedrich PROH80 T2 FD400-30 (4.07 UEF, at parity) and Richmond 10CE80-HP5S30 (4.07 UEF, at parity) bracket Rheem CXE80T10H45U1.
What Physical and Thermal Ratings Define Rheem CXE80T10H45U1?
Positioning at #26 of 706 (top 8.5%) out of 706 Hybrid/Electric Heat Pump peers, Rheem CXE80T10H45U1 pairs measured UEF performance with specific clearance and wiring rules.
| Specification Attribute | Certified Value | Cohort Benchmark / Delta | Provenance |
|---|---|---|---|
| Manufacturer / Brand | Rheem | 236 certified listings | ENERGY STAR PD 3554253 |
| Model Number | CXE80T10H45U1 | Draw pattern: High-Usage | CXE80T10H45U1 |
| Uniform Energy Factor (UEF) | 4.07 | +0.37 UEF vs. 3.70 UEF median | 10 CFR 430 Test Method |
| First Hour Rating (FHR) | 87 gal | +15 gal vs. 72 gal median | 10 CFR 430 Recovery Test |
| Rated Annual Electricity Use | 1,213 kWh/yr | +141 kWh/yr vs. 1,072 kWh/yr median | Est. $220/yr @ $0.1816/kWh (EIA US Avg) |
| Thermal Recovery Efficiency | 447% | +18.0 pts vs. 429.0% median | ENERGY STAR Dataset |
| Physical Envelope (H x Dia) | 74.2" H x 24.3" D | Needs >72 in. overhead clearance; clears 28 in. utility doorway (24.3" D) | Doorway & ceiling check |
| Electrical Circuit Requirements | 240 V / 21 A max | Requires 240V dedicated branch circuit; check panel capacity | NEC / Branch circuit check |
| Heat Pump Refrigerant & GWP | R-134a (GWP:1430) | Check regional AIM Act phase-down transition | EPA AIM Act Compliance |
| Certification Date | 2026-10-15 | Certified 2026-10-15 | Markets: Canada |
Why Do State Utility Rates Shift CXE80T10H45U1 Running Costs?
Consuming 1,213 kWh annually puts Rheem CXE80T10H45U1 near $220/yr at US baseline tariffs, with multi-state EIA comparisons charted below.
| Jurisdiction (EIA Aug 2026) | Residential Rate | Annual Cost | 10-Yr Operating Spend | 10-Yr Savings vs. 0.92 UEF |
|---|---|---|---|---|
| United States Average | 18.16 ¢/kWh ($0.1816) | $220/yr | $2,203 | $7,542 |
| Hawaii (Highest EIA State) | 47.18 ¢/kWh ($0.4718) | $572/yr | $5,723 | $19,594 |
| California | 29.75 ¢/kWh ($0.2975) | $361/yr | $3,609 | $12,355 |
| Texas | 15.91 ¢/kWh ($0.1591) | $193/yr | $1,930 | $6,607 |
| Washington (Lowest Hydro Tier) | 14.63 ¢/kWh ($0.1463) | $177/yr | $1,775 | $6,076 |
Have Any Rheem Series Triggered CPSC Recalls?
SaferProducts records retrieved 2026-11-23 list 4 brand notices under Rheem; inspect model coverage dates prior to valve or anode service. See Serial Number Lookup.
- Recall #16177 (2016-05-26): Rheem Recalls to Repair Water Heaters Due to Fire and Burn Hazards; Sold Exclusively at Home Depot (CPSC Notice)
- Recall #07108 (2007-02-21): Tankless Water Heaters Recalled for Repair Due to Carbon Monoxide Poisoning Hazard (CPSC Notice)
- Recall #05274 (2005-09-16): CPSC, Robertshaw Controls Co. Announce Recall of Gas Control Valves on Water Heaters (CPSC Notice)
- Recall #80042 (1980-12-04): LP Gas Water Heaters Repaired by White-Rodgers (CPSC Notice)
What Are 5 Direct Alternatives to Rheem CXE80T10H45U1?
Homeowners cross-shopping Rheem CXE80T10H45U1 frequently review these five Hybrid/Electric Heat Pump models ranked closest on capacity and UEF output.
| Brand & Model | Type | Vol | FHR | UEF (Δ) | kWh/yr |
|---|---|---|---|---|---|
| Friedrich PROH80 T2 FD400-30 | Hybrid/Electric Heat Pump | 72 gal | 87 gal | 4.07 (at parity) | 1,213 |
| Richmond 10CE80-HP5S30 | Hybrid/Electric Heat Pump | 72 gal | 87 gal | 4.07 (at parity) | 1,213 |
| Ruud CPROPH80 T2 CD375-30 | Hybrid/Electric Heat Pump | 72 gal | 87 gal | 4.07 (at parity) | 1,213 |
| LG APHWC802D | Hybrid/Electric Heat Pump | 72 gal | 91 gal | 4.1 (+0.03) | 1,210 |
| Friedrich PROH80 T2 FD400-SO | Hybrid/Electric Heat Pump | 72 gal | 87 gal | 4.07 (at parity) | 1,213 |
What Installation Caveats Apply Before Buying Rheem CXE80T10H45U1?
Even high-UEF units like Rheem CXE80T10H45U1 (4.07 UEF) carry physical space, condensate, and fuel-line prerequisites noted below.
Key Limitations & Exclusions
- Rheem CXE80T10H45U1 needs >=450 cu ft room air volume or ducting so compressor cooling does not stall recovery.
- Compressor runs near 49 dBA; avoid mounting Rheem CXE80T10H45U1 directly beside quiet bedrooms.
- Requires condensate drain routing and 240V electrical capacity; verify state DOE HEAR status.
Which Option Fits Your Situation?
Sizing, Efficiency & Recall Answers for Rheem CXE80T10H45U1
Direct answers to common technical, regulatory, and sizing questions sourced from primary U.S. government and OEM documentation.
Is Rheem CXE80T10H45U1 eligible for continued manufacture past May 6, 2029?
At 4.07 UEF, Rheem CXE80T10H45U1 achieves Pass: +1.57 / +62.8% for the 2029 DOE standard and stands #26 of 706 (top 8.5%) against Friedrich PROH80 T2 FD400-30 and Richmond 10CE80-HP5S30.
How tall and wide is Rheem CXE80T10H45U1, and what service clearance is needed?
Physical dimensions for Rheem CXE80T10H45U1 are 74.2 in. height and 24.3 in. diameter (needs >72 in. overhead clearance; clears 28 in. utility doorway (24.3" d)); verify stair turns and drain pan width before delivery.
Will Rheem CXE80T10H45U1 require upgrading household electrical panels or gas piping?
Rheem CXE80T10H45U1 draws 240V at 21A max (Requires 240V dedicated branch circuit; check panel capacity); check whether existing 10/2 AWG 30A copper wiring aligns with nameplate amps.
Is Rheem CXE80T10H45U1 economical to operate at 18.16 cents/kWh US electric rates?
Expect roughly $220/yr ($2,200 over 10 years) to power Rheem CXE80T10H45U1 at 1,213 kWh/yr under the 18.16 cents/kWh US average (ranging from $177/yr in Washington hydro tiers up to $572/yr in Hawaii).
Which installation bottlenecks limit Rheem CXE80T10H45U1?
If ambient room air stays below 40 °F year-round or closet volume falls under 450 cu ft, Rheem CXE80T10H45U1 drops into resistance mode more often.
How does Rheem CXE80T10H45U1 handle simultaneous showers and laundry?
Delivering 87 gal in the first hour (+15 gal vs. 72 gal median), Rheem CXE80T10H45U1 combines 72 gal tank storage with rapid burner/element recovery.
How long is the warranty on Rheem CXE80T10H45U1 and how do you decode its serial?
CPSC SaferProducts records show 4 brand-level recall notices mentioning Rheem as of 2026-11-23, including #16177 (2016-05-26). Enter the rating-plate serial into TapAndPipe's Serial Lookup tool to verify production week.
How do 2026 post-OBBBA rebates affect buying Rheem CXE80T10H45U1?
Check state energy office HEAR portals and utility rebates in 2026 since federal 25C ended Dec 31, 2025. Closest peer in Hybrid/Electric Heat Pump is Friedrich PROH80 T2 FD400-30 (4.07 UEF).
Sources
- ENERGY STAR Certified Water Heaters Dataset (Socrata pbpq-swnu) — U.S. EPA & DOE ENERGY STAR, 2026 Live Certified Registry (retrieved 2026-11-23)
- 10 CFR 430.32 — Energy and Water Conservation Standards (Water Heaters & Plumbing Fixtures) — U.S. Department of Energy / eCFR, 2026 eCFR (incl. May 6, 2029 Rule) (retrieved 2026-11-23)
- CPSC SaferProducts.gov Product Recalls REST API — U.S. Consumer Product Safety Commission, 2026 Live Recalls Feed (retrieved 2026-11-23)
- EIA Electric Power Monthly Table 5.6.A — Average Residential Electricity Price by State — U.S. Energy Information Administration (EIA), August 2026 Monthly Release (retrieved 2026-11-23)