Rheem ECE H40 T2 RH310BM Water Heater Specifications (3.5 UEF)
Engineered as a Electric Hybrid/Electric Heat Pump unit, Rheem ECE H40 T2 RH310BM achieves a certified 3.5 UEF rating across its 36-gallon nominal tank, 60 gal First Hour Rating and ranks #481 of 706 in its 706-model cohort (PD 2408552), recording Pass: +1.20 / +52.2% under 2029 DOE rules. Rated annual electricity draw of 879 kWh/yr equates to roughly $160/yr ($1,596 over 10 years) at 18.16 cents/kWh. Closest certified alternative is Friedrich PROH40 T2 FD310BM (3.5 UEF).
- Uniform Energy Factor
- 3.5 UEF
- Cohort UEF Rank
- #481 of 706
- First Hour Rating
- 60 gal
- Storage Volume
- 36 gal
- Fuel / Type
- Electric / Hybrid/Electric Heat Pump
- DOE 2029 Rule Status
- Pass: +1.20 / +52.2%

Within the 706-unit Hybrid/Electric Heat Pump cohort, Rheem ECE H40 T2 RH310BM logs 3.5 UEF and ranks #481 of 706.
Against 10 CFR 430.32(d)(2) Electric >35 to <=55 gal (2.30 UEF), Rheem ECE H40 T2 RH310BM holds a +1.20 UEF (+52.2%) compliance cushion. At EIA August 2026 national rates (18.16 cents/kWh), 879 kWh/yr for Rheem ECE H40 T2 RH310BM runs ~$160/yr vs. ~$607/yr for a 0.92 UEF electric tank.
State electric sensitivity for Rheem ECE H40 T2 RH310BM: 10-year operating spend spans $1,286 in Washington (Lowest Hydro Tier) (14.63 cents/kWh) to $4,147 in Hawaii (Highest EIA State) (47.18 cents/kWh).
Cross-shopping Rheem ECE H40 T2 RH310BM (3.5 UEF)? Check Friedrich PROH40 T2 FD310BM (3.5 UEF, at parity) and Ruud PRO H40 T2 RU310BM (3.5 UEF, at parity).
How Do Rheem ECE H40 T2 RH310BM Specs Compare to Hybrid/Electric Heat Pump Medians?
Rheem ECE H40 T2 RH310BM places #481 of 706 across 706 certified Hybrid/Electric Heat Pump configurations, with physical dimensions, draw profile, and thermal metrics benchmarked below.
| Specification Attribute | Certified Value | Cohort Benchmark / Delta | Provenance |
|---|---|---|---|
| Manufacturer / Brand | Rheem | 236 certified listings | ENERGY STAR PD 2408552 |
| Model Number | ECE H40 T2 RH310BM | Draw pattern: Medium-Usage | ECE H40 T2 RH310BM |
| Uniform Energy Factor (UEF) | 3.5 | -0.20 UEF vs. 3.70 UEF median | 10 CFR 430 Test Method |
| First Hour Rating (FHR) | 60 gal | -12 gal vs. 72 gal median | 10 CFR 430 Recovery Test |
| Rated Annual Electricity Use | 879 kWh/yr | -193 kWh/yr vs. 1,072 kWh/yr median | Est. $160/yr @ $0.1816/kWh (EIA US Avg) |
| Thermal Recovery Efficiency | 430% | +1.0 pts vs. 429.0% median | ENERGY STAR Dataset |
| Physical Envelope (H x Dia) | 62.3" H x 20.3" D | Fits standard 72 in. basement/garage clearance; clears 28 in. utility doorway (20.3" D) | Doorway & ceiling check |
| Electrical Circuit Requirements | 240 V / 21 A max | Requires 240V dedicated branch circuit; check panel capacity | NEC / Branch circuit check |
| Heat Pump Refrigerant & GWP | R-134a (GWP:1430) | Check regional AIM Act phase-down transition | EPA AIM Act Compliance |
| Certification Date | 2026-10-15 | Certified 2026-10-15 | Markets: Canada |
What Does ECE H40 T2 RH310BM Cost to Operate Across State Electricity Rates?
At 879 kWh/yr, Rheem ECE H40 T2 RH310BM runs roughly $160/yr on the EIA national average tier under August 2026 Table 5.6.A rates.
| Jurisdiction (EIA Aug 2026) | Residential Rate | Annual Cost | 10-Yr Operating Spend | 10-Yr Savings vs. 0.92 UEF |
|---|---|---|---|---|
| United States Average | 18.16 ¢/kWh ($0.1816) | $160/yr | $1,596 | $4,476 |
| Hawaii (Highest EIA State) | 47.18 ¢/kWh ($0.4718) | $415/yr | $4,147 | $11,630 |
| California | 29.75 ¢/kWh ($0.2975) | $262/yr | $2,615 | $7,333 |
| Texas | 15.91 ¢/kWh ($0.1591) | $140/yr | $1,398 | $3,922 |
| Washington (Lowest Hydro Tier) | 14.63 ¢/kWh ($0.1463) | $129/yr | $1,286 | $3,606 |
Are There Active CPSC Safety Recalls for Rheem Water Heaters?
Our 2026-11-23 CPSC SaferProducts query surfaced 4 brand-level recall notices associated with Rheem; match your serial plate before repair. See Serial Number Lookup.
- Recall #16177 (2016-05-26): Rheem Recalls to Repair Water Heaters Due to Fire and Burn Hazards; Sold Exclusively at Home Depot (CPSC Notice)
- Recall #07108 (2007-02-21): Tankless Water Heaters Recalled for Repair Due to Carbon Monoxide Poisoning Hazard (CPSC Notice)
- Recall #05274 (2005-09-16): CPSC, Robertshaw Controls Co. Announce Recall of Gas Control Valves on Water Heaters (CPSC Notice)
- Recall #80042 (1980-12-04): LP Gas Water Heaters Repaired by White-Rodgers (CPSC Notice)
Which Certified Water Heaters Match ECE H40 T2 RH310BM Most Closely?
These 5 competing Hybrid/Electric Heat Pump units sit nearest to Rheem ECE H40 T2 RH310BM by storage capacity and 3.5 UEF rating.
| Brand & Model | Type | Vol | FHR | UEF (Δ) | kWh/yr |
|---|---|---|---|---|---|
| Friedrich PROH40 T2 FD310BM | Hybrid/Electric Heat Pump | 36 gal | 60 gal | 3.5 (at parity) | 879 |
| Ruud PRO H40 T2 RU310BM | Hybrid/Electric Heat Pump | 36 gal | 60 gal | 3.5 (at parity) | 879 |
| Richmond 10CE40-HP5U15 | Hybrid/Electric Heat Pump | 36 gal | 46 gal | 3.45 (-0.05) | 643 |
| A. O. Smith CAHP-40 2** | Hybrid/Electric Heat Pump | 36 gal | 55 gal | 3.6 (+0.10) | 902 |
| Friedrich PROH40 T2 FD310UM | Hybrid/Electric Heat Pump | 36 gal | 60 gal | 3.5 (at parity) | 879 |
Which Home Setups Are NOT a Fit for Rheem ECE H40 T2 RH310BM?
Comparing Rheem ECE H40 T2 RH310BM against Friedrich PROH40 T2 FD310BM requires checking closet airflow, IFGC gas or 240V electrical sizing, and May 6, 2029 compliance.
Key Limitations & Exclusions
- Rheem ECE H40 T2 RH310BM needs >=450 cu ft room air volume or ducting so compressor cooling does not stall recovery.
- Compressor runs near 49 dBA; avoid mounting Rheem ECE H40 T2 RH310BM directly beside quiet bedrooms.
- Requires condensate drain routing and 240V electrical capacity; verify state DOE HEAR status.
Which Option Fits Your Situation?
What Are the Key Questions About Rheem ECE H40 T2 RH310BM?
Direct answers to common technical, regulatory, and sizing questions sourced from primary U.S. government and OEM documentation.
How does Rheem ECE H40 T2 RH310BM score under 10 CFR 430.32 May 2029 water heater minimums?
Federal 10 CFR 430.32 rules set the May 6, 2029 manufacturing baseline; Rheem ECE H40 T2 RH310BM logs 3.5 UEF (Pass: +1.20 / +52.2%) within the 706-unit Hybrid/Electric Heat Pump group.
What physical clearance dimensions apply when installing Rheem ECE H40 T2 RH310BM?
With a 62.3 in. height and 20.3 in. diameter, Rheem ECE H40 T2 RH310BM fits spaces matching: fits standard 72 in. basement/garage clearance; clears 28 in. utility doorway (20.3" d), plus 6–12 in. above for plumbing shutoffs.
What 240V circuit or IFGC fuel line capacity fits Rheem ECE H40 T2 RH310BM?
Powered via 240V at 21A max, Rheem ECE H40 T2 RH310BM requires: Requires 240V dedicated branch circuit; check panel capacity. Confirm double-pole breaker sizing and condensate pump outlet proximity.
How do state electricity prices change annual costs for Rheem ECE H40 T2 RH310BM?
Annual electric spend for Rheem ECE H40 T2 RH310BM (879 kWh/yr) averages $160/yr nationwide (ranging from $129/yr in Washington hydro tiers up to $415/yr in Hawaii), calculated directly from August 2026 EIA Table 5.6.A tariffs.
What homeowner setups should avoid choosing Rheem ECE H40 T2 RH310BM?
Homes lacking a condensate drain or 240V branch circuit—or unconditioned sub-zero spaces—should verify hybrid backup mode limits on Rheem ECE H40 T2 RH310BM.
Is Rheem ECE H40 T2 RH310BM sized adequately for a 2-to-4-person household?
ENERGY STAR certifies Rheem ECE H40 T2 RH310BM at 60 gal First Hour Rating (-12 gal vs. 72 gal median); match that hourly reserve against simultaneous 2.0 GPM showerheads.
Does Rheem have active CPSC SaferProducts notices affecting ECE H40 T2 RH310BM?
CPSC SaferProducts records show 4 brand-level recall notices mentioning Rheem as of 2026-11-23, including #16177 (2016-05-26). Enter the rating-plate serial into TapAndPipe's Serial Lookup tool to verify production week.
Which competing water heater matches Rheem ECE H40 T2 RH310BM (3.5 UEF) most closely?
State-run DOE HEAR programs (<=150% AMI, up to $1,750 for HPWH) and electric utilities lead 2026 incentives for Rheem ECE H40 T2 RH310BM. Closest peer in Hybrid/Electric Heat Pump is Friedrich PROH40 T2 FD310BM (3.5 UEF).
Sources
- ENERGY STAR Certified Water Heaters Dataset (Socrata pbpq-swnu) — U.S. EPA & DOE ENERGY STAR, 2026 Live Certified Registry (retrieved 2026-11-23)
- 10 CFR 430.32 — Energy and Water Conservation Standards (Water Heaters & Plumbing Fixtures) — U.S. Department of Energy / eCFR, 2026 eCFR (incl. May 6, 2029 Rule) (retrieved 2026-11-23)
- CPSC SaferProducts.gov Product Recalls REST API — U.S. Consumer Product Safety Commission, 2026 Live Recalls Feed (retrieved 2026-11-23)
- EIA Electric Power Monthly Table 5.6.A — Average Residential Electricity Price by State — U.S. Energy Information Administration (EIA), August 2026 Monthly Release (retrieved 2026-11-23)