Skip to main content
ENERGY STAR water heater model · PD 3554174

Rheem ECEPH40 T2 RH400-15 Water Heater Specifications (3.45 UEF)

In the 706-unit Hybrid/Electric Heat Pump class, Rheem ECEPH40 T2 RH400-15 (Electric) achieves a certified 3.45 UEF rating across its 36-gallon nominal tank, 46 gal First Hour Rating (rank #563 of 706, PD 3554174) and verifies as Pass: +1.15 / +50.0% for 2029 DOE floors. Rated annual electricity draw of 643 kWh/yr equates to roughly $117/yr ($1,168 over 10 years) at 18.16 cents/kWh. Closest certified alternative is Friedrich PROH40 T2 FD400-15 (3.45 UEF).

Uniform Energy Factor
3.45 UEF
Cohort UEF Rank
#563 of 706
First Hour Rating
46 gal
Storage Volume
36 gal
Fuel / Type
Electric / Hybrid/Electric Heat Pump
DOE 2029 Rule Status
Pass: +1.15 / +50.0%
Hybrid heat pump water heater upper shroud with brass relief valve and insulated copper risers
Hybrid heat pump water heater upper shroud with brass relief valve and insulated copper risers
Hybrid/Electric Heat Pump UEF Efficiency Distribution (706 Certified Units)Distribution of certified UEF ratings across 706 units in Hybrid/Electric Heat Pump, marking Rheem ECEPH40 T2 RH400-15 at 3.45 UEF.21130201631342031241542.52 UEF4.50 UEFMedian 3.702029 min 2.30Rheem ECEPH40 T2 RH400-15: 3.45
Hybrid/Electric Heat Pump UEF Efficiency Distribution (706 Certified Units). Highlighted pin shows Rheem ECEPH40 T2 RH400-15 relative to the cohort median.
Efficiency comparison & rule summary

Rheem ECEPH40 T2 RH400-15 records 3.45 UEF efficiency, putting it #563 of 706 among 706 Hybrid/Electric Heat Pump peers.

10 CFR 430.32(d)(2) compliance: Rheem ECEPH40 T2 RH400-15 exceeds 10 CFR 430.32(d)(2) Electric >35 to <=55 gal (2.30 UEF) by +1.15 UEF (+50.0%). At EIA August 2026 national rates (18.16 cents/kWh), 643 kWh/yr for Rheem ECEPH40 T2 RH400-15 runs ~$117/yr vs. ~$438/yr for a 0.92 UEF electric tank.

State electric sensitivity for Rheem ECEPH40 T2 RH400-15: 10-year operating spend spans $941 in Washington (Lowest Hydro Tier) (14.63 cents/kWh) to $3,034 in Hawaii (Highest EIA State) (47.18 cents/kWh).

Competing options beside Rheem ECEPH40 T2 RH400-15 (3.45 UEF) are Friedrich PROH40 T2 FD400-15 (3.45 UEF, at parity) and Richmond 10CE40-HP5U15 (3.45 UEF, at parity).

How Complete Are the Certified Metrics for Rheem ECEPH40 T2 RH400-15?

Standing at #563 of 706 among 706 certified Hybrid/Electric Heat Pump heaters, Rheem ECEPH40 T2 RH400-15 brings measurable deltas in recovery, footprint, and energy efficiency.

Certified model attributes compared against 706 ENERGY STAR Hybrid/Electric Heat Pump peers
Specification AttributeCertified ValueCohort Benchmark / DeltaProvenance
Manufacturer / BrandRheem236 certified listingsENERGY STAR PD 3554174
Model NumberECEPH40 T2 RH400-15Draw pattern: Low-UsageECEPH40 T2 RH400-15
Uniform Energy Factor (UEF)3.45-0.25 UEF vs. 3.70 UEF median10 CFR 430 Test Method
First Hour Rating (FHR)46 gal-26 gal vs. 72 gal median10 CFR 430 Recovery Test
Rated Annual Electricity Use643 kWh/yr-429 kWh/yr vs. 1,072 kWh/yr medianEst. $117/yr @ $0.1816/kWh (EIA US Avg)
Thermal Recovery Efficiency432%+3.0 pts vs. 429.0% medianENERGY STAR Dataset
Physical Envelope (H x Dia)62.3" H x 20.3" DFits standard 72 in. basement/garage clearance; clears 28 in. utility doorway (20.3" D)Doorway & ceiling check
Electrical Circuit Requirements240 V / 12 A maxRequires 240V dedicated branch circuit; check panel capacityNEC / Branch circuit check
Heat Pump Refrigerant & GWPR-134a (GWP:1430)Check regional AIM Act phase-down transitionEPA AIM Act Compliance
Certification Date2026-10-15Certified 2026-10-15Markets: Canada

What Is the Projected Utility Bill for ECEPH40 T2 RH400-15 by State?

At 643 kWh/yr, Rheem ECEPH40 T2 RH400-15 averages about $117/yr across US households—see 10-year payback spreads versus 0.92 UEF resistance tanks.

Estimated Annual Electricity Cost by State Rate (643 kWh/yr)Projected annual electricity spend across five benchmark EIA August 2026 residential electric tiers.United States Average$117.00/yrHawaii$303.00/yrCalifornia$191.00/yrTexas$102.00/yrWashington$94.00/yr
Projected annual electricity spend across five benchmark EIA August 2026 residential electric tiers.
Estimated electricity cost and 10-year spend across benchmark states
Jurisdiction (EIA Aug 2026)Residential RateAnnual Cost10-Yr Operating Spend10-Yr Savings vs. 0.92 UEF
United States Average 18.16 ¢/kWh ($0.1816) $117/yr $1,168 $3,211
Hawaii (Highest EIA State) 47.18 ¢/kWh ($0.4718) $303/yr $3,034 $8,341
California 29.75 ¢/kWh ($0.2975) $191/yr $1,913 $5,260
Texas 15.91 ¢/kWh ($0.1591) $102/yr $1,023 $2,813
Washington (Lowest Hydro Tier) 14.63 ¢/kWh ($0.1463) $94/yr $941 $2,587
Estimated electricity spend (643 kWh/yr)

Condensing Gas Tankless vs. Storage Tank Flow Path & Gas Supply Engineering schematic contrasting 199,000 BTU/h condensing tankless piping (3/4 in. gas supply, Category IV PVC vent, condensate drain) against a 40,000 BTU/h atmospheric tank. Condensing Gas Tankless (0.91–0.96 UEF) Secondary HX Cat IV PVC Vent Cold In Hot Out 3/4"–1" Gas 199K BTU/h Condensate Atmospheric Storage Tank (0.58–0.65 UEF) Type B Flue Anode Rod 40K BTU/h 1/2" Gas Up to 100 ft T&P 150 psi 50–85 gal FHR Reserve | 8–12 yr life
Technical comparison: condensing gas tankless units require 3/4 in.–1 in. IFGC Table 402.4 gas supply and Category IV condensate drainage, while atmospheric tanks run on 1/2 in. lines.

Are Rheem Models Affected by Current CPSC Notices?

Review 4 brand-matched CPSC entries pulled 2026-11-23 for Rheem and confirm your serial tag before scheduling contractor service. See Serial Number Lookup.

4 Brand Recall Notices Found in CPSC Feed — Verify Serial & Model Range
  • Recall #16177 (2016-05-26): Rheem Recalls to Repair Water Heaters Due to Fire and Burn Hazards; Sold Exclusively at Home Depot (CPSC Notice)
  • Recall #07108 (2007-02-21): Tankless Water Heaters Recalled for Repair Due to Carbon Monoxide Poisoning Hazard (CPSC Notice)
  • Recall #05274 (2005-09-16): CPSC, Robertshaw Controls Co. Announce Recall of Gas Control Valves on Water Heaters (CPSC Notice)
  • Recall #80042 (1980-12-04): LP Gas Water Heaters Repaired by White-Rodgers (CPSC Notice)

Which 5 Models Offer Similar Output to ECEPH40 T2 RH400-15?

Ordered by minimal capacity and UEF spread relative to Rheem ECEPH40 T2 RH400-15, these five certified peers give direct replacement benchmarks.

5 closest certified peers matched by equipment class, storage volume, and efficiency rating
Brand & ModelTypeVolFHRUEF (Δ)kWh/yr
Friedrich PROH40 T2 FD400-15 Hybrid/Electric Heat Pump 36 gal 46 gal 3.45 (at parity) 643
Richmond 10CE40-HP5U15 Hybrid/Electric Heat Pump 36 gal 46 gal 3.45 (at parity) 643
Ruud PROUH40 T2 CD400-15 Hybrid/Electric Heat Pump 36 gal 46 gal 3.45 (at parity) 643
A. O. Smith CAHP-40 2** Hybrid/Electric Heat Pump 36 gal 55 gal 3.6 (+0.15) 902
Richmond 10E40-HP5U15 Hybrid/Electric Heat Pump 36 gal 46 gal 3.45 (at parity) 643

What Are the Limitations of Rheem ECEPH40 T2 RH400-15 and Who Should Not Install It?

Before ordering Rheem ECEPH40 T2 RH400-15 (Hybrid/Electric Heat Pump, 3.45 UEF), weigh space clearances, fuel piping, noise (standard dBA), and 2029 rule readiness across three scenarios.

Key Limitations & Exclusions

  • Rheem ECEPH40 T2 RH400-15 needs >=450 cu ft room air volume or ducting so compressor cooling does not stall recovery.
  • Compressor runs near 49 dBA; avoid mounting Rheem ECEPH40 T2 RH400-15 directly beside quiet bedrooms.
  • Requires condensate drain routing and 240V electrical capacity; verify state DOE HEAR status.

Which Option Fits Your Situation?

High Electric Rate States Choosing Rheem ECEPH40 T2 RH400-15 Strong Fit — 3.45 UEF trims electric use ~75% vs 0.92 UEF tanks.
Open Basement or Garage (>=450 cu ft) Strong Fit — Ample ambient air sustains heat-pump-only efficiency.
Small Interior Closet (<300 cu ft) Caution — Add duct kit or compare Friedrich PROH40 T2 FD400-15 footprint.

Practical Specs & Code Questions for Rheem ECEPH40 T2 RH400-15

Direct answers to common technical, regulatory, and sizing questions sourced from primary U.S. government and OEM documentation.

Does Rheem ECEPH40 T2 RH400-15 pass the May 6, 2029 federal DOE efficiency rule?

Rheem ECEPH40 T2 RH400-15 carries a verified 3.45 UEF rating (Pass: +1.15 / +50.0%), ranking #563 of 706 across 706 ENERGY STAR Hybrid/Electric Heat Pump models under 10 CFR 430.32.

What doorway width and ceiling height does Rheem ECEPH40 T2 RH400-15 need?

Rheem ECEPH40 T2 RH400-15 stands 62.3 in. high with a 20.3 in. diameter; fits standard 72 in. basement/garage clearance; clears 28 in. utility doorway (20.3" d). Leave overhead clearance for dielectric nipples, ball shutoff valves, and top air filters.

What gas pipe size or electrical breaker does Rheem ECEPH40 T2 RH400-15 require?

Rheem ECEPH40 T2 RH400-15 uses a 240V branch circuit at 12A max (Requires 240V dedicated branch circuit; check panel capacity). Verify main breaker space before replacing a gas tank with an electric hybrid unit.

How much electricity or energy does Rheem ECEPH40 T2 RH400-15 cost per year to run?

Rated at 643 kWh/yr, Rheem ECEPH40 T2 RH400-15 costs about $117/yr ($1,170 over 10 years) at the August 2026 EIA US average of 18.16 cents/kWh (ranging from $94/yr in Washington hydro tiers up to $303/yr in Hawaii).

Who should NOT install Rheem ECEPH40 T2 RH400-15, and what are its limits?

Rheem ECEPH40 T2 RH400-15 (3.45 UEF) is a poor fit for unvented closets under 450 cu ft because compressor intake chills enclosed rooms and runs at 49 dBA.

How many bathrooms or people can Rheem ECEPH40 T2 RH400-15 serve at peak demand?

Rheem ECEPH40 T2 RH400-15 achieves a 46 gal First Hour Rating (-26 gal vs. 72 gal median). Two back-to-back showers plus a dishwasher run typically call for 55–70 gal FHR.

Are there CPSC safety recalls or serial checks for Rheem ECEPH40 T2 RH400-15?

CPSC SaferProducts records show 4 brand-level recall notices mentioning Rheem as of 2026-11-23, including #16177 (2016-05-26). Enter the rating-plate serial into TapAndPipe's Serial Lookup tool to verify production week.

What 2026 rebates apply to Rheem ECEPH40 T2 RH400-15, and what peer compares closest?

Federal Section 25C expired Dec 31, 2025 (P.L. 119-21); qualifying HPWHs remain eligible for state DOE HEAR rebates up to $1,750 (<=150% AMI). Closest peer in Hybrid/Electric Heat Pump is Friedrich PROH40 T2 FD400-15 (3.45 UEF).

Sources

  1. ENERGY STAR Certified Water Heaters Dataset (Socrata pbpq-swnu) — U.S. EPA & DOE ENERGY STAR, 2026 Live Certified Registry (retrieved 2026-11-23)
  2. 10 CFR 430.32 — Energy and Water Conservation Standards (Water Heaters & Plumbing Fixtures) — U.S. Department of Energy / eCFR, 2026 eCFR (incl. May 6, 2029 Rule) (retrieved 2026-11-23)
  3. CPSC SaferProducts.gov Product Recalls REST API — U.S. Consumer Product Safety Commission, 2026 Live Recalls Feed (retrieved 2026-11-23)
  4. EIA Electric Power Monthly Table 5.6.A — Average Residential Electricity Price by State — U.S. Energy Information Administration (EIA), August 2026 Monthly Release (retrieved 2026-11-23)

Related U.S. Metro Plumbing Benchmarks