Rheem ECEPH50 T2 RH400-15 Water Heater Specifications (3.75 UEF)
The Rheem ECEPH50 T2 RH400-15 (Hybrid/Electric Heat Pump, Electric) achieves a certified 3.75 UEF rating across its 45-gallon nominal tank, 52 gal First Hour Rating, ranking #297 of 706 among 706 ENERGY STAR Hybrid/Electric Heat Pump models (PD 3554195). Under the May 6, 2029 DOE 10 CFR 430.32(d)(2) standard, compliance status is Pass: +1.45 / +63.0%. Rated annual electricity draw of 846 kWh/yr equates to roughly $154/yr ($1,536 over 10 years) at 18.16 cents/kWh. Closest certified alternative is Friedrich PROH50 T2 FD400-15 (3.75 UEF).
- Uniform Energy Factor
- 3.75 UEF
- Cohort UEF Rank
- #297 of 706
- First Hour Rating
- 52 gal
- Storage Volume
- 45 gal
- Fuel / Type
- Electric / Hybrid/Electric Heat Pump
- DOE 2029 Rule Status
- Pass: +1.45 / +63.0%

Rheem ECEPH50 T2 RH400-15 (3.75 UEF) ranks #297 of 706 Hybrid/Electric Heat Pump models — 48-way tie; more efficient than 51.3% of Hybrid/Electric Heat Pump models, +0.05 UEF above the 3.70 UEF median.
Federal 2029 margin for Rheem ECEPH50 T2 RH400-15: +1.45 UEF (+63.0%) vs. 10 CFR 430.32(d)(2) Electric >35 to <=55 gal (2.30 UEF). At EIA August 2026 national rates (18.16 cents/kWh), 846 kWh/yr for Rheem ECEPH50 T2 RH400-15 runs ~$154/yr vs. ~$626/yr for a 0.92 UEF electric tank.
State electric sensitivity for Rheem ECEPH50 T2 RH400-15: 10-year operating spend spans $1,238 in Washington (Lowest Hydro Tier) (14.63 cents/kWh) to $3,991 in Hawaii (Highest EIA State) (47.18 cents/kWh).
Peer comparison: Rheem ECEPH50 T2 RH400-15 (3.75 UEF) compares closely with Friedrich PROH50 T2 FD400-15 (3.75 UEF, at parity) and Richmond 10CE50-HP5U15 (3.75 UEF, at parity).
Which Specs Set Rheem ECEPH50 T2 RH400-15 Apart From Cohort Averages?
Ranked #297 of 706 inside the 706-model Hybrid/Electric Heat Pump cohort, Rheem ECEPH50 T2 RH400-15 is evaluated row by row below against category medians.
| Specification Attribute | Certified Value | Cohort Benchmark / Delta | Provenance |
|---|---|---|---|
| Manufacturer / Brand | Rheem | 236 certified listings | ENERGY STAR PD 3554195 |
| Model Number | ECEPH50 T2 RH400-15 | Draw pattern: Medium-Usage | ECEPH50 T2 RH400-15 |
| Uniform Energy Factor (UEF) | 3.75 | +0.05 UEF vs. 3.70 UEF median | 10 CFR 430 Test Method |
| First Hour Rating (FHR) | 52 gal | -20 gal vs. 72 gal median | 10 CFR 430 Recovery Test |
| Rated Annual Electricity Use | 846 kWh/yr | -226 kWh/yr vs. 1,072 kWh/yr median | Est. $154/yr @ $0.1816/kWh (EIA US Avg) |
| Thermal Recovery Efficiency | 423% | -6.0 pts vs. 429.0% median | ENERGY STAR Dataset |
| Physical Envelope (H x Dia) | 61.8" H x 22.3" D | Fits standard 72 in. basement/garage clearance; clears 28 in. utility doorway (22.3" D) | Doorway & ceiling check |
| Electrical Circuit Requirements | 240 V / 12 A max | Requires 240V dedicated branch circuit; check panel capacity | NEC / Branch circuit check |
| Heat Pump Refrigerant & GWP | R-134a (GWP:1430) | Check regional AIM Act phase-down transition | EPA AIM Act Compliance |
| Certification Date | 2026-10-15 | Certified 2026-10-15 | Markets: Canada |
How Do Regional kWh Prices Impact ECEPH50 T2 RH400-15 Over 10 Years?
Using EIA Table 5.6.A benchmarks, Rheem ECEPH50 T2 RH400-15's 846 kWh/yr draw translates to roughly $154/yr on typical US residential bills.
| Jurisdiction (EIA Aug 2026) | Residential Rate | Annual Cost | 10-Yr Operating Spend | 10-Yr Savings vs. 0.92 UEF |
|---|---|---|---|---|
| United States Average | 18.16 ¢/kWh ($0.1816) | $154/yr | $1,536 | $4,725 |
| Hawaii (Highest EIA State) | 47.18 ¢/kWh ($0.4718) | $399/yr | $3,991 | $12,276 |
| California | 29.75 ¢/kWh ($0.2975) | $252/yr | $2,517 | $7,741 |
| Texas | 15.91 ¢/kWh ($0.1591) | $135/yr | $1,346 | $4,140 |
| Washington (Lowest Hydro Tier) | 14.63 ¢/kWh ($0.1463) | $124/yr | $1,238 | $3,807 |
What Should Rheem Owners Check in CPSC Recall Logs?
The 2026-11-23 CPSC SaferProducts snapshot includes 4 filings tied to Rheem; verify whether your ECEPH50 T2 RH400-15 production run falls inside affected ranges. See Serial Number Lookup.
- Recall #16177 (2016-05-26): Rheem Recalls to Repair Water Heaters Due to Fire and Burn Hazards; Sold Exclusively at Home Depot (CPSC Notice)
- Recall #07108 (2007-02-21): Tankless Water Heaters Recalled for Repair Due to Carbon Monoxide Poisoning Hazard (CPSC Notice)
- Recall #05274 (2005-09-16): CPSC, Robertshaw Controls Co. Announce Recall of Gas Control Valves on Water Heaters (CPSC Notice)
- Recall #80042 (1980-12-04): LP Gas Water Heaters Repaired by White-Rodgers (CPSC Notice)
How Do Five Nearby Hybrid/Electric Heat Pump Models Stack Up?
Five alternative Hybrid/Electric Heat Pump units with nearly identical gallon storage and UEF scores are listed below alongside exact efficiency spreads.
| Brand & Model | Type | Vol | FHR | UEF (Δ) | kWh/yr |
|---|---|---|---|---|---|
| Friedrich PROH50 T2 FD400-15 | Hybrid/Electric Heat Pump | 45 gal | 52 gal | 3.75 (at parity) | 846 |
| Richmond 10CE50-HP5U15 | Hybrid/Electric Heat Pump | 45 gal | 52 gal | 3.75 (at parity) | 846 |
| Ruud PROUH50 T2 CD400-15 | Hybrid/Electric Heat Pump | 45 gal | 52 gal | 3.75 (at parity) | 846 |
| AMERICAN STANDARD WATER HEATERS ASHPWH-50***** | Hybrid/Electric Heat Pump | 45 gal | 68 gal | 3.75 (at parity) | 867 |
| Richmond 10E50-HP515 | Hybrid/Electric Heat Pump | 45 gal | 52 gal | 3.75 (at parity) | 846 |
What Are the Limitations of Rheem ECEPH50 T2 RH400-15 and Who Should Not Install It?
Before ordering Rheem ECEPH50 T2 RH400-15 (Hybrid/Electric Heat Pump, 3.75 UEF), weigh space clearances, fuel piping, noise (standard dBA), and 2029 rule readiness across three scenarios.
Key Limitations & Exclusions
- Rheem ECEPH50 T2 RH400-15 needs >=450 cu ft room air volume or ducting so compressor cooling does not stall recovery.
- Compressor runs near 49 dBA; avoid mounting Rheem ECEPH50 T2 RH400-15 directly beside quiet bedrooms.
- Requires condensate drain routing and 240V electrical capacity; verify state DOE HEAR status.
Which Option Fits Your Situation?
Frequently Asked Technical Questions: Rheem ECEPH50 T2 RH400-15
Direct answers to common technical, regulatory, and sizing questions sourced from primary U.S. government and OEM documentation.
Does Rheem ECEPH50 T2 RH400-15 pass the May 6, 2029 federal DOE efficiency rule?
Rheem ECEPH50 T2 RH400-15 carries a verified 3.75 UEF rating (Pass: +1.45 / +63.0%), ranking #297 of 706 across 706 ENERGY STAR Hybrid/Electric Heat Pump models under 10 CFR 430.32.
What doorway width and ceiling height does Rheem ECEPH50 T2 RH400-15 need?
Rheem ECEPH50 T2 RH400-15 stands 61.8 in. high with a 22.3 in. diameter; fits standard 72 in. basement/garage clearance; clears 28 in. utility doorway (22.3" d). Leave overhead clearance for dielectric nipples, ball shutoff valves, and top air filters.
What gas pipe size or electrical breaker does Rheem ECEPH50 T2 RH400-15 require?
Rheem ECEPH50 T2 RH400-15 uses a 240V branch circuit at 12A max (Requires 240V dedicated branch circuit; check panel capacity). Verify main breaker space before replacing a gas tank with an electric hybrid unit.
How much electricity or energy does Rheem ECEPH50 T2 RH400-15 cost per year to run?
Rated at 846 kWh/yr, Rheem ECEPH50 T2 RH400-15 costs about $154/yr ($1,540 over 10 years) at the August 2026 EIA US average of 18.16 cents/kWh (ranging from $124/yr in Washington hydro tiers up to $399/yr in Hawaii).
Who should NOT install Rheem ECEPH50 T2 RH400-15, and what are its limits?
Rheem ECEPH50 T2 RH400-15 (3.75 UEF) is a poor fit for unvented closets under 450 cu ft because compressor intake chills enclosed rooms and runs at 49 dBA.
How many bathrooms or people can Rheem ECEPH50 T2 RH400-15 serve at peak demand?
Rheem ECEPH50 T2 RH400-15 achieves a 52 gal First Hour Rating (-20 gal vs. 72 gal median). Two back-to-back showers plus a dishwasher run typically call for 55–70 gal FHR.
Are there CPSC safety recalls or serial checks for Rheem ECEPH50 T2 RH400-15?
CPSC SaferProducts records show 4 brand-level recall notices mentioning Rheem as of 2026-11-23, including #16177 (2016-05-26). Enter the rating-plate serial into TapAndPipe's Serial Lookup tool to verify production week.
What 2026 rebates apply to Rheem ECEPH50 T2 RH400-15, and what peer compares closest?
Federal Section 25C expired Dec 31, 2025 (P.L. 119-21); qualifying HPWHs remain eligible for state DOE HEAR rebates up to $1,750 (<=150% AMI). Closest peer in Hybrid/Electric Heat Pump is Friedrich PROH50 T2 FD400-15 (3.75 UEF).
Sources
- ENERGY STAR Certified Water Heaters Dataset (Socrata pbpq-swnu) — U.S. EPA & DOE ENERGY STAR, 2026 Live Certified Registry (retrieved 2026-11-23)
- 10 CFR 430.32 — Energy and Water Conservation Standards (Water Heaters & Plumbing Fixtures) — U.S. Department of Energy / eCFR, 2026 eCFR (incl. May 6, 2029 Rule) (retrieved 2026-11-23)
- CPSC SaferProducts.gov Product Recalls REST API — U.S. Consumer Product Safety Commission, 2026 Live Recalls Feed (retrieved 2026-11-23)
- EIA Electric Power Monthly Table 5.6.A — Average Residential Electricity Price by State — U.S. Energy Information Administration (EIA), August 2026 Monthly Release (retrieved 2026-11-23)