Skip to main content
ENERGY STAR water heater model · PD 3554242

Rheem ECEPH80 T2 RH400-15 Water Heater Specifications (3.7 UEF)

Engineered as a Electric Hybrid/Electric Heat Pump unit, Rheem ECEPH80 T2 RH400-15 achieves a certified 3.7 UEF rating across its 72-gallon nominal tank, 67 gal First Hour Rating and ranks #347 of 706 in its 706-model cohort (PD 3554242), recording Pass: +1.20 / +48.0% under 2029 DOE rules. Rated annual electricity draw of 871 kWh/yr equates to roughly $158/yr ($1,582 over 10 years) at 18.16 cents/kWh. Closest certified alternative is Friedrich PROH80 T2 FD400-15 (3.7 UEF).

Uniform Energy Factor
3.7 UEF
Cohort UEF Rank
#347 of 706
First Hour Rating
67 gal
Storage Volume
72 gal
Fuel / Type
Electric / Hybrid/Electric Heat Pump
DOE 2029 Rule Status
Pass: +1.20 / +48.0%
Hybrid heat pump water heater upper shroud with brass relief valve and insulated copper risers
Hybrid heat pump water heater upper shroud with brass relief valve and insulated copper risers
Hybrid/Electric Heat Pump UEF Efficiency Distribution (706 Certified Units)Distribution of certified UEF ratings across 706 units in Hybrid/Electric Heat Pump, marking Rheem ECEPH80 T2 RH400-15 at 3.7 UEF.21130201631342031241542.52 UEF4.50 UEFMedian 3.702029 min 2.50Rheem ECEPH80 T2 RH400-15: 3.70
Hybrid/Electric Heat Pump UEF Efficiency Distribution (706 Certified Units). Highlighted pin shows Rheem ECEPH80 T2 RH400-15 relative to the cohort median.
Efficiency comparison & rule summary

Within the 706-unit Hybrid/Electric Heat Pump cohort, Rheem ECEPH80 T2 RH400-15 logs 3.7 UEF and ranks #347 of 706.

Against 10 CFR 430.32(d)(2) Electric >55 to <=120 gal (2.50 UEF), Rheem ECEPH80 T2 RH400-15 holds a +1.20 UEF (+48.0%) compliance cushion. At EIA August 2026 national rates (18.16 cents/kWh), 871 kWh/yr for Rheem ECEPH80 T2 RH400-15 runs ~$158/yr vs. ~$636/yr for a 0.92 UEF electric tank.

State electric sensitivity for Rheem ECEPH80 T2 RH400-15: 10-year operating spend spans $1,274 in Washington (Lowest Hydro Tier) (14.63 cents/kWh) to $4,109 in Hawaii (Highest EIA State) (47.18 cents/kWh).

Cross-shopping Rheem ECEPH80 T2 RH400-15 (3.7 UEF)? Check Friedrich PROH80 T2 FD400-15 (3.7 UEF, at parity) and Richmond 10CE80-HP5U15 (3.7 UEF, at parity).

Where Does Rheem ECEPH80 T2 RH400-15 Rank Against Peer Hybrid/Electric Heat Pump Units?

Audited against 706 ENERGY STAR Hybrid/Electric Heat Pump listings, Rheem ECEPH80 T2 RH400-15 holds #347 of 706; inspect footprint, circuit load, and efficiency deltas here.

Certified model attributes compared against 706 ENERGY STAR Hybrid/Electric Heat Pump peers
Specification AttributeCertified ValueCohort Benchmark / DeltaProvenance
Manufacturer / BrandRheem236 certified listingsENERGY STAR PD 3554242
Model NumberECEPH80 T2 RH400-15Draw pattern: Medium-UsageECEPH80 T2 RH400-15
Uniform Energy Factor (UEF)3.7At 3.70 UEF median10 CFR 430 Test Method
First Hour Rating (FHR)67 gal-5 gal vs. 72 gal median10 CFR 430 Recovery Test
Rated Annual Electricity Use871 kWh/yr-201 kWh/yr vs. 1,072 kWh/yr medianEst. $158/yr @ $0.1816/kWh (EIA US Avg)
Thermal Recovery Efficiency445%+16.0 pts vs. 429.0% medianENERGY STAR Dataset
Physical Envelope (H x Dia)74.2" H x 24.3" DNeeds >72 in. overhead clearance; clears 28 in. utility doorway (24.3" D)Doorway & ceiling check
Electrical Circuit Requirements240 V / 12 A maxRequires 240V dedicated branch circuit; check panel capacityNEC / Branch circuit check
Heat Pump Refrigerant & GWPR-134a (GWP:1430)Check regional AIM Act phase-down transitionEPA AIM Act Compliance
Certification Date2026-10-15Certified 2026-10-15Markets: Canada

How Much Electricity Does ECEPH80 T2 RH400-15 Use in Different States?

Estimated at $158/yr nationally (871 kWh/yr), 10-year utility spending for Rheem ECEPH80 T2 RH400-15 shifts sharply between low-rate hydro and coastal grids.

Estimated Annual Electricity Cost by State Rate (871 kWh/yr)Projected annual electricity spend across five benchmark EIA August 2026 residential electric tiers.United States Average$158.00/yrHawaii$411.00/yrCalifornia$259.00/yrTexas$139.00/yrWashington$127.00/yr
Projected annual electricity spend across five benchmark EIA August 2026 residential electric tiers.
Estimated electricity cost and 10-year spend across benchmark states
Jurisdiction (EIA Aug 2026)Residential RateAnnual Cost10-Yr Operating Spend10-Yr Savings vs. 0.92 UEF
United States Average 18.16 ¢/kWh ($0.1816) $158/yr $1,582 $4,780
Hawaii (Highest EIA State) 47.18 ¢/kWh ($0.4718) $411/yr $4,109 $12,418
California 29.75 ¢/kWh ($0.2975) $259/yr $2,591 $7,830
Texas 15.91 ¢/kWh ($0.1591) $139/yr $1,386 $4,188
Washington (Lowest Hydro Tier) 14.63 ¢/kWh ($0.1463) $127/yr $1,274 $3,851
Estimated electricity spend (871 kWh/yr)

Condensing Gas Tankless vs. Storage Tank Flow Path & Gas Supply Engineering schematic contrasting 199,000 BTU/h condensing tankless piping (3/4 in. gas supply, Category IV PVC vent, condensate drain) against a 40,000 BTU/h atmospheric tank. Condensing Gas Tankless (0.91–0.96 UEF) Secondary HX Cat IV PVC Vent Cold In Hot Out 3/4"–1" Gas 199K BTU/h Condensate Atmospheric Storage Tank (0.58–0.65 UEF) Type B Flue Anode Rod 40K BTU/h 1/2" Gas Up to 100 ft T&P 150 psi 50–85 gal FHR Reserve | 8–12 yr life
Technical comparison: condensing gas tankless units require 3/4 in.–1 in. IFGC Table 402.4 gas supply and Category IV condensate drainage, while atmospheric tanks run on 1/2 in. lines.

Does CPSC Flag Any Safety Notices on Rheem Units?

Checking 2026-11-23 SaferProducts data shows 4 notices mentioning Rheem; always cross-reference affected serial prefixes before ordering components. See Serial Number Lookup.

4 Brand Recall Notices Found in CPSC Feed — Verify Serial & Model Range
  • Recall #16177 (2016-05-26): Rheem Recalls to Repair Water Heaters Due to Fire and Burn Hazards; Sold Exclusively at Home Depot (CPSC Notice)
  • Recall #07108 (2007-02-21): Tankless Water Heaters Recalled for Repair Due to Carbon Monoxide Poisoning Hazard (CPSC Notice)
  • Recall #05274 (2005-09-16): CPSC, Robertshaw Controls Co. Announce Recall of Gas Control Valves on Water Heaters (CPSC Notice)
  • Recall #80042 (1980-12-04): LP Gas Water Heaters Repaired by White-Rodgers (CPSC Notice)

Which Competing Hybrid/Electric Heat Pump Models Compare Closest to ECEPH80 T2 RH400-15?

Compare five nearby ENERGY STAR Hybrid/Electric Heat Pump options matched closely to Rheem ECEPH80 T2 RH400-15's gallon capacity and 3.7 UEF efficiency.

5 closest certified peers matched by equipment class, storage volume, and efficiency rating
Brand & ModelTypeVolFHRUEF (Δ)kWh/yr
Friedrich PROH80 T2 FD400-15 Hybrid/Electric Heat Pump 72 gal 67 gal 3.7 (at parity) 871
Richmond 10CE80-HP5U15 Hybrid/Electric Heat Pump 72 gal 67 gal 3.7 (at parity) 871
Ruud PROUH80 T2 CD400-15 Hybrid/Electric Heat Pump 72 gal 67 gal 3.7 (at parity) 871
LG APHWC801D Hybrid/Electric Heat Pump 72 gal 94 gal 3.9 (+0.20) 1,272
Richmond 10E80-HP515 Hybrid/Electric Heat Pump 72 gal 67 gal 3.7 (at parity) 871

Who Is Rheem ECEPH80 T2 RH400-15 Best For — and When Should You Pick Friedrich PROH80 T2 FD400-15?

Evaluate whether Rheem ECEPH80 T2 RH400-15's Hybrid/Electric Heat Pump architecture matches your existing mechanical room and local utility tariffs before purchasing.

Key Limitations & Exclusions

  • Rheem ECEPH80 T2 RH400-15 needs >=450 cu ft room air volume or ducting so compressor cooling does not stall recovery.
  • Compressor runs near 49 dBA; avoid mounting Rheem ECEPH80 T2 RH400-15 directly beside quiet bedrooms.
  • Requires condensate drain routing and 240V electrical capacity; verify state DOE HEAR status.

Which Option Fits Your Situation?

High Electric Rate States Choosing Rheem ECEPH80 T2 RH400-15 Strong Fit — 3.7 UEF trims electric use ~75% vs 0.92 UEF tanks.
Open Basement or Garage (>=450 cu ft) Strong Fit — Ample ambient air sustains heat-pump-only efficiency.
Small Interior Closet (<300 cu ft) Caution — Add duct kit or compare Friedrich PROH80 T2 FD400-15 footprint.

Common Homeowner Questions for Rheem ECEPH80 T2 RH400-15

Direct answers to common technical, regulatory, and sizing questions sourced from primary U.S. government and OEM documentation.

How does Rheem ECEPH80 T2 RH400-15 (3.7 UEF) compare to 2029 federal DOE floors?

Evaluated against May 6, 2029 10 CFR 430.32 thresholds, Rheem ECEPH80 T2 RH400-15 records 3.7 UEF (Pass: +1.20 / +48.0%), placing #347 of 706 out of 706 certified Hybrid/Electric Heat Pump configurations.

Does Rheem ECEPH80 T2 RH400-15 fit inside a tight hallway closet or low-headroom utility room?

Rheem ECEPH80 T2 RH400-15 requires room for its 74.2 in. vertical shell and 24.3 in. diameter (needs >72 in. overhead clearance; clears 28 in. utility doorway (24.3" d)), plus service access for annual sediment draining.

What power supply or fuel line specs govern Rheem ECEPH80 T2 RH400-15?

For Rheem ECEPH80 T2 RH400-15, plan a 240V circuit at 12A max (Requires 240V dedicated branch circuit; check panel capacity) and keep a dedicated shutoff disconnect within sight of the unit.

What annual utility bill should homeowners budget for Rheem ECEPH80 T2 RH400-15?

Using 871 kWh/yr, Rheem ECEPH80 T2 RH400-15 generates an estimated $158/yr electric bill at 18.16 cents/kWh (ranging from $127/yr in Washington hydro tiers up to $411/yr in Hawaii)—use the custom rate slider above for your utility tariff.

What are the main drawbacks of Rheem ECEPH80 T2 RH400-15 (3.7 UEF)?

Rheem ECEPH80 T2 RH400-15 requires >=450 cu ft air space, 240V electrical supply, and drain access; tight interior alcoves favor ducted adapters or Friedrich PROH80 T2 FD400-15.

What hot-water delivery rating governs Rheem ECEPH80 T2 RH400-15?

Rated for 67 gal FHR (-5 gal vs. 72 gal median), Rheem ECEPH80 T2 RH400-15 prevents mid-morning cold drops when matched to 55–70+ gal multi-bath household loads.

Where do homeowners screen Rheem ECEPH80 T2 RH400-15 for recalls and tank age?

CPSC SaferProducts records show 4 brand-level recall notices mentioning Rheem as of 2026-11-23, including #16177 (2016-05-26). Enter the rating-plate serial into TapAndPipe's Serial Lookup tool to verify production week.

What alternative models sit closest to Rheem ECEPH80 T2 RH400-15 in the Hybrid/Electric Heat Pump class?

Closest peer in Hybrid/Electric Heat Pump is Friedrich PROH80 T2 FD400-15 (3.7 UEF). For 2026 incentives, look to state DOE HEAR grants ($1,750 max on qualifying HPWHs) and local municipal utility credits.

Sources

  1. ENERGY STAR Certified Water Heaters Dataset (Socrata pbpq-swnu) — U.S. EPA & DOE ENERGY STAR, 2026 Live Certified Registry (retrieved 2026-11-23)
  2. 10 CFR 430.32 — Energy and Water Conservation Standards (Water Heaters & Plumbing Fixtures) — U.S. Department of Energy / eCFR, 2026 eCFR (incl. May 6, 2029 Rule) (retrieved 2026-11-23)
  3. CPSC SaferProducts.gov Product Recalls REST API — U.S. Consumer Product Safety Commission, 2026 Live Recalls Feed (retrieved 2026-11-23)
  4. EIA Electric Power Monthly Table 5.6.A — Average Residential Electricity Price by State — U.S. Energy Information Administration (EIA), August 2026 Monthly Release (retrieved 2026-11-23)

Related U.S. Metro Plumbing Benchmarks