Rheem PRO H65 T2 RH310UM Water Heater Specifications (3.5 UEF)
Engineered as a Electric Hybrid/Electric Heat Pump unit, Rheem PRO H65 T2 RH310UM achieves a certified 3.5 UEF rating across its 59-gallon nominal tank, 75 gal First Hour Rating and ranks #481 of 706 in its 706-model cohort (PD 2408597), recording Pass: +1.00 / +40.0% under 2029 DOE rules. Rated annual electricity draw of 900 kWh/yr equates to roughly $163/yr ($1,634 over 10 years) at 18.16 cents/kWh. Closest certified alternative is Friedrich PROH65 T2 FD310BM (3.5 UEF).
- Uniform Energy Factor
- 3.5 UEF
- Cohort UEF Rank
- #481 of 706
- First Hour Rating
- 75 gal
- Storage Volume
- 59 gal
- Fuel / Type
- Electric / Hybrid/Electric Heat Pump
- DOE 2029 Rule Status
- Pass: +1.00 / +40.0%

Within the 706-unit Hybrid/Electric Heat Pump cohort, Rheem PRO H65 T2 RH310UM logs 3.5 UEF and ranks #481 of 706.
Against 10 CFR 430.32(d)(2) Electric >55 to <=120 gal (2.50 UEF), Rheem PRO H65 T2 RH310UM holds a +1.00 UEF (+40.0%) compliance cushion. At EIA August 2026 national rates (18.16 cents/kWh), 900 kWh/yr for Rheem PRO H65 T2 RH310UM runs ~$163/yr vs. ~$622/yr for a 0.92 UEF electric tank.
State electric sensitivity for Rheem PRO H65 T2 RH310UM: 10-year operating spend spans $1,317 in Washington (Lowest Hydro Tier) (14.63 cents/kWh) to $4,246 in Hawaii (Highest EIA State) (47.18 cents/kWh).
Cross-shopping Rheem PRO H65 T2 RH310UM (3.5 UEF)? Check Friedrich PROH65 T2 FD310BM (3.5 UEF, at parity) and Ruud PRO H65 T2 RU310BM (3.5 UEF, at parity).
Where Does Rheem PRO H65 T2 RH310UM Rank Against Peer Hybrid/Electric Heat Pump Units?
Audited against 706 ENERGY STAR Hybrid/Electric Heat Pump listings, Rheem PRO H65 T2 RH310UM holds #481 of 706; inspect footprint, circuit load, and efficiency deltas here.
| Specification Attribute | Certified Value | Cohort Benchmark / Delta | Provenance |
|---|---|---|---|
| Manufacturer / Brand | Rheem | 236 certified listings | ENERGY STAR PD 2408597 |
| Model Number | PRO H65 T2 RH310UM | Draw pattern: High-Usage | PRO H65 T2 RH310UM |
| Uniform Energy Factor (UEF) | 3.5 | -0.20 UEF vs. 3.70 UEF median | 10 CFR 430 Test Method |
| First Hour Rating (FHR) | 75 gal | +3 gal vs. 72 gal median | 10 CFR 430 Recovery Test |
| Rated Annual Electricity Use | 900 kWh/yr | -172 kWh/yr vs. 1,072 kWh/yr median | Est. $163/yr @ $0.1816/kWh (EIA US Avg) |
| Thermal Recovery Efficiency | 409% | -20.0 pts vs. 429.0% median | ENERGY STAR Dataset |
| Physical Envelope (H x Dia) | 64.2" H x 24.3" D | Verify 72 in. vertical headroom; clears 28 in. utility doorway (24.3" D) | Doorway & ceiling check |
| Electrical Circuit Requirements | 240 V / 21 A max | Requires 240V dedicated branch circuit; check panel capacity | NEC / Branch circuit check |
| Heat Pump Refrigerant & GWP | R-134a (GWP:1430) | Check regional AIM Act phase-down transition | EPA AIM Act Compliance |
| Certification Date | 2026-10-15 | Certified 2026-10-15 | Markets: United States |
How Much Electricity Does PRO H65 T2 RH310UM Use in Different States?
Estimated at $163/yr nationally (900 kWh/yr), 10-year utility spending for Rheem PRO H65 T2 RH310UM shifts sharply between low-rate hydro and coastal grids.
| Jurisdiction (EIA Aug 2026) | Residential Rate | Annual Cost | 10-Yr Operating Spend | 10-Yr Savings vs. 0.92 UEF |
|---|---|---|---|---|
| United States Average | 18.16 ¢/kWh ($0.1816) | $163/yr | $1,634 | $4,584 |
| Hawaii (Highest EIA State) | 47.18 ¢/kWh ($0.4718) | $425/yr | $4,246 | $11,908 |
| California | 29.75 ¢/kWh ($0.2975) | $268/yr | $2,678 | $7,509 |
| Texas | 15.91 ¢/kWh ($0.1591) | $143/yr | $1,432 | $4,016 |
| Washington (Lowest Hydro Tier) | 14.63 ¢/kWh ($0.1463) | $132/yr | $1,317 | $3,693 |
Does CPSC Flag Any Safety Notices on Rheem Units?
Checking 2026-11-23 SaferProducts data shows 4 notices mentioning Rheem; always cross-reference affected serial prefixes before ordering components. See Serial Number Lookup.
- Recall #16177 (2016-05-26): Rheem Recalls to Repair Water Heaters Due to Fire and Burn Hazards; Sold Exclusively at Home Depot (CPSC Notice)
- Recall #07108 (2007-02-21): Tankless Water Heaters Recalled for Repair Due to Carbon Monoxide Poisoning Hazard (CPSC Notice)
- Recall #05274 (2005-09-16): CPSC, Robertshaw Controls Co. Announce Recall of Gas Control Valves on Water Heaters (CPSC Notice)
- Recall #80042 (1980-12-04): LP Gas Water Heaters Repaired by White-Rodgers (CPSC Notice)
Which Competing Hybrid/Electric Heat Pump Models Compare Closest to PRO H65 T2 RH310UM?
Compare five nearby ENERGY STAR Hybrid/Electric Heat Pump options matched closely to Rheem PRO H65 T2 RH310UM's gallon capacity and 3.5 UEF efficiency.
| Brand & Model | Type | Vol | FHR | UEF (Δ) | kWh/yr |
|---|---|---|---|---|---|
| Friedrich PROH65 T2 FD310BM | Hybrid/Electric Heat Pump | 59 gal | 75 gal | 3.5 (at parity) | 900 |
| Ruud PRO H65 T2 RU310BM | Hybrid/Electric Heat Pump | 59 gal | 75 gal | 3.5 (at parity) | 900 |
| Richmond 10CE65-HP5U15 | Hybrid/Electric Heat Pump | 59 gal | 54 gal | 3.55 (+0.05) | 887 |
| A. O. Smith HPACO-45 1**+AXST-66 1** | Hybrid/Electric Heat Pump | 60 gal | 82 gal | 3.7 (+0.20) | 1,341 |
| Friedrich PROH65 T2 FD310UM | Hybrid/Electric Heat Pump | 59 gal | 75 gal | 3.5 (at parity) | 900 |
What Are the Limitations of Rheem PRO H65 T2 RH310UM and Who Should Not Install It?
Before ordering Rheem PRO H65 T2 RH310UM (Hybrid/Electric Heat Pump, 3.5 UEF), weigh space clearances, fuel piping, noise (standard dBA), and 2029 rule readiness across three scenarios.
Key Limitations & Exclusions
- Rheem PRO H65 T2 RH310UM needs >=450 cu ft room air volume or ducting so compressor cooling does not stall recovery.
- Compressor runs near 49 dBA; avoid mounting Rheem PRO H65 T2 RH310UM directly beside quiet bedrooms.
- Requires condensate drain routing and 240V electrical capacity; verify state DOE HEAR status.
Which Option Fits Your Situation?
Common Homeowner Questions for Rheem PRO H65 T2 RH310UM
Direct answers to common technical, regulatory, and sizing questions sourced from primary U.S. government and OEM documentation.
Does Rheem PRO H65 T2 RH310UM pass the May 6, 2029 federal DOE efficiency rule?
Rheem PRO H65 T2 RH310UM carries a verified 3.5 UEF rating (Pass: +1.00 / +40.0%), ranking #481 of 706 across 706 ENERGY STAR Hybrid/Electric Heat Pump models under 10 CFR 430.32.
What doorway width and ceiling height does Rheem PRO H65 T2 RH310UM need?
Rheem PRO H65 T2 RH310UM stands 64.2 in. high with a 24.3 in. diameter; verify 72 in. vertical headroom; clears 28 in. utility doorway (24.3" d). Leave overhead clearance for dielectric nipples, ball shutoff valves, and top air filters.
What gas pipe size or electrical breaker does Rheem PRO H65 T2 RH310UM require?
Rheem PRO H65 T2 RH310UM uses a 240V branch circuit at 21A max (Requires 240V dedicated branch circuit; check panel capacity). Verify main breaker space before replacing a gas tank with an electric hybrid unit.
How much electricity or energy does Rheem PRO H65 T2 RH310UM cost per year to run?
Rated at 900 kWh/yr, Rheem PRO H65 T2 RH310UM costs about $163/yr ($1,630 over 10 years) at the August 2026 EIA US average of 18.16 cents/kWh (ranging from $132/yr in Washington hydro tiers up to $425/yr in Hawaii).
Who should NOT install Rheem PRO H65 T2 RH310UM, and what are its limits?
Rheem PRO H65 T2 RH310UM (3.5 UEF) is a poor fit for unvented closets under 450 cu ft because compressor intake chills enclosed rooms and runs at 49 dBA.
How many bathrooms or people can Rheem PRO H65 T2 RH310UM serve at peak demand?
Rheem PRO H65 T2 RH310UM achieves a 75 gal First Hour Rating (+3 gal vs. 72 gal median). Two back-to-back showers plus a dishwasher run typically call for 55–70 gal FHR.
Are there CPSC safety recalls or serial checks for Rheem PRO H65 T2 RH310UM?
CPSC SaferProducts records show 4 brand-level recall notices mentioning Rheem as of 2026-11-23, including #16177 (2016-05-26). Enter the rating-plate serial into TapAndPipe's Serial Lookup tool to verify production week.
What 2026 rebates apply to Rheem PRO H65 T2 RH310UM, and what peer compares closest?
Federal Section 25C expired Dec 31, 2025 (P.L. 119-21); qualifying HPWHs remain eligible for state DOE HEAR rebates up to $1,750 (<=150% AMI). Closest peer in Hybrid/Electric Heat Pump is Friedrich PROH65 T2 FD310BM (3.5 UEF).
Sources
- ENERGY STAR Certified Water Heaters Dataset (Socrata pbpq-swnu) — U.S. EPA & DOE ENERGY STAR, 2026 Live Certified Registry (retrieved 2026-11-23)
- 10 CFR 430.32 — Energy and Water Conservation Standards (Water Heaters & Plumbing Fixtures) — U.S. Department of Energy / eCFR, 2026 eCFR (incl. May 6, 2029 Rule) (retrieved 2026-11-23)
- CPSC SaferProducts.gov Product Recalls REST API — U.S. Consumer Product Safety Commission, 2026 Live Recalls Feed (retrieved 2026-11-23)
- EIA Electric Power Monthly Table 5.6.A — Average Residential Electricity Price by State — U.S. Energy Information Administration (EIA), August 2026 Monthly Release (retrieved 2026-11-23)