Rheem PROPH80 T2 RH400-SO Water Heater Specifications (4.07 UEF)
In the 706-unit Hybrid/Electric Heat Pump class, Rheem PROPH80 T2 RH400-SO (Electric) achieves a certified 4.07 UEF rating across its 72-gallon nominal tank, 87 gal First Hour Rating (rank #26 of 706, PD 3554244) and verifies as Pass: +1.57 / +62.8% for 2029 DOE floors. Rated annual electricity draw of 1,213 kWh/yr equates to roughly $220/yr ($2,203 over 10 years) at 18.16 cents/kWh. Closest certified alternative is Friedrich PROH80 T2 FD400-30 (4.07 UEF).
- Uniform Energy Factor
- 4.07 UEF
- Cohort UEF Rank
- #26 of 706 (top 8.5%)
- First Hour Rating
- 87 gal
- Storage Volume
- 72 gal
- Fuel / Type
- Electric / Hybrid/Electric Heat Pump
- DOE 2029 Rule Status
- Pass: +1.57 / +62.8%

Rheem PROPH80 T2 RH400-SO records 4.07 UEF efficiency, putting it #26 of 706 among 706 Hybrid/Electric Heat Pump peers.
10 CFR 430.32(d)(2) compliance: Rheem PROPH80 T2 RH400-SO exceeds 10 CFR 430.32(d)(2) Electric >55 to <=120 gal (2.50 UEF) by +1.57 UEF (+62.8%). At EIA August 2026 national rates (18.16 cents/kWh), 1,213 kWh/yr for Rheem PROPH80 T2 RH400-SO runs ~$220/yr vs. ~$974/yr for a 0.92 UEF electric tank.
State electric sensitivity for Rheem PROPH80 T2 RH400-SO: 10-year operating spend spans $1,775 in Washington (Lowest Hydro Tier) (14.63 cents/kWh) to $5,723 in Hawaii (Highest EIA State) (47.18 cents/kWh).
Competing options beside Rheem PROPH80 T2 RH400-SO (4.07 UEF) are Friedrich PROH80 T2 FD400-30 (4.07 UEF, at parity) and Richmond 10CE80-HP5S30 (4.07 UEF, at parity).
How Complete Are the Certified Metrics for Rheem PROPH80 T2 RH400-SO?
Standing at #26 of 706 (top 8.5%) among 706 certified Hybrid/Electric Heat Pump heaters, Rheem PROPH80 T2 RH400-SO brings measurable deltas in recovery, footprint, and energy efficiency.
| Specification Attribute | Certified Value | Cohort Benchmark / Delta | Provenance |
|---|---|---|---|
| Manufacturer / Brand | Rheem | 236 certified listings | ENERGY STAR PD 3554244 |
| Model Number | PROPH80 T2 RH400-SO | Draw pattern: High-Usage | PROPH80 T2 RH400-SO |
| Uniform Energy Factor (UEF) | 4.07 | +0.37 UEF vs. 3.70 UEF median | 10 CFR 430 Test Method |
| First Hour Rating (FHR) | 87 gal | +15 gal vs. 72 gal median | 10 CFR 430 Recovery Test |
| Rated Annual Electricity Use | 1,213 kWh/yr | +141 kWh/yr vs. 1,072 kWh/yr median | Est. $220/yr @ $0.1816/kWh (EIA US Avg) |
| Thermal Recovery Efficiency | 447% | +18.0 pts vs. 429.0% median | ENERGY STAR Dataset |
| Physical Envelope (H x Dia) | 74.2" H x 24.3" D | Needs >72 in. overhead clearance; clears 28 in. utility doorway (24.3" D) | Doorway & ceiling check |
| Electrical Circuit Requirements | 240 V / 21 A max | Requires 240V dedicated branch circuit; check panel capacity | NEC / Branch circuit check |
| Heat Pump Refrigerant & GWP | R-134a (GWP:1430) | Check regional AIM Act phase-down transition | EPA AIM Act Compliance |
| Certification Date | 2026-10-15 | Certified 2026-10-15 | Markets: United States |
What Is the Projected Utility Bill for PROPH80 T2 RH400-SO by State?
At 1,213 kWh/yr, Rheem PROPH80 T2 RH400-SO averages about $220/yr across US households—see 10-year payback spreads versus 0.92 UEF resistance tanks.
| Jurisdiction (EIA Aug 2026) | Residential Rate | Annual Cost | 10-Yr Operating Spend | 10-Yr Savings vs. 0.92 UEF |
|---|---|---|---|---|
| United States Average | 18.16 ¢/kWh ($0.1816) | $220/yr | $2,203 | $7,542 |
| Hawaii (Highest EIA State) | 47.18 ¢/kWh ($0.4718) | $572/yr | $5,723 | $19,594 |
| California | 29.75 ¢/kWh ($0.2975) | $361/yr | $3,609 | $12,355 |
| Texas | 15.91 ¢/kWh ($0.1591) | $193/yr | $1,930 | $6,607 |
| Washington (Lowest Hydro Tier) | 14.63 ¢/kWh ($0.1463) | $177/yr | $1,775 | $6,076 |
Are Rheem Models Affected by Current CPSC Notices?
Review 4 brand-matched CPSC entries pulled 2026-11-23 for Rheem and confirm your serial tag before scheduling contractor service. See Serial Number Lookup.
- Recall #16177 (2016-05-26): Rheem Recalls to Repair Water Heaters Due to Fire and Burn Hazards; Sold Exclusively at Home Depot (CPSC Notice)
- Recall #07108 (2007-02-21): Tankless Water Heaters Recalled for Repair Due to Carbon Monoxide Poisoning Hazard (CPSC Notice)
- Recall #05274 (2005-09-16): CPSC, Robertshaw Controls Co. Announce Recall of Gas Control Valves on Water Heaters (CPSC Notice)
- Recall #80042 (1980-12-04): LP Gas Water Heaters Repaired by White-Rodgers (CPSC Notice)
Which 5 Models Offer Similar Output to PROPH80 T2 RH400-SO?
Ordered by minimal capacity and UEF spread relative to Rheem PROPH80 T2 RH400-SO, these five certified peers give direct replacement benchmarks.
| Brand & Model | Type | Vol | FHR | UEF (Δ) | kWh/yr |
|---|---|---|---|---|---|
| Friedrich PROH80 T2 FD400-30 | Hybrid/Electric Heat Pump | 72 gal | 87 gal | 4.07 (at parity) | 1,213 |
| Richmond 10CE80-HP5S30 | Hybrid/Electric Heat Pump | 72 gal | 87 gal | 4.07 (at parity) | 1,213 |
| Ruud CPROPH80 T2 CD375-30 | Hybrid/Electric Heat Pump | 72 gal | 87 gal | 4.07 (at parity) | 1,213 |
| LG APHWC802D | Hybrid/Electric Heat Pump | 72 gal | 91 gal | 4.1 (+0.03) | 1,210 |
| Friedrich PROH80 T2 FD400-SO | Hybrid/Electric Heat Pump | 72 gal | 87 gal | 4.07 (at parity) | 1,213 |
Which Home Setups Are NOT a Fit for Rheem PROPH80 T2 RH400-SO?
Comparing Rheem PROPH80 T2 RH400-SO against Friedrich PROH80 T2 FD400-30 requires checking closet airflow, IFGC gas or 240V electrical sizing, and May 6, 2029 compliance.
Key Limitations & Exclusions
- Rheem PROPH80 T2 RH400-SO needs >=450 cu ft room air volume or ducting so compressor cooling does not stall recovery.
- Compressor runs near 49 dBA; avoid mounting Rheem PROPH80 T2 RH400-SO directly beside quiet bedrooms.
- Requires condensate drain routing and 240V electrical capacity; verify state DOE HEAR status.
Which Option Fits Your Situation?
Practical Specs & Code Questions for Rheem PROPH80 T2 RH400-SO
Direct answers to common technical, regulatory, and sizing questions sourced from primary U.S. government and OEM documentation.
How does Rheem PROPH80 T2 RH400-SO score under 10 CFR 430.32 May 2029 water heater minimums?
Federal 10 CFR 430.32 rules set the May 6, 2029 manufacturing baseline; Rheem PROPH80 T2 RH400-SO logs 4.07 UEF (Pass: +1.57 / +62.8%) within the 706-unit Hybrid/Electric Heat Pump group.
What physical clearance dimensions apply when installing Rheem PROPH80 T2 RH400-SO?
With a 74.2 in. height and 24.3 in. diameter, Rheem PROPH80 T2 RH400-SO fits spaces matching: needs >72 in. overhead clearance; clears 28 in. utility doorway (24.3" d), plus 6–12 in. above for plumbing shutoffs.
What 240V circuit or IFGC fuel line capacity fits Rheem PROPH80 T2 RH400-SO?
Powered via 240V at 21A max, Rheem PROPH80 T2 RH400-SO requires: Requires 240V dedicated branch circuit; check panel capacity. Confirm double-pole breaker sizing and condensate pump outlet proximity.
How do state electricity prices change annual costs for Rheem PROPH80 T2 RH400-SO?
Annual electric spend for Rheem PROPH80 T2 RH400-SO (1,213 kWh/yr) averages $220/yr nationwide (ranging from $177/yr in Washington hydro tiers up to $572/yr in Hawaii), calculated directly from August 2026 EIA Table 5.6.A tariffs.
What homeowner setups should avoid choosing Rheem PROPH80 T2 RH400-SO?
Homes lacking a condensate drain or 240V branch circuit—or unconditioned sub-zero spaces—should verify hybrid backup mode limits on Rheem PROPH80 T2 RH400-SO.
Is Rheem PROPH80 T2 RH400-SO sized adequately for a 2-to-4-person household?
ENERGY STAR certifies Rheem PROPH80 T2 RH400-SO at 87 gal First Hour Rating (+15 gal vs. 72 gal median); match that hourly reserve against simultaneous 2.0 GPM showerheads.
Does Rheem have active CPSC SaferProducts notices affecting PROPH80 T2 RH400-SO?
CPSC SaferProducts records show 4 brand-level recall notices mentioning Rheem as of 2026-11-23, including #16177 (2016-05-26). Enter the rating-plate serial into TapAndPipe's Serial Lookup tool to verify production week.
Which competing water heater matches Rheem PROPH80 T2 RH400-SO (4.07 UEF) most closely?
State-run DOE HEAR programs (<=150% AMI, up to $1,750 for HPWH) and electric utilities lead 2026 incentives for Rheem PROPH80 T2 RH400-SO. Closest peer in Hybrid/Electric Heat Pump is Friedrich PROH80 T2 FD400-30 (4.07 UEF).
Sources
- ENERGY STAR Certified Water Heaters Dataset (Socrata pbpq-swnu) — U.S. EPA & DOE ENERGY STAR, 2026 Live Certified Registry (retrieved 2026-11-23)
- 10 CFR 430.32 — Energy and Water Conservation Standards (Water Heaters & Plumbing Fixtures) — U.S. Department of Energy / eCFR, 2026 eCFR (incl. May 6, 2029 Rule) (retrieved 2026-11-23)
- CPSC SaferProducts.gov Product Recalls REST API — U.S. Consumer Product Safety Commission, 2026 Live Recalls Feed (retrieved 2026-11-23)
- EIA Electric Power Monthly Table 5.6.A — Average Residential Electricity Price by State — U.S. Energy Information Administration (EIA), August 2026 Monthly Release (retrieved 2026-11-23)