Skip to main content
ENERGY STAR water heater model · PD 3994199

Rheem PROUH40 T2 RH350UM Water Heater Specifications (3.5 UEF)

In the 706-unit Hybrid/Electric Heat Pump class, Rheem PROUH40 T2 RH350UM (Electric) achieves a certified 3.5 UEF rating across its 36-gallon nominal tank, 60 gal First Hour Rating (rank #481 of 706, PD 3994199) and verifies as Pass: +1.20 / +52.2% for 2029 DOE floors. Rated annual electricity draw of 879 kWh/yr equates to roughly $160/yr ($1,596 over 10 years) at 18.16 cents/kWh. Closest certified alternative is Friedrich PROH40 T2 FD310BM (3.5 UEF).

Uniform Energy Factor
3.5 UEF
Cohort UEF Rank
#481 of 706
First Hour Rating
60 gal
Storage Volume
36 gal
Fuel / Type
Electric / Hybrid/Electric Heat Pump
DOE 2029 Rule Status
Pass: +1.20 / +52.2%
Hybrid heat pump water heater upper shroud with brass relief valve and insulated copper risers
Hybrid heat pump water heater upper shroud with brass relief valve and insulated copper risers
Hybrid/Electric Heat Pump UEF Efficiency Distribution (706 Certified Units)Distribution of certified UEF ratings across 706 units in Hybrid/Electric Heat Pump, marking Rheem PROUH40 T2 RH350UM at 3.5 UEF.21130201631342031241542.52 UEF4.50 UEFMedian 3.702029 min 2.30Rheem PROUH40 T2 RH350UM: 3.50
Hybrid/Electric Heat Pump UEF Efficiency Distribution (706 Certified Units). Highlighted pin shows Rheem PROUH40 T2 RH350UM relative to the cohort median.
Efficiency comparison & rule summary

Rheem PROUH40 T2 RH350UM records 3.5 UEF efficiency, putting it #481 of 706 among 706 Hybrid/Electric Heat Pump peers.

10 CFR 430.32(d)(2) compliance: Rheem PROUH40 T2 RH350UM exceeds 10 CFR 430.32(d)(2) Electric >35 to <=55 gal (2.30 UEF) by +1.20 UEF (+52.2%). At EIA August 2026 national rates (18.16 cents/kWh), 879 kWh/yr for Rheem PROUH40 T2 RH350UM runs ~$160/yr vs. ~$607/yr for a 0.92 UEF electric tank.

State electric sensitivity for Rheem PROUH40 T2 RH350UM: 10-year operating spend spans $1,286 in Washington (Lowest Hydro Tier) (14.63 cents/kWh) to $4,147 in Hawaii (Highest EIA State) (47.18 cents/kWh).

Competing options beside Rheem PROUH40 T2 RH350UM (3.5 UEF) are Friedrich PROH40 T2 FD310BM (3.5 UEF, at parity) and Ruud PRO H40 T2 RU310BM (3.5 UEF, at parity).

What Physical and Thermal Ratings Define Rheem PROUH40 T2 RH350UM?

Positioning at #481 of 706 out of 706 Hybrid/Electric Heat Pump peers, Rheem PROUH40 T2 RH350UM pairs measured UEF performance with specific clearance and wiring rules.

Certified model attributes compared against 706 ENERGY STAR Hybrid/Electric Heat Pump peers
Specification AttributeCertified ValueCohort Benchmark / DeltaProvenance
Manufacturer / BrandRheem236 certified listingsENERGY STAR PD 3994199
Model NumberPROUH40 T2 RH350UMDraw pattern: Medium-UsagePROUH40 T2 RH350UM
Uniform Energy Factor (UEF)3.5-0.20 UEF vs. 3.70 UEF median10 CFR 430 Test Method
First Hour Rating (FHR)60 gal-12 gal vs. 72 gal median10 CFR 430 Recovery Test
Rated Annual Electricity Use879 kWh/yr-193 kWh/yr vs. 1,072 kWh/yr medianEst. $160/yr @ $0.1816/kWh (EIA US Avg)
Thermal Recovery Efficiency423%-6.0 pts vs. 429.0% medianENERGY STAR Dataset
Physical Envelope (H x Dia)62.3" H x 20.3" DFits standard 72 in. basement/garage clearance; clears 28 in. utility doorway (20.3" D)Doorway & ceiling check
Electrical Circuit Requirements240 V / 21 A maxRequires 240V dedicated branch circuit; check panel capacityNEC / Branch circuit check
Heat Pump Refrigerant & GWPR-134a (GWP:1430)Check regional AIM Act phase-down transitionEPA AIM Act Compliance
Certification Date2026-10-15Certified 2026-10-15Markets: United States

Why Do State Utility Rates Shift PROUH40 T2 RH350UM Running Costs?

Consuming 879 kWh annually puts Rheem PROUH40 T2 RH350UM near $160/yr at US baseline tariffs, with multi-state EIA comparisons charted below.

Estimated Annual Electricity Cost by State Rate (879 kWh/yr)Projected annual electricity spend across five benchmark EIA August 2026 residential electric tiers.United States Average$160.00/yrHawaii$415.00/yrCalifornia$262.00/yrTexas$140.00/yrWashington$129.00/yr
Projected annual electricity spend across five benchmark EIA August 2026 residential electric tiers.
Estimated electricity cost and 10-year spend across benchmark states
Jurisdiction (EIA Aug 2026)Residential RateAnnual Cost10-Yr Operating Spend10-Yr Savings vs. 0.92 UEF
United States Average 18.16 ¢/kWh ($0.1816) $160/yr $1,596 $4,476
Hawaii (Highest EIA State) 47.18 ¢/kWh ($0.4718) $415/yr $4,147 $11,630
California 29.75 ¢/kWh ($0.2975) $262/yr $2,615 $7,333
Texas 15.91 ¢/kWh ($0.1591) $140/yr $1,398 $3,922
Washington (Lowest Hydro Tier) 14.63 ¢/kWh ($0.1463) $129/yr $1,286 $3,606
Estimated electricity spend (879 kWh/yr)

Condensing Gas Tankless vs. Storage Tank Flow Path & Gas Supply Engineering schematic contrasting 199,000 BTU/h condensing tankless piping (3/4 in. gas supply, Category IV PVC vent, condensate drain) against a 40,000 BTU/h atmospheric tank. Condensing Gas Tankless (0.91–0.96 UEF) Secondary HX Cat IV PVC Vent Cold In Hot Out 3/4"–1" Gas 199K BTU/h Condensate Atmospheric Storage Tank (0.58–0.65 UEF) Type B Flue Anode Rod 40K BTU/h 1/2" Gas Up to 100 ft T&P 150 psi 50–85 gal FHR Reserve | 8–12 yr life
Technical comparison: condensing gas tankless units require 3/4 in.–1 in. IFGC Table 402.4 gas supply and Category IV condensate drainage, while atmospheric tanks run on 1/2 in. lines.

Have Any Rheem Series Triggered CPSC Recalls?

SaferProducts records retrieved 2026-11-23 list 4 brand notices under Rheem; inspect model coverage dates prior to valve or anode service. See Serial Number Lookup.

4 Brand Recall Notices Found in CPSC Feed — Verify Serial & Model Range
  • Recall #16177 (2016-05-26): Rheem Recalls to Repair Water Heaters Due to Fire and Burn Hazards; Sold Exclusively at Home Depot (CPSC Notice)
  • Recall #07108 (2007-02-21): Tankless Water Heaters Recalled for Repair Due to Carbon Monoxide Poisoning Hazard (CPSC Notice)
  • Recall #05274 (2005-09-16): CPSC, Robertshaw Controls Co. Announce Recall of Gas Control Valves on Water Heaters (CPSC Notice)
  • Recall #80042 (1980-12-04): LP Gas Water Heaters Repaired by White-Rodgers (CPSC Notice)

What Are 5 Direct Alternatives to Rheem PROUH40 T2 RH350UM?

Homeowners cross-shopping Rheem PROUH40 T2 RH350UM frequently review these five Hybrid/Electric Heat Pump models ranked closest on capacity and UEF output.

5 closest certified peers matched by equipment class, storage volume, and efficiency rating
Brand & ModelTypeVolFHRUEF (Δ)kWh/yr
Friedrich PROH40 T2 FD310BM Hybrid/Electric Heat Pump 36 gal 60 gal 3.5 (at parity) 879
Ruud PRO H40 T2 RU310BM Hybrid/Electric Heat Pump 36 gal 60 gal 3.5 (at parity) 879
Richmond 10CE40-HP5U15 Hybrid/Electric Heat Pump 36 gal 46 gal 3.45 (-0.05) 643
A. O. Smith CAHP-40 2** Hybrid/Electric Heat Pump 36 gal 55 gal 3.6 (+0.10) 902
Friedrich PROH40 T2 FD310UM Hybrid/Electric Heat Pump 36 gal 60 gal 3.5 (at parity) 879

What Are the Limitations of Rheem PROUH40 T2 RH350UM and Who Should Not Install It?

Before ordering Rheem PROUH40 T2 RH350UM (Hybrid/Electric Heat Pump, 3.5 UEF), weigh space clearances, fuel piping, noise (standard dBA), and 2029 rule readiness across three scenarios.

Key Limitations & Exclusions

  • Rheem PROUH40 T2 RH350UM needs >=450 cu ft room air volume or ducting so compressor cooling does not stall recovery.
  • Compressor runs near 49 dBA; avoid mounting Rheem PROUH40 T2 RH350UM directly beside quiet bedrooms.
  • Requires condensate drain routing and 240V electrical capacity; verify state DOE HEAR status.

Which Option Fits Your Situation?

High Electric Rate States Choosing Rheem PROUH40 T2 RH350UM Strong Fit — 3.5 UEF trims electric use ~75% vs 0.92 UEF tanks.
Open Basement or Garage (>=450 cu ft) Strong Fit — Ample ambient air sustains heat-pump-only efficiency.
Small Interior Closet (<300 cu ft) Caution — Add duct kit or compare Friedrich PROH40 T2 FD310BM footprint.

Sizing, Efficiency & Recall Answers for Rheem PROUH40 T2 RH350UM

Direct answers to common technical, regulatory, and sizing questions sourced from primary U.S. government and OEM documentation.

Does Rheem PROUH40 T2 RH350UM pass the May 6, 2029 federal DOE efficiency rule?

Rheem PROUH40 T2 RH350UM carries a verified 3.5 UEF rating (Pass: +1.20 / +52.2%), ranking #481 of 706 across 706 ENERGY STAR Hybrid/Electric Heat Pump models under 10 CFR 430.32.

What doorway width and ceiling height does Rheem PROUH40 T2 RH350UM need?

Rheem PROUH40 T2 RH350UM stands 62.3 in. high with a 20.3 in. diameter; fits standard 72 in. basement/garage clearance; clears 28 in. utility doorway (20.3" d). Leave overhead clearance for dielectric nipples, ball shutoff valves, and top air filters.

What gas pipe size or electrical breaker does Rheem PROUH40 T2 RH350UM require?

Rheem PROUH40 T2 RH350UM uses a 240V branch circuit at 21A max (Requires 240V dedicated branch circuit; check panel capacity). Verify main breaker space before replacing a gas tank with an electric hybrid unit.

How much electricity or energy does Rheem PROUH40 T2 RH350UM cost per year to run?

Rated at 879 kWh/yr, Rheem PROUH40 T2 RH350UM costs about $160/yr ($1,600 over 10 years) at the August 2026 EIA US average of 18.16 cents/kWh (ranging from $129/yr in Washington hydro tiers up to $415/yr in Hawaii).

Who should NOT install Rheem PROUH40 T2 RH350UM, and what are its limits?

Rheem PROUH40 T2 RH350UM (3.5 UEF) is a poor fit for unvented closets under 450 cu ft because compressor intake chills enclosed rooms and runs at 49 dBA.

How many bathrooms or people can Rheem PROUH40 T2 RH350UM serve at peak demand?

Rheem PROUH40 T2 RH350UM achieves a 60 gal First Hour Rating (-12 gal vs. 72 gal median). Two back-to-back showers plus a dishwasher run typically call for 55–70 gal FHR.

Are there CPSC safety recalls or serial checks for Rheem PROUH40 T2 RH350UM?

CPSC SaferProducts records show 4 brand-level recall notices mentioning Rheem as of 2026-11-23, including #16177 (2016-05-26). Enter the rating-plate serial into TapAndPipe's Serial Lookup tool to verify production week.

What 2026 rebates apply to Rheem PROUH40 T2 RH350UM, and what peer compares closest?

Federal Section 25C expired Dec 31, 2025 (P.L. 119-21); qualifying HPWHs remain eligible for state DOE HEAR rebates up to $1,750 (<=150% AMI). Closest peer in Hybrid/Electric Heat Pump is Friedrich PROH40 T2 FD310BM (3.5 UEF).

Sources

  1. ENERGY STAR Certified Water Heaters Dataset (Socrata pbpq-swnu) — U.S. EPA & DOE ENERGY STAR, 2026 Live Certified Registry (retrieved 2026-11-23)
  2. 10 CFR 430.32 — Energy and Water Conservation Standards (Water Heaters & Plumbing Fixtures) — U.S. Department of Energy / eCFR, 2026 eCFR (incl. May 6, 2029 Rule) (retrieved 2026-11-23)
  3. CPSC SaferProducts.gov Product Recalls REST API — U.S. Consumer Product Safety Commission, 2026 Live Recalls Feed (retrieved 2026-11-23)
  4. EIA Electric Power Monthly Table 5.6.A — Average Residential Electricity Price by State — U.S. Energy Information Administration (EIA), August 2026 Monthly Release (retrieved 2026-11-23)

Related U.S. Metro Plumbing Benchmarks