Rheem XE40T10H22U0 Water Heater Specifications (3.45 UEF)
In the 706-unit Hybrid/Electric Heat Pump class, Rheem XE40T10H22U0 (Electric) achieves a certified 3.45 UEF rating across its 36-gallon nominal tank, 46 gal First Hour Rating (rank #563 of 706, PD 2408519) and verifies as Pass: +1.15 / +50.0% for 2029 DOE floors. Rated annual electricity draw of 643 kWh/yr equates to roughly $117/yr ($1,168 over 10 years) at 18.16 cents/kWh. Closest certified alternative is Friedrich PROH40 T2 FD400-15 (3.45 UEF).
- Uniform Energy Factor
- 3.45 UEF
- Cohort UEF Rank
- #563 of 706
- First Hour Rating
- 46 gal
- Storage Volume
- 36 gal
- Fuel / Type
- Electric / Hybrid/Electric Heat Pump
- DOE 2029 Rule Status
- Pass: +1.15 / +50.0%

Rheem XE40T10H22U0 records 3.45 UEF efficiency, putting it #563 of 706 among 706 Hybrid/Electric Heat Pump peers.
10 CFR 430.32(d)(2) compliance: Rheem XE40T10H22U0 exceeds 10 CFR 430.32(d)(2) Electric >35 to <=55 gal (2.30 UEF) by +1.15 UEF (+50.0%). At EIA August 2026 national rates (18.16 cents/kWh), 643 kWh/yr for Rheem XE40T10H22U0 runs ~$117/yr vs. ~$438/yr for a 0.92 UEF electric tank.
State electric sensitivity for Rheem XE40T10H22U0: 10-year operating spend spans $941 in Washington (Lowest Hydro Tier) (14.63 cents/kWh) to $3,034 in Hawaii (Highest EIA State) (47.18 cents/kWh).
Competing options beside Rheem XE40T10H22U0 (3.45 UEF) are Friedrich PROH40 T2 FD400-15 (3.45 UEF, at parity) and Richmond 10CE40-HP5U15 (3.45 UEF, at parity).
How Complete Are the Certified Metrics for Rheem XE40T10H22U0?
Standing at #563 of 706 among 706 certified Hybrid/Electric Heat Pump heaters, Rheem XE40T10H22U0 brings measurable deltas in recovery, footprint, and energy efficiency.
| Specification Attribute | Certified Value | Cohort Benchmark / Delta | Provenance |
|---|---|---|---|
| Manufacturer / Brand | Rheem | 236 certified listings | ENERGY STAR PD 2408519 |
| Model Number | XE40T10H22U0 | Draw pattern: Low-Usage | XE40T10H22U0 |
| Uniform Energy Factor (UEF) | 3.45 | -0.25 UEF vs. 3.70 UEF median | 10 CFR 430 Test Method |
| First Hour Rating (FHR) | 46 gal | -26 gal vs. 72 gal median | 10 CFR 430 Recovery Test |
| Rated Annual Electricity Use | 643 kWh/yr | -429 kWh/yr vs. 1,072 kWh/yr median | Est. $117/yr @ $0.1816/kWh (EIA US Avg) |
| Thermal Recovery Efficiency | 432% | +3.0 pts vs. 429.0% median | ENERGY STAR Dataset |
| Physical Envelope (H x Dia) | 62.3" H x 20.3" D | Fits standard 72 in. basement/garage clearance; clears 28 in. utility doorway (20.3" D) | Doorway & ceiling check |
| Electrical Circuit Requirements | 240 V / 12 A max | Requires 240V dedicated branch circuit; check panel capacity | NEC / Branch circuit check |
| Heat Pump Refrigerant & GWP | R-134a (GWP:1430) | Check regional AIM Act phase-down transition | EPA AIM Act Compliance |
| Certification Date | 2026-10-15 | Certified 2026-10-15 | Markets: United States |
What Is the Projected Utility Bill for XE40T10H22U0 by State?
At 643 kWh/yr, Rheem XE40T10H22U0 averages about $117/yr across US households—see 10-year payback spreads versus 0.92 UEF resistance tanks.
| Jurisdiction (EIA Aug 2026) | Residential Rate | Annual Cost | 10-Yr Operating Spend | 10-Yr Savings vs. 0.92 UEF |
|---|---|---|---|---|
| United States Average | 18.16 ¢/kWh ($0.1816) | $117/yr | $1,168 | $3,211 |
| Hawaii (Highest EIA State) | 47.18 ¢/kWh ($0.4718) | $303/yr | $3,034 | $8,341 |
| California | 29.75 ¢/kWh ($0.2975) | $191/yr | $1,913 | $5,260 |
| Texas | 15.91 ¢/kWh ($0.1591) | $102/yr | $1,023 | $2,813 |
| Washington (Lowest Hydro Tier) | 14.63 ¢/kWh ($0.1463) | $94/yr | $941 | $2,587 |
Are Rheem Models Affected by Current CPSC Notices?
Review 4 brand-matched CPSC entries pulled 2026-11-23 for Rheem and confirm your serial tag before scheduling contractor service. See Serial Number Lookup.
- Recall #16177 (2016-05-26): Rheem Recalls to Repair Water Heaters Due to Fire and Burn Hazards; Sold Exclusively at Home Depot (CPSC Notice)
- Recall #07108 (2007-02-21): Tankless Water Heaters Recalled for Repair Due to Carbon Monoxide Poisoning Hazard (CPSC Notice)
- Recall #05274 (2005-09-16): CPSC, Robertshaw Controls Co. Announce Recall of Gas Control Valves on Water Heaters (CPSC Notice)
- Recall #80042 (1980-12-04): LP Gas Water Heaters Repaired by White-Rodgers (CPSC Notice)
Which 5 Models Offer Similar Output to XE40T10H22U0?
Ordered by minimal capacity and UEF spread relative to Rheem XE40T10H22U0, these five certified peers give direct replacement benchmarks.
| Brand & Model | Type | Vol | FHR | UEF (Δ) | kWh/yr |
|---|---|---|---|---|---|
| Friedrich PROH40 T2 FD400-15 | Hybrid/Electric Heat Pump | 36 gal | 46 gal | 3.45 (at parity) | 643 |
| Richmond 10CE40-HP5U15 | Hybrid/Electric Heat Pump | 36 gal | 46 gal | 3.45 (at parity) | 643 |
| Ruud PROUH40 T2 CD400-15 | Hybrid/Electric Heat Pump | 36 gal | 46 gal | 3.45 (at parity) | 643 |
| A. O. Smith CAHP-40 2** | Hybrid/Electric Heat Pump | 36 gal | 55 gal | 3.6 (+0.15) | 902 |
| Richmond 10E40-HP5U15 | Hybrid/Electric Heat Pump | 36 gal | 46 gal | 3.45 (at parity) | 643 |
What Installation Caveats Apply Before Buying Rheem XE40T10H22U0?
Even high-UEF units like Rheem XE40T10H22U0 (3.45 UEF) carry physical space, condensate, and fuel-line prerequisites noted below.
Key Limitations & Exclusions
- Rheem XE40T10H22U0 needs >=450 cu ft room air volume or ducting so compressor cooling does not stall recovery.
- Compressor runs near 49 dBA; avoid mounting Rheem XE40T10H22U0 directly beside quiet bedrooms.
- Requires condensate drain routing and 240V electrical capacity; verify state DOE HEAR status.
Which Option Fits Your Situation?
Practical Specs & Code Questions for Rheem XE40T10H22U0
Direct answers to common technical, regulatory, and sizing questions sourced from primary U.S. government and OEM documentation.
Is Rheem XE40T10H22U0 eligible for continued manufacture past May 6, 2029?
At 3.45 UEF, Rheem XE40T10H22U0 achieves Pass: +1.15 / +50.0% for the 2029 DOE standard and stands #563 of 706 against Friedrich PROH40 T2 FD400-15 and Richmond 10CE40-HP5U15.
How tall and wide is Rheem XE40T10H22U0, and what service clearance is needed?
Physical dimensions for Rheem XE40T10H22U0 are 62.3 in. height and 20.3 in. diameter (fits standard 72 in. basement/garage clearance; clears 28 in. utility doorway (20.3" d)); verify stair turns and drain pan width before delivery.
Will Rheem XE40T10H22U0 require upgrading household electrical panels or gas piping?
Rheem XE40T10H22U0 draws 240V at 12A max (Requires 240V dedicated branch circuit; check panel capacity); check whether existing 10/2 AWG 30A copper wiring aligns with nameplate amps.
Is Rheem XE40T10H22U0 economical to operate at 18.16 cents/kWh US electric rates?
Expect roughly $117/yr ($1,170 over 10 years) to power Rheem XE40T10H22U0 at 643 kWh/yr under the 18.16 cents/kWh US average (ranging from $94/yr in Washington hydro tiers up to $303/yr in Hawaii).
Which installation bottlenecks limit Rheem XE40T10H22U0?
If ambient room air stays below 40 °F year-round or closet volume falls under 450 cu ft, Rheem XE40T10H22U0 drops into resistance mode more often.
How does Rheem XE40T10H22U0 handle simultaneous showers and laundry?
Delivering 46 gal in the first hour (-26 gal vs. 72 gal median), Rheem XE40T10H22U0 combines 36 gal tank storage with rapid burner/element recovery.
How long is the warranty on Rheem XE40T10H22U0 and how do you decode its serial?
CPSC SaferProducts records show 4 brand-level recall notices mentioning Rheem as of 2026-11-23, including #16177 (2016-05-26). Enter the rating-plate serial into TapAndPipe's Serial Lookup tool to verify production week.
How do 2026 post-OBBBA rebates affect buying Rheem XE40T10H22U0?
Check state energy office HEAR portals and utility rebates in 2026 since federal 25C ended Dec 31, 2025. Closest peer in Hybrid/Electric Heat Pump is Friedrich PROH40 T2 FD400-15 (3.45 UEF).
Sources
- ENERGY STAR Certified Water Heaters Dataset (Socrata pbpq-swnu) — U.S. EPA & DOE ENERGY STAR, 2026 Live Certified Registry (retrieved 2026-11-23)
- 10 CFR 430.32 — Energy and Water Conservation Standards (Water Heaters & Plumbing Fixtures) — U.S. Department of Energy / eCFR, 2026 eCFR (incl. May 6, 2029 Rule) (retrieved 2026-11-23)
- CPSC SaferProducts.gov Product Recalls REST API — U.S. Consumer Product Safety Commission, 2026 Live Recalls Feed (retrieved 2026-11-23)
- EIA Electric Power Monthly Table 5.6.A — Average Residential Electricity Price by State — U.S. Energy Information Administration (EIA), August 2026 Monthly Release (retrieved 2026-11-23)