Skip to main content
ENERGY STAR water heater model · PD 3555173

Rheem XE50T10HMS00U0 Water Heater Specifications (3 UEF)

With PD 3555173 certification, Rheem XE50T10HMS00U0 (Hybrid/Electric Heat Pump, Electric) achieves a certified 3.0 UEF rating across its 46-gallon nominal tank, 55 gal First Hour Rating, standing #666 of 706 across 706 peers with Pass: +0.70 / +30.4% for May 6, 2029. Rated annual electricity draw of 1,072 kWh/yr equates to roughly $195/yr ($1,947 over 10 years) at 18.16 cents/kWh. Closest certified alternative is Friedrich PROH50 T0 FD120-M (3.0 UEF).

Uniform Energy Factor
3.0 UEF
Cohort UEF Rank
#666 of 706
First Hour Rating
55 gal
Storage Volume
46 gal
Fuel / Type
Electric / Hybrid/Electric Heat Pump
DOE 2029 Rule Status
Pass: +0.70 / +30.4%
Hybrid heat pump water heater upper shroud with brass relief valve and insulated copper risers
Hybrid heat pump water heater upper shroud with brass relief valve and insulated copper risers
Hybrid/Electric Heat Pump UEF Efficiency Distribution (706 Certified Units)Distribution of certified UEF ratings across 706 units in Hybrid/Electric Heat Pump, marking Rheem XE50T10HMS00U0 at 3.0 UEF.21130201631342031241542.52 UEF4.50 UEFMedian 3.702029 min 2.30Rheem XE50T10HMS00U0: 3.00
Hybrid/Electric Heat Pump UEF Efficiency Distribution (706 Certified Units). Highlighted pin shows Rheem XE50T10HMS00U0 relative to the cohort median.
Efficiency comparison & rule summary

ENERGY STAR certification places Rheem XE50T10HMS00U0 at 3.0 UEF (#666 of 706; -0.70 UEF vs. 3.70 UEF median) in Hybrid/Electric Heat Pump.

May 6, 2029 readiness: Rheem XE50T10HMS00U0 stands +0.70 UEF (+30.4%) relative to 10 CFR 430.32(d)(2) Electric >35 to <=55 gal (2.30 UEF). At EIA August 2026 national rates (18.16 cents/kWh), 1,072 kWh/yr for Rheem XE50T10HMS00U0 runs ~$195/yr vs. ~$635/yr for a 0.92 UEF electric tank.

State electric sensitivity for Rheem XE50T10HMS00U0: 10-year operating spend spans $1,568 in Washington (Lowest Hydro Tier) (14.63 cents/kWh) to $5,058 in Hawaii (Highest EIA State) (47.18 cents/kWh).

In the Hybrid/Electric Heat Pump tier, Friedrich PROH50 T0 FD120-M (3.0 UEF, at parity) and Richmond 10E50-HP120M (3.0 UEF, at parity) bracket Rheem XE50T10HMS00U0.

How Complete Are the Certified Metrics for Rheem XE50T10HMS00U0?

Standing at #666 of 706 among 706 certified Hybrid/Electric Heat Pump heaters, Rheem XE50T10HMS00U0 brings measurable deltas in recovery, footprint, and energy efficiency.

Certified model attributes compared against 706 ENERGY STAR Hybrid/Electric Heat Pump peers
Specification AttributeCertified ValueCohort Benchmark / DeltaProvenance
Manufacturer / BrandRheem236 certified listingsENERGY STAR PD 3555173
Model NumberXE50T10HMS00U0Draw pattern: Medium-UsageXE50T10HMS00U0
Uniform Energy Factor (UEF)3.0-0.70 UEF vs. 3.70 UEF median10 CFR 430 Test Method
First Hour Rating (FHR)55 gal-17 gal vs. 72 gal median10 CFR 430 Recovery Test
Rated Annual Electricity Use1,072 kWh/yrAt 1,072 kWh/yr medianEst. $195/yr @ $0.1816/kWh (EIA US Avg)
Thermal Recovery Efficiency367%-62.0 pts vs. 429.0% medianENERGY STAR Dataset
Physical Envelope (H x Dia)61.8" H x 22.3" DFits standard 72 in. basement/garage clearance; clears 28 in. utility doorway (22.3" D)Doorway & ceiling check
Electrical Circuit Requirements120 V / 4.5 A max120V plug-in retrofit circuit; slower heat-pump-only recoveryNEC / Branch circuit check
Heat Pump Refrigerant & GWPR-134a (GWP:1430)Check regional AIM Act phase-down transitionEPA AIM Act Compliance
Certification Date2026-10-16Certified 2026-10-16Markets: United States

What Is the Projected Utility Bill for XE50T10HMS00U0 by State?

At 1,072 kWh/yr, Rheem XE50T10HMS00U0 averages about $195/yr across US households—see 10-year payback spreads versus 0.92 UEF resistance tanks.

Estimated Annual Electricity Cost by State Rate (1,072 kWh/yr)Projected annual electricity spend across five benchmark EIA August 2026 residential electric tiers.United States Average$195.00/yrHawaii$506.00/yrCalifornia$319.00/yrTexas$171.00/yrWashington$157.00/yr
Projected annual electricity spend across five benchmark EIA August 2026 residential electric tiers.
Estimated electricity cost and 10-year spend across benchmark states
Jurisdiction (EIA Aug 2026)Residential RateAnnual Cost10-Yr Operating Spend10-Yr Savings vs. 0.92 UEF
United States Average 18.16 ¢/kWh ($0.1816) $195/yr $1,947 $4,402
Hawaii (Highest EIA State) 47.18 ¢/kWh ($0.4718) $506/yr $5,058 $11,436
California 29.75 ¢/kWh ($0.2975) $319/yr $3,189 $7,211
Texas 15.91 ¢/kWh ($0.1591) $171/yr $1,706 $3,857
Washington (Lowest Hydro Tier) 14.63 ¢/kWh ($0.1463) $157/yr $1,568 $3,546
Estimated electricity spend (1,072 kWh/yr)

Condensing Gas Tankless vs. Storage Tank Flow Path & Gas Supply Engineering schematic contrasting 199,000 BTU/h condensing tankless piping (3/4 in. gas supply, Category IV PVC vent, condensate drain) against a 40,000 BTU/h atmospheric tank. Condensing Gas Tankless (0.91–0.96 UEF) Secondary HX Cat IV PVC Vent Cold In Hot Out 3/4"–1" Gas 199K BTU/h Condensate Atmospheric Storage Tank (0.58–0.65 UEF) Type B Flue Anode Rod 40K BTU/h 1/2" Gas Up to 100 ft T&P 150 psi 50–85 gal FHR Reserve | 8–12 yr life
Technical comparison: condensing gas tankless units require 3/4 in.–1 in. IFGC Table 402.4 gas supply and Category IV condensate drainage, while atmospheric tanks run on 1/2 in. lines.

Are Rheem Models Affected by Current CPSC Notices?

Review 4 brand-matched CPSC entries pulled 2026-11-23 for Rheem and confirm your serial tag before scheduling contractor service. See Serial Number Lookup.

4 Brand Recall Notices Found in CPSC Feed — Verify Serial & Model Range
  • Recall #16177 (2016-05-26): Rheem Recalls to Repair Water Heaters Due to Fire and Burn Hazards; Sold Exclusively at Home Depot (CPSC Notice)
  • Recall #07108 (2007-02-21): Tankless Water Heaters Recalled for Repair Due to Carbon Monoxide Poisoning Hazard (CPSC Notice)
  • Recall #05274 (2005-09-16): CPSC, Robertshaw Controls Co. Announce Recall of Gas Control Valves on Water Heaters (CPSC Notice)
  • Recall #80042 (1980-12-04): LP Gas Water Heaters Repaired by White-Rodgers (CPSC Notice)

Which 5 Models Offer Similar Output to XE50T10HMS00U0?

Ordered by minimal capacity and UEF spread relative to Rheem XE50T10HMS00U0, these five certified peers give direct replacement benchmarks.

5 closest certified peers matched by equipment class, storage volume, and efficiency rating
Brand & ModelTypeVolFHRUEF (Δ)kWh/yr
Friedrich PROH50 T0 FD120-M Hybrid/Electric Heat Pump 46 gal 55 gal 3.0 (at parity) 1,072
Richmond 10E50-HP120M Hybrid/Electric Heat Pump 46 gal 55 gal 3.0 (at parity) 1,072
Ruud PROUH50 T0 RU120-M Hybrid/Electric Heat Pump 46 gal 55 gal 3.0 (at parity) 1,072
A. O. Smith HPTV-50 2** Hybrid/Electric Heat Pump 46 gal 52 gal 3.0 (at parity) 1,550
Friedrich PROH50 T0 FD120-MSO Hybrid/Electric Heat Pump 46 gal 55 gal 3.0 (at parity) 1,072

Who Is Rheem XE50T10HMS00U0 Best For — and When Should You Pick Friedrich PROH50 T0 FD120-M?

Evaluate whether Rheem XE50T10HMS00U0's Hybrid/Electric Heat Pump architecture matches your existing mechanical room and local utility tariffs before purchasing.

Key Limitations & Exclusions

  • Rheem XE50T10HMS00U0 needs >=450 cu ft room air volume or ducting so compressor cooling does not stall recovery.
  • Compressor runs near 49 dBA; avoid mounting Rheem XE50T10HMS00U0 directly beside quiet bedrooms.
  • Requires condensate drain routing and 120V electrical capacity; verify state DOE HEAR status.

Which Option Fits Your Situation?

High Electric Rate States Choosing Rheem XE50T10HMS00U0 Strong Fit — 3.0 UEF trims electric use ~75% vs 0.92 UEF tanks.
Open Basement or Garage (>=450 cu ft) Strong Fit — Ample ambient air sustains heat-pump-only efficiency.
Small Interior Closet (<300 cu ft) Caution — Add duct kit or compare Friedrich PROH50 T0 FD120-M footprint.

Practical Specs & Code Questions for Rheem XE50T10HMS00U0

Direct answers to common technical, regulatory, and sizing questions sourced from primary U.S. government and OEM documentation.

How does Rheem XE50T10HMS00U0 (3.0 UEF) compare to 2029 federal DOE floors?

Evaluated against May 6, 2029 10 CFR 430.32 thresholds, Rheem XE50T10HMS00U0 records 3.0 UEF (Pass: +0.70 / +30.4%), placing #666 of 706 out of 706 certified Hybrid/Electric Heat Pump configurations.

Does Rheem XE50T10HMS00U0 fit inside a tight hallway closet or low-headroom utility room?

Rheem XE50T10HMS00U0 requires room for its 61.8 in. vertical shell and 22.3 in. diameter (fits standard 72 in. basement/garage clearance; clears 28 in. utility doorway (22.3" d)), plus service access for annual sediment draining.

What power supply or fuel line specs govern Rheem XE50T10HMS00U0?

For Rheem XE50T10HMS00U0, plan a 120V circuit at 4.5A max (120V plug-in retrofit circuit; slower heat-pump-only recovery) and keep a dedicated shutoff disconnect within sight of the unit.

What annual utility bill should homeowners budget for Rheem XE50T10HMS00U0?

Using 1,072 kWh/yr, Rheem XE50T10HMS00U0 generates an estimated $195/yr electric bill at 18.16 cents/kWh (ranging from $157/yr in Washington hydro tiers up to $506/yr in Hawaii)—use the custom rate slider above for your utility tariff.

What are the main drawbacks of Rheem XE50T10HMS00U0 (3.0 UEF)?

Rheem XE50T10HMS00U0 requires >=450 cu ft air space, 120V electrical supply, and drain access; tight interior alcoves favor ducted adapters or Friedrich PROH50 T0 FD120-M.

What hot-water delivery rating governs Rheem XE50T10HMS00U0?

Rated for 55 gal FHR (-17 gal vs. 72 gal median), Rheem XE50T10HMS00U0 prevents mid-morning cold drops when matched to 55–70+ gal multi-bath household loads.

Where do homeowners screen Rheem XE50T10HMS00U0 for recalls and tank age?

CPSC SaferProducts records show 4 brand-level recall notices mentioning Rheem as of 2026-11-23, including #16177 (2016-05-26). Enter the rating-plate serial into TapAndPipe's Serial Lookup tool to verify production week.

What alternative models sit closest to Rheem XE50T10HMS00U0 in the Hybrid/Electric Heat Pump class?

Closest peer in Hybrid/Electric Heat Pump is Friedrich PROH50 T0 FD120-M (3.0 UEF). For 2026 incentives, look to state DOE HEAR grants ($1,750 max on qualifying HPWHs) and local municipal utility credits.

Sources

  1. ENERGY STAR Certified Water Heaters Dataset (Socrata pbpq-swnu) — U.S. EPA & DOE ENERGY STAR, 2026 Live Certified Registry (retrieved 2026-11-23)
  2. 10 CFR 430.32 — Energy and Water Conservation Standards (Water Heaters & Plumbing Fixtures) — U.S. Department of Energy / eCFR, 2026 eCFR (incl. May 6, 2029 Rule) (retrieved 2026-11-23)
  3. CPSC SaferProducts.gov Product Recalls REST API — U.S. Consumer Product Safety Commission, 2026 Live Recalls Feed (retrieved 2026-11-23)
  4. EIA Electric Power Monthly Table 5.6.A — Average Residential Electricity Price by State — U.S. Energy Information Administration (EIA), August 2026 Monthly Release (retrieved 2026-11-23)

Related U.S. Metro Plumbing Benchmarks