Skip to main content
ENERGY STAR water heater model · PD 3554247

Rheem XE80T10H45U1 Water Heater Specifications (4.07 UEF)

Engineered as a Electric Hybrid/Electric Heat Pump unit, Rheem XE80T10H45U1 achieves a certified 4.07 UEF rating across its 72-gallon nominal tank, 87 gal First Hour Rating and ranks #26 of 706 in its 706-model cohort (PD 3554247), recording Pass: +1.57 / +62.8% under 2029 DOE rules. Rated annual electricity draw of 1,213 kWh/yr equates to roughly $220/yr ($2,203 over 10 years) at 18.16 cents/kWh. Closest certified alternative is Friedrich PROH80 T2 FD400-30 (4.07 UEF).

Uniform Energy Factor
4.07 UEF
Cohort UEF Rank
#26 of 706 (top 8.5%)
First Hour Rating
87 gal
Storage Volume
72 gal
Fuel / Type
Electric / Hybrid/Electric Heat Pump
DOE 2029 Rule Status
Pass: +1.57 / +62.8%
Hybrid heat pump water heater upper shroud with brass relief valve and insulated copper risers
Hybrid heat pump water heater upper shroud with brass relief valve and insulated copper risers
Hybrid/Electric Heat Pump UEF Efficiency Distribution (706 Certified Units)Distribution of certified UEF ratings across 706 units in Hybrid/Electric Heat Pump, marking Rheem XE80T10H45U1 at 4.07 UEF.21130201631342031241542.52 UEF4.50 UEFMedian 3.702029 min 2.50Rheem XE80T10H45U1: 4.07
Hybrid/Electric Heat Pump UEF Efficiency Distribution (706 Certified Units). Highlighted pin shows Rheem XE80T10H45U1 relative to the cohort median.
Efficiency comparison & rule summary

Within the 706-unit Hybrid/Electric Heat Pump cohort, Rheem XE80T10H45U1 logs 4.07 UEF and ranks #26 of 706.

Against 10 CFR 430.32(d)(2) Electric >55 to <=120 gal (2.50 UEF), Rheem XE80T10H45U1 holds a +1.57 UEF (+62.8%) compliance cushion. At EIA August 2026 national rates (18.16 cents/kWh), 1,213 kWh/yr for Rheem XE80T10H45U1 runs ~$220/yr vs. ~$974/yr for a 0.92 UEF electric tank.

State electric sensitivity for Rheem XE80T10H45U1: 10-year operating spend spans $1,775 in Washington (Lowest Hydro Tier) (14.63 cents/kWh) to $5,723 in Hawaii (Highest EIA State) (47.18 cents/kWh).

Cross-shopping Rheem XE80T10H45U1 (4.07 UEF)? Check Friedrich PROH80 T2 FD400-30 (4.07 UEF, at parity) and Richmond 10CE80-HP5S30 (4.07 UEF, at parity).

Which Specs Set Rheem XE80T10H45U1 Apart From Cohort Averages?

Ranked #26 of 706 (top 8.5%) inside the 706-model Hybrid/Electric Heat Pump cohort, Rheem XE80T10H45U1 is evaluated row by row below against category medians.

Certified model attributes compared against 706 ENERGY STAR Hybrid/Electric Heat Pump peers
Specification AttributeCertified ValueCohort Benchmark / DeltaProvenance
Manufacturer / BrandRheem236 certified listingsENERGY STAR PD 3554247
Model NumberXE80T10H45U1Draw pattern: High-UsageXE80T10H45U1
Uniform Energy Factor (UEF)4.07+0.37 UEF vs. 3.70 UEF median10 CFR 430 Test Method
First Hour Rating (FHR)87 gal+15 gal vs. 72 gal median10 CFR 430 Recovery Test
Rated Annual Electricity Use1,213 kWh/yr+141 kWh/yr vs. 1,072 kWh/yr medianEst. $220/yr @ $0.1816/kWh (EIA US Avg)
Thermal Recovery Efficiency447%+18.0 pts vs. 429.0% medianENERGY STAR Dataset
Physical Envelope (H x Dia)74.2" H x 24.3" DNeeds >72 in. overhead clearance; clears 28 in. utility doorway (24.3" D)Doorway & ceiling check
Electrical Circuit Requirements240 V / 21 A maxRequires 240V dedicated branch circuit; check panel capacityNEC / Branch circuit check
Heat Pump Refrigerant & GWPR-134a (GWP:1430)Check regional AIM Act phase-down transitionEPA AIM Act Compliance
Certification Date2026-10-15Certified 2026-10-15Markets: United States

How Do Regional kWh Prices Impact XE80T10H45U1 Over 10 Years?

Using EIA Table 5.6.A benchmarks, Rheem XE80T10H45U1's 1,213 kWh/yr draw translates to roughly $220/yr on typical US residential bills.

Estimated Annual Electricity Cost by State Rate (1,213 kWh/yr)Projected annual electricity spend across five benchmark EIA August 2026 residential electric tiers.United States Average$220.00/yrHawaii$572.00/yrCalifornia$361.00/yrTexas$193.00/yrWashington$177.00/yr
Projected annual electricity spend across five benchmark EIA August 2026 residential electric tiers.
Estimated electricity cost and 10-year spend across benchmark states
Jurisdiction (EIA Aug 2026)Residential RateAnnual Cost10-Yr Operating Spend10-Yr Savings vs. 0.92 UEF
United States Average 18.16 ¢/kWh ($0.1816) $220/yr $2,203 $7,542
Hawaii (Highest EIA State) 47.18 ¢/kWh ($0.4718) $572/yr $5,723 $19,594
California 29.75 ¢/kWh ($0.2975) $361/yr $3,609 $12,355
Texas 15.91 ¢/kWh ($0.1591) $193/yr $1,930 $6,607
Washington (Lowest Hydro Tier) 14.63 ¢/kWh ($0.1463) $177/yr $1,775 $6,076
Estimated electricity spend (1,213 kWh/yr)

Condensing Gas Tankless vs. Storage Tank Flow Path & Gas Supply Engineering schematic contrasting 199,000 BTU/h condensing tankless piping (3/4 in. gas supply, Category IV PVC vent, condensate drain) against a 40,000 BTU/h atmospheric tank. Condensing Gas Tankless (0.91–0.96 UEF) Secondary HX Cat IV PVC Vent Cold In Hot Out 3/4"–1" Gas 199K BTU/h Condensate Atmospheric Storage Tank (0.58–0.65 UEF) Type B Flue Anode Rod 40K BTU/h 1/2" Gas Up to 100 ft T&P 150 psi 50–85 gal FHR Reserve | 8–12 yr life
Technical comparison: condensing gas tankless units require 3/4 in.–1 in. IFGC Table 402.4 gas supply and Category IV condensate drainage, while atmospheric tanks run on 1/2 in. lines.

What Should Rheem Owners Check in CPSC Recall Logs?

The 2026-11-23 CPSC SaferProducts snapshot includes 4 filings tied to Rheem; verify whether your XE80T10H45U1 production run falls inside affected ranges. See Serial Number Lookup.

4 Brand Recall Notices Found in CPSC Feed — Verify Serial & Model Range
  • Recall #16177 (2016-05-26): Rheem Recalls to Repair Water Heaters Due to Fire and Burn Hazards; Sold Exclusively at Home Depot (CPSC Notice)
  • Recall #07108 (2007-02-21): Tankless Water Heaters Recalled for Repair Due to Carbon Monoxide Poisoning Hazard (CPSC Notice)
  • Recall #05274 (2005-09-16): CPSC, Robertshaw Controls Co. Announce Recall of Gas Control Valves on Water Heaters (CPSC Notice)
  • Recall #80042 (1980-12-04): LP Gas Water Heaters Repaired by White-Rodgers (CPSC Notice)

How Do Five Nearby Hybrid/Electric Heat Pump Models Stack Up?

Five alternative Hybrid/Electric Heat Pump units with nearly identical gallon storage and UEF scores are listed below alongside exact efficiency spreads.

5 closest certified peers matched by equipment class, storage volume, and efficiency rating
Brand & ModelTypeVolFHRUEF (Δ)kWh/yr
Friedrich PROH80 T2 FD400-30 Hybrid/Electric Heat Pump 72 gal 87 gal 4.07 (at parity) 1,213
Richmond 10CE80-HP5S30 Hybrid/Electric Heat Pump 72 gal 87 gal 4.07 (at parity) 1,213
Ruud CPROPH80 T2 CD375-30 Hybrid/Electric Heat Pump 72 gal 87 gal 4.07 (at parity) 1,213
LG APHWC802D Hybrid/Electric Heat Pump 72 gal 91 gal 4.1 (+0.03) 1,210
Friedrich PROH80 T2 FD400-SO Hybrid/Electric Heat Pump 72 gal 87 gal 4.07 (at parity) 1,213

Who Is Rheem XE80T10H45U1 Best For — and When Should You Pick Friedrich PROH80 T2 FD400-30?

Evaluate whether Rheem XE80T10H45U1's Hybrid/Electric Heat Pump architecture matches your existing mechanical room and local utility tariffs before purchasing.

Key Limitations & Exclusions

  • Rheem XE80T10H45U1 needs >=450 cu ft room air volume or ducting so compressor cooling does not stall recovery.
  • Compressor runs near 49 dBA; avoid mounting Rheem XE80T10H45U1 directly beside quiet bedrooms.
  • Requires condensate drain routing and 240V electrical capacity; verify state DOE HEAR status.

Which Option Fits Your Situation?

High Electric Rate States Choosing Rheem XE80T10H45U1 Strong Fit — 4.07 UEF trims electric use ~75% vs 0.92 UEF tanks.
Open Basement or Garage (>=450 cu ft) Strong Fit — Ample ambient air sustains heat-pump-only efficiency.
Small Interior Closet (<300 cu ft) Caution — Add duct kit or compare Friedrich PROH80 T2 FD400-30 footprint.

Frequently Asked Technical Questions: Rheem XE80T10H45U1

Direct answers to common technical, regulatory, and sizing questions sourced from primary U.S. government and OEM documentation.

How does Rheem XE80T10H45U1 (4.07 UEF) compare to 2029 federal DOE floors?

Evaluated against May 6, 2029 10 CFR 430.32 thresholds, Rheem XE80T10H45U1 records 4.07 UEF (Pass: +1.57 / +62.8%), placing #26 of 706 (top 8.5%) out of 706 certified Hybrid/Electric Heat Pump configurations.

Does Rheem XE80T10H45U1 fit inside a tight hallway closet or low-headroom utility room?

Rheem XE80T10H45U1 requires room for its 74.2 in. vertical shell and 24.3 in. diameter (needs >72 in. overhead clearance; clears 28 in. utility doorway (24.3" d)), plus service access for annual sediment draining.

What power supply or fuel line specs govern Rheem XE80T10H45U1?

For Rheem XE80T10H45U1, plan a 240V circuit at 21A max (Requires 240V dedicated branch circuit; check panel capacity) and keep a dedicated shutoff disconnect within sight of the unit.

What annual utility bill should homeowners budget for Rheem XE80T10H45U1?

Using 1,213 kWh/yr, Rheem XE80T10H45U1 generates an estimated $220/yr electric bill at 18.16 cents/kWh (ranging from $177/yr in Washington hydro tiers up to $572/yr in Hawaii)—use the custom rate slider above for your utility tariff.

What are the main drawbacks of Rheem XE80T10H45U1 (4.07 UEF)?

Rheem XE80T10H45U1 requires >=450 cu ft air space, 240V electrical supply, and drain access; tight interior alcoves favor ducted adapters or Friedrich PROH80 T2 FD400-30.

What hot-water delivery rating governs Rheem XE80T10H45U1?

Rated for 87 gal FHR (+15 gal vs. 72 gal median), Rheem XE80T10H45U1 prevents mid-morning cold drops when matched to 55–70+ gal multi-bath household loads.

Where do homeowners screen Rheem XE80T10H45U1 for recalls and tank age?

CPSC SaferProducts records show 4 brand-level recall notices mentioning Rheem as of 2026-11-23, including #16177 (2016-05-26). Enter the rating-plate serial into TapAndPipe's Serial Lookup tool to verify production week.

What alternative models sit closest to Rheem XE80T10H45U1 in the Hybrid/Electric Heat Pump class?

Closest peer in Hybrid/Electric Heat Pump is Friedrich PROH80 T2 FD400-30 (4.07 UEF). For 2026 incentives, look to state DOE HEAR grants ($1,750 max on qualifying HPWHs) and local municipal utility credits.

Sources

  1. ENERGY STAR Certified Water Heaters Dataset (Socrata pbpq-swnu) — U.S. EPA & DOE ENERGY STAR, 2026 Live Certified Registry (retrieved 2026-11-23)
  2. 10 CFR 430.32 — Energy and Water Conservation Standards (Water Heaters & Plumbing Fixtures) — U.S. Department of Energy / eCFR, 2026 eCFR (incl. May 6, 2029 Rule) (retrieved 2026-11-23)
  3. CPSC SaferProducts.gov Product Recalls REST API — U.S. Consumer Product Safety Commission, 2026 Live Recalls Feed (retrieved 2026-11-23)
  4. EIA Electric Power Monthly Table 5.6.A — Average Residential Electricity Price by State — U.S. Energy Information Administration (EIA), August 2026 Monthly Release (retrieved 2026-11-23)

Related U.S. Metro Plumbing Benchmarks