Rheem XE80T10HM00U0 Water Heater Specifications (3.46 UEF)
Certified at 3.46 UEF across its 72-gallon nominal tank, 84 gal First Hour Rating, Rheem XE80T10HM00U0 (Hybrid/Electric Heat Pump, Electric) places #549 of 706 out of 706 ENERGY STAR models (PD 3555356). Its May 6, 2029 10 CFR 430.32 status reads Pass: +0.96 / +38.4%. Rated annual electricity draw of 1,403 kWh/yr equates to roughly $255/yr ($2,548 over 10 years) at 18.16 cents/kWh. Closest certified alternative is Friedrich PROH80 T0 FD120-M (3.46 UEF).
- Uniform Energy Factor
- 3.46 UEF
- Cohort UEF Rank
- #549 of 706
- First Hour Rating
- 84 gal
- Storage Volume
- 72 gal
- Fuel / Type
- Electric / Hybrid/Electric Heat Pump
- DOE 2029 Rule Status
- Pass: +0.96 / +38.4%

Tested at 3.46 UEF, Rheem XE80T10HM00U0 places #549 of 706 across 706 certified Hybrid/Electric Heat Pump configurations (-0.24 UEF vs. 3.70 UEF median).
Rheem XE80T10HM00U0 clears 10 CFR 430.32(d)(2) Electric >55 to <=120 gal (2.50 UEF) by +0.96 UEF (+38.4% headroom). At EIA August 2026 national rates (18.16 cents/kWh), 1,403 kWh/yr for Rheem XE80T10HM00U0 runs ~$255/yr vs. ~$958/yr for a 0.92 UEF electric tank.
State electric sensitivity for Rheem XE80T10HM00U0: 10-year operating spend spans $2,053 in Washington (Lowest Hydro Tier) (14.63 cents/kWh) to $6,619 in Hawaii (Highest EIA State) (47.18 cents/kWh).
Closest alternatives to Rheem XE80T10HM00U0 include Friedrich PROH80 T0 FD120-M (3.46 UEF, at parity) alongside Richmond 10E80-HP120M (3.46 UEF, at parity).
How Complete Are the Certified Metrics for Rheem XE80T10HM00U0?
Standing at #549 of 706 among 706 certified Hybrid/Electric Heat Pump heaters, Rheem XE80T10HM00U0 brings measurable deltas in recovery, footprint, and energy efficiency.
| Specification Attribute | Certified Value | Cohort Benchmark / Delta | Provenance |
|---|---|---|---|
| Manufacturer / Brand | Rheem | 236 certified listings | ENERGY STAR PD 3555356 |
| Model Number | XE80T10HM00U0 | Draw pattern: High-Usage | XE80T10HM00U0 |
| Uniform Energy Factor (UEF) | 3.46 | -0.24 UEF vs. 3.70 UEF median | 10 CFR 430 Test Method |
| First Hour Rating (FHR) | 84 gal | +12 gal vs. 72 gal median | 10 CFR 430 Recovery Test |
| Rated Annual Electricity Use | 1,403 kWh/yr | +331 kWh/yr vs. 1,072 kWh/yr median | Est. $255/yr @ $0.1816/kWh (EIA US Avg) |
| Thermal Recovery Efficiency | 393% | -36.0 pts vs. 429.0% median | ENERGY STAR Dataset |
| Physical Envelope (H x Dia) | 74.2" H x 24.3" D | Needs >72 in. overhead clearance; clears 28 in. utility doorway (24.3" D) | Doorway & ceiling check |
| Electrical Circuit Requirements | 120 V / 12 A max | 120V plug-in retrofit circuit; slower heat-pump-only recovery | NEC / Branch circuit check |
| Heat Pump Refrigerant & GWP | R-134a (GWP:1430) | Check regional AIM Act phase-down transition | EPA AIM Act Compliance |
| Certification Date | 2026-10-16 | Certified 2026-10-16 | Markets: United States, Canada |
What Is the Projected Utility Bill for XE80T10HM00U0 by State?
At 1,403 kWh/yr, Rheem XE80T10HM00U0 averages about $255/yr across US households—see 10-year payback spreads versus 0.92 UEF resistance tanks.
| Jurisdiction (EIA Aug 2026) | Residential Rate | Annual Cost | 10-Yr Operating Spend | 10-Yr Savings vs. 0.92 UEF |
|---|---|---|---|---|
| United States Average | 18.16 ¢/kWh ($0.1816) | $255/yr | $2,548 | $7,033 |
| Hawaii (Highest EIA State) | 47.18 ¢/kWh ($0.4718) | $662/yr | $6,619 | $18,273 |
| California | 29.75 ¢/kWh ($0.2975) | $417/yr | $4,174 | $11,522 |
| Texas | 15.91 ¢/kWh ($0.1591) | $223/yr | $2,232 | $6,162 |
| Washington (Lowest Hydro Tier) | 14.63 ¢/kWh ($0.1463) | $205/yr | $2,053 | $5,666 |
Are Rheem Models Affected by Current CPSC Notices?
Review 4 brand-matched CPSC entries pulled 2026-11-23 for Rheem and confirm your serial tag before scheduling contractor service. See Serial Number Lookup.
- Recall #16177 (2016-05-26): Rheem Recalls to Repair Water Heaters Due to Fire and Burn Hazards; Sold Exclusively at Home Depot (CPSC Notice)
- Recall #07108 (2007-02-21): Tankless Water Heaters Recalled for Repair Due to Carbon Monoxide Poisoning Hazard (CPSC Notice)
- Recall #05274 (2005-09-16): CPSC, Robertshaw Controls Co. Announce Recall of Gas Control Valves on Water Heaters (CPSC Notice)
- Recall #80042 (1980-12-04): LP Gas Water Heaters Repaired by White-Rodgers (CPSC Notice)
Which 5 Models Offer Similar Output to XE80T10HM00U0?
Ordered by minimal capacity and UEF spread relative to Rheem XE80T10HM00U0, these five certified peers give direct replacement benchmarks.
| Brand & Model | Type | Vol | FHR | UEF (Δ) | kWh/yr |
|---|---|---|---|---|---|
| Friedrich PROH80 T0 FD120-M | Hybrid/Electric Heat Pump | 72 gal | 84 gal | 3.46 (at parity) | 1,403 |
| Richmond 10E80-HP120M | Hybrid/Electric Heat Pump | 72 gal | 84 gal | 3.46 (at parity) | 1,403 |
| Ruud PROUH80 T0 RU120-M | Hybrid/Electric Heat Pump | 72 gal | 84 gal | 3.46 (at parity) | 1,403 |
| LG APHWC801D | Hybrid/Electric Heat Pump | 72 gal | 94 gal | 3.9 (+0.44) | 1,272 |
| Friedrich PROH80 T0 FD120-MSO | Hybrid/Electric Heat Pump | 72 gal | 84 gal | 3.46 (at parity) | 1,403 |
What Installation Caveats Apply Before Buying Rheem XE80T10HM00U0?
Even high-UEF units like Rheem XE80T10HM00U0 (3.46 UEF) carry physical space, condensate, and fuel-line prerequisites noted below.
Key Limitations & Exclusions
- Rheem XE80T10HM00U0 needs >=450 cu ft room air volume or ducting so compressor cooling does not stall recovery.
- Compressor runs near 49 dBA; avoid mounting Rheem XE80T10HM00U0 directly beside quiet bedrooms.
- Requires condensate drain routing and 120V electrical capacity; verify state DOE HEAR status.
Which Option Fits Your Situation?
Practical Specs & Code Questions for Rheem XE80T10HM00U0
Direct answers to common technical, regulatory, and sizing questions sourced from primary U.S. government and OEM documentation.
Is Rheem XE80T10HM00U0 eligible for continued manufacture past May 6, 2029?
At 3.46 UEF, Rheem XE80T10HM00U0 achieves Pass: +0.96 / +38.4% for the 2029 DOE standard and stands #549 of 706 against Friedrich PROH80 T0 FD120-M and Richmond 10E80-HP120M.
How tall and wide is Rheem XE80T10HM00U0, and what service clearance is needed?
Physical dimensions for Rheem XE80T10HM00U0 are 74.2 in. height and 24.3 in. diameter (needs >72 in. overhead clearance; clears 28 in. utility doorway (24.3" d)); verify stair turns and drain pan width before delivery.
Will Rheem XE80T10HM00U0 require upgrading household electrical panels or gas piping?
Rheem XE80T10HM00U0 draws 120V at 12A max (120V plug-in retrofit circuit; slower heat-pump-only recovery); check whether existing 10/2 AWG 30A copper wiring aligns with nameplate amps.
Is Rheem XE80T10HM00U0 economical to operate at 18.16 cents/kWh US electric rates?
Expect roughly $255/yr ($2,550 over 10 years) to power Rheem XE80T10HM00U0 at 1,403 kWh/yr under the 18.16 cents/kWh US average (ranging from $205/yr in Washington hydro tiers up to $662/yr in Hawaii).
Which installation bottlenecks limit Rheem XE80T10HM00U0?
If ambient room air stays below 40 °F year-round or closet volume falls under 450 cu ft, Rheem XE80T10HM00U0 drops into resistance mode more often.
How does Rheem XE80T10HM00U0 handle simultaneous showers and laundry?
Delivering 84 gal in the first hour (+12 gal vs. 72 gal median), Rheem XE80T10HM00U0 combines 72 gal tank storage with rapid burner/element recovery.
How long is the warranty on Rheem XE80T10HM00U0 and how do you decode its serial?
CPSC SaferProducts records show 4 brand-level recall notices mentioning Rheem as of 2026-11-23, including #16177 (2016-05-26). Enter the rating-plate serial into TapAndPipe's Serial Lookup tool to verify production week.
How do 2026 post-OBBBA rebates affect buying Rheem XE80T10HM00U0?
Check state energy office HEAR portals and utility rebates in 2026 since federal 25C ended Dec 31, 2025. Closest peer in Hybrid/Electric Heat Pump is Friedrich PROH80 T0 FD120-M (3.46 UEF).
Sources
- ENERGY STAR Certified Water Heaters Dataset (Socrata pbpq-swnu) — U.S. EPA & DOE ENERGY STAR, 2026 Live Certified Registry (retrieved 2026-11-23)
- 10 CFR 430.32 — Energy and Water Conservation Standards (Water Heaters & Plumbing Fixtures) — U.S. Department of Energy / eCFR, 2026 eCFR (incl. May 6, 2029 Rule) (retrieved 2026-11-23)
- CPSC SaferProducts.gov Product Recalls REST API — U.S. Consumer Product Safety Commission, 2026 Live Recalls Feed (retrieved 2026-11-23)
- EIA Electric Power Monthly Table 5.6.A — Average Residential Electricity Price by State — U.S. Energy Information Administration (EIA), August 2026 Monthly Release (retrieved 2026-11-23)