Skip to main content
ENERGY STAR water heater model · PD 3555355

Rheem XE80T10HMS00U0 Water Heater Specifications (3.46 UEF)

The Rheem XE80T10HMS00U0 (Hybrid/Electric Heat Pump, Electric) achieves a certified 3.46 UEF rating across its 72-gallon nominal tank, 84 gal First Hour Rating, ranking #549 of 706 among 706 ENERGY STAR Hybrid/Electric Heat Pump models (PD 3555355). Under the May 6, 2029 DOE 10 CFR 430.32(d)(2) standard, compliance status is Pass: +0.96 / +38.4%. Rated annual electricity draw of 1,403 kWh/yr equates to roughly $255/yr ($2,548 over 10 years) at 18.16 cents/kWh. Closest certified alternative is Friedrich PROH80 T0 FD120-M (3.46 UEF).

Uniform Energy Factor
3.46 UEF
Cohort UEF Rank
#549 of 706
First Hour Rating
84 gal
Storage Volume
72 gal
Fuel / Type
Electric / Hybrid/Electric Heat Pump
DOE 2029 Rule Status
Pass: +0.96 / +38.4%
Hybrid heat pump water heater upper shroud with brass relief valve and insulated copper risers
Hybrid heat pump water heater upper shroud with brass relief valve and insulated copper risers
Hybrid/Electric Heat Pump UEF Efficiency Distribution (706 Certified Units)Distribution of certified UEF ratings across 706 units in Hybrid/Electric Heat Pump, marking Rheem XE80T10HMS00U0 at 3.46 UEF.21130201631342031241542.52 UEF4.50 UEFMedian 3.702029 min 2.50Rheem XE80T10HMS00U0: 3.46
Hybrid/Electric Heat Pump UEF Efficiency Distribution (706 Certified Units). Highlighted pin shows Rheem XE80T10HMS00U0 relative to the cohort median.
Efficiency comparison & rule summary

Rheem XE80T10HMS00U0 (3.46 UEF) ranks #549 of 706 Hybrid/Electric Heat Pump models — 14-way tie; more efficient than 20.4% of Hybrid/Electric Heat Pump models, -0.24 UEF below the 3.70 UEF median.

Federal 2029 margin for Rheem XE80T10HMS00U0: +0.96 UEF (+38.4%) vs. 10 CFR 430.32(d)(2) Electric >55 to <=120 gal (2.50 UEF). At EIA August 2026 national rates (18.16 cents/kWh), 1,403 kWh/yr for Rheem XE80T10HMS00U0 runs ~$255/yr vs. ~$958/yr for a 0.92 UEF electric tank.

State electric sensitivity for Rheem XE80T10HMS00U0: 10-year operating spend spans $2,053 in Washington (Lowest Hydro Tier) (14.63 cents/kWh) to $6,619 in Hawaii (Highest EIA State) (47.18 cents/kWh).

Peer comparison: Rheem XE80T10HMS00U0 (3.46 UEF) compares closely with Friedrich PROH80 T0 FD120-M (3.46 UEF, at parity) and Richmond 10E80-HP120M (3.46 UEF, at parity).

How Do Rheem XE80T10HMS00U0 Specs Compare to Hybrid/Electric Heat Pump Medians?

Rheem XE80T10HMS00U0 places #549 of 706 across 706 certified Hybrid/Electric Heat Pump configurations, with physical dimensions, draw profile, and thermal metrics benchmarked below.

Certified model attributes compared against 706 ENERGY STAR Hybrid/Electric Heat Pump peers
Specification AttributeCertified ValueCohort Benchmark / DeltaProvenance
Manufacturer / BrandRheem236 certified listingsENERGY STAR PD 3555355
Model NumberXE80T10HMS00U0Draw pattern: High-UsageXE80T10HMS00U0
Uniform Energy Factor (UEF)3.46-0.24 UEF vs. 3.70 UEF median10 CFR 430 Test Method
First Hour Rating (FHR)84 gal+12 gal vs. 72 gal median10 CFR 430 Recovery Test
Rated Annual Electricity Use1,403 kWh/yr+331 kWh/yr vs. 1,072 kWh/yr medianEst. $255/yr @ $0.1816/kWh (EIA US Avg)
Thermal Recovery Efficiency393%-36.0 pts vs. 429.0% medianENERGY STAR Dataset
Physical Envelope (H x Dia)74.2" H x 24.3" DNeeds >72 in. overhead clearance; clears 28 in. utility doorway (24.3" D)Doorway & ceiling check
Electrical Circuit Requirements120 V / 12 A max120V plug-in retrofit circuit; slower heat-pump-only recoveryNEC / Branch circuit check
Heat Pump Refrigerant & GWPR-134a (GWP:1430)Check regional AIM Act phase-down transitionEPA AIM Act Compliance
Certification Date2026-10-16Certified 2026-10-16Markets: United States, Canada

What Does XE80T10HMS00U0 Cost to Operate Across State Electricity Rates?

At 1,403 kWh/yr, Rheem XE80T10HMS00U0 runs roughly $255/yr on the EIA national average tier under August 2026 Table 5.6.A rates.

Estimated Annual Electricity Cost by State Rate (1,403 kWh/yr)Projected annual electricity spend across five benchmark EIA August 2026 residential electric tiers.United States Average$255.00/yrHawaii$662.00/yrCalifornia$417.00/yrTexas$223.00/yrWashington$205.00/yr
Projected annual electricity spend across five benchmark EIA August 2026 residential electric tiers.
Estimated electricity cost and 10-year spend across benchmark states
Jurisdiction (EIA Aug 2026)Residential RateAnnual Cost10-Yr Operating Spend10-Yr Savings vs. 0.92 UEF
United States Average 18.16 ¢/kWh ($0.1816) $255/yr $2,548 $7,033
Hawaii (Highest EIA State) 47.18 ¢/kWh ($0.4718) $662/yr $6,619 $18,273
California 29.75 ¢/kWh ($0.2975) $417/yr $4,174 $11,522
Texas 15.91 ¢/kWh ($0.1591) $223/yr $2,232 $6,162
Washington (Lowest Hydro Tier) 14.63 ¢/kWh ($0.1463) $205/yr $2,053 $5,666
Estimated electricity spend (1,403 kWh/yr)

Condensing Gas Tankless vs. Storage Tank Flow Path & Gas Supply Engineering schematic contrasting 199,000 BTU/h condensing tankless piping (3/4 in. gas supply, Category IV PVC vent, condensate drain) against a 40,000 BTU/h atmospheric tank. Condensing Gas Tankless (0.91–0.96 UEF) Secondary HX Cat IV PVC Vent Cold In Hot Out 3/4"–1" Gas 199K BTU/h Condensate Atmospheric Storage Tank (0.58–0.65 UEF) Type B Flue Anode Rod 40K BTU/h 1/2" Gas Up to 100 ft T&P 150 psi 50–85 gal FHR Reserve | 8–12 yr life
Technical comparison: condensing gas tankless units require 3/4 in.–1 in. IFGC Table 402.4 gas supply and Category IV condensate drainage, while atmospheric tanks run on 1/2 in. lines.

Are There Active CPSC Safety Recalls for Rheem Water Heaters?

Our 2026-11-23 CPSC SaferProducts query surfaced 4 brand-level recall notices associated with Rheem; match your serial plate before repair. See Serial Number Lookup.

4 Brand Recall Notices Found in CPSC Feed — Verify Serial & Model Range
  • Recall #16177 (2016-05-26): Rheem Recalls to Repair Water Heaters Due to Fire and Burn Hazards; Sold Exclusively at Home Depot (CPSC Notice)
  • Recall #07108 (2007-02-21): Tankless Water Heaters Recalled for Repair Due to Carbon Monoxide Poisoning Hazard (CPSC Notice)
  • Recall #05274 (2005-09-16): CPSC, Robertshaw Controls Co. Announce Recall of Gas Control Valves on Water Heaters (CPSC Notice)
  • Recall #80042 (1980-12-04): LP Gas Water Heaters Repaired by White-Rodgers (CPSC Notice)

Which Certified Water Heaters Match XE80T10HMS00U0 Most Closely?

These 5 competing Hybrid/Electric Heat Pump units sit nearest to Rheem XE80T10HMS00U0 by storage capacity and 3.46 UEF rating.

5 closest certified peers matched by equipment class, storage volume, and efficiency rating
Brand & ModelTypeVolFHRUEF (Δ)kWh/yr
Friedrich PROH80 T0 FD120-M Hybrid/Electric Heat Pump 72 gal 84 gal 3.46 (at parity) 1,403
Richmond 10E80-HP120M Hybrid/Electric Heat Pump 72 gal 84 gal 3.46 (at parity) 1,403
Ruud PROUH80 T0 RU120-M Hybrid/Electric Heat Pump 72 gal 84 gal 3.46 (at parity) 1,403
LG APHWC801D Hybrid/Electric Heat Pump 72 gal 94 gal 3.9 (+0.44) 1,272
Friedrich PROH80 T0 FD120-MSO Hybrid/Electric Heat Pump 72 gal 84 gal 3.46 (at parity) 1,403

Which Home Setups Are NOT a Fit for Rheem XE80T10HMS00U0?

Comparing Rheem XE80T10HMS00U0 against Friedrich PROH80 T0 FD120-M requires checking closet airflow, IFGC gas or 240V electrical sizing, and May 6, 2029 compliance.

Key Limitations & Exclusions

  • Rheem XE80T10HMS00U0 needs >=450 cu ft room air volume or ducting so compressor cooling does not stall recovery.
  • Compressor runs near 49 dBA; avoid mounting Rheem XE80T10HMS00U0 directly beside quiet bedrooms.
  • Requires condensate drain routing and 120V electrical capacity; verify state DOE HEAR status.

Which Option Fits Your Situation?

High Electric Rate States Choosing Rheem XE80T10HMS00U0 Strong Fit — 3.46 UEF trims electric use ~75% vs 0.92 UEF tanks.
Open Basement or Garage (>=450 cu ft) Strong Fit — Ample ambient air sustains heat-pump-only efficiency.
Small Interior Closet (<300 cu ft) Caution — Add duct kit or compare Friedrich PROH80 T0 FD120-M footprint.

What Are the Key Questions About Rheem XE80T10HMS00U0?

Direct answers to common technical, regulatory, and sizing questions sourced from primary U.S. government and OEM documentation.

How does Rheem XE80T10HMS00U0 score under 10 CFR 430.32 May 2029 water heater minimums?

Federal 10 CFR 430.32 rules set the May 6, 2029 manufacturing baseline; Rheem XE80T10HMS00U0 logs 3.46 UEF (Pass: +0.96 / +38.4%) within the 706-unit Hybrid/Electric Heat Pump group.

What physical clearance dimensions apply when installing Rheem XE80T10HMS00U0?

With a 74.2 in. height and 24.3 in. diameter, Rheem XE80T10HMS00U0 fits spaces matching: needs >72 in. overhead clearance; clears 28 in. utility doorway (24.3" d), plus 6–12 in. above for plumbing shutoffs.

What 240V circuit or IFGC fuel line capacity fits Rheem XE80T10HMS00U0?

Powered via 120V at 12A max, Rheem XE80T10HMS00U0 requires: 120V plug-in retrofit circuit; slower heat-pump-only recovery. Confirm double-pole breaker sizing and condensate pump outlet proximity.

How do state electricity prices change annual costs for Rheem XE80T10HMS00U0?

Annual electric spend for Rheem XE80T10HMS00U0 (1,403 kWh/yr) averages $255/yr nationwide (ranging from $205/yr in Washington hydro tiers up to $662/yr in Hawaii), calculated directly from August 2026 EIA Table 5.6.A tariffs.

What homeowner setups should avoid choosing Rheem XE80T10HMS00U0?

Homes lacking a condensate drain or 120V branch circuit—or unconditioned sub-zero spaces—should verify hybrid backup mode limits on Rheem XE80T10HMS00U0.

Is Rheem XE80T10HMS00U0 sized adequately for a 2-to-4-person household?

ENERGY STAR certifies Rheem XE80T10HMS00U0 at 84 gal First Hour Rating (+12 gal vs. 72 gal median); match that hourly reserve against simultaneous 2.0 GPM showerheads.

Does Rheem have active CPSC SaferProducts notices affecting XE80T10HMS00U0?

CPSC SaferProducts records show 4 brand-level recall notices mentioning Rheem as of 2026-11-23, including #16177 (2016-05-26). Enter the rating-plate serial into TapAndPipe's Serial Lookup tool to verify production week.

Which competing water heater matches Rheem XE80T10HMS00U0 (3.46 UEF) most closely?

State-run DOE HEAR programs (<=150% AMI, up to $1,750 for HPWH) and electric utilities lead 2026 incentives for Rheem XE80T10HMS00U0. Closest peer in Hybrid/Electric Heat Pump is Friedrich PROH80 T0 FD120-M (3.46 UEF).

Sources

  1. ENERGY STAR Certified Water Heaters Dataset (Socrata pbpq-swnu) — U.S. EPA & DOE ENERGY STAR, 2026 Live Certified Registry (retrieved 2026-11-23)
  2. 10 CFR 430.32 — Energy and Water Conservation Standards (Water Heaters & Plumbing Fixtures) — U.S. Department of Energy / eCFR, 2026 eCFR (incl. May 6, 2029 Rule) (retrieved 2026-11-23)
  3. CPSC SaferProducts.gov Product Recalls REST API — U.S. Consumer Product Safety Commission, 2026 Live Recalls Feed (retrieved 2026-11-23)
  4. EIA Electric Power Monthly Table 5.6.A — Average Residential Electricity Price by State — U.S. Energy Information Administration (EIA), August 2026 Monthly Release (retrieved 2026-11-23)

Related U.S. Metro Plumbing Benchmarks