Rheem XE80T10HS45U0 Water Heater Specifications (4.07 UEF)
In the 706-unit Hybrid/Electric Heat Pump class, Rheem XE80T10HS45U0 (Electric) achieves a certified 4.07 UEF rating across its 72-gallon nominal tank, 87 gal First Hour Rating (rank #26 of 706, PD 2408549) and verifies as Pass: +1.57 / +62.8% for 2029 DOE floors. Rated annual electricity draw of 1,213 kWh/yr equates to roughly $220/yr ($2,203 over 10 years) at 18.16 cents/kWh. Closest certified alternative is Friedrich PROH80 T2 FD400-30 (4.07 UEF).
- Uniform Energy Factor
- 4.07 UEF
- Cohort UEF Rank
- #26 of 706 (top 8.5%)
- First Hour Rating
- 87 gal
- Storage Volume
- 72 gal
- Fuel / Type
- Electric / Hybrid/Electric Heat Pump
- DOE 2029 Rule Status
- Pass: +1.57 / +62.8%

Rheem XE80T10HS45U0 records 4.07 UEF efficiency, putting it #26 of 706 among 706 Hybrid/Electric Heat Pump peers.
10 CFR 430.32(d)(2) compliance: Rheem XE80T10HS45U0 exceeds 10 CFR 430.32(d)(2) Electric >55 to <=120 gal (2.50 UEF) by +1.57 UEF (+62.8%). At EIA August 2026 national rates (18.16 cents/kWh), 1,213 kWh/yr for Rheem XE80T10HS45U0 runs ~$220/yr vs. ~$974/yr for a 0.92 UEF electric tank.
State electric sensitivity for Rheem XE80T10HS45U0: 10-year operating spend spans $1,775 in Washington (Lowest Hydro Tier) (14.63 cents/kWh) to $5,723 in Hawaii (Highest EIA State) (47.18 cents/kWh).
Competing options beside Rheem XE80T10HS45U0 (4.07 UEF) are Friedrich PROH80 T2 FD400-30 (4.07 UEF, at parity) and Richmond 10CE80-HP5S30 (4.07 UEF, at parity).
Where Does Rheem XE80T10HS45U0 Rank Against Peer Hybrid/Electric Heat Pump Units?
Audited against 706 ENERGY STAR Hybrid/Electric Heat Pump listings, Rheem XE80T10HS45U0 holds #26 of 706 (top 8.5%); inspect footprint, circuit load, and efficiency deltas here.
| Specification Attribute | Certified Value | Cohort Benchmark / Delta | Provenance |
|---|---|---|---|
| Manufacturer / Brand | Rheem | 236 certified listings | ENERGY STAR PD 2408549 |
| Model Number | XE80T10HS45U0 | Draw pattern: High-Usage | XE80T10HS45U0 |
| Uniform Energy Factor (UEF) | 4.07 | +0.37 UEF vs. 3.70 UEF median | 10 CFR 430 Test Method |
| First Hour Rating (FHR) | 87 gal | +15 gal vs. 72 gal median | 10 CFR 430 Recovery Test |
| Rated Annual Electricity Use | 1,213 kWh/yr | +141 kWh/yr vs. 1,072 kWh/yr median | Est. $220/yr @ $0.1816/kWh (EIA US Avg) |
| Thermal Recovery Efficiency | 447% | +18.0 pts vs. 429.0% median | ENERGY STAR Dataset |
| Physical Envelope (H x Dia) | 74.2" H x 24.3" D | Needs >72 in. overhead clearance; clears 28 in. utility doorway (24.3" D) | Doorway & ceiling check |
| Electrical Circuit Requirements | 240 V / 21 A max | Requires 240V dedicated branch circuit; check panel capacity | NEC / Branch circuit check |
| Heat Pump Refrigerant & GWP | R-134a (GWP:1430) | Check regional AIM Act phase-down transition | EPA AIM Act Compliance |
| Certification Date | 2026-10-15 | Certified 2026-10-15 | Markets: United States |
How Much Electricity Does XE80T10HS45U0 Use in Different States?
Estimated at $220/yr nationally (1,213 kWh/yr), 10-year utility spending for Rheem XE80T10HS45U0 shifts sharply between low-rate hydro and coastal grids.
| Jurisdiction (EIA Aug 2026) | Residential Rate | Annual Cost | 10-Yr Operating Spend | 10-Yr Savings vs. 0.92 UEF |
|---|---|---|---|---|
| United States Average | 18.16 ¢/kWh ($0.1816) | $220/yr | $2,203 | $7,542 |
| Hawaii (Highest EIA State) | 47.18 ¢/kWh ($0.4718) | $572/yr | $5,723 | $19,594 |
| California | 29.75 ¢/kWh ($0.2975) | $361/yr | $3,609 | $12,355 |
| Texas | 15.91 ¢/kWh ($0.1591) | $193/yr | $1,930 | $6,607 |
| Washington (Lowest Hydro Tier) | 14.63 ¢/kWh ($0.1463) | $177/yr | $1,775 | $6,076 |
Does CPSC Flag Any Safety Notices on Rheem Units?
Checking 2026-11-23 SaferProducts data shows 4 notices mentioning Rheem; always cross-reference affected serial prefixes before ordering components. See Serial Number Lookup.
- Recall #16177 (2016-05-26): Rheem Recalls to Repair Water Heaters Due to Fire and Burn Hazards; Sold Exclusively at Home Depot (CPSC Notice)
- Recall #07108 (2007-02-21): Tankless Water Heaters Recalled for Repair Due to Carbon Monoxide Poisoning Hazard (CPSC Notice)
- Recall #05274 (2005-09-16): CPSC, Robertshaw Controls Co. Announce Recall of Gas Control Valves on Water Heaters (CPSC Notice)
- Recall #80042 (1980-12-04): LP Gas Water Heaters Repaired by White-Rodgers (CPSC Notice)
Which Competing Hybrid/Electric Heat Pump Models Compare Closest to XE80T10HS45U0?
Compare five nearby ENERGY STAR Hybrid/Electric Heat Pump options matched closely to Rheem XE80T10HS45U0's gallon capacity and 4.07 UEF efficiency.
| Brand & Model | Type | Vol | FHR | UEF (Δ) | kWh/yr |
|---|---|---|---|---|---|
| Friedrich PROH80 T2 FD400-30 | Hybrid/Electric Heat Pump | 72 gal | 87 gal | 4.07 (at parity) | 1,213 |
| Richmond 10CE80-HP5S30 | Hybrid/Electric Heat Pump | 72 gal | 87 gal | 4.07 (at parity) | 1,213 |
| Ruud CPROPH80 T2 CD375-30 | Hybrid/Electric Heat Pump | 72 gal | 87 gal | 4.07 (at parity) | 1,213 |
| LG APHWC802D | Hybrid/Electric Heat Pump | 72 gal | 91 gal | 4.1 (+0.03) | 1,210 |
| Friedrich PROH80 T2 FD400-SO | Hybrid/Electric Heat Pump | 72 gal | 87 gal | 4.07 (at parity) | 1,213 |
Which Home Setups Are NOT a Fit for Rheem XE80T10HS45U0?
Comparing Rheem XE80T10HS45U0 against Friedrich PROH80 T2 FD400-30 requires checking closet airflow, IFGC gas or 240V electrical sizing, and May 6, 2029 compliance.
Key Limitations & Exclusions
- Rheem XE80T10HS45U0 needs >=450 cu ft room air volume or ducting so compressor cooling does not stall recovery.
- Compressor runs near 49 dBA; avoid mounting Rheem XE80T10HS45U0 directly beside quiet bedrooms.
- Requires condensate drain routing and 240V electrical capacity; verify state DOE HEAR status.
Which Option Fits Your Situation?
Common Homeowner Questions for Rheem XE80T10HS45U0
Direct answers to common technical, regulatory, and sizing questions sourced from primary U.S. government and OEM documentation.
How does Rheem XE80T10HS45U0 score under 10 CFR 430.32 May 2029 water heater minimums?
Federal 10 CFR 430.32 rules set the May 6, 2029 manufacturing baseline; Rheem XE80T10HS45U0 logs 4.07 UEF (Pass: +1.57 / +62.8%) within the 706-unit Hybrid/Electric Heat Pump group.
What physical clearance dimensions apply when installing Rheem XE80T10HS45U0?
With a 74.2 in. height and 24.3 in. diameter, Rheem XE80T10HS45U0 fits spaces matching: needs >72 in. overhead clearance; clears 28 in. utility doorway (24.3" d), plus 6–12 in. above for plumbing shutoffs.
What 240V circuit or IFGC fuel line capacity fits Rheem XE80T10HS45U0?
Powered via 240V at 21A max, Rheem XE80T10HS45U0 requires: Requires 240V dedicated branch circuit; check panel capacity. Confirm double-pole breaker sizing and condensate pump outlet proximity.
How do state electricity prices change annual costs for Rheem XE80T10HS45U0?
Annual electric spend for Rheem XE80T10HS45U0 (1,213 kWh/yr) averages $220/yr nationwide (ranging from $177/yr in Washington hydro tiers up to $572/yr in Hawaii), calculated directly from August 2026 EIA Table 5.6.A tariffs.
What homeowner setups should avoid choosing Rheem XE80T10HS45U0?
Homes lacking a condensate drain or 240V branch circuit—or unconditioned sub-zero spaces—should verify hybrid backup mode limits on Rheem XE80T10HS45U0.
Is Rheem XE80T10HS45U0 sized adequately for a 2-to-4-person household?
ENERGY STAR certifies Rheem XE80T10HS45U0 at 87 gal First Hour Rating (+15 gal vs. 72 gal median); match that hourly reserve against simultaneous 2.0 GPM showerheads.
Does Rheem have active CPSC SaferProducts notices affecting XE80T10HS45U0?
CPSC SaferProducts records show 4 brand-level recall notices mentioning Rheem as of 2026-11-23, including #16177 (2016-05-26). Enter the rating-plate serial into TapAndPipe's Serial Lookup tool to verify production week.
Which competing water heater matches Rheem XE80T10HS45U0 (4.07 UEF) most closely?
State-run DOE HEAR programs (<=150% AMI, up to $1,750 for HPWH) and electric utilities lead 2026 incentives for Rheem XE80T10HS45U0. Closest peer in Hybrid/Electric Heat Pump is Friedrich PROH80 T2 FD400-30 (4.07 UEF).
Sources
- ENERGY STAR Certified Water Heaters Dataset (Socrata pbpq-swnu) — U.S. EPA & DOE ENERGY STAR, 2026 Live Certified Registry (retrieved 2026-11-23)
- 10 CFR 430.32 — Energy and Water Conservation Standards (Water Heaters & Plumbing Fixtures) — U.S. Department of Energy / eCFR, 2026 eCFR (incl. May 6, 2029 Rule) (retrieved 2026-11-23)
- CPSC SaferProducts.gov Product Recalls REST API — U.S. Consumer Product Safety Commission, 2026 Live Recalls Feed (retrieved 2026-11-23)
- EIA Electric Power Monthly Table 5.6.A — Average Residential Electricity Price by State — U.S. Energy Information Administration (EIA), August 2026 Monthly Release (retrieved 2026-11-23)