Ruud CPROPH50 T2 CD375-30 Water Heater Specifications (3.88 UEF)
Certified at 3.88 UEF across its 45-gallon nominal tank, 67 gal First Hour Rating, Ruud CPROPH50 T2 CD375-30 (Hybrid/Electric Heat Pump, Electric) places #165 of 706 out of 706 ENERGY STAR models (PD 4518086). Its May 6, 2029 10 CFR 430.32 status reads Pass: +1.58 / +68.7%. Rated annual electricity draw of 846 kWh/yr equates to roughly $154/yr ($1,536 over 10 years) at 18.16 cents/kWh. Closest certified alternative is Friedrich PROH50 T2 FD400-30 (3.88 UEF).
- Uniform Energy Factor
- 3.88 UEF
- Cohort UEF Rank
- #165 of 706 (top 30.6%)
- First Hour Rating
- 67 gal
- Storage Volume
- 45 gal
- Fuel / Type
- Electric / Hybrid/Electric Heat Pump
- DOE 2029 Rule Status
- Pass: +1.58 / +68.7%

Tested at 3.88 UEF, Ruud CPROPH50 T2 CD375-30 places #165 of 706 across 706 certified Hybrid/Electric Heat Pump configurations (+0.18 UEF vs. 3.70 UEF median).
Ruud CPROPH50 T2 CD375-30 clears 10 CFR 430.32(d)(2) Electric >35 to <=55 gal (2.30 UEF) by +1.58 UEF (+68.7% headroom). At EIA August 2026 national rates (18.16 cents/kWh), 846 kWh/yr for Ruud CPROPH50 T2 CD375-30 runs ~$154/yr vs. ~$648/yr for a 0.92 UEF electric tank.
State electric sensitivity for Ruud CPROPH50 T2 CD375-30: 10-year operating spend spans $1,238 in Washington (Lowest Hydro Tier) (14.63 cents/kWh) to $3,991 in Hawaii (Highest EIA State) (47.18 cents/kWh).
Closest alternatives to Ruud CPROPH50 T2 CD375-30 include Friedrich PROH50 T2 FD400-30 (3.88 UEF, at parity) alongside Rheem CPROPH50 T2 RH375-SO (3.88 UEF, at parity).
How Do Ruud CPROPH50 T2 CD375-30 Specs Compare to Hybrid/Electric Heat Pump Medians?
Ruud CPROPH50 T2 CD375-30 places #165 of 706 (top 30.6%) across 706 certified Hybrid/Electric Heat Pump configurations, with physical dimensions, draw profile, and thermal metrics benchmarked below.
| Specification Attribute | Certified Value | Cohort Benchmark / Delta | Provenance |
|---|---|---|---|
| Manufacturer / Brand | Ruud | 95 certified listings | ENERGY STAR PD 4518086 |
| Model Number | CPROPH50 T2 CD375-30 | Draw pattern: Medium-Usage | CPROPH50 T2 CD375-30 |
| Uniform Energy Factor (UEF) | 3.88 | +0.18 UEF vs. 3.70 UEF median | 10 CFR 430 Test Method |
| First Hour Rating (FHR) | 67 gal | -5 gal vs. 72 gal median | 10 CFR 430 Recovery Test |
| Rated Annual Electricity Use | 846 kWh/yr | -226 kWh/yr vs. 1,072 kWh/yr median | Est. $154/yr @ $0.1816/kWh (EIA US Avg) |
| Thermal Recovery Efficiency | 430% | +1.0 pts vs. 429.0% median | ENERGY STAR Dataset |
| Physical Envelope (H x Dia) | 61.8" H x 22.3" D | Fits standard 72 in. basement/garage clearance; clears 28 in. utility doorway (22.3" D) | Doorway & ceiling check |
| Electrical Circuit Requirements | 240 V / 21 A max | Requires 240V dedicated branch circuit; check panel capacity | NEC / Branch circuit check |
| Heat Pump Refrigerant & GWP | R-134a (GWP:1430) | Check regional AIM Act phase-down transition | EPA AIM Act Compliance |
| Certification Date | 2026-10-15 | Certified 2026-10-15 | Markets: Canada |
What Does CPROPH50 T2 CD375-30 Cost to Operate Across State Electricity Rates?
At 846 kWh/yr, Ruud CPROPH50 T2 CD375-30 runs roughly $154/yr on the EIA national average tier under August 2026 Table 5.6.A rates.
| Jurisdiction (EIA Aug 2026) | Residential Rate | Annual Cost | 10-Yr Operating Spend | 10-Yr Savings vs. 0.92 UEF |
|---|---|---|---|---|
| United States Average | 18.16 ¢/kWh ($0.1816) | $154/yr | $1,536 | $4,943 |
| Hawaii (Highest EIA State) | 47.18 ¢/kWh ($0.4718) | $399/yr | $3,991 | $12,842 |
| California | 29.75 ¢/kWh ($0.2975) | $252/yr | $2,517 | $8,098 |
| Texas | 15.91 ¢/kWh ($0.1591) | $135/yr | $1,346 | $4,331 |
| Washington (Lowest Hydro Tier) | 14.63 ¢/kWh ($0.1463) | $124/yr | $1,238 | $3,982 |
Are There Active CPSC Safety Recalls for Ruud Water Heaters?
Our 2026-11-23 CPSC SaferProducts query surfaced 2 brand-level recall notices associated with Ruud; match your serial plate before repair. See Serial Number Lookup.
- Recall #07108 (2007-02-21): Tankless Water Heaters Recalled for Repair Due to Carbon Monoxide Poisoning Hazard (CPSC Notice)
- Recall #05274 (2005-09-16): CPSC, Robertshaw Controls Co. Announce Recall of Gas Control Valves on Water Heaters (CPSC Notice)
Which Certified Water Heaters Match CPROPH50 T2 CD375-30 Most Closely?
These 5 competing Hybrid/Electric Heat Pump units sit nearest to Ruud CPROPH50 T2 CD375-30 by storage capacity and 3.88 UEF rating.
| Brand & Model | Type | Vol | FHR | UEF (Δ) | kWh/yr |
|---|---|---|---|---|---|
| Friedrich PROH50 T2 FD400-30 | Hybrid/Electric Heat Pump | 45 gal | 67 gal | 3.88 (at parity) | 846 |
| Rheem CPROPH50 T2 RH375-SO | Hybrid/Electric Heat Pump | 45 gal | 67 gal | 3.88 (at parity) | 846 |
| Richmond 10CE50-HP5S30 | Hybrid/Electric Heat Pump | 45 gal | 67 gal | 3.88 (at parity) | 846 |
| Bradford White RE2HP50**-1NCTT | Hybrid/Electric Heat Pump | 45 gal | 65 gal | 3.89 (+0.01) | 835 |
| Friedrich PROH50 T2 FD400-SO | Hybrid/Electric Heat Pump | 45 gal | 67 gal | 3.88 (at parity) | 846 |
What Installation Caveats Apply Before Buying Ruud CPROPH50 T2 CD375-30?
Even high-UEF units like Ruud CPROPH50 T2 CD375-30 (3.88 UEF) carry physical space, condensate, and fuel-line prerequisites noted below.
Key Limitations & Exclusions
- Ruud CPROPH50 T2 CD375-30 needs >=450 cu ft room air volume or ducting so compressor cooling does not stall recovery.
- Compressor runs near 49 dBA; avoid mounting Ruud CPROPH50 T2 CD375-30 directly beside quiet bedrooms.
- Requires condensate drain routing and 240V electrical capacity; verify state DOE HEAR status.
Which Option Fits Your Situation?
What Are the Key Questions About Ruud CPROPH50 T2 CD375-30?
Direct answers to common technical, regulatory, and sizing questions sourced from primary U.S. government and OEM documentation.
Is Ruud CPROPH50 T2 CD375-30 eligible for continued manufacture past May 6, 2029?
At 3.88 UEF, Ruud CPROPH50 T2 CD375-30 achieves Pass: +1.58 / +68.7% for the 2029 DOE standard and stands #165 of 706 (top 30.6%) against Friedrich PROH50 T2 FD400-30 and Rheem CPROPH50 T2 RH375-SO.
How tall and wide is Ruud CPROPH50 T2 CD375-30, and what service clearance is needed?
Physical dimensions for Ruud CPROPH50 T2 CD375-30 are 61.8 in. height and 22.3 in. diameter (fits standard 72 in. basement/garage clearance; clears 28 in. utility doorway (22.3" d)); verify stair turns and drain pan width before delivery.
Will Ruud CPROPH50 T2 CD375-30 require upgrading household electrical panels or gas piping?
Ruud CPROPH50 T2 CD375-30 draws 240V at 21A max (Requires 240V dedicated branch circuit; check panel capacity); check whether existing 10/2 AWG 30A copper wiring aligns with nameplate amps.
Is Ruud CPROPH50 T2 CD375-30 economical to operate at 18.16 cents/kWh US electric rates?
Expect roughly $154/yr ($1,540 over 10 years) to power Ruud CPROPH50 T2 CD375-30 at 846 kWh/yr under the 18.16 cents/kWh US average (ranging from $124/yr in Washington hydro tiers up to $399/yr in Hawaii).
Which installation bottlenecks limit Ruud CPROPH50 T2 CD375-30?
If ambient room air stays below 40 °F year-round or closet volume falls under 450 cu ft, Ruud CPROPH50 T2 CD375-30 drops into resistance mode more often.
How does Ruud CPROPH50 T2 CD375-30 handle simultaneous showers and laundry?
Delivering 67 gal in the first hour (-5 gal vs. 72 gal median), Ruud CPROPH50 T2 CD375-30 combines 45 gal tank storage with rapid burner/element recovery.
How long is the warranty on Ruud CPROPH50 T2 CD375-30 and how do you decode its serial?
CPSC SaferProducts records show 2 brand-level recall notices mentioning Ruud as of 2026-11-23, including #07108 (2007-02-21). Enter the rating-plate serial into TapAndPipe's Serial Lookup tool to verify production week.
How do 2026 post-OBBBA rebates affect buying Ruud CPROPH50 T2 CD375-30?
Check state energy office HEAR portals and utility rebates in 2026 since federal 25C ended Dec 31, 2025. Closest peer in Hybrid/Electric Heat Pump is Friedrich PROH50 T2 FD400-30 (3.88 UEF).
Sources
- ENERGY STAR Certified Water Heaters Dataset (Socrata pbpq-swnu) — U.S. EPA & DOE ENERGY STAR, 2026 Live Certified Registry (retrieved 2026-11-23)
- 10 CFR 430.32 — Energy and Water Conservation Standards (Water Heaters & Plumbing Fixtures) — U.S. Department of Energy / eCFR, 2026 eCFR (incl. May 6, 2029 Rule) (retrieved 2026-11-23)
- CPSC SaferProducts.gov Product Recalls REST API — U.S. Consumer Product Safety Commission, 2026 Live Recalls Feed (retrieved 2026-11-23)
- EIA Electric Power Monthly Table 5.6.A — Average Residential Electricity Price by State — U.S. Energy Information Administration (EIA), August 2026 Monthly Release (retrieved 2026-11-23)