Skip to main content
ENERGY STAR water heater model · PD 4572773

Richmond 10CE50-HP5U30 Water Heater Specifications (3.88 UEF)

With PD 4572773 certification, Richmond 10CE50-HP5U30 (Hybrid/Electric Heat Pump, Electric) achieves a certified 3.88 UEF rating across its 45-gallon nominal tank, 67 gal First Hour Rating, standing #165 of 706 across 706 peers with Pass: +1.58 / +68.7% for May 6, 2029. Rated annual electricity draw of 846 kWh/yr equates to roughly $154/yr ($1,536 over 10 years) at 18.16 cents/kWh. Closest certified alternative is Friedrich PROH50 T2 FD400-30 (3.88 UEF).

Uniform Energy Factor
3.88 UEF
Cohort UEF Rank
#165 of 706 (top 30.6%)
First Hour Rating
67 gal
Storage Volume
45 gal
Fuel / Type
Electric / Hybrid/Electric Heat Pump
DOE 2029 Rule Status
Pass: +1.58 / +68.7%
Hybrid heat pump water heater upper shroud with brass relief valve and insulated copper risers
Hybrid heat pump water heater upper shroud with brass relief valve and insulated copper risers
Hybrid/Electric Heat Pump UEF Efficiency Distribution (706 Certified Units)Distribution of certified UEF ratings across 706 units in Hybrid/Electric Heat Pump, marking Richmond 10CE50-HP5U30 at 3.88 UEF.21130201631342031241542.52 UEF4.50 UEFMedian 3.702029 min 2.30Richmond 10CE50-HP5U30: 3.88
Hybrid/Electric Heat Pump UEF Efficiency Distribution (706 Certified Units). Highlighted pin shows Richmond 10CE50-HP5U30 relative to the cohort median.
Efficiency comparison & rule summary

ENERGY STAR certification places Richmond 10CE50-HP5U30 at 3.88 UEF (#165 of 706; +0.18 UEF vs. 3.70 UEF median) in Hybrid/Electric Heat Pump.

May 6, 2029 readiness: Richmond 10CE50-HP5U30 stands +1.58 UEF (+68.7%) relative to 10 CFR 430.32(d)(2) Electric >35 to <=55 gal (2.30 UEF). At EIA August 2026 national rates (18.16 cents/kWh), 846 kWh/yr for Richmond 10CE50-HP5U30 runs ~$154/yr vs. ~$648/yr for a 0.92 UEF electric tank.

State electric sensitivity for Richmond 10CE50-HP5U30: 10-year operating spend spans $1,238 in Washington (Lowest Hydro Tier) (14.63 cents/kWh) to $3,991 in Hawaii (Highest EIA State) (47.18 cents/kWh).

In the Hybrid/Electric Heat Pump tier, Friedrich PROH50 T2 FD400-30 (3.88 UEF, at parity) and Rheem CPROPH50 T2 RH375-SO (3.88 UEF, at parity) bracket Richmond 10CE50-HP5U30.

Which Specs Set Richmond 10CE50-HP5U30 Apart From Cohort Averages?

Ranked #165 of 706 (top 30.6%) inside the 706-model Hybrid/Electric Heat Pump cohort, Richmond 10CE50-HP5U30 is evaluated row by row below against category medians.

Certified model attributes compared against 706 ENERGY STAR Hybrid/Electric Heat Pump peers
Specification AttributeCertified ValueCohort Benchmark / DeltaProvenance
Manufacturer / BrandRichmond80 certified listingsENERGY STAR PD 4572773
Model Number10CE50-HP5U30Draw pattern: Medium-Usage10CE50-HP5U30
Uniform Energy Factor (UEF)3.88+0.18 UEF vs. 3.70 UEF median10 CFR 430 Test Method
First Hour Rating (FHR)67 gal-5 gal vs. 72 gal median10 CFR 430 Recovery Test
Rated Annual Electricity Use846 kWh/yr-226 kWh/yr vs. 1,072 kWh/yr medianEst. $154/yr @ $0.1816/kWh (EIA US Avg)
Thermal Recovery Efficiency430%+1.0 pts vs. 429.0% medianENERGY STAR Dataset
Physical Envelope (H x Dia)61.8" H x 22.3" DFits standard 72 in. basement/garage clearance; clears 28 in. utility doorway (22.3" D)Doorway & ceiling check
Electrical Circuit Requirements240 V / 21 A maxRequires 240V dedicated branch circuit; check panel capacityNEC / Branch circuit check
Heat Pump Refrigerant & GWPR-134a (GWP:1430)Check regional AIM Act phase-down transitionEPA AIM Act Compliance
Certification Date2026-10-22Certified 2026-10-22Markets: Canada

How Do Regional kWh Prices Impact 10CE50-HP5U30 Over 10 Years?

Using EIA Table 5.6.A benchmarks, Richmond 10CE50-HP5U30's 846 kWh/yr draw translates to roughly $154/yr on typical US residential bills.

Estimated Annual Electricity Cost by State Rate (846 kWh/yr)Projected annual electricity spend across five benchmark EIA August 2026 residential electric tiers.United States Average$154.00/yrHawaii$399.00/yrCalifornia$252.00/yrTexas$135.00/yrWashington$124.00/yr
Projected annual electricity spend across five benchmark EIA August 2026 residential electric tiers.
Estimated electricity cost and 10-year spend across benchmark states
Jurisdiction (EIA Aug 2026)Residential RateAnnual Cost10-Yr Operating Spend10-Yr Savings vs. 0.92 UEF
United States Average 18.16 ¢/kWh ($0.1816) $154/yr $1,536 $4,943
Hawaii (Highest EIA State) 47.18 ¢/kWh ($0.4718) $399/yr $3,991 $12,842
California 29.75 ¢/kWh ($0.2975) $252/yr $2,517 $8,098
Texas 15.91 ¢/kWh ($0.1591) $135/yr $1,346 $4,331
Washington (Lowest Hydro Tier) 14.63 ¢/kWh ($0.1463) $124/yr $1,238 $3,982
Estimated electricity spend (846 kWh/yr)

Condensing Gas Tankless vs. Storage Tank Flow Path & Gas Supply Engineering schematic contrasting 199,000 BTU/h condensing tankless piping (3/4 in. gas supply, Category IV PVC vent, condensate drain) against a 40,000 BTU/h atmospheric tank. Condensing Gas Tankless (0.91–0.96 UEF) Secondary HX Cat IV PVC Vent Cold In Hot Out 3/4"–1" Gas 199K BTU/h Condensate Atmospheric Storage Tank (0.58–0.65 UEF) Type B Flue Anode Rod 40K BTU/h 1/2" Gas Up to 100 ft T&P 150 psi 50–85 gal FHR Reserve | 8–12 yr life
Technical comparison: condensing gas tankless units require 3/4 in.–1 in. IFGC Table 402.4 gas supply and Category IV condensate drainage, while atmospheric tanks run on 1/2 in. lines.

What Should Richmond Owners Check in CPSC Recall Logs?

The 2026-11-23 CPSC recall sweep recorded zero brand matches for Richmond; run a quick serial-number check to verify age before replacing wear parts. See Serial Number Lookup.

How Do Five Nearby Hybrid/Electric Heat Pump Models Stack Up?

Five alternative Hybrid/Electric Heat Pump units with nearly identical gallon storage and UEF scores are listed below alongside exact efficiency spreads.

5 closest certified peers matched by equipment class, storage volume, and efficiency rating
Brand & ModelTypeVolFHRUEF (Δ)kWh/yr
Friedrich PROH50 T2 FD400-30 Hybrid/Electric Heat Pump 45 gal 67 gal 3.88 (at parity) 846
Rheem CPROPH50 T2 RH375-SO Hybrid/Electric Heat Pump 45 gal 67 gal 3.88 (at parity) 846
Ruud CPROPH50 T2 CD375-30 Hybrid/Electric Heat Pump 45 gal 67 gal 3.88 (at parity) 846
Bradford White RE2HP50**-1NCTT Hybrid/Electric Heat Pump 45 gal 65 gal 3.89 (+0.01) 835
Friedrich PROH50 T2 FD400-SO Hybrid/Electric Heat Pump 45 gal 67 gal 3.88 (at parity) 846

Who Is Richmond 10CE50-HP5U30 Best For — and When Should You Pick Friedrich PROH50 T2 FD400-30?

Evaluate whether Richmond 10CE50-HP5U30's Hybrid/Electric Heat Pump architecture matches your existing mechanical room and local utility tariffs before purchasing.

Key Limitations & Exclusions

  • Richmond 10CE50-HP5U30 needs >=450 cu ft room air volume or ducting so compressor cooling does not stall recovery.
  • Compressor runs near 49 dBA; avoid mounting Richmond 10CE50-HP5U30 directly beside quiet bedrooms.
  • Requires condensate drain routing and 240V electrical capacity; verify state DOE HEAR status.

Which Option Fits Your Situation?

High Electric Rate States Choosing Richmond 10CE50-HP5U30 Strong Fit — 3.88 UEF trims electric use ~75% vs 0.92 UEF tanks.
Open Basement or Garage (>=450 cu ft) Strong Fit — Ample ambient air sustains heat-pump-only efficiency.
Small Interior Closet (<300 cu ft) Caution — Add duct kit or compare Friedrich PROH50 T2 FD400-30 footprint.

Frequently Asked Technical Questions: Richmond 10CE50-HP5U30

Direct answers to common technical, regulatory, and sizing questions sourced from primary U.S. government and OEM documentation.

How does Richmond 10CE50-HP5U30 (3.88 UEF) compare to 2029 federal DOE floors?

Evaluated against May 6, 2029 10 CFR 430.32 thresholds, Richmond 10CE50-HP5U30 records 3.88 UEF (Pass: +1.58 / +68.7%), placing #165 of 706 (top 30.6%) out of 706 certified Hybrid/Electric Heat Pump configurations.

Does Richmond 10CE50-HP5U30 fit inside a tight hallway closet or low-headroom utility room?

Richmond 10CE50-HP5U30 requires room for its 61.8 in. vertical shell and 22.3 in. diameter (fits standard 72 in. basement/garage clearance; clears 28 in. utility doorway (22.3" d)), plus service access for annual sediment draining.

What power supply or fuel line specs govern Richmond 10CE50-HP5U30?

For Richmond 10CE50-HP5U30, plan a 240V circuit at 21A max (Requires 240V dedicated branch circuit; check panel capacity) and keep a dedicated shutoff disconnect within sight of the unit.

What annual utility bill should homeowners budget for Richmond 10CE50-HP5U30?

Using 846 kWh/yr, Richmond 10CE50-HP5U30 generates an estimated $154/yr electric bill at 18.16 cents/kWh (ranging from $124/yr in Washington hydro tiers up to $399/yr in Hawaii)—use the custom rate slider above for your utility tariff.

What are the main drawbacks of Richmond 10CE50-HP5U30 (3.88 UEF)?

Richmond 10CE50-HP5U30 requires >=450 cu ft air space, 240V electrical supply, and drain access; tight interior alcoves favor ducted adapters or Friedrich PROH50 T2 FD400-30.

What hot-water delivery rating governs Richmond 10CE50-HP5U30?

Rated for 67 gal FHR (-5 gal vs. 72 gal median), Richmond 10CE50-HP5U30 prevents mid-morning cold drops when matched to 55–70+ gal multi-bath household loads.

Where do homeowners screen Richmond 10CE50-HP5U30 for recalls and tank age?

Verified clean against 2026-11-23 CPSC recall feeds for Richmond; use our browser-only serial decoder to inspect Richmond 10CE50-HP5U30's age and warranty window.

What alternative models sit closest to Richmond 10CE50-HP5U30 in the Hybrid/Electric Heat Pump class?

Closest peer in Hybrid/Electric Heat Pump is Friedrich PROH50 T2 FD400-30 (3.88 UEF). For 2026 incentives, look to state DOE HEAR grants ($1,750 max on qualifying HPWHs) and local municipal utility credits.

Sources

  1. ENERGY STAR Certified Water Heaters Dataset (Socrata pbpq-swnu) — U.S. EPA & DOE ENERGY STAR, 2026 Live Certified Registry (retrieved 2026-11-23)
  2. 10 CFR 430.32 — Energy and Water Conservation Standards (Water Heaters & Plumbing Fixtures) — U.S. Department of Energy / eCFR, 2026 eCFR (incl. May 6, 2029 Rule) (retrieved 2026-11-23)
  3. CPSC SaferProducts.gov Product Recalls REST API — U.S. Consumer Product Safety Commission, 2026 Live Recalls Feed (retrieved 2026-11-23)
  4. EIA Electric Power Monthly Table 5.6.A — Average Residential Electricity Price by State — U.S. Energy Information Administration (EIA), August 2026 Monthly Release (retrieved 2026-11-23)

Related U.S. Metro Plumbing Benchmarks